Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Room”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Control Board Digital Interface Input Devices – Touchscreen, Trackpad, or Mouse?

The authors collaborated with a power utility to evaluate input devices for use in the human system interface (HSI) for a new digital Turbine Control System (TCS) at a nuclear power plant (NPP) undergoing a TCS upgrade. A standalone dynamic software simulation of the new digital TCS and a mobile kiosk were developed to conduct an input device study to evaluate operator preference and input device effectiveness. The TCS software presented the anticipated HSI for the TCS and mimicked (i.e., simulated) the turbine systems’ responses to operator commands. Twenty-four licensed operators from the two nuclear power units participated in the study. Three input devices were tested: a trackpad, mouse, and touchscreen. The subjective feedback from the survey indicates the operators preferred the touchscreen interface. The operators subjectively rated the touchscreen as the fastest and most comfortable input device given the range of tasks they performed during the study, but also noted a lack of accuracy for selecting small targets. The empirical data suggest the mouse input device provides the most consistent performance for screen navigation and manipulating on screen controls. The trackpad input device was both empirically and subjectively found to be the least effective and least desired input device.

control room modernization↗

"Defense-in-Depth" Laser Safety and the National Ignition Facility

The National Ignition Facility (NIF) is the largest and most energetic laser in the world contained in a complex the size of a football stadium. From the initial laser pulse, provided by telecommunication style infrared nanoJoule pulsed lasers, to the final 192 laser beams (1.8 Mega Joules total energy in the ultraviolet) converging on a target the size of a pencil eraser, laser safety is of paramount concern. In addition to this, there are numerous high-powered (Class 3B and 4) diagnostic lasers in use that can potentially send their laser radiation travelling throughout the facility. With individual beam paths of up to 1500 meters and a workforce of more than one thousand, the potential for exposure is significant. Simple laser safety practices utilized in typical laser labs just don't apply. To mitigate these hazards, NIF incorporates a multi layered approach to laser safety or 'Defense in Depth.' Most typical high-powered laser operations are contained and controlled within a single room using relatively simplistic controls to protect both the worker and the public. Laser workers are trained, use a standard operating procedure, and are required to wear Personal Protective Equipment (PPE) such as Laser Protective Eyewear (LPE) if the system is not fully enclosed. Non-workers are protected by means of posting the room with a warning sign and a flashing light. In the best of cases, a Safety Interlock System (SIS) will be employed which will 'safe' the laser in the case of unauthorized access. This type of laser operation is relatively easy to employ and manage. As the operation becomes more complex, higher levels of control are required to ensure personnel safety. Examples requiring enhanced controls are outdoor and multi-room laser operations. At the NIF there are 192 beam lines and numerous other Class 4 diagnostic lasers that can potentially deliver their hazardous energy to locations far from the laser source. This presents a serious and complex potential hazard to personnel. Because of this, a multilayered approach to safety is taken. This paper presents the philosophy and approach taken at the NIF in the multi-layered 'defense-in-depth' approach to laser safety.

42 ENGINEERING↗

The Effects of Degraded Digital Instrumentation and Control Systems on Human-system Interfaces and Operator Performance: HFE Review Guidance and Technical Basis

New and advanced reactors will use integrated digital instrumentation and control (I&C) systems to support operators in their monitoring and control functions. Even though digital systems are typically highly reliable, their potential for degradation or failure could significantly affect operator performance and, consequently, impact plant safety. The U.S. Nuclear Regulatory Commission (NRC) supported this research project to investigate the effects of degraded I&C systems on human performance and plant operations. The objective was to develop human factors engineering (HFE) review guidance addressing the detection and management of degraded digital I&C conditions by plant operators. We reviewed pertinent standards and guidelines, empirical studies, and plant operating experience. In addition, we conducted an evaluation of the potential effects of selected failure modes of the digital feedwater system on human-system interfaces (HSIs) and operator performance. The results indicated that I&C degradations are prevalent in plants employing digital systems and the overall effects on plant behavior can be significant, such as causing a reactor trip or causing equipment to operate unexpectedly. I&C degradations can impact the HSIs used by operators to monitor and control the plant. For example, sensor degradations can make displays difficult to interpret and can sometimes mislead operators by making it appear that a process disturbance has occurred. We used the information obtained as the technical basis upon which to develop HFE review guidance. The guidance addresses the treatment of degraded I&C conditions as part of the design process and the HSI features and functions that support operators to monitor I&C performance and manage I&C degradations when they occur. In addition, we identified topics for future research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dataset: Inferring Thermal Comfort using Body Shape Information Utilizing Depth Sensors

