At least 469 records · Page 26

The mechanical design of a vapor compressor for a heat pump to be used in space

A heat pump developed for use in Spacelab as a stand-alone refrigeration unit as well as within a fluid loop system is discussed. It will provide an active thermal control for payloads. Specifications for the heat pump were established: (1) heat removal rates at the source; (2) heat source temperatures from room temperature; (3) heat-sink fluid temperatures at condenser inlet; and (4) minimum power consumption. A reversed Carnot cycle heat pump using Freon 12 as working fluid incorporating a one-cylinder reciprocating compressor was selected. The maximum crankshaft speed was fixed relatively high at 100 rpm. The specified cooling rates then made it necessary to select a cylinder volume of 10 cu cm, which was obtained with a bore of 40 mm and a stroke of 8 mm.

Berner, F.↗

Three dimensional flow field inside the passage of a low speed axial flow compressor rotor

Measurements of the subsonic flow in the rotor passage of a single stage axial flow compressor were made to study the nature of the flow field and to verify the existing numerical codes. The velocity and pressure fields were measured across the entire rotor passage at six axial locations and at five radial locations. A five-hole probe, rotating with the rotor, was used to measure the three components of velocity, the static and the total pressure. The experimental results are compared with the predictions from Katsanis and McNally's computer program. The agreement between the two is good for most of the cases.

Pouagare, M.↗

Vibration and destabilizing effects of floating ring seals in compressors

Operating experience on a compressor commissioned 12 years ago has presented an interesting history of sporadic increases in shaft vibration. Initial operation was satisfactory with low levels of vibration. However, after some time the shaft vibration level increased to several mils. Initially this was believed to be due to rotor unbalance from deposits formed in the passages due to process upsets. After cleaning up the rotor, operation was again increased. It was then found that the rotor vibration was primarily subsynchronous. Further investigation revealed that the original seal design was subject to wear and was no longer properly pressure balanced. A modified seal design was installed and it has operated successfully for the past six years.

Emerick, M. F.↗

Unsteady flow phenomena in industrial centrifugal compressor stage

The results of an experimental investigation on a typical centrifugal compressor stage running on an atmospheric pressure test rig are shown. Unsteady flow was invariably observed at low flow well before surge. In order to determine the influence of the statoric components, the same impeller was repeatedly tested with the same vaneless diffuser, but varying return channel geometry. Experimental results show the strong effect exerted by the return channel, both on onset and on the behavior of unsteady flow. Observed phenomena have been found to confirm well the observed dynamic behavior of full load tested machines when gas density is high enough to cause appreciable mechanical vibrations. Therefore, testing of single stages at atmospheric pressure may provide a fairly accurate prediction of this kind of aerodynamic excitation.

Bonciani, L.↗

Comparative study of subsynchronous rotating flow patterns in centrifugal compressors with vaneless diffusers

A comparative experimental investigation of the unstable operating modes of a centrifugal compressor was made. Impeller and/or diffuser rotating stall was observed, depending on the flow conditions. The measured relative rotational speed of this perturbation is cross checked with other experimental data and it is shown that the rotational speed is strongly dependent on the type of rotating stall. The diffuser absolute inlet flow angle at the onset of diffuser rotating stall agrees well with the value predicted by an existing stability criterion.

Frigne, P.↗

Comparison of two- and three-dimensional flow computations with laser anemometer measurements in a transonic compressor rotor

Two and three dimensional inviscid solutions for the flow in a transonic axial compressor rotor at design speed are compared with probe and laser anemometers measurements at near-stall and maximum-flow operating points. Experimental details of the laser anemometer system and computational details of the two dimensional axisymmetric code and three dimensional Euler code are described. Comparisons are made between relative Mach number and flow angle contours, shock location, and shock strength. A procedure for using an efficient axisymmetric code to generate downstream pressure input for computationally expensive Euler codes is discussed. A film supplement shows the calculations of the two operating points with the time-marching Euler code.

Chima, R. V.↗

A method of predicting the performance deterioration of a compressor cascade due to sand erosion

Performance deterioration due to sand erosion is a well known phenomena for aircraft engines operating in particulate flow environments. A method for predicting this performance deterioration is developed and applied to a two dimensional compressor cascade. The locations of the particles impacts are computed by analyzing the trajectories of the individual particles. From this analysis, the material removed, the changes in the airfoil shape, and the roughness development over the surface are estimated as a function of time. The resulting airfoil profiles are analyzed for predicting performance by using an inviscid-viscous interaction technique. The analytical solution is compared with experimental results.

