Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Initial tests of Accelerator Mass Spectrometry with the Argonne Gas-Filled Analyzer and the commissioning of the MONICA detector

As the scope of Accelerator Mass Spectrometry (AMS) expands, there is an increased need to extend the capability of isobaric separation to the medium-heavy mass region. Existing AMS facilities are limited in their ability to separate radioactive nuclei in the A = 100–200 range of interest from their neighboring stable isobars, as such measurements require higher energies than available in most facilities. ATLAS is one of the highest energy system used for AMS based experiments and has enabled isobaric discrimination for medium to heavy nuclides, notably via the Gas-Filled Magnet technique. Further, a preparatory experiment performed in November, 2019, successfully demonstrated isobaric separation of 92 Zr- 92 Mo using the Argonne Gas-Filled Analyzer (AGFA) with high magnetic rigidity. Since that time, MONICA, an eight-anode ionization chamber that measures both energy loss and position with two sets of split anodes, has been developed to aid in AMS experiments at AGFA and has undergone four commissioning runs at the Nuclear Science Laboratory at the University of Notre Dame utilizing Si, Fe/Ni, and Mn beams. This report presents the AGFA AMS run (November 2019) and the subsequent commissioning runs of the MONICA detector, including preliminary measurements on the long-lived isotopes 39 Ar (268 y) and for the first time on 42 Ar (33 y).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass-Analyzed Threshold Ionization (MATI) Spectroscopy of Atoms and Molecules using VUV Synchrotron Radiation

Mass-analyzed threshold ionization (MATI) spectroscopy using synchrotron radiation (Advanced Light Source, Lawrence Berkeley National Laboratory) has been performed for Ar, N2, O2, N2O, H2O, C2H2, and C6H6. MATI allows for a better determination of ionization energies compared to those derived from photoionization efficiency curves traditionally used in synchrotron photoionization mass spectrometry. The separation of the long-lived Rydberg state from the directly-formed prompt ion, essential for a meaningful MATI spectrum, has been accomplished by employing an arrangement of ion optics coupled to unique electric-field pulsing schemes. For Ar, a number of resolved bands below the ionization energy are observed, and these are ascribed to high-n,l Rydberg states prepared in the MATI scheme. The first vibrational stateresolved MATI spectra of N2 and O2 are reported and spectral characteristics are discussed in comparison with previously-reported threshold photoelectron spectroscopic studies. While MATI performed with synchrotron radiation is intrinsically less sensitive compared to laser based sources, this work demonstrates that MATI spectroscopy performed with widely tunable VUV radiation is a complementary technique for studying the ionization spectroscopy of polyatomic molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pellet charge exchange helium measurement using neutral particle analyzer in large helical device

It is very important to investigate the confinement of {alpha} particles, which will be produced by nuclear reactions in ITER and fusion reactors. The pellet charge exchange (PCX) measurement is one of the most powerful methods because it can directly provide the profile of the {alpha} particle energy spectra in a plasma. In the large helical device, PCX using tracer encapsulated solid pellet (TESPEL) has been tried in many hydrogen and helium plasmas, including helium accelerated by using the cyclotron resonance heating. In the PCX, we use the compact neutral particle analyzer without simultaneous mass separation ability. The helium particle measurement can be achieved by the application of voltage in the condenser plate. The scattering of hydrogen particle is carefully considered during the estimation of the helium amount. The radial helium profiles can also be obtained by comparing four TESPEL injection shots with/without higher harmonic fast wave heating and at applied plate voltages for He or H, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An optimized three-dimensional linear-electric-field time-of-flight analyzer

