Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Bump Morphology of the CMAGIC Diagram

Abstract We apply the color–magnitude intercept calibration method (CMAGIC) to the Nearby Supernova Factory SNe Ia spectrophotometric data set. The currently existing CMAGIC parameters are the slope and intercept of a straight line fit to the linear region in the color–magnitude diagram, which occurs over a span of approximately 30 days after maximum brightness. We define a new parameter, ω XY , the size of the “bump” feature near maximum brightness for arbitrary filters X and Y . We find a significant correlation between the slope of the linear region, β XY , in the CMAGIC diagram and ω XY . These results may be used to our advantage, as they are less affected by extinction than parameters defined as a function of time. Additionally, ω XY is computed independently of templates. We find that current empirical templates are successful at reproducing the features described in this work, particularly SALT3, which correctly exhibits the negative correlation between slope and “bump” size seen in our data. In 1D simulations, we show that the correlation between the size of the “bump” feature and β XY can be understood as a result of chemical mixing due to large-scale Rayleigh–Taylor instabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Anthropogenic sulfur dioxide emissions: 1850-2005

Sulfur aerosols impact human health, ecosystems, agriculture, and global and regional climate. A new annual estimate of anthropogenic global and regional sulfur dioxide emissions has been constructed spanning the period 1850 2005 using a bottom-up mass balance method, calibrated to country-level inventory data. Global emissions peaked in the early 1970s and decreased until 2000, with an increase in recent years due to increased emissions in China, international shipping, and developing countries in general. An uncertainty analysis was conducted including both random and systemic uncertainties. The overall global uncertainty in sulfur dioxide emissions is relatively small, but regional uncertainties ranged up to 30%. The largest contributors to uncertainty at present are emissions from China and international shipping. Emissions were distributed on a 0.5 grid by sector for use in coordinated climate model experiments.

54 ENVIRONMENTAL SCIENCES↗

Ground-based All-sky Mid-infrared and Visible Imagery for Purposes of Characterizing Cloud Properties

This paper describes the All Sky Infrared Visible Analyzer (ASIVA), a multi-purpose visible and infrared sky imaging and analysis instrument whose primary functionality is to provide radiometrically calibrated imagery in the mid-infrared (mid-IR) atmospheric window. This functionality enables the determination of diurnal hemispherical cloud fraction (HCF) and estimates of sky/cloud temperature from which one can derive estimates of cloud emissivity and cloud height. This paper describes the calibration methods and performance of the ASIVA instrument with particular emphasis on data products being developed for the meteorological community. Data presented here were collected during a field campaign conducted at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Climate Research Facility from May 21 to July 27, 2009. The purpose of this campaign was to determine the efficacy of IR technology in providing reliable nighttime HCF data. Significant progress has been made in the analysis of the campaign data over the past several years and the ASIVA has proven to be an excellent instrument for determining HCF as well as several other important cloud properties.

analyzer↗

Wet Chemical Compositional and Near IR Spectra Data Sets for Biomass

Near-infrared (NIR) calibration models are created by applying multivariate calibration methods to the combination of wet chemistry data and NIR spectra of a given set of biomass samples. Wet chemical compositional data and NIR spectra exist for the following types of biomass samples: corn stover, switchgrass, mixed hardwoods, mixed softwoods, sorghum, and miscanthus. These samples may be feedstock samples, washed and dried solids from one or more pretreatment processes, liquors derived from one or more pretreatment processes, or whole pretreated slurries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precipitation Estimate Using NEXRAD Ground-Based Radar Images: Validation, Calibration and Spatial Analysis

