Search NASA⌕ Search

SEARCH · Search NASA

Results for “AUTOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

An iterative dynamic chemical stiffness removal method for reacting flow simulations

Abstract An iterative dynamic chemical stiffness removal method (IDCSR) based on quasi-steady-state approximation (QSSA) is proposed. The IDCSR method is built on a previously developed non-iterative method which has proved to work well for small timestep sizes. A novel iterative procedure is designed in IDCSR to enable explicit time integration of stiff chemistry at relatively large timestep sizes relevant to practical reacting flow simulations. The effectiveness of the iterative procedure is first demonstrated with a toy problem and homogeneous auto-ignition with fixed integration step sizes, showing that larger timestep sizes can be allowed for explicit time integration using IDCSR compared with the previous non-iterative method. IDCSR is then compared with existing explicit chemistry solvers for simulations of homogeneous auto-ignition and shows similar or lower computational cost but significantly higher accuracy across a wide range of timestep sizes. IDCSR is further combined with an automatic adaptive time-stepping scheme for simulations of 0-D homogeneous auto-ignition and a 2-D laminar lifted n -dodecane jet flame. For the 0-D auto-ignition simulations, IDCSR is shown to reduce both the error (by 43%–90%) and computational cost (by 6–15 times) compared with existing explicit solvers, while achieving speed-up factors of up to 400 compared with VODE for a wide range of timestep sizes and reaction mechanisms. For the 2-D jet flame simulations, speed-up factors of 15 and 31 for chemistry integration, and 5 and 9 for overall simulation, are achieved by IDCSR compared with CVODE with and without analytic Jacobian, respectively.

Xu, Chao (ORCID:0000000153074159)↗

From fault-detection to automated fault correction: A field study

A fault detection and diagnostics (FDD) tool, as addressed by this study, is a tool that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Although FDD tools can inform operators of building operational faults, currently an action is always required to correct the faults to generate energy savings. Fault auto-correction integrating with commercial FDD technology offerings can close the loop between the passive diagnostics and active control, increase the savings generated by FDD tools, and reduce the reliance on human intervention. This paper presents the field study of seven fault auto-correction algorithms implemented in commercial FDD platforms. Implementation includes software changes in the FDD tools and additional controls hardware or software changes in the BAS that were required to enable the execution of different types of auto-correction algorithms in real buildings. The routines successfully and automatically correct faults and improve the operation of large built-up Heating, Ventilation, and Air Conditioning (HVAC) systems, common in most commercial buildings. The auto-correction algorithms are tested across four buildings and three different building automation systems, following a rigorous procedure to make sure they work properly and do not negatively impact the system and building occupants. Finally, technology benefits, market drivers, and scalability changes are drawn from the implementation effort and test results, to drive future research and industry engagement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of NO on extinction and re-ignition of vortex-perturbed hydrogen flames

The catalytic effect of nitric oxide (NO) on the dynamics of extinction and re-ignition of a vortex-perturbed non-premixed hydrogen-air flame is studied in a counterflow burner. A diffusion flame is established with counterflowing streams of nitrogen-diluted hydrogen at ambient temperature and air heated to a range of temperatures that brackets the auto-ignition temperature. Localized extinction is induced by impulsively driving a fuel-side toroidal vortex into the steady flame, and the recovery of the extinguished region is monitored by planar laser-induced fluorescence (PLIF) of the hydroxyl radical (OH). The dynamics of flame recovery depend on the air temperature and fuel concentration, and four different recovery modes are identified. These modes involve combinations of edge-flame propagation and the expansion of an auto-ignition kernel that forms within the extinguished region. The addition of a small amount of NO significantly alters the re-ignition process by shifting the balance between chain-termination and chain-propagation reactions to enhance auto-ignition. The ignition enhancement by this catalytic effect causes a shift in the conditions that govern the recovery modes. In addition, the effects of NO concentration and vortex strength on the flame recovery are examined. Direct numerical simulations of the flame-vortex interaction with and without NO doping show how the small amount of OH produced by NO-catalyzed reactions has a significant impact on the development of an auto-ignition kernel. This joint experimental and numerical study provides detailed insight into the interaction between transient flows and ignition processes. (author)