In situ measurements of the dynamics and composition of space plasmas have greatly improved our understanding of the space environment. In particular, mass spectrometers that use a combination of electrostatic analyzers and time-of-flight systems can identify revealing dynamic and compositional characteristics of ions, and thus constrain their sources and the physical processes relevant for their transport. We demonstrate an optimized design of a linear-electric-field time-of-flight technology that can be used to obtain a high signal to noise: ions that follow an energy-isochronous oscillation within the instrument impact an emissive plate and cause secondary electrons to be sent toward the detector, triggering a high-resolution measurement. By focusing these secondary electrons to a central area on a position-sensitive anode, their signals are separated from ions and neutrals that do not experience energy-isochronous motion. Using their impact positions, the high mass resolution measurements are easily distinguished from other signals on the detector, leading to very favorable signal-to-noise ratios. This optimization provides an improvement to existing technologies without increasing the instrument size or complexity, and uses a novel time-of-flight circuit that combines timing and position information from many signals and ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflections of ions in electrostatic analyzers: A case study with New Horizons/Solar Wind Around Pluto

Electrostatic analyzers (ESAs), in various forms, are used to measure plasma in a range of applications. In this article, we describe how ions reflect from the interior surfaces of an ESA, the detection of which constitutes a fundamentally nonideal response of ESAs. We demonstrate this effect by comparing laboratory data from a real ESA-based space instrument, the Solar Wind Around Pluto (SWAP) instrument, aboard the NASA New Horizons spacecraft, to results from a model based on quantum mechanical simulations of particles reflected from the instrument's surfaces combined with simulations of particle trajectories through the instrument's applied electrostatic fields. Thus, we show, for the first time, how reflected ions in ESAs lead to nonideal effects that have important implications for understanding the data returned by these instruments, as well as for designing new low-background ESA-based instruments. Specifically, we show that the response of SWAP widens considerably below a level of 10{sup -3} of the peak response. Thus, a direct measurement of a plasma distribution with SWAP will have an energy-dependent background on the order of {<=}10{sup -3} of the peak of the signal due to that distribution. We predict that this order of magnitude estimate for the background applies to a large number of ESA-based instruments because ESAs operate using a common principle. However, the exact shape of the energy-dependent response will be different for different instruments. The principle of operation is that ions outside the ideal range of energy-per-charge are deflected into the walls of the ESA. Therefore, we propose that a new design paradigm is necessary to mitigate the effect of ion reflections and thus accurately and directly measure the energy spectrum of a plasma using ESAs. In this article, we build a framework for minimizing the effect of ion reflections in the design of new ESAs. Through the use of existing computer simulation software, a design team can use our method to quantify the amount of reflections in their instrument and iteratively change design parameters before fabrication, conserving resources. A possible direction for the new design paradigm is having nonsolid walls of the ESA, already used in some applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The geometric factor of electrostatic plasma analyzers: A case study from the Fast Plasma Investigation for the Magnetospheric Multiscale mission

We report our findings comparing the geometric factor (GF) as determined from simulations and laboratory measurements of the new Dual Electron Spectrometer (DES) being developed at NASA Goddard Space Flight Center as part of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale mission. Particle simulations are increasingly playing an essential role in the design and calibration of electrostatic analyzers, facilitating the identification and mitigation of the many sources of systematic error present in laboratory calibration. While equations for laboratory measurement of the GF have been described in the literature, these are not directly applicable to simulation since the two are carried out under substantially different assumptions and conditions, making direct comparison very challenging. Starting from first principles, we derive generalized expressions for the determination of the GF in simulation and laboratory, and discuss how we have estimated errors in both cases. Finally, we apply these equations to the new DES instrument and show that the results agree within errors. Thus we show that the techniques presented here will produce consistent results between laboratory and simulation, and present the first description of the performance of the new DES instrument in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved ion energy distribution measurements using an advanced neutral particle analyzer on the MST reversed-field pinch

