Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUPLINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Search for anomalous couplings in the W tb vertex from the measurement of double differential angular decay rates of single top quarks produced in the t-channel with the ATLAS detector

The electroweak production and subsequent decay of single top quarks is determined by the properties of the Wtb vertex. This vertex can be described by the complex parameters of an effective Lagrangian. An analysis of angular distributions of the decay products of single top quarks produced in the t -channel constrains these parameters simultaneously. The analysis described in this paper uses 4.6 fb -1 of proton-proton collision data at √s=7 TeV collected with the ATLAS detector at the LHC. Two parameters are measured simultaneously in this analysis. The fraction f 1 of decays containing transversely polarised W bosons is measured to be 0.37 ± 0.07 (stat.⊕syst.). The phase δ - between amplitudes for transversely and longitudinally polarised W bosons recoiling against left-handed b-quarks is measured to be -0.014π ± 0.036π (stat.⊕syst.). The correlation in the measurement of these parameters is 0.15. These values result in two-dimensional limits at the 95% confidence level on the ratio of the complex coupling parameters g R and V L , yielding Re[g R /V L ] ϵ [-0.36, 0.10] and Im[g R /V L ] ϵ [-0.17, 0.23] with a correlation of 0.11. We find the results are in good agreement with the predictions of the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photocatalytic degradation of organic pollutants coupled with simultaneous photocatalytic H 2 evolution over graphene quantum dots/Mn-N-TiO 2 /g-C 3 N 4 composite catalysts: Performance and mechanism

Graphene quantum dots/Mn-N-TiO 2 /g-C 3 N 4 (GQDs/TCN) composite photocatalysts have been designed, synthesized and characterized by XRD, SEM, TEM, Raman, BET, and XPS. The photodegradation of organic pollutants (p-nitrophenol, diethyl phthalate and ciprofloxacin, called as 4-NP, CIP and DEP, respectively) coupled with simultaneous photocatalytic production of hydrogen was successfully achieved using the GQDs/TCN catalysts. The 5%GQDs/TCN-0.4 sample shows the best photocatalytic hydrogen production and organic pollutant degradation rate under simulated solar irradiation in the simultaneous photocatalytic oxidation and reduction system. Furthermore, the photocatalytic H 2 evolution rates in the solution of 4-NP, CIP and DEP are all larger than that in pure water system over the 5%GQDs/TCN-0.4 catalyst. And the H 2 evolution rate in the solution of 4-NP is smaller than that in the solutions of CIP and DEP. Accordingly, the photodegradation rate of 4-NP is larger than that of CIP and DEP. The analyses of density functional theory and liquid chromatography mass spectrometry indicate that some photogenerated electrons were used in the photodegradation process of 4-NP but not in that of CIP and DEP. And it leads to the photocatalytic rate of H 2 evolution in the 4-NP solution smaller than that in the solution of CIP and DEP. For the first time, the present work illuminates the photocatalytic enhancement of the GQDs/TCN-0.4 catalyst and the mechanism of the effect of different organic pollutants on photocatalytic H 2 evolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GFCCLib: Scalable and efficient coupled-cluster Green's function library for accurately tackling many-body electronic structure problems

Coupled-cluster Green’s function (GFCC) calculation has drawn much attention in the recent years for targeting the molecular and material electronic structure problems from a many-body perspective in a systematically improvable way. However, GFCC calculations on scientific computing clusters usually suffer from expensive higher di- mensional tensor contractions in the complex space, expensive inter-process communi- cation, and severe load imbalance, which limits it’s routine use for tackling electronic structure problems. Here we present a numerical library prototype that is specifically designed for large-scale GFCC calculations. The design of the library is focused on a systematically optimal computing strategy to improve its scalability and efficiency. The performance of the library is demonstrated by the relevant profiling analysis of running GFCC calculations on remote giant computing clusters. The capability of the library is highlighted by computing a wide near valence band of a fullerene C60 molecule for the first time at the GFCCSD level that shows excellent agreement with the experimental spectrum.

Peng, Bo↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

Molecular Mechanism for Inhibition of G Protein-Coupled Receptor Kinase 2 by a Selective RNA Aptamer

Cardiovascular homeostasis is maintained in part by the rapid desensitization of activated heptahelical receptors that have been phosphorylated by G protein-coupled receptor kinase 2 (GRK2). However, during chronic heart failure GRK2 is upregulated and believed to contribute to disease progression. We have determined crystallographic structures of GRK2 bound to an RNA aptamer that potently and selectively inhibits kinase activity. Key to the mechanism of inhibition is the positioning of an adenine nucleotide into the ATP-binding pocket and interactions with the basic {alpha}F-{alpha}G loop region of the GRK2 kinase domain. Constraints imposed on the RNA by the terminal stem of the aptamer also play a role. These results highlight how a high-affinity aptamer can be used to selectively trap a novel conformational state of a protein kinase.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of a 512-Channel Faraday-Strip Array Detector Coupled to an Inductively Coupled Plasma Mattauch-Herzog Mass Spectrograph

A 512-channel Faraday-strip array detector has been developed and fitted to a Mattauch-Herzog geometry mass spectrograph for the simultaneous acquisition of multiple mass-to-charge values. Several advantages are realized by using simultaneous detection methods, including higher duty cycles, removal of correlated noise, and multianalyte transient analyses independent of spectral skew. The new 512-channel version offers narrower, more closely spaced pixels, providing improved spectral peak sampling and resolution. In addition, the electronics in the amplification stage of the new detector array incorporate a sample-and-hold feature that enables truly simultaneous interrogation of all 512 channels. While sensitivity and linear dynamic range remain impressive for this Faraday-based detector system, limits of detection and isotope ratio data have suffered slightly from leaky p-n junctions produced during the manufacture of the semiconductor-based amplification and readout stages. This paper describes the new 512-channel detector array, the current dominant noise sources, and the figures of merit for the device as pertaining to inductively coupled plasma ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Concerted One-Electron Two-Proton Transfer Processes in Models Inspired by the Tyr-His Couple of Photosystem II

Nature employs a TyrZ-His pair as a redox relay that couples proton transfer to the redox process between P680 and the water oxidizing catalyst in photosystem II. Artificial redox relays composed of different benzimidazole- phenol dyads (benzimidazole models His and phenol models Tyr) with substituents designed to simulate the hydrogen bond network surrounding the TyrZ-His pair have been prepared. When the benzimidazole substituents are strong proton acceptors such as primary or tertiary amines, theory predicts that a concerted two proton transfer process associated with the electrochemical oxidation of the phenol will take place. Also, theory predicts a decrease in the redox potential of the phenol by ~300 mV and a small kinetic isotope effect (KIE). Indeed, electrochemical, spectroelectrochemical, and KIE experimental data are consistent with these predictions. Notably, these results were obtained by using theory to guide the rational design of artificial systems and have implications for managing proton activity to optimize efficiency at energy conversion sites involving water oxidation and reduction.

Huynh, Mioy T.↗