At least 469 records · Page 26

Characterization of MC&A for the Molten Salt Fuel Cycle

Advanced reactor developers are exploring diverse reactor designs, including molten salt reactors (MSRs). These advanced reactors are considered for wider applications and a range of deployment locations, including supporting the integration of renewable energy sources in the grid. There are three main types of MSRs: (1) reactors in which the fuel salt freely circulates within the core; (2) reactors with the fuel salt contained within vented fuel tubes; and (3) reactors that use molten salt solely as a coolant, with the fuel in a separate, solid form. In this document, the term MSR refers specifically to the first two types, which use fuel salt—special nuclear material (enriched uranium, plutonium, and 233 U) in chloride or fluoride form mixed with chloride- or fluoride-based carrier salt in a peritectic mixture—as the primary medium for fission. The composition of fuel salt, both at startup and for makeup or refueling, varies depending on the MSR design and the chosen fuel cycle approach, which can be either once-through or closed. For MSRs, a variety of fuel cycle approaches (e.g., U, U–Pu, U–Pu–TRU, U–Th, U–Pu–Th) are being considered. Fuel in MSRs is much different than traditional solid fuel, including its preparation. The uniqueness warrants investigation into characterizing fuel preparation processes, known as fuel salt synthesis . This effort characterized major fuel preparation and synthesis processes, identifying temperature, equipment, and environmental requirements for uranium-, plutonium-, and thorium-based fuel preparation and synthesis. Because MSR fuel salt synthesis facilities handle special nuclear material in loose, bulk form, a material control and accounting plan will be required for licensing from the US Nuclear Regulatory Commission or under the US Department of Energy authorization. This effort serves as a foundation to investigate material control and accounting approaches for synthesis facilities, including determining measurement points and techniques. Because several MSR developers are planning demonstration facilities in the coming years, this effort will support stakeholders with preparing or reviewing material control and accounting plans for providing assurance that all special nuclear material is accounted for at fuel salt synthesis facilities. This report was produced for Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy (DOE), Office of Nuclear Energy, Nuclear Fuel Cycle and Supply Chain.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low-Temperature Annealing of CdZnTeSe under Bias

We performed a gradual low-temperature annealing up to 360 K on a CdZnTeSe radiation detector equipped with gold and indium electrodes under bias at both polarities. We observed significant changes in the detector’s resistance and space-charge accumulation. This could potentially lead to the control and improvement of the electronic properties of the detector because the changes are accompanied with the reduction in the bulk dark current and surface leakage current. In this article, we present the results of a detailed study of the internal electric field and conductivity changes in CdZnTeSe detector for various annealing steps under bias taking into account different polarities during annealing and subsequent characterization. We observed that low-temperature annealing results in an increase in the barrier height at the contacts that, in general, reduces the dark current and decreases the positive space charge present in the sample compared to the pre-annealed condition.

47 OTHER INSTRUMENTATION↗

Lawrence Berkley National Laboratory Building 59

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution

The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.

Counterfeit refrigerants↗

Cybersecurity for Electric Vehicle Fast-Charging Infrastructure

The integration of electric vehicles (EVs) into electric grid operations can potentially leave the grid vulnerable to cyberattacks from both legacy and new equipment and protocols, including extreme fast-charging infrastructure. This paper introduces a co-simulation platform to perform cyber vulnerability analysis of EV charging infrastructure and its dependencies on communications and control systems. Grid impact scenarios through linkages to power system simulation tools such as OpenDSS and vehicle infrastructure-specific attack paths are discussed. An adaptive platform that assists with predicting and solving evolving cybersecurity challenges is demonstrated with a cyber-energy emulation that accelerates the analysis of cyberattacks and system behavior.

