At least 469 records · Page 26

Innovations in Sensors and Controls for Building Energy Management: Research and Development Opportunities Report for Emerging Technologies

Sensors, actuators, and controllers, which collectively serve as the backbone of cyberphysical systems for building energy management, are one of the core technical areas of investment for achieving the U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) goals for energy affordability in the national building stock - both commercial and residential. In fact, an aggregated annual energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms. energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy savings modelling of re-tuning energy conservation measures in large office buildings

Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS’s capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This paper investigates the energy savings potential of several common HVAC system re-tuning measures on a typical large office building, using the Department of Energy’s building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply-air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated – each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All the individual measures and combinations were simulated in 16 climate locations representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual total HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy savings for most cities for all measures). Combining many of the re-tuning measures revealed deep savings potential. Some of the more aggressive combinations revealed 35-75% reductions in annual HVAC energy consumption, depending on climate and building vintage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Modeling of Standard Commercial Building Re-tuning Measures: Large Office Buildings

Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS's capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This report investigates the energy savings potential of several common HVAC system retuning measures on a typical large office building prototype model, using the Department of Energy's building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated - each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All of these measures and combinations were simulated in 16 cities representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy savings for most cities for all measures). Combining many of the retuning measures revealed deep savings potential. Some of the more aggressive combinations revealed 35-75% reductions in annual HVAC energy consumption, depending on climate and building vintage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Energy, Demand, Emissions, and Cost Savings Distributions for Buildings in a Utility’s Service Area

Several companies, universities, and national laboratories are developing urban-scale energy modeling that allows the creation of a digital twin of buildings for the simulation and optimization of real-world, city-sized areas. Prior to simulation-based assessment, a baseline of savings for a set of utility-defined use cases was established to clarify the initial business case for specific energy efficient building technologies. In partnership with a municipal utility, 178,337 OpenStudio and EnergyPlus models of buildings in the utility’s 1400 km 2 service area were created, simulated, and assessed with measures for quantifying energy, demand, cost, and emissions reductions of each building. The method of construction and assumptions behind these models is discussed, definitions of example measures are provided, and distribution of savings across the building stock is provided under a maximum technical adoption scenario.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

City Scale Modeling with OpenStudio

Assessing the impact of energy efficiency technologies at a district or city scale is of great interest to local governments, real estate developers, utility companies, and policymakers. This paper describes a flexible framework that can be used to create and run district and city scale building energy simulations. The framework is built around the new OpenStudio City Database (CityDB). Building footprints, building height, building type, and other data can be imported from public records or other sources. Missing data can be inferred or assigned from a statistical sampling of other datasets. Once all required data is available, OpenStudio Measures are used to create starting point energy models and to model energy efficiency measures for each building. Together this framework allows a user to pose several scenarios such as 'what if 30% of the commercial retail buildings added rooftop solar' or 'what if all elementary schools converted to ground source heat pumps' and then visualize the impacts at a district or city scale. This paper focuses on modeling existing building stock using public records. However, the framework is capable of supporting the evaluation of new construction, district systems, and the use of proprietary data sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Putting Data to Work: Using Building Energy Performance Data to Expand the Market for Energy Efficiency in Buildings

An increasing number of state and local jurisdictions are implementing building performance reporting laws, which generate large quantities of useful data on the characteristics and resource consumption of the building stock. Yet, to realize the potential of these policies, the data must not only be disclosed, but put to work to drive energy savings. Under a three-year pilot, Washington DC (DC), New York City (NYC) and their partners are pioneering the use of data from building performance reporting in energy efficiency programs. To minimize the administrative burden of managing, combining, and sharing these data sets, the cities are utilizing the U.S. Department of Energy’s (DOE) open-source Standard Energy Efficiency Data (SEED) Platform. The Putting Data to Work project team is working with efficiency program administrators to develop and implement new and innovative ways in which the data collected through benchmarking, energy audits, and related policies can be used to improve energy policies and planning, unlock data directly for market use, scale-up the market for energy efficiency services, drive competition, better target utility incentive programs, and inform measurement and verification. This paper details achievements and key findings in DC and NYC to date, including the importance of high compliance, data quality, and data cleansing in using the information collected; methods that the cities are using to apply data to drive maximum energy efficiency; and the importance of inter- and intra-agency collaboration in program success. We also outline the path forward and detail expected outcomes and scalability of project activities.