An advanced neutral particle analyzer (ANPA) capable of simultaneously measuring hydrogen and deuterium ions of energies up to 45 keV has recently been developed for use on the Madison Symmetric Torus. The charge-to-mass separation allows for separate analysis of bulk deuterium ions and hydrogen ions injected with a 1 MW, 25 keV neutral beam. Orientation of the ANPA allows sampling of different regions of ion velocity space; a radial viewport favors collection of ions with high v{sub Up-Tack }/ Double-Vertical-Line v Double-Vertical-Line while a recently installed tangential viewport favors ions with high v{sub Double-Vertical-Line Double-Vertical-Line }/ Double-Vertical-Line v Double-Vertical-Line , such as those from the core-localized fast ion population created by the neutral beam. Signals are observed in the ANPA's highest energy channels during periodic magnetic reconnection events, which are drivers of anisotropic, non-Maxwellian ion energization in the reversed-field pinch. ANPA signal strength is dependent on the background neutral density, which also increases during magnetic reconnection events, so careful analysis must be performed to identify the true change in the ion distribution. A Monte Carlo neutral particle tracing code (NENE) is used to reconstruct neutral density profiles based on D{sub {alpha}} line emission, which is measured using a 16-chord filtered photodiode array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact solid-state neutral particle analyzer in current mode

Solid state neutral particle analyzer (ssNPA) arrays are operated in current mode on the DIII-D tokamak and the National Spherical Torus Experiment (NSTX). Compared with conventional pulse-counting NPAs, current-mode operation sacrifices energy resolution to obtain economical, high-bandwidth, pitch-angle resolved measurements. With the success from a new three-channel near-vertical-view current mode ssNPA on DIII-D, the apertures on an existing array on NSTX were expanded to increase the particle influx. The sightlines of both arrays intersect heating beams, enabling both active and passive charge exchange measurements. The spatial resolution at beam intersection is typically 5 cm on both devices. Directly deposited ultra-thin foils on the detector surface block stray photons below the energy of 1 keV and also set low energy threshold about 25 keV for deuterium particle detection. Oscillations in neutral flux produced by high frequency magnetohydrodynamics (MHD) instabilities are readily detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An initial measurement of a fast neutral spectrum for ion cyclotron range of frequency heated plasma using two-channel compact neutral particle analyzers in KSTAR

The accurate measurement of fast neutral particles from high energy ion tails is very important since it is a measure of ion cyclotron range of frequency (ICRF) or neutral beam (NB) ion heating. In KSTAR, fast neutral measurements have been carried out using a compact neutral particle analyzer based on the silicon photo diode since 2010. As a result, the fast neutral spectrum was observed consistent with the ion temperature, diamagnetic energy, and neutron flux in 2011. However, there was fast neutral count beyond the injected neutral beam energy in NB-only heating. Since it is difficult to expect the count unless the temperature is high enough to diffuse the fast ions beyond the beam energy it was required to identify what it is. During the 2012 campaign, the two-channel diode detectors with and without a particle stopper were used to distinguish fast neutral counts and other counts by a hard X-ray or neutrons. As a result, it was confirmed that the high energy component beyond the beam energy originated from a hard X-ray or neutrons. Finally, it was observed that faster neutrals are generated by ICRF heating and enhanced by electron cyclotron heating compared to NB-only heating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of multichannel analyzer using sound card ADC for nuclear spectroscopy system

This paper describes the development of Multi-Channel Analyzer (MCA) using sound card analogue to digital converter (ADC) for nuclear spectroscopy system. The system was divided into a hardware module and a software module. Hardware module consist of detector NaI (Tl) 2” by 2”, Pulse Shaping Amplifier (PSA) and a build in ADC chip from readily available in any computers’ sound system. The software module is divided into two parts which are a pre-processing of raw digital input and the development of the MCA software. Band-pass filter and baseline stabilization and correction were implemented for the pre-processing. For the MCA development, the pulse height analysis method was used to process the signal before displaying it using histogram technique. The development and tested result for using the sound card as an MCA are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On geometric factors for neutral particle analyzers

