Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Laser wire beam profile monitor in the Spallation Neutron Source (SNS) superconducting linac

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is an accelerator based neutron scattering facility. The SNS uses the large scale high energy superconducting linac (SCL) to provide high beam power utilizing hydrogen ion (H-) beams. For the diagnostics of high-brightness H- beam in the SCL, nonintrusive methods have to be developed. This paper describes design, implementation, theoretical analysis and experimental demonstration of a nonintrusive profile monitor system based on photodetachment, also known as laser wire, installed in the SNS-SCL. The SNS laser wire system is the largest of its kind with a capability of measuring both horizontal and vertical profiles of an operational H- beam at each of the 23 cryomodule stations along the SCL beam line by employing a single light source. Presently 9 laser wire stations have been commissioned which measures H- beam profiles at 9 different locations corresponding to energy levels of 200 MeV to 1 GeV. The laser wire diagnostics has no moving parts inside the beam pipe, causes no contamination on the superconducting surface, and can be run parasitically on an operational neutron production H- beam.

43 PARTICLE ACCELERATORS↗

Constraining Cross Section and Beam Systematics for Future NOvA Sterile Neutrino Search

he NOvA (NuMI Off-axis $\nu_e$ Appearance) experiment measures neutrino oscillations in a nearly pure muon (anti)neutrino beam over a 810 km baseline. We search for sterile neutrino driven oscillations in both neutral current (NC) and charged current (CC) muon neutrino samples. A deficit of NC interactions at the Far Detector could occur since sterile neutrinos do not couple to the Z boson. A modulation of the muon neutrino disappearance probability is possible due to a new mass splitting. The NuMI beam line is capable of running in forward or reverse horn current modes, which creates a neutrino or antineutrino beam, respectively. Samples collected in forward horn current (FHC) or reverse horn current (RHC) modes are subject to beam optics uncertainties, in addition to cross section and hadron production uncertainties. We explore the ategories. To tackle reduction of cross section uncertainties, we study how splitting the neutral current (NC) samples can impact the systematic reduction and its implications on oscillation parameters, leveraging results from Monte Carlo simulations. Additionally, we look at the possibility of using a $\nu$-on-e scattering sample. The $\nu$-on-e scattering process has minimal cross section uncertainties compared to that of neutrino-nucleus interactions, which can help constrain the overall flux normalizations. Using both the ZHC sample, NC split sample, and $\nu$-on-e scattering sample jointly with FHC samples would reduce the focusing uncertainties and the hadron production uncertainties in the future sterile analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final 6D Muon Ionization Colling using Strong Focusing Quadrupoles

Abstract Low emittance muon beam lines and muon colliders are potentially a rich source of BSM physics for future exper- imenters. A muon beam normalized emittance of ax,y,z = (280, 280, 1570)µm has been achieved in simulation with short solenoids and a betatron function of 3 cm. Here we use ICOOL and MAD-X to explore using a 400 MeV/c muon beam and strong focusing quadrupoles to achieve a normalized transverse emittance of 100 µm and complete 6D cooling. The low beta regions, as low as 5 mm, produced by the quadrupoles are occupied by dense, low Z absorbers, such as lithium hydride or beryllium, that cool the beam transversely. Equilibrium transverse emittance is linearly proportional to the transverse betatron function. Reverse emittance exchange with septa and/or wedges is then used to decrease transverse emittance from 100 to 25 µm at the expense of longitudinal emittance for a high energy lepton collider. Cooling challenges include chromaticity correction, ssband overlap, quadrupole acceptance, and staying in phase with RF.

43 PARTICLE ACCELERATORS↗

Fiber Optic Picosecond Laser Pulse Transmission Line for Hydrogen Ion Beam Profile Measurement

We present a fiber optic laser pulse transmission line for non-intrusive longitudinal profile measurement of the hydrogen ion (H-) beam at the front-end of the Spallation Neutron Source (SNS) accelerator. The 80.5 MHz, 2.5 ps, multi-killowatt optical pulses are delivered to the accelerator beam line through a large mode area polarization maintaining optical fiber to ensure a high measurement stability. The transmission efficiency, output laser beam quality, pulse jitter and pulse width broadening over a 100-ft fiber line are experimentally investigated. A successful measurement of the H- beam microbunch (~130 ps) profile is obtained. Our experiment is the first demonstration of particle beam profile diagnostics using fiber optic laser pulse transmission line.

