Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Iterative Response-Surface-Based Approach for Chance-Constrained AC Optimal Power Flow Considering Dependent Uncertainty

A modern power system is characterized by a stochastic variation of the loads and an increasing penetration of renewable energy generation, which results in large uncertainties in its states. These uncertainties bring formidable challenges to the power system planning and operation process. To address these challenges, we propose a cost-effective, iterative response-surface-based approach for the chance-constrained AC optimal power-flow problem that aims to ensure the secure operation of the power systems considering dependent uncertainties. Starting from a stochastic-sampling-based framework, we first utilize the copula theory to simulate the dependence among multivariate uncertain inputs. Then, to reduce the prohibitive computational time required in the traditional Monte-Carlo method, we propose, instead of using the original complicated power-system model, to rely on a polynomial-chaos-based response surface. This response surface allows us to efficiently evaluate the time-consuming power-system model at arbitrary distributed sampled values with a negligible computational cost. This further enables us to efficiently conduct an online stochastic testing for the system states that not only screens out the statistical active constraints, but also assists in a better design of the tightened bounds without using any Gaussian or symmetric assumption. Finally, an iterative procedure is executed to fine-tune the optimal solution that better satisfies a predefined probability. The simulations conducted in multiple test systems demonstrate the excellent performance of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AC Transit Fuel Cell Electric Bus Progress Report (Data Period Focus: Jan. 2020 through Dec. 2020) [Slides]

This report presents early results from a deployment of fuel cell electric buses (FCEBs) operated by Alameda Contra-Costa Transit (AC Transit) in the east bay area of California. The ten FCEBs, produced by New Flyer, feature an electric drive propulsion system powered by a Ballard fuel cell system. The project team is collaborating with the U.S. Department of Energy (DOE) and DOE's National Renewable Energy Laboratory (NREL) to evaluate the buses in revenue service. The goal of this evaluation is to compare the FCEB performance to that of conventional technology and to track progress over time toward meeting the technical targets set by DOE and the Department of Transportation (DOT). The FCEBs were delivered beginning in late-2019. The data period covers January 2020 through July 2020. NREL collects data on two different baseline bus fleets for comparison: five 2017 model year diesel buses and five 2016 model year diesel hybrid buses.

30 DIRECT ENERGY CONVERSION↗

Liquid Crystals-Enabled AC Electrokinetics

Phenomena of electrically driven fluid flows, known as electro-osmosis, and particle transport in a liquid electrolyte, known as electrophoresis, collectively form a subject of electrokinetics. Electrokinetics shows a great potential in microscopic manipulation of matter for various scientific and technological applications. Electrokinetics is usually studied for isotropic electrolytes. Recently it has been demonstrated that replacement of an isotropic electrolyte with an anisotropic, or liquid crystal (LC), electrolyte, brings about entirely new mechanisms of spatial charge formation and electrokinetic effects. This review presents the main features of liquid crystal-enabled electrokinetics (LCEK) rooted in the field-assisted separation of electric charges at deformations of the director that describes local molecular orientation of the LC. Since the electric field separates the charges and then drives the charges, the resulting electro-osmotic and electrophoretic velocities grow as the square of the applied electric field. We describe a number of related phenomena, such as alternating current (AC) LC-enabled electrophoresis of colloidal solid particles and fluid droplets in uniform and spatially-patterned LCs, swarming of colloids guided by photoactivated surface patterns, control of LCEK polarity through the material properties of the LC electrolyte, LCEK-assisted mixing at microscale, separation and sorting of small particles. LC-enabled electrokinetics brings a new dimension to our ability to manipulate dynamics of matter at small scales and holds a major promise for future technologies of microfluidics, pumping, mixing, sensing, and diagnostics.