Precipitation is an important input variable for hydrologic and ecological modeling and analysis. Next Generation Radar (NEXRAD) can provide precipitation products that cover most of the continental United States with a high resolution display of approximately 4 × 4 km2. Two major issues concerning the applications of NEXRAD data are (1) lack of a NEXRAD geo-processing and geo-referencing program and (2) bias correction of NEXRAD estimates. In this chapter, a geographic information system (GIS) based software that can automatically support processing of NEXRAD data for hydrologic and ecological models is presented. Some geostatistical approaches to calibrating NEXRAD data using rain gauge data are introduced, and two case studies on evaluating accuracy of NEXRAD Multisensor Precipitation Estimator (MPE) and calibrating MPE with rain-gauge data are presented. The first case study examines the performance of MPE in mountainous region versus south plains and cold season versus warm season, as well as the effect of sub-grid variability and temporal scale on NEXRAD performance. From the results of the first case study, performance of MPE was found to be influenced by complex terrain, frozen precipitation, sub-grid variability, and temporal scale. Overall, the assessment of MPE indicates the importance of removing bias of the MPE precipitation product before its application, especially in the complex mountainous region. The second case study examines the performance of three MPE calibration methods using rain gauge observations in the Little River Experimental Watershed in Georgia. The comparison results show that no one method can perform better than the others in terms of all evaluation coefficients and for all time steps. For practical estimation of precipitation distribution, implementation of multiple methods to predict spatial precipitation is suggested.

Zhang, Xuesong↗

Complex Sources and Impacts on Remediation and Monitoring Approaches

Remedy selection, implementation, and coordination with tank farm activities for adjacent waste sites need to be facilitated by a technically defensible description of sources and their relative strength and temporal contributions to groundwater contamination. Detailed data describing contaminant source releases are typically not available, so source locations are highly uncertain. Furthermore, data on sources and model parameters are not readily available through direct measurements. Instead, source data are often derived by extrapolation from a few direct and/or indirect measurements, while model parameters are commonly estimated using inverse modeling or calibration methods. Because the conceptual model of sources will influence the mass and timing of the flux of contaminants to groundwater, uncertainty in the source terms should be considered. Even though a best-fit model can often be identified, it may not be the best representation of the sources given the sparse, uncertain nature of the data used for estimating source terms. To support future feasibility studies, a systematic approach is needed for identifying remediation and monitoring activities appropriate under conditions of uncertainty. In this study, an integrated assessment of alternative conceptual model elements has been examined using the B-Complex site in the Hanford Central Plateau to demonstrate how multiple sources in a waste management complex can be described to identify their relative contributions to groundwater. The heterogeneous structure of the system is modeled based on available field information on the lithological data for both the vadose zone and aquifer. The approach includes a simulation assessment and linkages to site data, with an uncertainty analysis applied to evaluate the effects of source term uncertainty on contaminant mass flux to groundwater. An integrated assessment of alternative conceptual model elements was evaluated to identify how parameter uncertainty impacts both temporal and spatial uncertainties associated with vadose zone source terms. Modeling scenarios identify important characteristics of remediation target zones to provide context for how surface barriers, in situ remedies, and water-table treatment zones can be designed to account for source dynamics. Ramifications for remediation and monitoring are discussed within the context of the source term uncertainty. The described approach facilitates systematically addressing alternative conceptual model questions in relation to remediation and monitoring and supports the remedial investigation/ feasibility study process and the remediation strategy development for the Hanford Central Plateau.

Rockhold, Mark L.↗

VERIFICATION MEASUREMENTS OF THE MASS AND ENRICHMENT OF URANIUM OXIDE CARD SOURCES

Measurements were performed to determine the mass and enrichment of 10 uranium oxide (U3O8) card sources. The measurements and analysis were completed as a verification of the card sources in support of Oak Ridge National Laboratory’s nuclear material control and accountability program. Although these cards are not nationally accredited as a nuclear standard, they are used as a working reference for measurements, such as holdup. The uranium card source measurements were taken with a broad energy germanium detector and the Genie 2000 Gamma Acquisition and Analysis software. A complete characterization of each of the 10 uranium card sources was performed using the 4 characteristic full energy peaks of 235U. Using the In Situ Object Counting System software to determine the mathematical efficiency of the measurement, the mass of 235U in each card was determined. The 235U mass in each card ranged from 10.42 to 12.63 g with a systematic error between 0.76 and 0.95 g and a random error of 0.01 g for each card source. The Multi-Group Analysis for Uranium (MGAU) software and the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) isotopic analysis software were used to determine the isotopic composition of the uranium cards. The measured enrichment was compared to the declared enrichment for each card, with uncertainties ranging from 2.7% to 4.3% for the MGAU analysis and 2.3% to 4.1% for the FRAM analysis. This is a good example of how a well-benchmarked mathematical calibration method can be useful in characterizing uranium sources.