Thermal comfort is very important for well-being and productivity of building occupants. It has been shown that body shape is a useful feature to determine thermal comfort of individuals [2]. It is because, the heat dissipation rate of individuals depends on the body surface area. As a result, a tall and skinny person can tolerate higher room temperature than a rounded body shape person [5]. In order to test this hypothesis, we performed a year-long experiment in 2017, where we recruited 77 participants and put each of them in a thermally controlled conference room in CMU for 3 hours and recorded their subjective responses regarding thermal comfort at different temperature ranging from 60°F to 80°F. In addition, we collected depth data of individuals using a vertically mounted Microsoft Kinect for XBOX One at the entrance of the conference room to capture their body shape. We also collected biometric features (e.g., Galvanic Skin Response (GSR), skin temperature) using a Microsoft Health Band worn by the subjects. The resulting dataset provides rich information regarding how different features can be used to infer thermal comfort of the individuals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploration of Optimizing FPGA-based Qubit Controller for Experiments on Superconducting Quantum Computing Hardware

This work explores avenues and target areas for optimizing FPGA-based control hardware for experiments conducted on superconducting quantum computing systems and serves as an introduction to some of the current research at the intersection of classical and quantum computing hardware. With the promise of building larger-scale error-corrected quantum computers based on superconducting qubit architecture, innovations to room-temperature control electronics are needed to bring these quantum realizations to fruition. The QICK (Quantum Instrumentation Control Kit) is one leading experimental FPGA-based implementations. However, its integration into other experimental quantum computing architectures, especially those using superconducting radiofrequency (SRF) cavities, is largely unexplored. We identify some key target areas for optimizing control electronics for superconducting qubit architectures and provide some preliminary results to the resolution of a control pulse waveform. With optimizations targeted at 3D superconducting qubit setups, we hope to bring to light some of the requirements in classical computational methodologies to bring out the full potential of this quantum computing architecture, and to convey the excitement of progress in this research.

43 PARTICLE ACCELERATORS↗

Controllable oxygen vacancy defect engineering of BiVO 4 porous structures for room temperature NH 3 detection

Controlling structural features of sensing material while judiciously introducing vacancy defect states for revamping the electronic properties of the sample to obtain its superior gas sensing performance, is quite rare. Herein, we report for the first time, the room temperature (RT) ammonia (NH 3 ) detection of peanut-like porous bismuth vanadate (BiVO 4 ) with a stable monoclinic phase. The developed BiVO 4 possess abundant oxygen vacancies and porosity by virtue of calcinations (400–800 ℃). BiVO 4 calcined at 400 ℃ exhibits high selectivity towards NH 3 with a maximum response of 1421 @ 270 ppm at RT, which is 2.5 fold enhanced compared to without calcined BiVO 4 (response of 547 @ 270 ppm NH 3 ). The oxygen defective BiVO 4 appeared highly durable and stable even under high humid conditions (∼60 %). Besides, the porosity of BiVO 4 not only enhances the specific surface area (19.8 m 2 /g) but also results in fast diffusion of NH 3 molecules, leading to a reduction in the decay time (34 s for 90 ppm NH 3 ). The density functional theory (DFT) uncovers that the oxygen vacancy formation in BiVO 4 augments the NH 3 sensing capabilities by enhancing the adsorption energy of NH 3 . This work provides insight into the sensing mechanism of increased response caused by defect engineering and porosity, which will be favourable for fabricating high-performance NH 3 sensors at RT.