08 HYDROGEN↗

A novel IMRT planning study by using the fixed-jaw method in the treatment of peripheral lung cancer with mediastinal lymph node metastasis

Intensity-modulated radiotherapy (IMRT) is an important technology in cancer radiotherapy. In the current planning system, such as in the Pinnacle{sup 3} system, jaw positions are automatically set to cover all target volumes, and many medical centers in developing countries are not equipped with linear accelerators with a jaw tracing function. As solitary lesions are often located in patients, the resulting radiation leakage and transmission increase the dose exposure in surrounding critical organs, although blocked by multileaf collimator (MLC) leaves. We therefore designed a method to manually fix jaw positions, which further reduces doses. We particularly focused on the patients of peripheral lung cancer combined with mediastinal lymph node metastasis, as our medical center mainly targets lung cancer. We designed 2 treatment plans for each patient with the same optimization parameters, i.e., the plan of automatically chosen jaw positions (jaw auto-chosen plan) and the plan of fixed-jaw positions (fixed-jaw plan). In the latter plan, jaws were manually fixed for tumors in lung and in mediastinal lymph node metastases, respectively. We found that both plans met the clinical requirements, and the D{sub 2}, D{sub 98}, conformation number (CN), and homogeneity index (HI) for planning target volume (PTV) had no significant differences between the 2 plans. Importantly, the machine units (MUs) for fixed-jaw plans were 50%~60% more than routine jaw auto-chosen plans, whereas the V{sub 5}, V{sub 10}, V{sub 20}, V{sub 30}, and the mean dose in the total lung and the ipsilateral lung were less than the routine jaw auto-chosen plans. Dose-volume values D{sub 1} for the spinal cord and D{sub 2}, V{sub 40}, V{sub 60} for the heart existed no significant differences for 2 plans. In the fixed-jaw method, the total lung TLV{sub 5}-â–³V{sub ab} and TLV{sub 10}-â–³V{sub ab} values had a moderate positive correlation with the lung radiation leakage and the transmission area reduction. We concluded that the fixed-jaw plan is superior to the routine jaw auto-chosen plan in reducing the radiation exposure of surrounding critical organs, which will benefit the IMRT application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low level exposure to inorganic mercury interferes with B cell receptor signaling in transitional type 1 B cells

Mercury (Hg) has been implicated as a factor contributing to autoimmune disease in animal models and humans. However the mechanism by which this occurs has remained elusive. Since the discovery of B cells it has been appreciated by immunologists that during the normal course of B cell development, some immature B cells must be generated that produce immunoglobulin reactive to self-antigens (auto-antibodies). However in the course of normal development, the vast majority of immature auto-reactive B cells are prevented from maturing by processes collectively known as tolerance. Autoimmune disease arises when these mechanisms of tolerance are disrupted. In the B cell compartment, it is firmly established that tolerance depends in part upon negative selection of self-reactive immature (transitional type 1) B cells. In these cells negative selection depends upon signals generated by the B Cell Receptor (BCR), in the sense that those T1 B cells who's BCRs most strongly bind to, and so generate the strongest signals to self-antigens are neutralized. In this report we have utilized multicolor phosphoflow cytometry to show that in immature T1 B cells Hg attenuates signal generation by the BCR through mechanisms that may involve Lyn, a key tyrosine kinase in the BCR signal transduction pathway. We suggest that exposure to low, environmentally relevant levels of Hg, disrupts tolerance by interfering with BCR signaling in immature B cells, potentially leading to the appearance of mature auto-reactive B cells which have the ability to contribute to auto-immune disease. - Highlights: • Hg{sup 2+} interferes with BCR-mediated activation of ERK in immature T1 B cells. • Hg{sup 2+} acts upstream of ERK. • BCR mediated activation of Syk and the CD79a ITAM are attenuated in immature T1 B cells by Hg{sup 2+}. • The mechanism whereby which Hg{sup 2+} affects Syk and CD7a activation involves the tyrosine phosphokinase Lyn.