fiber optic↗

Exact solution of multi-bunch instabilities for ultra-relativistic constant energy bunches in particle accelerators

In particle accelerators the multi-bunch beams of charged particles excite electromagnetic wakefields in the accelerating cavities and other beam-line components. These wakefields may cause instability in the longitudinal and transverse motion of these bunches leading to the beam loss. Thus, the analysis of such multi-bunch effects is critical in any accelerator design. Here in this paper, we present a new analytical method to exactly describe the multi-bunch transverse instabilities for ultra-relativistic electron bunches coasting at a constant energy through a uniform beam-focusing system. We discuss two cases: same bunch energy for all bunches and different energy from bunch to bunch. For the first case the solution is based on a special class of polynomials, while for the second case the solution is a finite sum of sinusoidal functions. We demonstrate the use of this approach with examples and compare the results of a numerical differential equation solver against our rigorous results. Our method could also be applied to the analysis of beam breakup within a single bunch. This approach can be extended beyond accelerator physics to study other many-body systems where an $n\mathrm{th}$ body is affected by only the preceding $n-1$ bodies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resonant Raman scattering of polarized and unpolarized x-ray radiation from Mg, Al, and Si

The x-ray resonant Raman scattering (RRS) effect of polarized and unpolarized radiation in the vicinity of the 1s absorption threshold of low-Z elements such as magnesium, aluminum, and silicon is investigated. For the polarized and tunable exciting x-ray radiation the plane grating monochromator (PGM) beam line at the PTB laboratory in the BESSY II synchrotron radiation facility was employed, while unpolarized x-ray beams were induced by 1-MeV proton beam irradiation on various pure thick targets. For the latter case, a novel proton-induced x-ray fluorescence scattering chamber was designed and installed at the Tandem accelerator laboratory of the Institute of Nuclear Physics at N.C.S.R. 'Demokritos'. The total RRS cross sections deduced from both independent excitation modes were found to be in a good agreement, within the experimental uncertainties. The predictions of the existing theory with respect to the dependence of the RRS to the incident beam polarization state is calculated and discussed with respect to the experimental results.

36 MATERIALS SCIENCE↗

Solid-solid phase transition measurements in iron

Previously, dynamic experiments on iron have observed a non-zero transition time and width in the solid-solid {alpha}-{var_epsilon} phase transition. Using Proton Radiography at the Los Alamos Neutron Science Center, we have performed plate impact experiments on iron to further study the {alpha}-{var_epsilon} phase transition which occurs at 13GPa. A 40mm bore powder gun was coupled to a proton radiography beam line and imaging system and synchronized to the impact of the projectile on the target sample with the proton beam pattern. A typical experimental configuration for the iron study, as shown below in 3 color-enhanced radiographs, is a 40mm diameter aluminum sabot impacting a 40mm diameter of polycrystalline ARMCO iron. The iron is backed by a sapphire optical window for velocimetry measurements. The aluminum flyer on the left of the iron is barely visible for visual display purposes. Direct density jumps were measured which corresponded to calculations to within 1% using a Wondy mUlti-phase equation of state model. In addition, shock velocities were measured using an edge fitting technique and followed that edge movement from radiograph to radiograph, where radiographs are separated in time by 500 ns. Preliminary measurements give a shock velocity (P1 wave) of 5.251 km/s. The projectile velocity was 0.725 km/s which translate to a peak stress of 17.5 GPa. Assuming the P1 wave is instantaneous, we are able to calibrate the chromatic, motion, object and camera blur by measuring the width of the P1 wave. This approximation works in this case since each of the two density jumps are small compared to the density of the object. Subtracting the measured width of the P1 wave in quadrature from the width of the P2 wave gives a preliminary measurement of the transition length of 265 {mu}m. Therefore, a preliminary measured phase transition relaxation time {tau} = transition length/u{sub s} = 265 {mu}m/5.251 km/s = 50 ns. Both Boettger and Jensen conclude that the transition rate and likely the transition mechanisms depend on the impact stress and the sample thickness. Since Proton Radiography can measure directly the transition length as well as the shock velocity, a transition time can be directly calculated. With higher higher energy protons we have better resolution of the measured width and edge locations. This will allow a more precise measurement of phase transition relaxation time. We propose to perform a series of experiments to measure the phase transition relaxation time, {tau}, as a function of drive and sample size.