Balan, C.↗

Miniature J-T refrigators using adsorption compressors

More sophisticated cooling systems for the employed detectors will be needed to satisfy the demand for higher resolution and sensitivity of various detectors used in space missions. The design of the cooling system must take into consideration the unique environment of space vehicles. It is pointed out that a deep space vehicle usually has an ample supply of waste heat from a radioisotope thermoelectric generator (RTG) and has a heat sink near zero Kelvin. Passive radiative coolers have been used for cooling temperatures above 90 K. Cooling below 90 K is currently handled by phase changes of solid or liquid cryogens or mechanical refrigeration. However, the weight of the cryogen may be a problem in a long duration space mission. Refrigerators of small cooling capacity are required in many spacecraft applications. For some future NASA missions, a multistage Joule-Thomson refrigerator using adsorption compressors appears particularly attractive. A study is discussed of four different refrigeration stages which use charcoal as the adsorbent. The adsorbed gases are nitrogen, helium, hydrogen, and neon.

Chan, C. K.↗

Design of shock-free compressor cascades including viscous boundary layer effects

A computer code that generates shock-free transonic compressor cascade shapes while taking into account viscosity effects is developed. The mathematical model for the inviscid flow field is the full potential equation. The Kutta-Joukowski condition is satisfied by varying the free stream angle at downstream infinity. A boundary fitted computational grid of C-type is generated using a sequence of conformal mapping and nonorthogonal coordinate stretching and shearing transformations. The inviscid calculation is performed sequentially on up to four consecutively refined grids thereby accelerating the convergence of the solution process. The full potential equation is solved using a finite area technique and rotated, type-dependent finite differencing. Artificial viscosity of the first order is added in a fully conservative form. Shock-free cascade airfoil shapes are obtained using the fictitious gas concept of Sobieczky and the method of characteristics in the rheograph plane. Viscosity effects are incorporated via a boundary layer displacement thickness. The integral boundary layer code is based on Rotta's turbulence model and assumes transition region of zero length.

Dulikravich, G. S.↗

Cold-air performance of compressor-drive turbine of department of energy upgraded automobile gas turbine engine. 3: Performance of redesigned turbine

The aerodynamic performance of a redesigned compressor drive turbine of the gas turbine engine is determined in air at nominal inlet conditions of 325 K and 0.8 bar absolute. The turbine is designed with a lower flow factor, higher rotor reaction and a redesigned inlet volute compared to the first turbine. Comparisons between this turbine and the originally designed turbine show about 2.3 percentage points improvement in efficiency at the same rotor tip clearance. Two versions of the same rotor are tested: (1) an as cast rotor, and (2) the same rotor with reduced surface roughness. The effect of reducing surface roughness is about one half percentage point improvement in efficiency. Tests made to determine the effect of Reynolds number on the turbine performance show no effect for the range from 100,000 to 500,000.

Roelke, R. J.↗

Centrifugal-reciprocating compressor

A centrifugal compressor is described which includes at least one pair of cylinders arranged in coaxial alignment and supported for angular displacement about a common axis of rotation normally disecting a common longitudinal axis of symmetry for the cylinders. The cylinders are characterized by ported closures located at the mutually remote ends thereof through which the cylinders are charged and discharged, and a pair of piston heads seated within the cylinders and supported for floating displacement in compressive strokes in response to unidirectional angular displacement imparted to the cylinders.

Higa, W. H.↗

Structural Analysis of the Support System for a Large Compressor Driven by a Synchronous Electric Motor

For economic reasons, the steam drive for a large compressor was replaced by a large synchronous electric motor. Due to the resulting large increase in mass and because the unit was mounted on a steel frame approximately 18 feet above ground level, it was deemed necessary to determine if a steady state or transient vibration problem existed. There was a definite possibility that a resonant or near resonant condition could be encountered. The ensuing analysis, which led to some structural changes as the analysis proceeded, did not reveal any major steady state vibration problems. However, the analysis did indicate that the system would go through several natural frequencies of the support structure during start-up and shutdown. This led to the development of special start-up and shutdown procedures to minimize the possibility of exciting any of the major structural modes. A coast-down could result in significant support structure and/or equipment damage, especially under certain circumstances. In any event, dynamic field tests verified the major analytical results. The unit has now been operating for over three years without any major vibration problems.