47 OTHER INSTRUMENTATION↗

Measuring thermal diffusivity of mechanical and optical grades of polycrystalline diamond using an AC laser calorimetry method

Because of its extremely high thermal conductivity, measuring the thermal conductivity or diffusivity of optical-grade diamond can be challenging. Various methods have been used to measure the thermal conductivity of thick diamond films. For the purposes of commercial quality control, the AC laser calorimetry method is appealing because it enables fairly rapid and convenient sample preparation and measurement. In this paper, the method is used to measure the thermal diffusivity of optical diamond. It is found that sample dimensions and measurement parameters are critical, and data analysis must be performed with great care. The results suggest that the method as it is applied to optical-grade diamond could be enhanced by a more powerful laser, higher frequency beam modulation, and post-processing based on 2D thermal simulation.

AC laser calorimetry↗

Exploiting Power Flow Manifold to Solve AC Optimal Power Flow

AC optimal power flow has proven difficult to solve with interior point methods on GPUs. This is largely due to challenging linear algebra problems that current state of the art massively parallel linear solvers struggle with. However, the advent of Riemannian optimization techniques and the fact that the power flow equations form a smooth manifold present an alternative approach. In this talk, we present the basics of Riemannian optimization techniques in which optimization is done directly on a manifold. Then we present computational results showing that Riemannian techniques are capable of producing solutions of comparable quality as interior point methods.

AC optimal power flow↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule-14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched ACDC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

08 - HYDROGEN↗

Theory of AC Loss in Cables with 2G HTS Wire

While considerable work has been done to understand AC losses in power cables made of first generation (1G) high temperature superconductor (HTS) wires, use of second generation (2G) HTS wires brings in some new considerations. The high critical current density of the HTS layer 2G wire reduces the surface superconductor hysteretic losses. Instead, gap and polygonal losses, flux transfer losses in imbalanced two layer cables and ferromagnetic losses for wires with NiW substrates constitute the principal contributions. Current imbalance and losses associated with the magnetic substrate can be minimized by orienting the substrates of the inner winding inward and the outer winding outward.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Droop-Free Distributed Control for AC Microgrids

In this chapter, droop-free distributed control for AC microgrids is discussed. The hierarchical structure of microgrid control is first introduced. Secondary level controls both with and without droop are discussed. Then two droop-free distributed controls are presented: one achieves average voltage regulation and perfect power sharing, and the other one achieves average voltage regulation, voltage variance regulation, and relaxed reactive power sharing. For the latter droop-free control, the relaxed reactive power sharing is achieved through a special distributed generator (DG) that will not participate in reactive power sharing.

Mohiuddin, Sheik Mohammad↗

Study of Dissipative Losses in AC-Biased Mo/Au Bilayer Transition-Edge Sensors

We are developing kilo-pixel arrays of transition-edge sensors (TESs) for the X-ray Integral Field Unit on ESA’s Athena observatory. Previous measurements of AC-biased Mo/Au TESs have highlighted a frequency-dependent loss mechanism that results in broader transitions and worse spectral performance compared to the same devices measured under DC bias. In order to better understand the nature of this loss, we are now studying TES pixels in different geometric configurations. We present measurements on devices of different sizes and with different metal features used for noise mitigation and X-ray absorption. Our results show how the loss mechanism is strongly dependent upon the amount of metal in close proximity to the sensor and can be attributed to induced eddy current coupling to these features. We present a finite element model that successfully reproduces the magnitude and geometry dependence of the losses. Using this model, we present mitigation strategies that should reduce the losses to an acceptable level.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

AC Electrical Properties of MgFe{sub 2−x}Nd{sub x}O{sub 4} (x = 0 to 0.04) for High Frequency Applications