Hunneke, Rachel↗

The WRF-Solar Ensemble Prediction System: Development, Test, and Validation

Providing reliable probabilistic solar radiation information is needed to improve management of the uncertainty and variability of solar generation. Thus, guidance on how to develop skillful and accurate ensemble forecasts is essential and it will ultimately contribute to integration of high amounts of solar energy on the grid. A team from the National Renewable Energy Laboratory and the National Center for Atmospheric Research had been collaborating to develop the WRF-Solar ensemble prediction system (WRF-Solar EPS) in the past three years to produce probabilistic solar irradiance forecasts and better predict solar energy by quantifying forecast uncertainty. The WRF-Solar EPS basically generates ensemble members for solar irradiance based on stochastic perturbations to provide intraday and day-ahead probabilistic forecasts. This study will present main research steps in developing the WRF-Solar EPS including: (a) tangent linear analysis for identifying key input variables of six WRF-Solar modules significantly related to predicting of cloud and solar irradiance, (b) combining stochastic perturbation technique with the WRF-Solar model, and (c) ensemble calibration method to decrease error and uncertainty of ensemble-based solar forecasts. The capability of WRF-Solar EPS is now updated to the most recent version of standard WRF model. This presentation will summarize comprehensive results from the evaluation of forecasts against the National Solar Radiation Data Base as well as ground-measured observations. Moreover, we will introduce the user's guide for WRF-Solar EPS (e.g., parameters to configure stochastic perturbations) and future extension of this research.

day-ahead forecast↗

The ICEBERG Test Stand for DUNE Cold Electronics Development

ICEBERG is a liquid argon time projection chamber at Fermilab for the purpose of testing detector components and software for the Deep Underground Neutrino Experiment (DUNE). The detector features a 1.15m x 1m anode plane following the specifications of the DUNE horizontal drift far detector and a newly installed X-ARAPUCA photodetector. The status of ICEBERG is reported along with analysis of noise, pulser, and cosmic ray data from the ninth run beginning May 2024 with the goal of advising the DUNE collaboration on the optimal wire readout electronics configuration. In addition, development of an absolute energy scale calibration method is currently underway using known sources such as cosmic ray muon Michel electrons at the ~10 MeV scale and $^{39}$Ar decay electrons at the ~100keV scale. Research into AI-based identification of such events at the data acquisition level is introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Imaging of Surface Motion with a Stereo Borescope

A new stereo borescope has been investigated that would provide a time-resolved calibrated method of recording the motion and deformation of a three-dimensional (3-D) surface during explosively driven dynamic shock experiments at the Nevada Test Site. In these experiments, geometries would likely prove to be incompatible with conventional direct optical systems. Single line-of-sight borescopes lack adequate depth-of-field for quantitative imaging of the 3-D surface. To improve depth-of-field and provide time resolution, a stereo borescope has been fabricated for use with a nine-frame framing camera. At one end, stereo optics couple light from the dynamic surface into a pair of flexible 1-mm-diameter correlated fiber-optic bundles. At the other end, small-format lenses (~3 mm) interface with the framing camera, which is set up to simultaneously record the separate-perspective views. All nine frames could be recorded in a period as short as 1.8 μs, and spatial resolution is optimized to 11 line-pairs per mm. To achieve pseudo 3-D depth perception, photogrammetric analysis has been demonstrated with commercial software from ADAM technology (Australia). This paper presents the results from time-resolved stereo images of dynamic surfaces collected in a series of high-explosives experiments at the National Security Technologies, LLC, “Boom Box” in Santa Barbara, CA. Experience with the stereo borescope has suggested other potentially useful stereoscopic applications, such as stereo viewing of moving surfaces on the interiors of engines and the heating of moving components, and the viewing material deposition on interior surfaces during machine operations and fabrication processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feedback mechanism for smart nozzles and nebulizers