60 APPLIED LIFE SCIENCES↗

Autonomous Molecular Structure Imaging with High-Resolution Atomic Force Microscopy for Molecular Mixture Discovery

Due to its single-molecule sensitivity, high-resolution atomic force microscopy (HR-AFM) has proved to be a valuable and uniquely advantageous tool to study complex molecular mixtures, which hold promise for developing clean energy and achieving environmental sustainability. However, significant challenges remain to achieve the full potential of the sophisticated and time-consuming experiments. Automation combined with machine learning (ML) and artificial intelligence (AI) is key to overcoming these challenges. Here we present Auto-HR-AFM, an AI tool to automatically collect HR-AFM images of petroleum-based mixtures. In this study, we trained an instance segmentation model to teach Auto-HR-AFM how to recognize features in HR-AFM images. Auto-HR-AFM then uses that information to optimize the imaging by adjusting the probe-molecule distance for each molecule in the run. Auto-HR-AFM is the initial tool that will lead to fully automated scanning probe microscopy (SPM) experiments, from start to finish. This automation will allow SPM to become a mainstream characterization technique for complex mixtures, an otherwise unattainable target.

36 MATERIALS SCIENCE↗

Phase coherence of parametric-decay modes during high-harmonic fast-wave heating in the National Spherical Torus Experiment

Third-order spectral analysis, in particular, the auto bicoherence, was applied to probe signals from high-harmonic fast-wave heating experiments in the National Spherical Torus Experiment. Strong evidence was found for parametric decay of the 30 MHz radio-frequency (RF) pump wave, with a low-frequency daughter wave at 2.7 MHz, the local majority-ion cyclotron frequency. The primary decay modes have auto bicoherence values around 0.85, very close to the theoretical value of one, which corresponds to total phase coherence with the pump wave. The threshold RF pump power for onset of parametric decay was found to be between 200 kW and 400 kW.

Carlsson, J. A. (ORCID:0000000346148150)↗

Measurements of E-mode polarization and temperature-E-MODE correlation in the cosmic microwave background from 100 square degrees of SPTPOL data

We present measurements of E-mode polarization and temperature-E-mode correlation in the cosmic microwave background using data from the first season of observations with SPTpol, the polarization-sensitive receiver currently installed on the South Pole Telescope (SPT). The observations used in this work cover 100 deg{sup 2} of sky with arcminute resolution at 150 GHz. We report the E-mode angular auto-power spectrum (EE) and the temperature-E-mode angular cross-power spectrum (TE) over the multipole range 500 < ℓ ≤ 5000. These power spectra improve on previous measurements in the high-ℓ (small-scale) regime. We fit the combination of the SPTpol power spectra, data from Planck, and previous SPT measurements with a six-parameter ΛCDM cosmological model. We find that the best-fit parameters are consistent with previous results. The improvement in high-ℓ sensitivity over previous measurements leads to a significant improvement in the limit on polarized point-source power: after masking sources brighter than 50 mJy in unpolarized flux at 150 GHz, we find a 95% confidence upper limit on unclustered point-source power in the EE spectrum of D{sub ℓ}=ℓ(ℓ+1)C{sub ℓ}/2π<0.40 μK{sup 2} at ℓ=3000, indicating that future EE measurements will not be limited by power from unclustered point sources in the multipole range ℓ<3600, and possibly much higher in ℓ.

79 ASTRONOMY AND ASTROPHYSICS↗

Lagrangian bias in the local bias model

It is often assumed that the halo-patch fluctuation field can be written as a Taylor series in the initial Lagrangian dark matter density fluctuation field. We show that if this Lagrangian bias is local, and the initial conditions are Gaussian, then the two-point cross-correlation between halos and mass should be linearly proportional to the mass-mass auto-correlation function. This statement is exact and valid on all scales; there are no higher order contributions, e.g., from terms proportional to products or convolutions of two-point functions, which one might have thought would appear upon truncating the Taylor series of the halo bias function. In addition, the auto-correlation function of locally biased tracers can be written as a Taylor series in the auto-correlation function of the mass; there are no terms involving, e.g., derivatives or convolutions. Moreover, although the leading order coefficient, the linear bias factor of the auto-correlation function is just the square of that for the cross-correlation, it is the same as that obtained from expanding the mean number of halos as a function of the local density only in the large-scale limit. In principle, these relations allow simple tests of whether or not halo bias is indeed local in Lagrangian space. We discuss why things are more complicated in practice. We also discuss our results in light of recent work on the renormalizability of halo bias, demonstrating that it is better to renormalize than not. We use the Lognormal model to illustrate many of our findings.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey Year 1 Results: Cosmological Constraints from Cluster Abundances, Weak Lensing, and Galaxy Correlations

