Search NASA⌕ Search

SEARCH · Search NASA

Results for “wavefront”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

TESTING THE APODIZED PUPIL LYOT CORONAGRAPH ON THE LABORATORY FOR ADAPTIVE OPTICS EXTREME ADAPTIVE OPTICS TESTBED

We present testbed results of the Apodized Pupil Lyot Coronagraph (APLC) at the Laboratory for Adaptive Optics (LAO). These results are part of the validation and tests of the coronagraph and of the Extreme Adaptive Optics (ExAO) for the Gemini Planet Imager (GPI). The apodizer component is manufactured with a halftone technique using black chrome microdots on glass. Testing this APLC (like any other coronagraph) requires extremely good wavefront correction, which is obtained to the 1 nm rms level using the microelectricalmechanical systems (MEMS) technology, on the ExAO visible testbed of the LAO at the University of Santa Cruz. We used an APLC coronagraph without central obstruction, both with a reference super-polished flat mirror and with the MEMS to obtain one of the first images of a dark zone in a coronagraphic image with classical adaptive optics using a MEMS deformable mirror (without involving dark hole algorithms). This was done as a complementary test to the GPI coronagraph testbed at American Museum of Natural History, which studied the coronagraph itself without wavefront correction. Because we needed a full aperture, the coronagraph design is very different from the GPI design. We also tested a coronagraph with central obstruction similar to that of GPI. We investigated the performance of the APLC coronagraph and more particularly the effect of the apodizer profile accuracy on the contrast. Finally, we compared the resulting contrast to predictions made with a wavefront propagation model of the testbed to understand the effects of phase and amplitude errors on the final contrast.

79 ASTRONOMY AND ASTROPHYSICS↗

EVIDENCE FOR THE WAVE NATURE OF AN EXTREME ULTRAVIOLET WAVE OBSERVED BY THE ATMOSPHERIC IMAGING ASSEMBLY ON BOARD THE SOLAR DYNAMICS OBSERVATORY

Extreme-ultraviolet (EUV) waves have been found for about 15 years. However, significant controversy remains over their physical natures and origins. In this paper, we report an EUV wave that was accompanied by an X1.9 flare and a partial halo coronal mass ejection (CME). Using high temporal and spatial resolution observations taken by the Solar Dynamics Observatory and the Solar-TErrestrial RElations Observatory, we are able to investigate the detailed kinematics of the EUV wave. We find several arguments that support the fast-mode wave scenario. (1) The speed of the EUV wave (570 km s{sup -1}) is higher than the sound speed of the quiet-Sun corona. (2) Significant deceleration of the EUV wave (-130 m s{sup -2}) is found during its propagation. (3) The EUV wave resulted in the oscillations of a loop and a filament along its propagation path, and a reflected wave from the polar coronal hole is also detected. (4) Refraction or reflection effect is observed when the EUV wave was passing through two coronal bright points. (5) The dimming region behind the wavefront stopped to expand when the wavefront started to become diffuse. (6) The profiles of the wavefront exhibited a dispersive nature, and the magnetosonic Mach number of the EUV wave derived from the highest intensity jump is about 1.4. In addition, triangulation indicates that the EUV wave propagated within a height range of about 60-100 Mm above the photosphere. We propose that the EUV wave observed should be a nonlinear fast-mode magnetosonic wave that propagated freely in the corona after it was driven by the CME expanding flanks during the initial period.

79 ASTRONOMY AND ASTROPHYSICS↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Small Bragg-plane slope errors revealed in synthetic diamond crystals

Wavefront-preserving X-ray diamond crystal optics are essential for numerous applications in X-ray science. Perfect crystals with flat Bragg planes are a prerequisite for wavefront preservation in Bragg diffraction. However, this condition is difficult to realize in practice because of inevitable crystal imperfections. Here, X-ray rocking curve imaging is used to study the smallest achievable Bragg-plane slope errors in the best presently available synthetic diamond crystals and how they compare with those of perfect silicon crystals. It is shown that the smallest specific slope errors in the best diamond crystals are about 0.08 (3) µrad mm -2 . These errors are only 50% larger than the 0.05 (2) µrad mm -2 specific slope errors measured in perfect silicon crystals. High-temperature annealing at 1450°C of almost flawless diamond crystals reduces the slope errors very close to those of silicon. Further investigations are in progress to establish the wavefront-preservation properties of these crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