DFT analysis↗

Optimization of synthesis protocols to control the nanostructure and the morphology of metal oxide thin films for memristive applications

We propose a multi-technique approach based on in-vacuum synthesis of metal oxides to optimize the memristive properties of devices that use a metal oxide thin film as insulating layer. Pulsed Microplasma Cluster Source (PMCS) is based on supersonic beams seeded by clusters of the metal oxide. Nanocrystalline TiO{sub 2} thin films can be grown at room temperature, controlling the oxide stoichiometry from titanium metal up to a significant oxygen excess. Pulsed Electron beam Deposition (PED) is suitable to grow crystalline thin films on large areas, a step towards producing device arrays with controlled morphology and stoichiometry. Atomic Layer Deposition (ALD) is a powerful technique to grow materials layer-by-layer, finely controlling the chemical and structural properties of the film up to thickness of 50-80 nm. We will present a few examples of metal-insulator-metal structures showing a pinched hysteresis loop in their current-voltage characteristic. The structure, stoichiometry and morphology of the metal oxide layer, either aluminum oxide or titanium dioxide, is investigated by means of scanning electron microscopy (SEM) and by Raman scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of Semimagnetic Mn-Doped WO{sub 3} Nanoparticles Synthesised by Precipitation Method: Hydrogenation Creates a Promising DMS

Abstract Tungsten oxide (WO{sub 3}) nanoparticles doped with different amounts of manganese ions (W{sub 1−x}Mn{sub x}O{sub 3}, where x = 0.011, 0.022 and 0.044) were synthesised by hydraulic acid-assisted precipitation, followed by thermal calcinations. The powders were characterised by X-ray fluorescence (XRF), X-ray diffraction (XRD), diffuse reflectance spectroscopy (DRS) and magnetic measurements. The monoclinic structure at room temperature (∼293 K) found for un-doped WO{sub 3} was preserved even with Mn doping. However, doping with Mn ions caused decease in unit-cell volume and slight increase in crystallite size (CS) of host WO{sub 3}. The hydrogenation was observed to corrode the crystallites without changing in crystalline structure. Controllable room-temperature ferromagnetic (RT-FM) properties were obviously observed with hydrogenated WO{sub 3} doped with Mn. In addition, there existed an optimum doping concentration of Mn in WO{sub 3} to obtain superior FM properties. Therefore, Mn-doped WO{sub 3} nanopowders, owning to these amazingly tunable magnetic properties, could be considered a potential candidate for many applications partially required FM properties such as optical phosphors and catalysts.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast, high-fidelity, all-optical and dynamically-controlled polarization gate using room-temperature atomic vapor

We demonstrate a fast, all-optical polarization gate in a room-temperature atomic medium. Using a Polarization-Selective-Kerr-Phase-Shift (PSKPS) technique, we selectively write a π phase shift to one circularly-polarized component of a linearly-polarized input signal field. The output signal field maintains its original strength but acquires a 90° linear polarization rotation, demonstrating fast, high-fidelity, dynamically-controlled polarization gate operation. The intensity of the polarization-switching field used in this PKSPK-based polarization gate operation is only 2 mW/cm{sup 2}, which would be equivalent to 0.5 nW of light power (λ = 800 nm) confined in a typical commercial photonic hollow-core fiber. This development opens a realm of possibilities for potential future extremely low light level telecommunication and information processing systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-273: Radiation Shielding for a Fixed Horizontal-Beam Linac in a Shipping Container and a Conventional Treatment Vault

Purpose: A fixed horizontal-beam linac, where the patient is treated in a seated position, could lower the overall costs of the treatment unit and room shielding substantially. This design also allows the treatment room and control area to be contained within a reduced space, such as a shipping container. The main application is the introduction of low-cost, high-quality radiation therapy to low- and middle-income regions. Here we consider shielding for upright treatments with a fixed-6MV-beam linac in a shipping container and a conventional treatment vault. Methods: Shielding calculations were done for two treatment room layouts using calculation methods in NCRP Report 151: (1) a shipping container (6m × 2.4m with the remaining space occupied by the console area), and (2) the treatment vault in NCRP 151 (7.8m by 5.4m by 3.4m). The shipping container has a fixed gantry that points in one direction at all times. For the treatment vault, various beam directions were evaluated. Results: The shipping container requires a primary barrier of 168cm concrete (4.5 TVL), surrounded by a secondary barrier of 3.6 TVL. The other walls require between 2.8–3.3 TVL. Multiple shielding calculations were done along the side wall. The results show that patient scatter increases in the forward direction and decreases dramatically in the backward direction. Leakage scatter also varies along the wall, depending largely on the distance between the gantry and the wall. For the treatment room, fixed-beam requires a slightly thicker primary barrier than the conventional linac (0.6 TVL), although this barrier is only needed in the center of one wall. The secondary barrier is different only by 0–0.2 TVL. Conclusion: This work shows that (1) the shipping container option is achievable, using indigenous materials for shielding and (2) upright treatments can be performed in a conventional treatment room with minimal additional shielding. Varian Medical Systems.