We present the first joint analysis of cluster abundances and auto or cross-correlations of three cosmic tracer fields: galaxy density, weak gravitational lensing shear, and cluster density split by optical richness. From a joint analysis (4×2pt+N) of cluster abundances, three cluster cross-correlations, and the auto correlations of the galaxy density measured from the first year data of the Dark Energy Survey, we obtain Ωm=0.305-0.038+0.055 and σ8=0.783-0.054+0.064. This result is consistent with constraints from the DES-Y1 galaxy clustering and weak lensing two-point correlation functions for the flat νΛCDM model. Consequently, we combine cluster abundances and all two-point correlations from across all three cosmic tracer fields (6×2pt+N) and find improved constraints on cosmological parameters as well as on the cluster observable-mass scaling relation. This analysis is an important advance in both optical cluster cosmology and multiprobe analyses of upcoming wide imaging surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

A transported Livengood-Wu integral model for knock prediction in CFD simulation

This work describes the development of a transported Livengood-Wu (L-W) integral model for computational fluid dynamics (CFD) simulation to predict auto-ignition and engine knock tendency. The currently employed L-W integral model considers both single-stage and two-stage ignition processes, thus can be generally applied to different fuels such as paraffin, olefin, aromatics and alcohol. The model implementation is first validated in simulations of homogeneous charge compression ignition combustion for three different fuels, showing good accuracy in prediction of auto-ignition timing for fuels with either single-stage or two-stage ignition characteristics. Then, the L-W integral model is coupled with G-equation model to indicate end-gas auto-ignition and knock tendency in CFD simulations of a direct injection spark ignition engine. This modeling approach is about 10 times more efficient than the ones that based on detailed chemistry calculation and pressure oscillation analysis. Two fuels with same Research Octane Number (RON) but different octane sensitivity are studied, namely Co-Optima Alkylate and Co-Optima E30. Feed-forward neural network model in conjunction with multi-variable minimization technique is used to generate fuel surrogates with targets of matched RON, octane sensitivity and ethanol content. The CFD model is validated against experimental data in terms of pressure traces and heat release rate for both fuels under a wide range of operating conditions. The knock tendency indicated by the fuel energy contained in the auto-ignited region of the two fuels at different load conditions correlates well with the experimental results and the fuel octane sensitivity, implying the current knock modeling approach can capture the octane sensitivity effect and can be applied to further investigation on composition of octane sensitivity.

Yue, Zongyu↗

SU-E-J-129: Atlas Development for Cardiac Automatic Contouring Using Multi-Atlas Segmentation

Purpose: To develop a set of atlases for automatic contouring of cardiac structures to determine heart radiation dose and the associated toxicity. Methods: Six thoracic cancer patients with both contrast and non-contrast CT images were acquired for this study. Eight radiation oncologists manually and independently delineated cardiac contours on the non-contrast CT by referring to the fused contrast CT and following the RTOG 1106 atlas contouring guideline. Fifteen regions of interest (ROIs) were delineated, including heart, four chambers, four coronary arteries, pulmonary artery and vein, inferior and superior vena cava, and ascending and descending aorta. Individual expert contours were fused using the simultaneous truth and performance level estimation (STAPLE) algorithm for each ROI and each patient. The fused contours became atlases for an in-house multi-atlas segmentation. Using leave-one-out test, we generated auto-segmented contours for each ROI and each patient. The auto-segmented contours were compared with the fused contours using the Dice similarity coefficient (DSC) and the mean surface distance (MSD). Results: Inter-observer variability was not obvious for heart, chambers, and aorta but was large for other structures that were not clearly distinguishable on CT image. The average DSC between individual expert contours and the fused contours were less than 50% for coronary arteries and pulmonary vein, and the average MSD were greater than 4.0 mm. The largest MSD of expert contours deviating from the fused contours was 2.5 cm. The mean DSC and MSD of auto-segmented contours were within one standard deviation of expert contouring variability except the right coronary artery. The coronary arteries, vena cava, and pulmonary vein had DSC<70% and MSD>3.0 mm. Conclusion: A set of cardiac atlases was created for cardiac automatic contouring, the accuracy of which was comparable to the variability in expert contouring. However, substantial modification may need for auto-segmented contours of indistinguishable small structures.