Neutral particle analyzers (NPA) detect neutralized energetic particles that escape from plasmas. Geometric factors relate the counting rate of the detectors to the intensity of the particle source. Accurate geometric factors enable quick simulation of geometric effects without the need to resort to slower Monte Carlo methods. Previously derived expressions [G. R. Thomas and D. M. Willis, “Analytical derivation of the geometric factor of a particle detector having circular or rectangular geometry,” J. Phys. E: Sci. Instrum. 5(3), 260 (1972); J. D. Sullivan, “Geometric factor and directional response of single and multi-element particle telescopes,” Nucl. Instrum. Methods 95(1), 5–11 (1971)] for the geometric factor implicitly assume that the particle source is very far away from the detector (far-field); this excludes applications close to the detector (near-field). The far-field assumption does not hold in most fusion applications of NPA detectors. We derive, from probability theory, a generalized framework for deriving geometric factors that are valid for both near and far-field applications as well as for non-isotropic sources and nonlinear particle trajectories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the neutral particle analyzers for the TJ-II stellarator

The TJ-II stellarator, a magnetically confined plasma device, is equipped with a broad range of diagnostics for plasma characterization. These include 4 neutral particle analyzers (NPAs), consisting of two Acord-12's, to perform poloidal measurements, plus a compact NPA, and an Acord-24, these in tangential viewing positions. The Acord-12's were originally equipped with two rows of 6 channels each, one for hydrogen neutrals and the other for deuterium neutrals but were changed to a single row of 12 detectors for hydrogen, the principal working gas in TJ-II. With this upgrade the resultant improved energy resolution spectrum has allowed more reliable ion temperature estimates to be obtained. Here we present the upgrades undertaken and present results to demonstrate the improved performance of this diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of solid state neutral particle analyzer array for National Spherical Torus Experiment-Upgrade

A new compact, multi-channel Solid State Neutral Particle Analyzer (SSNPA) diagnostic based on silicon photodiode array has been designed and is being fabricated for the National Spherical Torus Experiment-Upgrade (NSTX-U). The SSNPA system utilizes a set of vertically stacked photodiode arrays in current mode viewing the same plasma region with different filter thickness to obtain fast temporal resolution (∼120 kHz bandwidth) and coarse energy information in three bands of >25 keV, >45 keV, and >65 keV. The SSNPA system consists of 15 radial sightlines that intersect existing on-axis neutral beams at major radii between 90 and 130 cm, 15 tangential sightlines that intersect new off-axis neutral beams at major radii between 120 and 145 cm. These two subsystems aim at separating the response of passing and trapped fast ions. In addition, one photodiode array whose viewing area does not intersect any neutral beams is used to monitor passive signals produced by fast ions that charge exchange with background neutrals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Labview based data acquisition and multichannel analyzer software for radioactive particle tracking system

A DAQ (data acquisition) software called RPTv2.0 has been developed for Radioactive Particle Tracking System in Malaysian Nuclear Agency. RPTv2.0 that features scanning control GUI, data acquisition from 12-channel counter via RS-232 interface, and multichannel analyzer (MCA). This software is fully developed on National Instruments Labview 8.6 platform. Ludlum Model 4612 Counter is used to count the signals from the scintillation detectors while a host computer is used to send control parameters, acquire and display data, and compute results. Each detector channel consists of independent high voltage control, threshold or sensitivity value and window settings. The counter is configured with a host board and twelve slave boards. The host board collects the counts from each slave board and communicates with the computer via RS-232 data interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First results from solid state neutral particle analyzer on experimental advanced superconducting tokamak

Full function integrated, compact solid state neutral particle analyzers (ssNPA) based on absolute extreme ultraviolet silicon photodiode have been successfully implemented on the experimental advanced superconducting tokamak to measure energetic particle. The ssNPA system has been operated in advanced current mode with fast temporal and spatial resolution capabilities, with both active and passive charge exchange measurements. It is found that the ssNPA flux signals are increased substantially with neutral beam injection (NBI). The horizontal active array responds to modulated NBI beam promptly, while weaker change is presented on passive array. Compared to near-perpendicular beam, near-tangential beam brings more passive ssNPA flux and a broader profile, while no clear difference is observed on active ssNPA flux and its profile. Significantly enhanced intensities on some ssNPA channels have been observed during ion cyclotron resonant heating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel data interpretation method for DIII-D divertor retarding field energy analyzer with 3-D particle-in-cell simulations