Super-resolution image display using diffractive decoders

High-resolution image projection over a large field of view (FOV) is hindered by the restricted space-bandwidth product (SBP) of wavefront modulators. We report a deep learning–enabled diffractive display based on a jointly trained pair of an electronic encoder and a diffractive decoder to synthesize/project super-resolved images using low-resolution wavefront modulators. The digital encoder rapidly preprocesses the high-resolution images so that their spatial information is encoded into low-resolution patterns, projected via a low SBP wavefront modulator. The diffractive decoder processes these low-resolution patterns using transmissive layers structured using deep learning to all-optically synthesize/project super-resolved images at its output FOV. This diffractive image display can achieve a super-resolution factor of ~4, increasing the SBP by ~16-fold. We experimentally validate its success using 3D-printed diffractive decoders that operate at the terahertz spectrum. This diffractive image decoder can be scaled to operate at visible wavelengths and used to design large SBP displays that are compact, low power, and computationally efficient.

36 MATERIALS SCIENCE↗

Optimization of microwave emission from laser filamentation with a machine learning algorithm

We demonstrate that is it possible to optimize the yield of microwave radiation from plasmas generated by laser filamentation in atmosphere through manipulation of the laser wavefront. A genetic algorithm controls a deformable mirror that reconfigures the wavefront using the microwave waveform amplitude as feedback. Optimization runs performed as a function of air pressure show that the genetic algorithm can double the microwave field strength relative to when the mirror surface is flat. Here, an increase in the volume and brightness of the plasma fluorescence accompanies the increase in microwave radiation, implying an improvement in the laser beam intensity profile through the filamentation region due to the optimized wavefront.

Englesbe, Alexander↗

Ionizing potential waves and high-voltage breakdown streamers.

The structure of ionizing potential waves driven by a strong electric field in a dense gas is discussed. Negative breakdown waves are found to propagate with a velocity proportional to the electric field normal to the wavefront. This causes a curved ionizing potential wavefront to focus down into a filamentary structure, and may provide the reason why breakdown in dense gases propagates in the form of a narrow leader streamer instead of a broad wavefront.

Albright, N. W.↗

Alignment and evaluation of the cryogenic corrected infrared astronomical satellite /IRAS/ telescope

Room temperature alignment and evaluation techniques for the Infrared Astronomical Satellite (IRAS) telescope, which has a primary mirror figured to correct for surface distortions and the 2 K operating temperature are discussed. Interferometric cryogenic testing of the 0.6 m, f/1.5 lightweighted beryllium primary mirror at its intended operating temperature reveals surface distortions that can be modeled with Zernike polynomials. With this model, it becomes possible to derive the 'inverse' of the cryowavefront error (ideal cryo mirror) and to figure the cryo correction into the primary mirror using Perkin-Elmer's Computer Controlled Polisher. It is recognized that during room temperature assembly of the system, misalignment of the secondary mirror can introduce additional unwanted aberrations that may cancel or distort the wavefront errors purposely introduced by the cryo figuring. To avoid this possible degradation and to ensure optimum telescope performance, the system Zernike polynomial coefficients and wavefront maps generated from the in-process alignment interferograms are monitored and compared to Zernike coefficients and wavefront maps for the cryo corrected primary mirror.

Harned, N.↗

Optical Studies of model binary miscibility gap system

In order to develop a better understanding of separation processes in binary miscibility gap metal alloys, model transparent fluid systems were studied. The system selected was diethylene glycol-ethyl salicylate which has convenient working temperatures (288 to 350 K), low toxicity, and is relatively easy to purify. The system is well characterized with respect to its phase diagram, density, surface and interfacial tensions, viscosity and other pertinent physical properties. Studies of migration of the dispersed phase in a thermal gradient were performed using conventional photomicroscopy. Velocities of the droplets of the dispersed phase were measured and compared to calculated rates which included both Stokes and thermal components. A holographic microscopy system was used to study growth, coalescence, and particle motions. Sequential holograms allowed determination of particle size distribution changes with respect to time and temperature. Holographic microscopy is capable of recording particle densities up to 10 to the 7th power particles/cu cm and is able to resolve particles of the order of 2 to 3 microns in diameter throughout the entire volume of the test cell. The reconstructed hologram produces a wavefront that is identical to the original wavefront as it existed when the hologram was made. The reconstructed wavefront is analyzed using a variety of conventional optical methods.