07 ISOTOPE AND RADIATION SOURCES↗

The Impact of Wall Control Performance on Connected Lighting Systems

Wall controls form the only touchpoint for individual room users and that room’s lighting control system. As such, these interfaces strongly influence user understanding and utilization of the system, as well as overall acceptance. The Next Generation Lighting Systems (NGLS) program began an evaluation of the wall controls in 14 connected lighting systems installed in various rooms of the NGLS Living Lab at Parsons School of Design in New York City. These systems demonstrate the wide range of approaches to wall control setup and functionality taken by manufacturers. Characterizing the 14 controls across six attributes, only four, or 29%, were identical. Requirements for wall control design were not specified explicitly by NGLS. Rather, wall controls were required to provide system performance according to three criteria: vacancy control (manual on/auto off) of two zones; manual continuous dimming of the same two zones; and an AV presentation mode in one of the two zones. This report examines the classification of entries, the assessment method used to evaluate the systems from installation through day-to-day use, and the system performance observed to date for each.

42 ENGINEERING↗

Spinning Reserve From Hotel Load Response: Initial Progress

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Magnetic nanoparticles for applications in oscillating magnetic field

Enzymatic and thermochemical catalysis are both important industrial processes. However, the thermal requirements for each process often render them mutually exclusive: thermochemical catalysis requires high temperature that denatures enzymes. One of the long-term goals of this project is to design a thermocatalytic system that could be used with enzymatic systems in situ to catalyze reaction sequences in one pot; this system would be useful for numerous applications e.g. conversion of biomass to biofuel and other commodity products. The desired thermocatalytic system would need to supply enough thermal energy to catalyze thermochemical reactions, while keeping the enzymes from high temperature denaturation. Magnetic nanoparticles are known to generate heat in an oscillating magnetic field through mechanisms including hysteresis and relaxational losses. We envisioned using these magnetic nanoparticles as the local heat source embedded in sub-micron size mesoporous support to spatially separate the particles from the enzymes. In this study, we set out to find the magnetic materials and instrumental conditions that are sufficient for this purpose. Magnetite was chosen as the first model magnetic material in this study because of its high magnetization values, synthetic control over particle size, shape, functionalization and proven biocompatibility. Our experimental designs were guided by a series of theoretical calculations, which provided clues to the effects of particle size, size distribution, magnetic field, frequency and reaction medium. Materials of theoretically optimal size were synthesized, functionalized, and their effects in the oscillating magnetic field were subsequently investigated. Under our conditions, the materials that clustered e.g. silica-coated and PNIPAM-coated iron oxides exhibited the highest heat generation, while iron oxides embedded in MSNs and mesoporous iron oxides exhibited the least bulk heating. It is worth noting that the specific loss power of PNIPAM-coated Fe 3 O 4 was peculiarly high, and the heat loss mechanism of this material remains to be elucidated. Since thermocatalysis is a long-term goal of this project, we also investigated the effects of the oscillating magnetic field system for the synthesis of 7-hydroxycoumarin-3-carboxylic acid. Application of an oscillating magnetic field in the presence of magnetic particles with high thermal response was found to effectively increase the reaction rate of the uncatalyzed synthesis of the coumarin derivative compared to the room temperature control.