Beddingfield, Erin↗

Deep Retrofits for Multifamily: Experiences in Scaling to Zero Energy: Preprint

Zero net energy (ZNE) buildings are needed to reverse the growing trend of increasing energy consumption. But to make dramatic changes, existing buildings must be renovated at scale. In addition, the building stock must be electrified so that its energy needs could be met by renewable generation. Such aggressive goals often mean very high custom design and capital construction costs. Suitable options for comprehensive envelope retrofits can be too expensive to be practical, and electrification requires upgrades to building-level electrical infrastructure. This paper is a case study of eight projects—primarily multifamily residential—that strived for zero-energy, all-electric retrofits. The design teams were challenged to create solutions that could be replicated at scale, showing decreasing costs with broader adoption. Key technologies considered in designing cost-effective, scalable solutions include industrialized prefabricated retrofit components, modular HVAC solutions, and innovative domestic hot water systems. We trace the progress toward the goals set and examine the choices made by the teams as they encountered technical, logistical, and cost barriers. We also discuss financial challenges for multifamily retrofits, provide guidance for incentives, and examine procurement processes for design services and technologies.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Informing electrification strategies of residential neighborhoods with urban building energy modeling

Electrifying end uses is a key strategy to reducing GHG emissions in buildings. However, it may increase peak electricity demand that triggers the need to upgrade the existing power distribution system, leading to delays in electrification and needs of significant investment. There is also concern that building electrification may cause an increase of energy costs, leading to further energy burden for low-income communities. This study uses the urban scale building modeling tool CityBES to assess the electrification impacts of more than 43,000 residential buildings in a neighborhood of Portland, Oregon, USA. Energy efficiency upgrades were investigated on their potential to mitigate the increase of peak electricity demand and energy burden. Simulation results from the calibrated EnergyPlus models show that electrification with heat pumps for space heating and cooling as well as for domestic water heating can reduce CO2e emissions by 38%, but increase peak electricity demand by about 9% from the baseline building stock. Combining electrification measures and energy efficiency upgrades can reduce CO2e emissions by 48% while reducing peak electricity demand by 6% and saving the median household energy costs by 28%. City and utility decision makers should consider integrating energy efficiency upgrades with electrification measures as an effective residential building electrification strategy, which significantly reduces carbon emissions, caps or even decreases peak demand while reducing energy burden of residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hawaii Clean Energy Initiative Existing Building Energy Efficiency Analysis: November 17, 2009 - June 30, 2010

In June 2009, the State of Hawaii enacted an Energy Efficiency Portfolio Standard (EEPS) with a target of 4,300 gigawatt hours (GWh) by 2030 (Hawaii 2009). Upon setting this goal, the Hawaii Clean Energy Initiative, Booz Allen Hamilton (BAH), and the National Renewable Energy Laboratory (NREL), working with select local stakeholders, partnered to execute the first key step toward attaining the EEPS goal: the creation of a high-resolution roadmap outlining key areas of potential electricity savings. This roadmap was divided into two core elements: savings from new construction and savings from existing buildings. BAH focused primarily on the existing building analysis, while NREL focused on new construction forecasting. This report presents the results of the Booz Allen Hamilton study on the existing building stock of Hawaii, along with conclusions on the key drivers of potential energy efficiency savings and on the steps necessary to attain them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Municipal Portfolio Performance and Policy Opportunities