36 MATERIALS SCIENCE↗

Kinetics of Solid-Solid Phase Transition in Iron (u)

Previously, dynamic experiments on iron have observed a non-zero transition time and width in the solid-solid {alpha}-{var_epsilon} phase transition. Using Proton Radiography at the los Alamos Neutron Science Center, we have performed plate impact experiments on iron to further study the {alpha}-{var_epsilon} phase transition which occurs at 13GPa. A 40mm bore powder gun was coupled to a proton radiography beam line and imaging system and synchronized to the impact of the projectile on the target sample with the proton beam pattern. A typical experimental configuration for the iron study, as shown below in 3 color-enhanced radiographs, is a 40mm diameter aluminum sabot impacting a 40mm diameter of polycrystalline ARMCO iron. The iron is backed by a sapphire optical window for velocimetry measurements. The aluminum flyer on the left of the iron is barely visible for visual display purposes. Direct density jumps were measured which corresponded to calculations to within 1% using a Wondy multi-phase equation of state model. In addition, shock velocities were measured using an edge fitting technique and followed that edge movement from radiograph to radiograph, where rad iographs are separated in time by 500 ns. Preliminary measurements give a shock velocity (P1 wave) of 5.251 km/s. The projectile velocity was 0.725 km/s which translate to a peak stress of 17.5 GPa. Assuming the P1 wave is instantaneous, we are able to calibrate the chromatic, motion, object and camera blur by measuring the width of the P1 wave. This approximation works in this case since each of the two density jumps are small compared to the density of the object. Subtracting the measured width of the P1 wave in quadrature from the width of the P2 wave gives a preliminary measurement of the transition length of 265 {micro}m. Therefore, a preliminary measured phase transition relaxation time {tau} = transition length/u{sub s} = 265 {micro}m/5.251 km/s = 50 ns. Both Boettger1 & Jensen2 conclude that the transition rate and likely the transition mechanisms depend on the impact stress and the sample thickness. Since Proton Radiography can measure directly the transition length as well as the shock velocity, a transition time can be directly calculated. We propose to perform a series of experiments to measure the phase transition relaxation time, 1, as a function of drive, sample size and crystal orientation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synchrotron Facilities and Free Electron Lasers

Synchrotron radiation (SR) is electromagnetic radiation emitted when a charged particle travels along a curved trajectory. Initially encountered as a nuisance around orbits of high energy synchrotron accelerators, it gradually became an indispensable research tool in many applications: crystallography, X-ray lithography, micromechanics, structural biology, microprobe X-ray experiments, etc. So-called first generation SR sources were exploiting SR in parasitic mode at electron accelerators built to study particle collisions. The second generation of SR sources was the first facilities solely devoted to SR production. They were optimized to achieve stable high currents in the accelerator ring to achieve substantially higher photon flux and to provide a large number of SR beam lines for users. Third generation sources were further optimized for increased brilliance, i.e. with photons densely packed into a beam of very small cross-sectional area and minimal angular divergence (see the Appendix for more detailed definitions of flux, brightness and brilliance) and makes extensive use of the insertion devices such as wigglers and undulators. Free Electron Lasers (FELs), the fourth generation SR sources, open new research possibilities by offering extremely short pulses of extremely bright and coherent radiation. The number of SR sources around the world now probably exceeds 100. These facilities vary greatly in size, energy of the electron (or positron) beams, range of photon energies and other characteristics of the photon beams produced. In what follows we will concentrate on describing some common aspects of SR facilities, their operation modes and specific radiation protection aspects.