Magnesium ferrite was doped with Nd to get MgFe{sub 2−x}Nd{sub x}O{sub 4} (x = 0 to 0.04). The samples were synthesized by a without water and surfactant (WOWS) sol-gel technique, and pellets were sintered at different temperatures. An inverse spinel structure was confirmed by the X-ray diffraction (XRD) pattern. Lattice constants increased with the increase in Nd doping. Microstructure analysis by SEM shows that particles are spherical in shape. AC electrical properties were studied at room temperature in the frequency range of 20 Hz–3 MHz. A minimum dielectric loss tangent value was achieved with x = 0.02 concentration of Nd, and it is suitable for high-frequency applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of CdTe Addition on the Electrical Properties and AC Susceptibility of YBa{sub 2}Cu{sub 3}O{sub 7−δ} Superconductor

The effect of CdTe addition on YBa{sub 2}Cu{sub 3}O{sub 7−δ}(CdTe){sub x} (x = 0–0.10) has been studied. XRD patterns showed the presence of impurities including CdTe for x ≥ 0.05 wt%. The resistance versus temperature curves showed metallic behavior for all samples. The onset temperature T{sub c onset} for all samples is between 90 and 92 K. The superconducting transition width, ΔT{sub c} = 4 K for all samples except for x = 0.1 wt% where ΔT{sub c} = 6 K. The superconducting transition determined by AC susceptibility measurement also showed little change in T{sub cχ{sup ′}} (between 89 and 92 K). However, the peak temperature T{sub p} of the imaginary part of the susceptibility χ″, showed a drastic decrease for samples with x > 0.05 wt%. This indicated that the superconducting grains were strongly decoupled for x > 0.05 wt% due to the impurities as observed in the XRD pattern. The intergrain critical current density, J{sub c} at T{sub p} for the x = 0 sample is J{sub c} (82 K) = 17 A cm{sup −2}. These results can be useful in the fabrication of semiconductor/YBCO superconductor hybrid systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Ferrimagnetic Cr{sub 2}S{sub 3} on AC Susceptibility and Superconducting Properties of YBa{sub 2}Cu{sub 3}O{sub 7−δ}

Superconductivity and magnetism are mutually exclusive phenomena. This work was carried out to investigate the effect of ferrimagnetic Cr{sub 2}S{sub 3} addition on YBa{sub 2}Cu{sub 3}O{sub 7−δ} superconductor. The solid-state reaction method was used to prepare YBa{sub 2}Cu{sub 3}O{sub 7−δ} (Cr{sub 2}S{sub 3}){sub x} (x = 0 to 0.3 wt%). The samples were characterized by using the four-probe method to measure the electrical resistivity and AC susceptibility to measure the critical temperature, T{sub cχ} and critical current density at the peak temperature T{sub p} of the complex susceptibility, J{sub c}(T{sub p}). The x-ray diffraction (XRD) method was used to determine the phase and structure of the sample. Field emission electron microscopy (FESEM) was used to determine the microstructure. The x = 0.05 sample showed the highest onset transition temperature, T{sub c−onset} (93 K), zero-resistance temperature, T{sub c−zero} (89 K), T{sub cχ} (93 K) and T{sub p} (86 K). Addition of Cr{sub 2}S{sub 3} did not affect the orthorhombic structure. However, the addition of Cr{sub 2}S{sub 3} for x ≥ 0.10 showed some impurity peaks in the XRD patterns. The grain size decreased with Cr{sub 2}S{sub 3} addition. Cr{sub 2}S{sub 3} improved the intergrain coupling and flux pinning as indicated by the increase in J{sub c}(T{sub p}) and T{sub p}. These results are compared with other magnetic and non-magnetic materials addition to YBa{sub 2}Cu{sub 3}O{sub 7−δ}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Critical Current Density and AC Susceptibility of Bi{sub 1.6}Pb{sub 0.4}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10} Superconductor with Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} Nanomaterial