60 APPLIED LIFE SCIENCES↗

SU-E-T-676: Reproducibility and Consistency of Two SunNuclear 3D Scanning Tanks

Purpose: To determine if two Sun Nuclear 3D Scanning (SNC 3DS) tanks collect reproducible and consistent data and test the precision of the SNC Dosimetry auto-setup. Methods: Percent depth doses (PDDs) and profiles were collected on two SNC 3DS tanks with a Varian TrueBeam linear accelerator. SNC Dosimetry auto-setup application was used with CC13 ionization chambers. After auto-setup, collimator light field was checked manually against the position of the chamber. Comparing measured data for repeated measurements with tank 1 allowed evaluation of SNC-3DS auto-setup and tank reproducibility. Comparing measured data between tanks 1 and 2 allowed evaluation of consistency between tanks. Results: Preliminary results showed reproducibility of depth of maximum dose (Dmax) of 0.38mm for a 10cmx10cm field and 0.67mm for 30cmx30cm on a single tank. PDD values at 5cm, 10cm, and 20cm depths were reproducible within 0.26%. Consistency of Dmax between tanks was 0.17mm for a 10cmx10cm field and 0.44mm for 30cmx30cm. PDD values at 5cm, 10cm, and 20cmwere consistent within 0.06%. Profiles showed reproducibility in field width within 0.4mm for a 10cmx10cm field and 0.7mm for a 30cmx30cm field. Profiles showed consistency in field width within 0.2mm for 10cmx10cm and 30cmx30cm field sizes. Penumbra width was reproducible and consistent to under 0.5mm except for 30cmx30cm field size at 30cm depth where the reproducibility was 2.2mm and the consistency was 2.6mm. Conclusion: In conclusion, the SNC 3DS tank shows good reproducibility in measured data. Since the tank to tank variation in measured data is within the uncertainty of repeated single tank measurements the tanks also perform consistently.

07 ISOTOPE AND RADIATION SOURCES↗

TU-CD-207-04: Radiation Exposure Comparisons of CESM with 2D FFDM and 3D Tomosynthesis Mammography

Purpose: While mammography is considered the standard for front-line breast cancer screening, image sensitivity and specificity can be affected by factors like dense breast tissue. Contrast-enhanced spectral mammography (CESM) shows promising initial results for dense breasts but comes at the cost of increased dose compared with full-field-digital-mammography (FFDM). The goal of this study is to quantitatively assess the dose increase of CESM in comparison with 2D-FFDM and 3D-Tomo at varying breast thickness. Methods: The experiments were conducted on a Hologic-Selenia-Dimensions system that performed 2D-FFDM, 3D-Tomo and CESM (high and low energies) on regular (50/50) and dense (70/30) breast tissue-mimicking phantoms. Both the phantoms had 6, 1-cm thick slabs (total thickness 6cm), compressed at 20-lbs using an 18×24 paddle. A single exposure was performed for each of the 3 mammo techniques with the following settings: AEC-Auto; Focal Spot-Large; kVp-Auto; mAs- Auto, Target/Filter combination-Auto; AEC Sensor/Exposure compensation Step-2/0. Average glandular dose (AGD) in mGy was obtained and compared as a function of breast thickness (1 – 6 cm) for both the phantom types. Results: The study shows that dose from the total CESM from 50/50 phantom at a breast thickness of a) 4.5 cm was 37.5% higher than 2D-FFDM and 30% higher than 3D-Tomo, b) 6 cm was 36.2% higher than 2D-FFDM and 41% higher than 3D-Tomo. For a dense breast tissue of 70/30 phantom, it was found that CESM dose at a breast thickness of: a) 4.5 cm was 33.3% higher than 2D-FFDM and 28.8% higher than 3D-Tomo, b) 6 cm was 35.4% higher than 2D-FFDM and 48.0% higher than 3D-Tomo. The overall CESM dose for the dense breast phantom was 12.5% higher at 4.5cm and 35% higher at 6 cm compared to the 50/50 phantom. Conclusion: This quantitative comparison study showed that CESM technique has an increased radiation dose compared to conventional 2D-FFDM and 3D-Tomo.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-08: Initial Investigations of Up-Converting Nanoparticles (UCNP) for 3D Tissue Imaging in Optical-ECT