09 BIOMASS FUELS↗

Analysis of human performance differences between students and operators when using the Rancor Microworld simulator

Here, from within the umbrella of the Simplified Human Error Experimental Program (SHEEP) framework, this paper analyzes human performance differences between professional and student operators when using a simplified simulator (i.e., Rancor Microworld). This paper represents a crucial step in understanding the fidelity of the simplified simulators and student operators within the SHEEP study. This paper explores a randomized factorial experimental design that features two independent variables: participant type and event class. Six human performance measurements are considered in the experiment. The experiment is conducted using 20 professional reactor operators employed at actual nuclear power plants (NPPs), along with 20 trained students. The experimental data are analyzed via statistical analysis methods. Finally, this paper examines the differences in human performance between actual operators and students when using Rancor Microworld.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hyperoxia-mediated transcriptional activation of cytochrome P4501A1 (CYP1A1) and decreased susceptibility to oxygen-mediated lung injury in newborn mice

Highlights: • Hyperoxia causes enhanced transcriptional activation of human CYP1A1-Luciferase expression in newborn mice in vivo. • Transgenic mice carrying the human CYP1A1-luc promoter are less susceptible to hyperoxic lung in injury and in vivo. • CYP1A1-Luc mice display increased levels of endogenous hepatic and pulmonary CYP1A as well as NADP(H) quinone oxidoreductase (NQO1) expression after hyperoxia exposure, compared to wild type mice. • The increased endogenous expression of CYP1A1 and NQO1 contributes to the beneficial effects seens in CYP1A1-Luc mice. Hyperoxia contributes to the development of bronchopulmonary dysplasia (BPD) in premature infants. In this study, we tested the hypothesis that newborn transgenic mice carrying the human CYP1A1-Luc promoter will display transcriptional activation of the human CYP1A1 promoter in vivo upon exposure to hyperoxia, and that these mice will be less susceptible to hyperoxic lung injury and alveolar simplification than similarly exposed wild type (WT) mice. Newborn WT (CD-1) or transgenic mice carrying a 13.2 kb human CYP1A1 promoter and the luciferase (Luc) reporter gene (CYP1A1-luc) were maintained in room air or exposed to hyperoxia (85% O{sub 2}) for 7–14 days. Hyperoxia exposure of CYP1A1-Luc mice for 7 and 14 days resulted in 4- and 30-fold increases, respectively, in hepatic Luc (CYP1A1) expression, compared to room air controls. In lung, hyperoxia caused a 2-fold induction of reporter Luc at 7 days, but the induction declined after 14 days. The newborn CYP1A1-Luc mice were less susceptible to lung injury and alveolar simplification than similarly exposed wild type (WT) CD-1 mice. Also, the CYP1A1-Luc mice showed increased levels of hepatic and pulmonary CYP1A1 expression and hepatic CYP1A2 activity after hyperoxia exposure. Hyperoxia also increased NADP(H) quinone reductase (NQO1) pulmonary gene expression in both CD-1 and CYP1A1-Luc mice at both time points, but this was more pronounced in the latter at 14 days. Our results support the hypothesis that hyperoxia activates the human CYP1A1 promoter in newborn mice, and that increased endogenous expression of CYP1A1 and NADP(H) quinone reductase (NQO1) contributes to the decreased susceptibilities to hyperoxic lung injury in the transgenic animals. This is the first report providing evidence of hyperoxia-mediated transcriptional activation of the human CYP1A1 promoter in newborn mice, and this in conjunction with decreased lung injury, suggests that these phenomena have important implications for BPD.

60 APPLIED LIFE SCIENCES↗

A framework to collect human reliability analysis data for nuclear power plants using a simplified simulator and student operators

Data scarcity in human reliability analysis (HRA) has been a major challenge in the quantification process. Many institutes have collected HRA data through experiments using full-scope simulators with actual operators. Nevertheless, there are still some limitations to relying solely on full-scope studies. This paper aims to propose how full-scope data collection studies can be supported through the Simplified Human Error Experimental Program (SHEEP). The SHEEP framework was developed by Idaho National Laboratory (INL) to collect HRA data through a simplified simulator and student operators. This paper introduces the major tasks in the SHEEP framework, with a particular focus on differences that arise due to participant type (i.e., student vs. actual operator), based on experiments using a simplified simulator (i.e., the Rancor Microworld). This paper also describes whether the data collected via this approach could support a representative full-scope data collection study (i.e., the HuREX study) based on the experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