Improved biomedical electrode

Newly designed electrode is prefilled, disposable, electrolyte-saturated spong. New design permits longe periods of storage without deterioration, and readiness in matter of seconds. Electrodes supply signals for electroencephalogram, electro-oculogram, and electrocardiogram.

Frost, J. D., Jr.↗

Improved ultrasonic biomedical measuring apparatus

Device for making measurements of organs in living specimens and recording movements of organs is described. System uses series of ultrasonic pulses beamed into body of animal and reflected echo pulses are picked up by transducers and recorded. Diagram of equipment required and method of application is included.

Lee, R. D.↗

Digital automatic data reduction techniques used in a 1000-flight biomedical study

Techniques developed to automatically process a large quantity of physiological data obtained during a 1000-flight study are described. To reduce this data reliably, a study program was conducted using physiological data from X-15 flights as a data source for experimenting with signal enhancement and noise elimination techniques. The techniques include an automatic means for counting heart rates, averaging electrocardiogram waveforms, plotting histograms of heart rate versus frequency, and counting respiration rates. These techniques were used to reduce more than 2000 hours of physiological data recorded in flight.

Carpenter, R.↗

Southwest Research Institute assistance to NASA in biomedical areas of the technology

Significant applications of aerospace technology were achieved. These applications include: a miniaturized, noninvasive system to telemeter electrocardiographic signals of heart transplant patients during their recuperative period as graded situations are introduced; and economical vital signs monitor for use in nursing homes and rehabilitation hospitals to indicate the onset of respiratory arrest; an implantable telemetry system to indicate the onset of the rejection phenomenon in animals undergoing cardiac transplants; an exceptionally accurate current proportional temperature controller for pollution studies; an automatic, atraumatic blood pressure measurement device; materials for protecting burned areas in contact with joint bender splints; a detector to signal the passage of animals by a given point during ecology studies; and special cushioning for use with below-knee amputees to protect the integrity of the skin at the stump/prosthesis interface.

Culclasure, D. F.↗

Future needs for biomedical transducers

In summary there are three major classes of transducer improvements required: improvements in existing transducers, needs for unexploited physical science phenomena in transducer design, and needs for unutilized physiological phenomena in transducer design. During the next decade, increasing emphasis will be placed on noninvasive measurement in all of these areas. Patient safety, patient comfort, and the need for efficient utilization of the time of both patient and physician requires that noninvasive methods of monitoring be developed.

Wooten, F. T.↗

Biomedical transducers.

Examples are given of some of the sensors and attachment techniques that have been developed during the last few years at the NASA centers for use in the space program. A detailed description is first given of the successive development of ECG electrodes, starting from their original simple form, that eventually resulted in the novel technology of spray-on electrodes. Finally, features of a new telemetering system under development, which is suitable for the recovery of ECG, respiration, body core temperature, and surface temperature, are outlined.

Stuart, J. L.↗

Bioastronautic aspects of Apollo biomedical operations.

Bioastronautic results of the 3105 man-hours of Apollo space flight. The absence of solar flare eliminated the radiation problem for Apollo, but for prolonged flight the problem has not been solved. Crews have adapted generally to weightlessness and used it to advantage. Body weight loss is noted, and it is only partly due to fluid loss. Sleep appears to be impaired. The preventive medicine program has been difficult to conduct but in the later flights it effectively reduced the incidence of upper respiratory and gastrointestinal infection. Motion sickness has been noted, but all astronauts adapted well. Cardiovascular deconditioning has been similar in degree and duration to that noted after the Gemini flights. The loss of red blood cell mass of Gemini was found only in Apollo 9, which was the only Apollo flight where the astronauts were exposed to pure oxygen at 5 psia for prolonged periods.

Humphreys, J. W., Jr.↗

A new dry biomedical electrode

Electronic circuitry contains new operational amplifier which incorporates monolithic super-gain transistors. Electrode does not provide voltage amplification; instead, it acts as current amplifier to make it possible to pick up electrical potentials from surface of highly resistant dry skin.

Luce, R. S.↗

Biomedical experiments. Part A: Biostack experiment

The biostack experiment is described which was designed to study the biologic effects of individual heavy nuclei of galactic cosmic radiation during space flight outside the magnetosphere of the earth. Specifically, the biostack experiment was designed to promote research on the effects of high energy/high Z particles of galactic cosmic radiation on a broad spectrum of biologic systems, from the molecular to the highly organized and developed forms of life. The experiment was considered unique and scientifically meritorious because of its potential yield of information - currently unavailable on earth - on the interaction of biologic systems with the heavy particles of galactic cosmic radiation.

Buecker, H.↗

Breeding monkeys for biomedical research

Captive bred rhesus monkeys show much less pathology than wild born animals. The monkeys may be bred in cages or in an outdoor compound. Cage bred animals are not psychologically normal which makes then unsuited for some types of space related research. Compound breeding provides contact between mother and infant and an opportunity for the infants to play with their peers which are important requirements to help maintain their behavioral integrity. Offspring harvested after a year in the compound appear behaviorally normal and show little histopathology. Compound breeding is also an economical method for the rapid production of young animals. The colony can double its size about every two and a half years.

Bourne, G. H.↗

Ultrasonic biomedical measuring and recording apparatus

A train of ultrasonic pulses is beamed into the body of an animal. Organs intercepted by the beam reflect echo pulses following each transmitted pulse. An electronic gate with a variable width and a variable time delay relative to the transmitted pulse is utilized for selecting echoes derived from other organs or portions of organs. The integral of the echo signals received within the first half of the gate period is subtracted from a corresponding integral of the echo signal received during the second half of the gate to derive an error signal for controlling the time delay of the gate. In this manner, the selected echo signal is always maintained in the center of the gate.

Lee, R. D.↗

Summer institute in biomedical engineering, 1973

Design and development work is reported for an air filter, an infant weight scale, multiple electrode cardiography, a white noise hearing aid, and a tibial torsion correction device.

Deloatch, E. M.↗

Summer Institute in Biomedical Engineering, 1973

Bioengineering of medical equipment is detailed. Equipment described includes: an environmental control system for a surgical suite; surface potential mapping for an electrode system; the use of speech-modulated-white-noise to differentiate hearers and feelers among the profoundly deaf; the design of an automatic weight scale for an isolette; and an internal tibial torsion correction study. Graphs and charts are included with design specifications of this equipment.

Deloatch, E. M.↗