Winter, J. R.↗

Energy efficient engine. High pressure compressor detail design report

A compressor optimization study defined a 10-stage configuration with a 22.6:1 pressure ratio, and adiabatic efficiency goal of 86.1%, and a polytropic efficiency of 90.6%; the corrected airflow is 53.5 kg/sec. Subsequent component testing included three full-scale tests: a six-stage rig test, and another 10-stage rig test completed in the second quarter of 1982. Information from these tests is being used to select the configuration for a core engine test scheduled for July 1982 and an integrated core/low spool test slated for early 1983. The test results will also provide data base for the flight propulsion system.

Holloway, P. R.↗

Magentically actuated compressor

A vibration free fluid compressor particularly adapted for Stirling cycle cryogenic refrigeration apparatus comprises a pair of identical opposing ferromagnetic pistons located in a housing and between a gas spring including a sealed volume of a working fluid such as gas under pressure. The gas compresses and expands in accordance with movement of the pistons to generate a compression wave which can be vented to other apparatus, for example, a displacer unit in a Stirling cycle engine. The pistons are urged outwardly due to the pressure of the gas; however, a fixed electromagnetic coil assembly located in the housing adjacent the pistons, is periodically energized to produce a magnetic field which interlinks the pistons in such a fashion that the pistons are mutually attracted to one another. The mass of the pistons, in conjunction with the compressed gas between them, form a naturally resonant system which, when the pistons are electromagnetically energized, produces an oscillating compression wave in the entrapped fluid medium.

Evans, J.↗

Airflow calibration of a bellmouth inlet for measurement of compressor airflow in turbine-powered propulsion simulators

The development of turbine-powered propulsion simulators for high-speed wind tunnel models requires a bellmouth inlet which can accurately measure compressor-inlet airflow. A bellmouth inlet was instrumented with total pressure probes, static pressure probes, and thermocouples for airflow measurement. The bellmouth flowmeter against a critical venturi flowmeter was calibrated. The calibration was done at four inlet pressures ranging from 58 to 114 kPa. The bellmouth discharge coefficient varied as a function of bellmouth-throat Mach number. Over the range of Reynolds number and Mach number tested the Reynolds number was not a significant influence on the discharge coefficient. The overall accuracy of the bellmouth inlet as a flowmeter was estimated to be + or - 0.5% of the flowmeter reading.

Smith, S. C.↗

Extended parametric representation of compressor fans and turbines. Volume 2: Part user's manual (parametric turbine)

A turbine modeling technique has been developed which will enable the user to obtain consistent and rapid off-design performance from design point input. This technique is applicable to both axial and radial flow turbine with flow sizes ranging from about one pound per second to several hundred pounds per second. The axial flow turbines may or may not include variable geometry in the first stage nozzle. A user-specified option will also permit the calculation of design point cooling flow levels and corresponding changes in efficiency for the axial flow turbines. The modeling technique has been incorporated into a time-sharing program in order to facilitate its use. Because this report contains a description of the input output data, values of typical inputs, and example cases, it is suitable as a user's manual. This report is the second of a three volume set. The titles of the three volumes are as follows: (1) Volume 1 CMGEN USER's Manual (Parametric Compressor Generator); (2) Volume 2 PART USER's Manual (Parametric Turbine); (3) Volume 3 MODFAN USER's Manual (Parametric Modulation Flow Fan).

Coverse, G. L.↗

CO2 compressor vibration and cause analysis

The operational experience of a large turbine drive carbon dioxide compressor train in a urea plant with capacity of 1620 tons/day is considered. After the initial start-up in 1976, the vibration in the HP cylinder was comparatively serious. The radial vibration reached 4.2 to 4.5 mils and fluctuated around this value. It was attributed to the rotating stall based on the spectrum analysis. Additional return line from the 4th to 4th and higher temperature of the 4th inlet has cured the vibration. Problems are described which were encountered in the operation along with their solutions, and/or improvements.

Ying, Y. L.↗

Active suppression of compressor instabilities

A strategy is proposed for controlling aerodynamic instabilities which limit the useful range of both axial and centrifugal turbomachines. Both local and global instabilities (incipient rotating stall and surge) are analyzed. A theory is developed which shows how an additional disturbance, driven from real time data measured within the machine, can be generated so as to realize a device with characteristics fundamentally different from those of the turbomachine without control; for the particular compressor analyzed, the control led to a 20 percent increase in the extent of the stable operating range. The use of structural dynamics to enhance stability is also discussed.

Epstein, A. H.↗