43 PARTICLE ACCELERATORS↗

Effects associated with nanostructure fabrication using in situ liquid cell TEM technology

We studied silicon, carbon, and SiC x nanostructures fabricated using liquid-phase electron-beam-induced deposition technology in transmission electron microscopy systems. Nanodots obtained from fixed electron beam irradiation followed a universal size versus beam dose trend, with precursor concentrations from pure SiCl 4 to 0 % SiCl 4 in CH 2 Cl 2 , and electron beamintensity ranges of two orders of magnitude, showing good controllability of the deposition. Secondary electrons contributed to the determination of the lateral sizes of the nanostructures, while the primary beam appeared to have an effect in reducing the vertical growth rate. These results can be used to generate donut-shaped nanostructures. Using a scanning electron beam, line structures with both branched and unbranched morphologies were also obtained. As a result, the liquid-phase electron-beam induced deposition technology is shown to be an effective tool for advanced nanostructured material generation.

36 MATERIALS SCIENCE↗

Uniform Beam Distributions Of Charged Particle Beams

The use of octupole elements was originally suggested [1] to transform the transverse Gaussian distribution of a charged particle beam into a uniform beam distribution having rectangular cross section. The first experimental realization of this concept was materialized at the Radiation Effects Facility (REF) of the Brookhaven National Laboratory (BNL)[2] where the transverse Gaussian distribution of a 200 MeV H{sup -} beam was transformed into a rectangular uniform distribution. Later, the beam line of the NASA Space Radiation Laboratory (NSRL) facility [3,4] built at BNL, was specifically designed to generate uniform beam distributions with rectangular cross sections, in both, the horizontal and vertical directions, at the location of the target. The NSRL facility generates uniform beam distributions of various nuclear species, which may vary in energy, and also vary in size of the uniform beam distribution. We will present an overview of the method to generate uniform beam distributions, show some results from the NSRL facility, and suggest other possibilities for generating such beam distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feedback control of stored energy and rotation with variable beam energy and perveance on DIII-D

Design and testing of a new method for real-time control on DIII-D using the new voltage and perveance variation capability of DIII-D's neutral beam injection system is presented. The approach enables control of power, torque, stored energy, and rotation without requiring pulse-width modulation of the beams. Such modulations are perturbative to experiments, can cause beam reliability problems, and could potentially damage or fatigue accelerator grids, especially looking forward to active control of long-pulse devices and reactors. Here, the control algorithm accounts for beam line loss mechanisms and includes approaches that address the complexity of having three manipulated variables for each of the eight beams and compensate for the rate and magnitude limits affecting the voltage and perveance actuators. Results are presented that demonstrate the performance of the approach in the first feedback control experiments to use the expanded controllability of the DIII-D beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search For Short-Baseline Oscillations At The NOvA Near Detector

Anomalous results from past neutrino experiments have been interpreted as potential evidence for an additional sterile neutrino with a mass on order of 1 eV, but this evidence remains inconclusive. The NOvA Near Detector is a 293 ton almost fully-active fine-grained liquid scintillator detector, that was designed for electron-neutrino identification. The detector is placed along the Fermilab NuMI beam line 1 km from the target. At this off-axis angle, the detector is exposed to a narrow band beam peaked at 2 GeV. Therefore the NOvA Near Detector will see neutrinos with an L/E range that is sensitive to oscillations between active neutrinos and light sterile neutrinos. In this thesis, I discuss NOvA sensitivity from the joint electron-neutrino appearance and muon-neutrino disappearance analysis search for short-baseline sterile neutrino mixing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ion Dynamic Capture Experiments With The High Performance Antiproton Trap (HiPAT)

To take the first step towards using the energy produced from the matter-antimatter annihilation for propulsion applications, the NASA Marshall Space Flight Center (MSFC) Propulsion Research Center (PRC) has initiated a research activity examining the storage of low energy antiprotons. The High Performance Antiproton Trap (HiPAT) is an electromagnetic system (Penning-Malmberg design) consisting of a 4 Tesla superconductor, a high voltage electrode confinement system, and an ultra high vacuum test section. It has been designed with an ultimate goal of maintaining 10(exp 12) charged particles with a half-life of 18 days. Currently, this system is being evaluated experimentally using normal matter ions that are cheap to produce, relatively easy to handle, and provide a good indication of overall trap behavior (with the exception of assessing annihilation losses). The ions are produced via a positive hydrogen ion source and transported to HiPAT in a beam line equipped with electrostatic optics. The optics serve to both focus and gate the incoming ions, providing microsecond-timed beam pulses that are dynamically captured by cycling the HiPAT forward containment field like a "trap door". Initial dynamic capture experiments have been successfully performed with beam energy and currents set to 1.9 kV and 23 micro-amps, respectively. At these settings up to 2x10(exp 9) ions have been trapped during a single dynamic cycle.