Lacy, L. L.↗

High-frequency wave normals in the solar wind

High-frequency (0.01-0.04 Hz) magnetic fluctuations in 506 ten-minute intervals of contemporaneous Explorer 35 and Apollo 12 measurements made in the solar wind near the morning side of the earth's bow shock show the presence of a large population of disturbances resembling Alfven waves. Each wavefront normal is systematically aligned (median deviation = 35 deg) with the associated ten-minute average of the magnetic field. Because of variability in the direction of this ten-minute average, from one interval to another, the coupled wavefront-normal distribution is nearly isotropic in solar ecliptic coordinates, in contrast with the results of other studies of waves at much lower frequency indicating outward propagation from the sun. Presumably the high frequency waves discussed here are stirred into isotropy (in solar ecliptic coordinates) by following the low frequency fluctuations. As these waves maintain their alignment of wavefront-normal with the field ten-minute average despite the great variation of the field ten-minute average, a strong physical alignment constraint is inferred.

Herbert, F.↗

Analytical caustic surfaces

This document discusses the determination of caustic surfaces in terms of rays, reflectors, and wavefronts. Analytical caustics are obtained as a family of lines, a set of points, and several types of equations for geometries encountered in optics and microwave applications. Standard methods of differential geometry are applied under different approaches: directly to reflector surfaces, and alternatively, to wavefronts, to obtain analytical caustics of two sheets or branches. Gauss/Seidel aberrations are introduced into the wavefront approach, forcing the retention of all three coefficients of both the first- and the second-fundamental forms of differential geometry. An existing method for obtaining caustic surfaces through exploitation of the singularities in flux density is examined, and several constant-intensity contour maps are developed using only the intrinsic Gaussian, mean, and normal curvatures of the reflector. Numerous references are provided for extending the material of the present document to the morphologies of caustics and their associated diffraction patterns.

Schmidt, R. F.↗

Imaging performance of annular apertures. VI - Limitations by optical surface deviations

The performance of optical systems is limited by imperfect optical surfaces that degrade the images below the level set by wave theoretical limits. The central irradiance functions are derived for slit and circular apertures with five distributions of wavefront errors and for a range of maximal wavefront deviations. For practical frequency of occurrence distributions of wavefront deviations, the point spread and the image energy integral functions are determined. Practical performances of optical systems are derived and performance limits discussed.

Tschunko, Hubert F. A.↗

Reconstruction of the Hubble Space Telescope mirror figure from out-of-focus stellar images

Both the amplitude and the phase of the incoming wave front viewed from the focal plane are reconstructed from the illumination recorded in defocused stellar images taken in flight by the HST. The reconstructed wavefront surface shows very little aberration. Compared to geometrical optics methods, the technique produces high spatial resolution wavefront maps with images taken closer to the telescope's focal plane. For the HST, the quality of the wavefront reconstruction is limited by the telescope jitter. The technique cannot be applied to ground-based telescopes at optical wavelength where the image is heavily blurred by the atmosphere. It is argued to be promising as a diagnostic tool for optical telescopes in space.

Roddier, C.↗

Hubble Extra Solar Planet Interferometer

This paper describes a proposed third-generation Hubble instrument for extra-solar planet detection, the Hubble Extra-Solar Planet Interferometer (HESPI). This instrument would be able to achieve starlight cancellation at the 10 exp 6 to 10 exp 8 level, given a stellar wavefront with phase errors comparable to the present Hubble telescope wavefront. At 10 exp 6 starlight cancellation, HESPI would be able to detect a Jupiter-like planet next to a star at a distance of about 10 parsec, for which there are about 400 candidate stars. This paper describes a novel approach for starlight suppression, using a combination of active control and single-mode spatial filters, to achieve starlight suppression far below the classical limit set by scattering due to microsurface imperfections. In preliminary lab experiments, suppression by a factor of 40 below the classical scatter limit due to optical wavefront errors has been demonstrated.