The juxtaposition of superconductivity and magnetism is an interesting research topic due to the exclusivity nature of both phenomena. In this paper, we report the effect of nanosized (~ 5 nm) nickel zinc ferrite Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} (NZFO) on Bi{sub 1.6}Pb{sub 0.4}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10} (Bi-2223) superconductor. Bi-2223 powders were prepared using the co-precipitation method. Samples with starting formula Bi{sub 1.6}Pb{sub 0.4}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}(Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4}){sub x} for x = 0 to 0.1 wt% have been prepared. The structure, microstructure, electrical resistance, and AC susceptibility were determined. The transport critical current density, J{sub ct}, was measured using the 1 μV/cm criterion. The non-added sample sintered for 48 h showed the highest zero resistance temperature, T{sub c-zero} (105 K) and J{sub ct} of 1.83 A cm{sup −2} at 40 K. The x = 0.02 wt% sample sintered for 48 h (T{sub c-zero} = 103 K) showed the highest J{sub ct} of 5.30 A cm{sup −2} at 40 K. The peak temperature of the imaginary part of the complex susceptibility, T{sub p}, increased with sintering time and nanoparticle addition, indicating full flux penetration occurred at higher temperatures and improved intergrain coupling. NZFO nanoparticle did not suppress the transition temperature but it improved the transport critical current density by more than five times indicating it enhanced flux pinning and connectivity between grains in the Bi-2223 phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of the 226 Ra– 230 Th– 234 U and 227 Ac– 231 Pa– 235 U radiochronometers to uranium certified reference materials

Uranium certified reference materials (CRM) issued by New Brunswick Laboratory were subjected to dating using four independent uranium-series radiochronometers. In all cases, there was acceptable agreement between the model ages calculated using the 231 Pa– 235 U, 230 Th– 234 U, 227 Ac– 235 U or 226 Ra– 234 U radiochronometers and either the certified 230 Th– 234 U model date (CRM 125-A and CRM U630), or the known purification date (CRM U050 and CRM U100). Finally, the agreement between the four independent radiochronometers establishes these uranium certified reference materials as ideal informal standards for validating dating techniques utilized in nuclear forensic investigations in the absence of standards with certified model ages for multiple radiochronometers.

226Ra↗

Application of the 226 Ra– 230 Th– 234 U and 227 Ac– 231 Pa– 235 U radiochronometers to UF 6 cylinders

Uranium-series radiometric dating was performed on two well-pedigreed UF 6 cylinder samples containing highly enriched uranium that were in use at the Portsmouth Gaseous Diffusion Plant between the mid-1970s and mid-1980s. Daughter–parent (i.e. 231 Pa– 235 U, 230 Th– 234 U) radiometric ages determined on solid heel materials (e.g. UO 2 F 2 , UF 4 ) recovered from the emptied cylinders are unrealistically old due to the preferential sequestration of progeny isotopes relative to uranium within the solid heels. Furthermore, limited elemental fractionation amongst the progeny isotopes themselves in the heel material allowed for realistic age constraints on the fill dates of the UF 6 cylinders to be extracted from the granddaughter–daughter systems (i.e. 226 Ra– 230 Th, 227 Ac– 231 Pa).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A simulation-based efficiency comparison of AC and DC power distribution networks in commercial buildings

Direct current (DC) power distribution has recently gained traction in buildings research due to the proliferation of on-site electricity generation and battery storage, and an increasing prevalence of internal DC loads. The research discussed in this paper uses Modelica-based simulation to compare the efficiency of DC building power distribution with an equivalent alternating current (AC) distribution. The buildings are all modeled with solar generation, battery storage, and loads that are representative of the most efficient building technology. A variety of paramet ric simulations determine how and when DC distribution proves advantageous. These simulations also validate previous studies that use simpler approaches and arithmetic efficiency models. This work shows that using DC distribution can be considerably more efficient: a medium sized office building using DC distribution has an expected baseline of 12% savings, but may also save up to 18%. In these results, the baseline simulation parameters are for a zero net energy (ZNE) building that can island as a microgrid. DC is most advantageous in buildings with large solar capacity, large battery capacity, and high voltage distribution.

24 POWER TRANSMISSION AND DISTRIBUTION↗