A novel data interpretation process that utilizes comprehensive particle-in-cell (PIC) simulations is developed for the new retarding field energy analyzer (RFEA) currently being constructed at DIII-D for the lower divertor using the Divertor Material Evaluation System. Furthermore, this probe is expected to survive a heat load of up to 100 MW/m 2 for up to 5 s and reliably measure the main ion temperature (T i ) on the divertor target ranging from 10 to 200 eV. These extreme conditions posed significant engineering limitations on the probe geometry, thus extensive validation work has been performed. The conventional fitting method for the RFEA I–V characteristics is based on a simplified 1-D model without considering the ion space charge inside the probe cavity and may not be sufficient for probes designed for the DIII-D divertor environment. In this article, a more realistic description of the particle propagation process within the RFEA cavity is achieved by including both 3-D geometric effects and ion space charge in the PIC simulations, and the capability to reconstruct the ion energy distribution functions is demonstrated with reasonable consistency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A MEMS dynamic mechanical analyzer for in situ viscoelastic characterization of 3D printed nanostructures

Cellular metamaterial structures with sub-micron features have shown the ability to become excellent energy absorbing materials for impact mitigation due to the enhanced mechanical properties of materials at the nanoscale. However, in order to optimize the design of these energy absorbing metamaterial structures we need to be able to measure the dynamic properties of the sub-micron features such as storage and loss moduli and the loss factor. Therefore, at scale testing is required to capture the scale, temperature, and strain rate dependent material properties of these nanoscale materials. This study presents the design, fabrication, and calibration of a MEMS-based dynamic mechanical analyzer (DMA) that can be directly integrated with the two photon lithography (TPL) process commonly used to fabricate metamaterial structures with nanoscale features. The MEMS-based DMA consists of a chevron style thermal actuator used to generate a tensile load on the structure and two differential capacitive sensors on each side of the structure used to measure load and displacement. This design demonstrated 1.5 ± 0.75 nm displacement resolution and 104 ± 52 nN load resolution, respectively. Dynamic mechanical analysis was successfully conducted on a single nanowire feature printed between the load and displacement stages of the MEMS device with testing frequencies ranging between 0.01–10 Hz and testing temperatures ranging between 22 °C–47 °C. These initial tests on an exemplar TPL part demonstrate that the printed nanowire behaves as a viscoelastic material wherein the transition from glassy to viscous behavior has already set in at the room temperature.

42 ENGINEERING↗

Progress in modelling fast-ion D-alpha spectra and neutral particle analyzer fluxes using FIDASIM

FIDASIM is a code that models signals produced by charge-exchange reactions between neutrals and ions (both fast and thermal) in magnetically confined plasmas. With the ion distribution function as input, the code predicts the efflux to a neutral particle analyzer diagnostic and the photon radiance of Balmer-alpha light to a fast-ion D α diagnostic, in addition to many other related quantities. A new, parallelized version of the Monte Carlo code FIDASIM has been developed in Fortran90 that is substantially faster than the original interactive data language version. Modified algorithms include more accurate treatments of the time dependent collisional-radiative equations that describe neutral energy levels, of the cloud of ‘halo’ neutrals that surround the injected neutral beam, and of finite Larmor radius effects. Enhanced physics capabilities include modelling ‘passive’ signals from cold edge neutrals, the ability to treat general three-dimensional magnetic confinement configurations, and calculations of diagnostic-specific weight functions that enable tomographic reconstructions of the fast-ion distribution function. Neutral beam attenuation, beam emission, and fast-ion birth profiles are also modelled. Finally, the new algorithms have been successfully validated against experimental data and new features have been tested through benchmarks between two independently developed versions of the code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