Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Live cell imaging of cellular dynamics in poplar wood using computational cannula microscopy

This study presents significant advancements in computational cannula microscopy for live imaging of cellular dynamics in poplar wood tissues. Leveraging machine-learning models such as pix2pix for image reconstruction, we achieved high-resolution imaging with a field of view of 55µm using a 50µm-core diameter probe. Our method allows for real-time image reconstruction at 0.29 s per frame with a mean absolute error of 0.07. We successfully captured cellular-level dynamics in vivo , demonstrating morphological changes at resolutions as small as 3µm. We implemented two types of probabilistic neural network models to quantify confidence levels in the reconstructed images. This approach facilitates context-aware, human-in-the-loop analysis, which is crucial for in vivo imaging where ground-truth data is unavailable. Using this approach we demonstrated deep in vivo computational imaging of living plant tissue with high confidence (disagreement score ⪅0.2). This work addresses the challenges of imaging live plant tissues, offering a practical and minimally invasive tool for plant biologists.

Ingold, Alexander (ORCID:0009000752380016)↗

SU-E-P-54: Evaluation of the Accuracy and Precision of IGPS-O X-Ray Image-Guided Positioning System by Comparison with On-Board Imager Cone-Beam Computed Tomography

Purpose: The purpose of this study is to assess the positioning accuracy and precision of IGPS-O system which is a novel radiographic kilo-voltage x-ray image-guided positioning system developed for clinical IGRT applications. Methods: IGPS-O x-ray image-guided positioning system consists of two oblique sets of radiographic kilo-voltage x-ray projecting and imaging devices which were equiped on the ground and ceiling of treatment room. This system can determine the positioning error in the form of three translations and three rotations according to the registration of two X-ray images acquired online and the planning CT image. An anthropomorphic head phantom and an anthropomorphic thorax phantom were used for this study. The phantom was set up on the treatment table with correct position and various “planned” setup errors. Both IGPS-O x-ray image-guided positioning system and the commercial On-board Imager Cone-beam Computed Tomography (OBI CBCT) were used to obtain the setup errors of the phantom. Difference of the Result between the two image-guided positioning systems were computed and analyzed. Results: The setup errors measured by IGPS-O x-ray image-guided positioning system and the OBI CBCT system showed a general agreement, the means and standard errors of the discrepancies between the two systems in the left-right, anterior-posterior, superior-inferior directions were −0.13±0.09mm, 0.03±0.25mm, 0.04±0.31mm, respectively. The maximum difference was only 0.51mm in all the directions and the angular discrepancy was 0.3±0.5° between the two systems. Conclusion: The spatial and angular discrepancies between IGPS-O system and OBI CBCT for setup error correction was minimal. There is a general agreement between the two positioning system. IGPS-O x-ray image-guided positioning system can achieve as good accuracy as CBCT and can be used in the clinical IGRT applications.

60 APPLIED LIFE SCIENCES↗

Fluorescent X-Ray Computed Tomography towards Molecular Imaging: Proof-of-Concept Experiments

By means of fluorescent x-ray computed tomography (FXCT) one can detect and image a distribution of non-radioactive imaging agent, e.g., iodine, in a biomedical subject at a high spatial resolution, so it can be a novel molecular imaging modality. We have been studying an FXCT system using synchrotron radiation for in-vivo imaging brains of small animals such as mouse, or rat. For the purpose, we propose a fast FXCT imaging method based on the novel geometry. In this study, we prove the feasibility of this concept and investigate its imaging properties, including spatial and contrast resolutions and quantitativeness, by imaging an acrylic phantom and a normal mouse brain using a preliminary imaging system with monochromatic synchrotron x rays.

60 APPLIED LIFE SCIENCES↗

Image Analysis via Soft Computing: Prototype Applications at NASA KSC and Product Commercialization

This slide presentation reviews the use of "soft computing" which differs from "hard computing" in that it is more tolerant of imprecision, partial truth, uncertainty, and approximation and its use in image analysis. Soft computing provides flexible information processing to handle real life ambiguous situations and achieve tractability, robustness low solution cost, and a closer resemblance to human decision making. Several systems are or have been developed: Fuzzy Reasoning Edge Detection (FRED), Fuzzy Reasoning Adaptive Thresholding (FRAT), Image enhancement techniques, and visual/pattern recognition. These systems are compared with examples that show the effectiveness of each. NASA applications that are reviewed are: Real-Time (RT) Anomaly Detection, Real-Time (RT) Moving Debris Detection and the Columbia Investigation. The RT anomaly detection reviewed the case of a damaged cable for the emergency egress system. The use of these techniques is further illustrated in the Columbia investigation with the location and detection of Foam debris. There are several applications in commercial usage: image enhancement, human screening and privacy protection, visual inspection, 3D heart visualization, tumor detections and x ray image enhancement.