Martin, James↗

Thomson scattering diagnostic system design for the Compact Toroidal Hybrid experiment

A new Thomson scattering system using standard commercially available components has been designed for the non-axisymmetric plasmas of the Compact Toroidal Hybrid (CTH). The beam, generated by a frequency doubled Continuum PL DLS 2 J Nd:YAG laser, is passed vertically through an entrance Brewster window and an aperturing baffle system to minimize the stray laser light that could enter the collection optics. The beam line has been designed with an 8 m propagation distance to the mid-plane of the CTH device with the beam diameter kept less than 3 mm inside the plasma volume. The beam exits the vacuum system through another Brewster window and enters a beam dump, again to minimize the stray light in the vacuum chamber. Light collection, spectral processing, and signal detection are accomplished with an f/#∼ 1 aspheric lens, a commercially available Holospec f/1.8 spectrometer, and an Andor iStar DH740-18U-C3 image intensified camera. Spectral rejection of stray laser light, if needed, can be performed with the use of an optional interference filter at the spectrometer input. The system has been developed for initial single point measurements of plasmas with core electron temperatures of approximately 20–300 eV and densities of 5 × 10{sup 18} to 5 × 10{sup 19} m{sup −3} dependent upon operational scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of the trigger system for the ICARUS detector at Fermilab

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the proton beam extraction from the accelerators. The architecture and the deployment of the trigger system in the first two runs for physics are presented, as well as the triggered event rates. The event recognition efficiency has been evaluated as a function of the deposited energy and the position of cosmic muons stopping inside the detector.

Neutrino detectors↗

SU-F-T-213: Commissioning Results of the Prototype Active Scanning Irradiation System of Korea Heavy Ion Medical Accelerator

Purpose: A prototype actives scanning beam delivery system was designed, manufactured and installed as a part of the Korea Heavy Ion Medical Accelerator Project. The prototype system includes the most components for steering, modulating, detecting incident beam to patient. The system was installed in MC-50 cyclotron beam line and tested to extract the normal operation conditions. Methods: The commissioning process was completed by using 45 MeV of proton beam. To measure the beam position accuracy along the scanning magnet power supply current, 25 different spots were scanning and measured. The scanning results on GaF film were compared with the irradiation plan. Also, the beam size variation and the intensity reduction using range shifter were measured and analyzed. The results will be used for creating a conversion factors for asymmetric behavior of scanning magnets and a dose compensation factor for longitudinal direction. Results: The results show asymmetry operations on both scanning × and y magnet. In case of scanning magnet × operation, the current to position conversion factors were measured 1.69 mm/A for positive direction and 1.74 mm/A for negative direction. The scanning magnet y operation shows 1.38mm/A and 1.48 mm/A for both directions. The size of incoming beam which was 18 mm as sigma becomes larger up to 55 mm as sigma while using 10 mm of the range shifter plate. As the beam size becomes large, the maximum intensity of the was decreased. In case of using 10 mm of range shifter, the maximum intensity was only 52% compared with no range shifter insertion. Conclusion: For the appropriate operation of the prototype active scanning system, the commissioning process were performed to measure the beam characteristics variation. The obtained results would be applied on the irradiation planning software for more precise dose delivery using the active scanning system.

43 PARTICLE ACCELERATORS↗

The Eagle ALDRIS (Agile Low-Does Radiographic Imaging System)

The overall project was to design a mobile (truck-based) cargo scanning system that can be deployed at different stations according to need. In addition, the project would optimize the use of the electron beam thereby reducing the overall radiation produced and to help make the radiation shielding lighter. The SLAC work for this project done through this CRADA was to design the beam-line from the output of the alpha-magnet at the end of the Varian linac to the photon production target. The beam is required to hit the photon production target at the same point but with a range of vertical angles from +/- 25°. In addition, the scope of work by SLAC was to provide an alternate design for the linac based on new linac and RF source technology developed at SLAC.

43 PARTICLE ACCELERATORS↗