A wide range of policy tools are in place to enhance energy efficiency in the built environment. However, the lion’s share of today’s energy savings opportunities have to do with energy consumption in existing buildings currently in operation. Many of the policy tools in play, including energy codes, have little to no effect on these existing buildings. New tools and resources are needed to bring existing buildings up to higher levels of energy performance. This project was focused on building a replicable framework, complete with open-source software tools and resources, to empower cities around the country to significantly enhance the energy performance of their own existing buildings and identify opportunities for future improvements. These issues were addressed through the evaluation of the performance of the municipal building stock and policy environments of four mid-size cities: Eugene, Oregon; Providence, Rhode Island; Grand Rapids, Michigan; and Tacoma, Washington. The project team worked closely with these cities to help city staff lead by example and create actionable, implementation-focused strategic energy plans for their own municipal building portfolios and to evaluate and improve city policies. A major focus throughout has been replicability and knowledge transfer (“teaching them to fish” rather than doing the work for the city).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy savings potential from improved building controls for the US commercial building sector

The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sector energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29%; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.

Fernandez, Nick↗

Modeling Distributed Generation in California

In support of analysis for the biennial Integrated Energy Policy Report, the California Energy Commission and the National Renewable Energy Laboratory have partnered to study the growth of distributed energy resources in California. This study involves the use of National Renewable Energy Laboratory's Distributed Generation Market Demand model, available at https://www.nrel.gov/analysis/dgen/, to project statewide adoption of distributed photovoltaics and paired storage. Key outcomes of the collaboration include: • Improved representation of California building stock, load profiles, historical adoption, and tariffs, including the net billing tariff, in the dGen model; • Trained CEC staff members to use and adapt the dGen model for their specific needs; • Developed a methodology for representing emerging consumer segments to potentially adopt distributed energy resources, including low-income, multifamily, and renter-occupied buildings; • Forecasted solar photovoltaic and paired storage growth in California using a common set of modeling parameters. This report describes the multiyear effort, which includes a discussion of: • Methodology and data employed in adapting the Distributed Generation Market Demand model for California to forecast solar photovoltaic and storage statewide through 2040; • Steps taken to modify the base model to forecast solar photovoltaic adoption in emerging market segments such as multifamily or renter-occupied homes or both; • Future enhancements of the model.

14 SOLAR ENERGY↗

The Impact of DOE Building Technology Energy Efficiency Programs on U.S. Employment, Income, and Investment

To more fully evaluate its programs to increase the energy efficiency of the U.S. residential and commercial building stock, the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) assesses the macroeconomic impacts of those programs, specifically on national employment, wage income, and (most recently) investment. The analysis is conducted using the Impact of Sector Energy Technologies (ImSET) model, a special-purpose 188-sector input-output model of the U.S. economy designed specifically to evaluate the impacts of energy efficiency investments and saving. For the analysis described in the paper, ImSET was amended to provide estimates of sector-by-sector capital requirements and investment. In the scenario of the Fiscal Year (FY) 2005 Buildings Technology (BT) program, the technologies and building practices being developed and promoted by the BT program have the prospect of saving about 2.9×1015 Btu in buildings by the year 2030, about 27% of the expected growth in buildings energy consumption by the year 2030. The analysis reported in the paper finds that, by the year 2030, these savings have the potential to increase employment by up to 446,000 jobs, increase wage income by $7.8 billion, reduce needs for capital stock in the energy sector and closely related supporting industries by about $207 billion (and the corresponding annual level of investment by $13 billion), and create net capital savings that are available to grow the nation’s future economy.

economic impact↗

Cost-Effectiveness of Home Energy Retrofits in Pre-Code Vintage Homes in the United States

This analytical study examines the opportunities for cost-effective energy efficiency and renewable energy retrofits in residential archetypes constructed prior to 1980 (Pre-Code) in fourteen U.S. cities. These fourteen cities are representative of each of the International Energy Conservation Code (IECC) climate zones in the contiguous U.S. The analysis is conducted using an in-house version of EnergyGauge USA v.2.8.05 named CostOpt that has been programmed to perform iterative, incremental economic optimization on a large list of residential energy efficiency and renewable energy retrofit measures. The principle objectives of the study are as follows: to determine the opportunities for cost effective source energy reductions in this large cohort of existing residential building stock as a function of local climate and energy costs; and to examine how retrofit financing alternatives impact the source energy reductions that are cost effectively achievable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