Dominguez, Jesus A.↗

Mapping of Benthic Habitats at Marine Renewable Energy Sites Using Multibeam Echosounder and Sediment Profile Imaging Technologies

Objectives/Scope: The goal of this work was to develop a consistent and semi-automated seafloor survey method for generating high-resolution, benthic habitat maps for environmental assessments and monitoring of marine renewable energy sites. Sediment profile and plan view imaging (SPI/PV) technology was combined with multibeam bathymetry and acoustic backscatter methods to demonstrate a rapid, cost-effective benthic mapping protocol. A key technical innovation of this project was the development of an image processing platform that automatically measures key features from the images. Methods: Multibeam echosounder (MBES) acoustic and SPI/PV surveys were conducted at three coastal areas off the U.S. west coast, including the PacWave South energy test site off of Newport, Oregon. Point data on physical and biological sediment conditions obtained from the SPI/PV imagery were used to efficiently ground-truth the high-resolution MBES bathymetry and backscatter mosaics. The SPI camera is an optical corer that obtains an undisturbed 21 by 15 cm, high-resolution, cross-sectional image of the sediment–water interface and upper sediment column. The plan view camera attached to the SPI camera frame captures a downward looking view of the seabed immediately before the SPI image is obtained. As part of this project, we developed a computer vision image processing platform (iSPI) that uses deep convolutional neural networks and other approaches to automatically identify and measure key features in the images, such as grain size and surface relief. Results: Detailed benthic habitat maps were generated using this mapping approach for three different marine settings. The sites mapped included a silt-dominated embayment; a sloping, nearshore, transitional very fine to coarse sand bottom; and a medium, sand-dominated continental shelf marine energy test site. In each case, acoustic and imaging surveys were completed in less than week, and detailed benthic habitat maps were generated within 60 days. The results were placed within the Coastal and Marine Ecological Classification Standard (CMECS) habitat mapping framework, and various combinations of the bathymetry, backscatter, and SPI and PV data were used to generate CMECS component maps. Novel Information: This project developed and demonstrated a repeatable and cost-effective approach for efficiently mapping benthic habitat conditions over broad areas of the seafloor by combining state-of-the-art acoustic and imaging techniques. The primary survey tools used in this project have been used previously in both the offshore renewable (wind) and oil and gas sectors to map and monitor benthic environments. This project’s innovations include 1) the focused use of high-resolution SPI/PV imagery to ground-truth acoustic mosaics, and 2) the development of a computer automated image analysis processing tool that both streamlines and standardizes the generation of data from the imagery and makes the data extraction process more cost-effective and repeatable.

13 HYDRO ENERGY↗

Quality Assurance Issues for Computed Tomography-, Ultrasound-, and Magnetic Resonance Imaging-Guided Brachytherapy

The requirements of quality assurance (QA) for both brachytherapy and imaging devices are well-defined, but image-guided brachytherapy has raised new issues. Image guidance in brachytherapy involves the transition from reference point dosimetry using films to volumetric imaging such as computed tomography, ultrasonography, and magnetic resonance imaging for treatment planning and guidance of applicator, needle, or seed placement. The QA of these devices might not reflect the conditions of use in brachytherapy or the requirements of brachytherapy treatment planning. Image interpretation becomes much more important with image-guided brachytherapy. The success of a procedure could depend on the interpretation of a single image in a calibration phase done under the time pressures of the operative setting. This change has implications at the level of treatment, the process, and the field of brachytherapy as a whole. The QA concerns arising from brachytherapy procedures using ultrasound, computed tomography, and magnetic resonance imaging guidance are discussed, as are the problems associated with using imaging in an interventional setting. This report was intended to indicate the QA concerns arising from the convergence of brachytherapy and imaging-highlighting areas in which technical improvements are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Differences for Computed Tomography and Magnetic Resonance Imaging Segmentation and Planning for Proton Prostate Cancer Therapy