Nozzles and nebulizers able to produce aerosol with optimum and reproducible quality based on feedback information obtained using laser imaging techniques. Two laser-based imaging techniques based on particle image velocimetry (PTV) and optical patternation map and contrast size and velocity distributions for indirect and direct pneumatic nebulizations in plasma spectrometry. Two pulses from thin laser sheet with known time difference illuminate droplets flow field. Charge coupled device (CCL)) captures scattering of laser light from droplets, providing two instantaneous particle images. Pointwise cross-correlation of corresponding images yields two-dimensional velocity map of aerosol velocity field. For droplet size distribution studies, solution is doped with fluorescent dye and both laser induced florescence (LIF) and Mie scattering images are captured simultaneously by two CCDs with the same field of view. Ratio of LIF/Mie images provides relative droplet size information, then scaled by point calibration method via phase Doppler particle analyzer.

47 OTHER INSTRUMENTATION↗

STELLAR COLOR REGRESSION: A SPECTROSCOPY-BASED METHOD FOR COLOR CALIBRATION TO A FEW MILLIMAGNITUDE ACCURACY AND THE RECALIBRATION OF STRIPE 82

In this paper we propose a spectroscopy-based stellar color regression (SCR) method to perform accurate color calibration for modern imaging surveys, taking advantage of millions of stellar spectra now available. The method is straightforward, insensitive to systematic errors in the spectroscopically determined stellar atmospheric parameters, applicable to regions that are effectively covered by spectroscopic surveys, and capable of delivering an accuracy of a few millimagnitudes for color calibration. As an illustration, we have applied the method to the Sloan Digital Sky Survey (SDSS) Stripe 82 data. With a total number of 23,759 spectroscopically targeted stars, we have mapped out the small but strongly correlated color zero-point errors present in the photometric catalog of Stripe 82, and we improve the color calibration by a factor of two to three. Our study also reveals some small but significant magnitude dependence errors in the z band for some charge-coupled devices (CCDs). Such errors are likely to be present in all the SDSS photometric data. Our results are compared with those from a completely independent test based on the intrinsic colors of red galaxies presented by Ivezić et al. The comparison, as well as other tests, shows that the SCR method has achieved a color calibration internally consistent at a level of about 5 mmag in u – g, 3 mmag in g – r, and 2 mmag in r – i and i – z. Given the power of the SCR method, we discuss briefly the potential benefits by applying the method to existing, ongoing, and upcoming imaging surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of the MCMC Method for the Calibration of DSMC Parameters

A Markov Chain Monte Carlo (MCMC) algorithm was employed to obtain a calibrated distribution for the hard sphere diameter, the VHS reference diameter, and the temperature viscosity exponent of argon, for use in the Direct Simulation Monte Carlo (DSMC) method. Shock-tube experiments from Alsmeyer [1] were used to provide the necessary calibration data for use in the MCMC method. The DSMC method used in this work employs the algorithm of Bird [2], with modifications to allow for the efficient simulation of a 1D shock. When calibrating for the hard sphere diameter (the temperature viscosity exponent is set to 0.5 for the hard sphere method), the results of the MCMC method agree with a simple brute-force method, and a single value for the hard-sphere diameter is obtained. For the VHS method, however, when simultaneously calibrating the VHS reference diameter and the temperature viscosity exponent, we find that normalized density data alone does not provide sufficient information to obtain a single solution for both parameters. Instead we find a band in parameter space where acceptable solutions are obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sci-Thur PM - Colourful Interactions: Highlights 06: Patient-specific calibration of cone-beam computed tomographic (CBCT) image sets for on-line dose tracking and plan assessment