Purpose: Near-IR absorptive up-converting nanoparticles (UCNPs) is a novel contrast for optical-ECT that allows auto-fluorescence-free 3D imaging of labeled cells in a matrix of large (∼1cm{sup 3}) unsectioned normal tissue. This has the potential to image small metastases or dormant cells that is difficult with down-converting fluorescing dyes due to auto-fluorescence. The feasibility of imaging UCNP in agarose phantoms and a mouse lung is demonstrated, aided by a 3D-printed optical-ECT stage designed to excite UCNP in a mouse lung. Methods: The UCNP, NaYF{sub 4}:Yb/Er (20/2%), studied in this work up-converts 980nm light to visible light peaking sharply at ∼540nm. To characterize the UCNP emission as a function of UCNP concentration, cylindrical 2.5%wt agarose phantoms infused with UCNP at concentrations of 25µg/mL and 50µg/mL were exposed to 1.5W 980nm laser coupled to an optical fiber. The fiber was held stably at 1cm above the stage via a custom 3D-printed stage. An optically cleared lung harvested from a BALBc mice was then injected with 100µL of 1mg/mL UCNP solution ex vivo. Tomographic imaging of the UCNP emission in lung was performed. Results: The laser beam tract is visualized within the agarose phantom. A line profile of UCNP emission at 25µg/mL versus 50µg/mL shows that increasing the UCNP concentration increases emission count. UCNPs injected into a cleared mouse lung disperse throughout the respiratory tract, allowing for visualization and 3D reconstruction. Excitation before and after UCNP injection shows the tissue exhibits no auto-fluorescence at 980nm, allowing clear view of the UCNP without any obscuring features such as conventional down-converting fluorescent tags. Conclusion: We confirm that up-conversion in tissue circumvents completely tissue auto-fluorescence, which allowed background-free 3D reconstruction of the UCNP distribution. We also confirm that raising the UCNP concentration increases emission and that UCNPs are retained in agarose samples during the optical clearing process.

60 APPLIED LIFE SCIENCES↗

A Comparative Study of Alternative Controls and Displays for by the Severely Physically Handicapped

A modification of a row/column scanning system was investigated in order to increase the speed and accuracy with which communication aids can be accessed with one or two switches. A selection algorithm was developed and programmed in BASIC to automatically select individuals with the characteristic difficulty in controlling time dependent control and display systems. Four systems were compared: (1) row/column directed scan (2 switches); (2) row/column auto scan (1 switch); (3) row auto scan (1 switch); and (4) column auto scan (1 switch). For this sample population, there were no significant differences among systems for scan time to select the correct target. The row/column auto scan system resulted in significantly more errors than any of the other three systems. Thus, the most widely prescribed system for severely physically disabled individuals turns out for this group to have a higher error rate and no faster communication rate than three other systems that have been considered inappropriate for this group.

Williams, D.↗

Determination of design and operation parameters for upper atmospheric research instrumentation to yield optimum resolution with deconvolution, appendix 2

This thesis reviews the technique established to clear channels in the Power Spectral Estimate by applying linear combinations of well known window functions to the autocorrelation function. The need for windowing the auto correlation function is due to the fact that the true auto correlation is not generally used to obtain the Power Spectral Estimate. When applied, the windows serve to reduce the effect that modifies the auto correlation by truncating the data and possibly the autocorrelation has on the Power Spectral Estimate. It has been shown in previous work that a single channel has been cleared, allowing for the detection of a small peak in the presence of a large peak in the Power Spectral Estimate. The utility of this method is dependent on the robustness of it on different input situations. We extend the analysis in this paper, to include clearing up to three channels. We examine the relative positions of the spikes to each other and also the effect of taking different percentages of lags of the auto correlation in the Power Spectral Estimate. This method could have application wherever the Power Spectrum is used. An example of this is beam forming for source location, where a small target can be located next to a large target. Other possibilities extend into seismic data processing. As the method becomes more automated other applications may present themselves.

Ioup, George E.↗