Purpose: To determine the influence of magnetic-resonance-imaging (MRI)-vs. computed-tomography (CT)-based prostate and normal structure delineation on the dose to the target and organs at risk during proton therapy. Methods and Materials: Fourteen patients were simulated in the supine position using both CT and T2 MRI. The prostate, rectum, and bladder were delineated on both imaging modalities. The planning target volume (PTV) was generated from the delineated prostates with a 5-mm axial and 8-mm superior and inferior margin. Two plans were generated and analyzed for each patient: an MRI plan based on the MRI-delineated PTV, and a CT plan based on the CT-delineated PTV. Doses of 78 Gy equivalents (GE) were prescribed to the PTV. Results: Doses to normal structures were lower when MRI was used to delineate the rectum and bladder compared with CT: bladder V50 was 15.3% lower (p = 0.04), and rectum V50 was 23.9% lower (p = 0.003). Poor agreement on the definition of the prostate apex was seen between CT and MRI (p = 0.007). The CT-defined prostate apex was within 2 mm of the apex on MRI only 35.7% of the time. Coverage of the MRI-delineated PTV was significantly decreased with the CT-based plan: the minimum dose to the PTV was reduced by 43% (p < 0.001), and the PTV V99% was reduced by 11% (p < 0.001). Conclusions: Using MRI to delineate the prostate results in more accurate target definition and a smaller target volume compared with CT, allowing for improved target coverage and decreased doses to critical normal structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-cost digital image processing on a university mainframe computer

The advantages and limitations of using university mainframe computers in digital image processing instruction are listed. Aspects to be considered when designing software for this purpose include not only two general audience, but also the capabilities of the system regarding the size of the image/subimage, preprocessing and enhancement functions, geometric correction and registration techniques; classification strategy, classification algorithm, multitemporal analysis, and ancilliary data and geographic information systems. The user/software/hardware interaction as well as acquisition and operating costs must also be considered.

Williams, T. H. L.↗

SSME leak detection feasibility investigation by utilization of infrared sensor technology

This investigation examined the potential of using state-of-the-art technology of infrared (IR) thermal imaging systems combined with computer, digital image processing and expert systems for Space Shuttle Main Engines (SSME) propellant path peak detection as an early warning system of imminent engine failure. A low-cost, laboratory experiment was devised and an experimental approach was established. The system was installed, checked out, and data were successfully acquired demonstrating the proof-of-concept. The conclusion from this investigation is that both numerical and experimental results indicate that the leak detection by using infrared sensor technology proved to be feasible for a rocket engine health monitoring system.

Shohadaee, Ahmad A.↗

SSME Propellant Path Leak Detection

The primary objective of this phase of the investigation is the experimental validation of techniques for detecting and analyzing propellant path external leaks which have a high probability of occurring on the SSME. The selection of candidate detection methods requires a good analytic model for leak plumes which would develop from external leaks and an understanding of radiation transfer through the leak plume. One advanced propellant path leak detection technique is obtained by using state-of-art technology of infrared (IR) thermal imaging systems combined with computer, digital image processing and expert systems for the engine protection. The feasibility of the IR leak plume detection will be evaluated on subscale simulated laboratory plumes to determine sensitivity, signal to noise, and general suitability for the application. The theoretical analysis was undertaken with the objective of developing and testing simple, easy-to-use models to predict the amount of radiation coming from a radiation source, background plate (BP), which can be absorbed, emitted and scattered by the gas leaks.

Roger Crawford↗

SSME Propellant Path Leak Detection

The complicated high-pressure cycle of the space shuttle main engine (SSME) propellant path provides many opportunities for external propellant path leaks while the engine is running. This mode of engine failure may be detected and analyzed with sufficient speed to save critical engine test hardware from destruction. The leaks indicate hardware failures which will damage or destroy an engine if undetected; therefore, detection of both cryogenic and hot gas leaks is the objective of this investigation. The primary objective of this phase of the investigation is the experimental validation of techniques for detecting and analyzing propellant path external leaks which have a high probability of occurring on the SSME. The selection of candidate detection methods requires a good analytic model for leak plumes which would develop from external leaks and an understanding of radiation transfer through the leak plume. One advanced propellant path leak detection technique is obtained by using state-of-the-art technology infrared (IR) thermal imaging systems combined with computer, digital image processing, and expert systems for the engine protection. The feasibility of IR leak plume detection is evaluated on subscale simulated laboratory plumes to determine sensitivity, signal to noise, and general suitability for the application.