Shao, M.↗

Cryogenic Optical Systems and Instrumentation IX (AM 116) Newly Modified Cryogenic Optical Test Facility at the Marshall Space Flight Center

Marshall Space Flight Center (MSFC) has maintained and operated a world-class x-ray optics and detector testing facility known as the X-ray Calibration Facility (XRCF) since the mid 1970's. The ground test and calibration of the Chandra X-ray Observatory optics and detectors were successfully completed at the XRCF in 1997. The beginning of the Next Generation Space Telescope (NGST) development programs (NMSD, SBMD, AMSD, etc.) and the establishment of the Space Optics Manufacturing Technology Center at MSFC have led to an XRCF modification. In 1999 the facility was upgraded to perform cryogenic testing of lightweight visible optics (without compromising the existing x-ray testing capability). A thermal enclosure capable of 20 degrees Kelvin and vibration isolated instrumentation mount were added. A vacuum-compatible five-axis motion table was modified to operate under cryogenic conditions. Optics up to two meters in diameter with radii of curvature of up to twenty meters can be accommodated. Facility characterization tests and one NGST program mirror test have been completed to date. By July 2000, two other mirrors will be tested. Optical wavefront measurements were made at < 35 degrees Kelvin with several instruments located at the test mirror's radius of curvature. The current wavefront measuring instruments include a Shack-Hartman wavefront sensor, a point diffraction interferometer, a point spread function-measuring device, and a radius of curvature measuring instrument. A vibration insensitive phase shifting interferometer is planned for future optical testing. This paper will present a brief history of the facility, a discussion of its current x-ray optic testing capabilities, and a complete description of the new capabilities in the visible optical testing regime.

Eng, Ronnie↗

Adjustable Focus Optical Correction Lens (AFOCL)

This report describes a metrology plan that was developed for the characterization of PLZT-based devices, such as the Adjustable Focus Optical Correction Lens (AFOCL) in support of and as part of the deliverables for NASA contract NAS8-00118. The areas to be investigated include intensiometric effects (those that limit or alter the intensity of the light transmitted through the optic); interferometric effects (the phase change induced through the optic); and polarimetric effects (evaluating the differential lag between two polarization states propagating through the optic). These distinct phenomena are often coupled together in real applications consequently, there is a need to develop different standardized testing apparatus to: (1) isolate one effect from another; (2) gather information for understanding the physical effects; (3) anchor wavefront corrector modeling efforts; (4) develop the ability to decouple different effects; (5) demonstrate the suitability of PLZT technology to perform wavefront correction. The Center for Applied Optics (CAO) at the University of Alabama in Huntsville (UAH) is skilled in the characterization of transmission wavefront shaping devices using traditional interferometers available within the CAO Optical Metrology Laboratory and their Advanced Polarization Test Facility. Besides the imaging and interferometers available, the polarimetry facility has at its disposal, a Mueller Matrix Imaging Polarimeter (MMIP) which is well suited to the characterization of SLMs, polarizers, and thin film coatings within the visible and near-IR spectrums. In addition, the phase-shifting interferometry facilities at NASA-MSFC and the unique interferometers they processes are some of the most advanced available and may be of value especially for performing real-time optical performance evaluation of AFOCL test components.

Peters, Bruce R.↗

High Resolution Imaging from the Stratosphere: Atmospheric Seeing and Tether Dynamics

A balloon-borne telescope that is capable of imaging planets orbiting nearby stars requires that the flatness and tilt of the wavefront of the light entering that telescope meet certain stringent conditions. The atmosphere through which the light propagates distorts the wavefront due to turbulence in the atmosphere and due to the disturbances caused by the balloon itself The magnitude of these effects may be estimated, but no direct measurements have been made at the level of precision necessary for designing a telescope as demanding as we envision. Therefore, under this grant we carried out a study of techniques that could be used to make an in situ measurement of the distortion of the optical wavefront.

Ford, Holland↗