Purpose: To develop a radiotherapy dose tracking and plan evaluation technique using cone-beam computed tomography (CBCT) images. Methods: We developed a patient-specific method of calibrating CBCT image sets for dose calculation. The planning CT was first registered with the CBCT using deformable image registration (DIR). A scatter plot was generated between the CT numbers of the planning CT and CBCT for each slice. The CBCT calibration curve was obtained by least-square fitting of the data, and applied to each CBCT slice. The calibrated CBCT was then merged with original planning CT to extend the small field of view of CBCT. Finally, the treatment plan was copied to the merged CT for dose tracking and plan evaluation. The proposed patient-specific calibration method was also compared to two methods proposed in literature. To evaluate the accuracy of each technique, 15 head-and-neck patients requiring plan adaptation were arbitrarily selected from our institution. The original plan was calculated on each method’s data set, including a second planning CT acquired within 48 hours of the CBCT (serving as gold standard). Clinically relevant dose metrics and 3D gamma analysis of dose distributions were compared between the different techniques. Results: Compared to the gold standard of using planning CTs, the patient-specific CBCT calibration method was shown to provide promising results with gamma pass rates above 95% and average dose metric agreement within 2.5%. Conclusions: The patient-specific CBCT calibration method could potentially be used for on-line dose tracking and plan evaluation, without requiring a re-planning CT session.

60 APPLIED LIFE SCIENCES↗

An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors’ limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.

Instruments & Instrumentation↗

Discrete-Direct Model Calibration and Uncertainty Propagation Method Confirmed on Multi-Parameter Plasticity Model Calibrated to Sparse Random Field Data

A discrete direct (DD) model calibration and uncertainty propagation approach is explained and demonstrated on a 4-parameter Johnson-Cook (J-C) strain-rate dependent material strength model for an aluminum alloy. The methodology's performance is characterized in many trials involving four random realizations of strain-rate dependent material-test data curves per trial, drawn from a large synthetic population. The J-C model is calibrated to particular combinations of the data curves to obtain calibration parameter sets which are then propagated to “Can Crush” structural model predictions to produce samples of predicted response variability. These are processed with appropriate sparse-sample uncertainty quantification (UQ) methods to estimate various statistics of response with an appropriate level of conservatism. This is tested on 16 output quantities (von Mises stresses and equivalent plastic strains) and it is shown that important statistics of the true variabilities of the 16 quantities are bounded with a high success rate that is reasonably predictable and controllable. The DD approach has several advantages over other calibration-UQ approaches like Bayesian inference for capturing and utilizing the information obtained from typically small numbers of replicate experiments in model calibration situations—especially when sparse replicate functional data are involved like force–displacement curves from material tests. The DD methodology is straightforward and efficient for calibration and propagation problems involving aleatory and epistemic uncertainties in calibration experiments, models, and procedures.

42 ENGINEERING↗

Transconvolution and the virtual positron emission tomograph-A new method for cross calibration in quantitative PET/CT imaging

Purpose: Positron emission tomography (PET)/computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET/CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET/CT in the context of multicenter trials. Methods: To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET/CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET/CT systems, a dedicated solid-state phantom incorporating {sup 68}Ge/{sup 68}Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET/CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. Results: The proposed Transconvolution method matched different PET/CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. Conclusions: By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiochromic film dosimetry with flatbed scanners: A fast and accurate method for dose calibration and uniformity correction with single film exposure

Film dosimetry is an attractive tool for dose distribution verification in intensity modulated radiotherapy (IMRT). A critical aspect of radiochromic film dosimetry is the scanner used for the readout of the film: the output needs to be calibrated in dose response and corrected for pixel value and spatial dependent nonuniformity caused by light scattering; these procedures can take a long time. A method for a fast and accurate calibration and uniformity correction for radiochromic film dosimetry is presented: a single film exposure is used to do both calibration and correction. Gafchromic EBT films were read with two flatbed charge coupled device scanners (Epson V750 and 1680Pro). The accuracy of the method is investigated with specific dose patterns and an IMRT beam. The comparisons with a two-dimensional array of ionization chambers using a 18x18 cm{sup 2} open field and an inverse pyramid dose pattern show an increment in the percentage of points which pass the gamma analysis (tolerance parameters of 3% and 3 mm), passing from 55% and 64% for the 1680Pro and V750 scanners, respectively, to 94% for both scanners for the 18x18 open field, and from 76% and 75% to 91% for the inverse pyramid pattern. Application to an IMRT beam also shows better gamma index results, passing from 88% and 86% for the two scanners, respectively, to 94% for both. The number of points and dose range considered for correction and calibration appears to be appropriate for use in IMRT verification. The method showed to be fast and to correct properly the nonuniformity and has been adopted for routine clinical IMRT dose verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