Roger Crawford↗

NASA Tech Briefs, March 2010

Topics covered include: Software Tool Integrating Data Flow Diagrams and Petri Nets; Adaptive Nulling for Interferometric Detection of Planets; Reducing the Volume of NASA Earth-Science Data; Reception of Multiple Telemetry Signals via One Dish Antenna; Space-Qualified Traveling-Wave Tube; Smart Power Supply for Battery-Powered Systems; Parallel Processing of Broad-Band PPM Signals; Inexpensive Implementation of Many Strain Gauges; Constant-Differential-Pressure Two-Fluid Accumulator; Inflatable Tubular Structures Rigidized with Foams; Power Generator with Thermo-Differential Modules; Mechanical Extraction of Power From Ocean Currents and Tides; Nitrous Oxide/Paraffin Hybrid Rocket Engines; Optimized Li-Ion Electrolytes Containing Fluorinated Ester Co-Solvents; Probabilistic Multi-Factor Interaction Model for Complex Material Behavior; Foldable Instrumented Bits for Ultrasonic/Sonic Penetrators; Compact Rare Earth Emitter Hollow Cathode; High-Precision Shape Control of In-Space Deployable Large Membrane/Thin-Shell Reflectors; Rapid Active Sampling Package; Miniature Lightweight Ion Pump; Cryogenic Transport of High-Pressure-System Recharge Gas; Water-Vapor Raman Lidar System Reaches Higher Altitude; Compact Ku-Band T/R Module for High-Resolution Radar Imaging of Cold Land Processes; Wide-Field-of-View, High-Resolution, Stereoscopic Imager; Electrical Capacitance Volume Tomography with High-Contrast Dielectrics; Wavefront Control and Image Restoration with Less Computing; Polarization Imaging Apparatus; Stereoscopic Machine-Vision System Using Projected Circles; Metal Vapor Arcing Risk Assessment Tool; Performance Bounds on Two Concatenated, Interleaved Codes; Parameterizing Coefficients of a POD-Based Dynamical System; Confidence-Based Feature Acquisition; Algorithm for Lossless Compression of Calibrated Hyperspectral Imagery; Universal Decoder for PPM of any Order; Algorithm for Stabilizing a POD-Based Dynamical System; Mission Reliability Estimation for Repairable Robot Teams; Processing AIRS Scientific Data Through Level 3; Web-Based Requesting and Scheduling Use of Facilities; AutoGen Version 5.0; Time-Tag Generation Script; PPM Receiver Implemented in Software; Tropospheric Emission Spectrometer Product File Readers; Reporting Differences Between Spacecraft Sequence Files; Coordinating "Execute" Data for ISS and Space Shuttle; Database for Safety-Oriented Tracking of Chemicals; Apparatus for Cold, Pressurized Biogeochemical Experiments; Growing B Lymphocytes in a Three-Dimensional Culture System; Tissue-like 3D Assemblies of Human Broncho-Epithelial Cells; Isolation of Resistance-Bearing Microorganisms; Oscillating Cell Culture Bioreactor; and Liquid Cooling/Warming Garment.

Source record↗

Controlled Formation of Conduction Channels in Memristive Devices Observed by X–ray Multimodal Imaging

Neuromorphic computing provides a means for achieving faster and more energy efficient computations than conventional digital computers for artificial intelligence (AI). However, its current accuracy is generally less than the dominant software-based AI. The key to improving accuracy is to reduce the intrinsic randomness of memristive devices, emulating synapses in the brain for neuromorphic computing. Here using a planar device as a model system, the controlled formation of conduction channels is achieved with high oxygen vacancy concentrations through the design of sharp protrusions in the electrode gap, as observed by X-ray multimodal imaging of both oxygen stoichiometry and crystallinity. Classical molecular dynamics simulations confirm that the controlled formation of conduction channels arises from confinement of the electric field, yielding a reproducible spatial distribution of oxygen vacancies across switching cycles. Furthermore, this work demonstrates an effective route to control the otherwise random electroforming process by electrode design, facilitating the development of more accurate memristive devices for neuromorphic computing.

36 MATERIALS SCIENCE↗

Computer-generated 3D ultrasound images of the carotid artery

A method is under development to measure carotid artery lesions from a computer-generated three-dimensional ultrasound image. For each image, the position of the transducer in six coordinates (x, y, z, azimuth, elevation, and roll) is recorded and used to position each B-mode picture element in its proper spatial position in a three-dimensional memory array. After all B-mode images have been assembled in the memory, the three-dimensional image is filtered and resampled to produce a new series of parallel-plane two-dimensional images from which arterial boundaries are determined using edge tracking methods.

Selzer, Robert H.↗

Onboard Data Processor for Change-Detection Radar Imaging

A computer system denoted a change-detection onboard processor (CDOP) is being developed as a means of processing the digitized output of a synthetic-aperture radar (SAR) apparatus aboard an aircraft or spacecraft to generate images showing changes that have occurred in the terrain below between repeat passes of the aircraft or spacecraft over the terrain. When fully developed, the CDOP is intended to be capable of generating SAR images and/or SAR differential interferograms in nearly real time. The CDOP is expected to be especially useful for understanding some large-scale natural phenomena and/or mitigating natural hazards: For example, it could be used for near-real-time observation of surface changes caused by floods, landslides, forest fires, volcanic eruptions, earthquakes, glaciers, and sea ice movements. It could also be used to observe such longer-term surface changes as those associated with growth of vegetation (relevant to estimation of wildfire fuel loads). The CDOP is, essentially, an interferometric SAR processor designed to operate aboard a radar platform.

Lou, Yunling↗

Digital image processing on a small computer system

A minicomputer-based image processing facility provides a relatively low-cost entry point for education about image analysis applications in remote sensing. While a minicomputer has sufficient processing power to produce results quite rapidly for low volumes of small images, it does not have sufficient power to perform CPU- or 1/0-bound tasks on large images. A system equipped with a display terminal is ideally suited for interactive tasks. Software procurement is a limiting factor for most end users, and software availability may well be the overriding consideration in selecting a particular hardware configuration. The hardware chosen should be selected to be compatible with the software and with concern for future expansion.

Danielson, R.↗

Computer processing of radiographic images

In the past 20 years, a substantial amount of effort has been expended on the development of computer techniques for enhancement of X-ray images and for automated extraction of quantitative diagnostic information. The historical development of these methods is described. Illustrative examples are presented and factors influencing the relative success or failure of various techniques are discussed. Some examples of current research in radiographic image processing is described.

Selzer, R. H.↗

SU-E-J-243: Possibility of Exposure Dose Reduction of Cone-Beam Computed Tomography in An Image Guided Patient Positioning System by Using Various Noise Suppression Filters

Purpose: To investigate the possibility of exposure dose reduction of the cone-beam computed tomography (CBCT) in an image guided patient positioning system by using 6 noise suppression filters. Methods: First, a reference dose (RD) and low-dose (LD)-CBCT (X-ray volume imaging system, Elekta Co.) images were acquired with a reference dose of 86.2 mGy (weighted CT dose index: CTDIw) and various low doses of 1.4 to 43.1 mGy, respectively. Second, an automated rigid registration for three axes was performed for estimating setup errors between a planning CT image and the LD-CBCT images, which were processed by 6 noise suppression filters, i.e., averaging filter (AF), median filter (MF), Gaussian filter (GF), bilateral filter (BF), edge preserving smoothing filter (EPF) and adaptive partial median filter (AMF). Third, residual errors representing the patient positioning accuracy were calculated as an Euclidean distance between the setup error vectors estimated using the LD-CBCT image and RD-CBCT image. Finally, the relationships between the residual error and CTDIw were obtained for 6 noise suppression filters, and then the CTDIw for LD-CBCT images processed by the noise suppression filters were measured at the same residual error, which was obtained with the RD-CBCT. This approach was applied to an anthropomorphic pelvic phantom and two cancer patients. Results: For the phantom, the exposure dose could be reduced from 61% (GF) to 78% (AMF) by applying the noise suppression filters to the CBCT images. The exposure dose in a prostate cancer case could be reduced from 8% (AF) to 61% (AMF), and the exposure dose in a lung cancer case could be reduced from 9% (AF) to 37% (AMF). Conclusion: Using noise suppression filters, particularly an adaptive partial median filter, could be feasible to decrease the additional exposure dose to patients in image guided patient positioning systems.

60 APPLIED LIFE SCIENCES↗