47 OTHER INSTRUMENTATION↗

Mitigation of Beam Losses in LANSCE Linear Accelerator

Suppression of beam losses is essential for successful operation of high-intensity accelerator facility. The LANSCE accelerator started routine operation in 1972 as a 0.8 MW average proton beam power facility for meson physics research, and delivered highpower beam for a quarter century. The accelerator currently delivers 100 MeV proton beam to Isotope Production Facility (IPF) and 800 MeV H- beams to various experimental areas. The accelerator is equipped with two independent injectors for H + and H - beams, merging at the entrance of a 201.25 MHz Drift Tube Linac (DTL). The DTL performs acceleration up to the energy of 100 MeV. After the DTL, the Transition Region beamline directs a 100 MeV proton beam to the Isotope Production Facility, while the H - beam is accelerated up to the final energy of 800 MeV in an 805- MHz Coupled Cavity Linac. The H - beams, created with different time structure by a lowenergy chopper, are distributed in the Switch Yard (SY) to four experimental areas: the Lujan Neutron Scattering Center equipped with a Proton Storage Ring (PSR), the Weapons Neutron Research facility (WNR), the Proton Radiography facility (pRad), and the Ultra-Cold Neutron facility (UCN). Multi-beam operation requires careful control of accelerator tune to minimize beam losses. In this paper we review main effects affecting beam losses in LANSCE linear accelerator and discuss methods to reduce them.

43 PARTICLE ACCELERATORS↗

CIRCLES: Congestion Impacts Reduction via CAV-in-the-loop Lagrangian Energy Smoothing

The energy efficiency of today’s vehicular mobility relies on the un-integrated combination of i) control via static assets (traffic lights, metering, variable speed limits, etc.); and ii) onboard vehicle automation (adaptive cruise control (ACC), ecodriving, etc.). These two families of control were not co-designed and are not engineered to work in coordination. Recent studies have shown i) limitations of controls, and even ii) negative impacts of ACC. This project focused on the technology development, implementation and prototyping, and validation of Mobile Traffic Control (MTC). MTC can be viewed as an extension of classical traffic control (in which static infrastructure actuates traffic flow). In the MTC paradigm, automated vehicles actuate the entire flow via their behavior, offering enhanced possibilities to optimize the energy footprint of traffic, if designed correctly. We set out to demonstrate for the first time that considerably reduced fuel consumption of all vehicles in traffic can be achieved via distributed control of a small proportion of CAVs. Compared to baseline vehicular technologies, our work offers a significant design departure: control algorithms for the CAVs consider the impact one vehicle can have on overall traffic, improving resulting overall fuel consumption. We focus on using a few vehicles (as traffic controllers via CAV technology) to improve the energy efficiency of traffic flow to further optimize energy efficiency. A live-traffic demonstration in November 2022 featured the deployment of 100 specially-equipped CAVs, constituting an approximate local penetration rate upwards of 2%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity for Electric Vehicle Fast-Charging Infrastructure: Preprint

The integration of electric vehicles (EVs) into electric grid operations can potentially leave the grid vulnerable to cyberattacks from both legacy and new equipment and protocols, including extreme fast-charging infrastructure. This paper introduces a co-simulation platform to perform cyber vulnerability analysis of EV charging infrastructure and its dependencies on communications and control systems. Grid impact scenarios through linkages to power system simulation tools such as OpenDSS and vehicle infrastructure-specific attack paths are discussed. An adaptive platform that assists with predicting and solving evolving cybersecurity challenges is demonstrated with a cyber-energy emulation that accelerates the analysis of cyberattacks and system behavior.

47 OTHER INSTRUMENTATION↗

Cybersecurity for Fast Charging EV Infrastructure

The integration of electric vehicles (EVs) into electric grid operations can potentially leave the grid vulnerable to cyberattacks from both legacy and new equipment and protocols, including extreme fast-charging infrastructure. This paper introduces a co-simulation platform to perform cyber vulnerability analysis of EV charging infrastructure and its dependencies on communications and control systems. Grid impact scenarios through linkages to power system simulation tools such as OpenDSS and vehicle infrastructure-specific attack paths are discussed. An adaptive platform that assists with predicting and solving evolving cybersecurity challenges is demonstrated with a cyber-energy emulation that accelerates the analysis of cyberattacks and system behavior.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Democratized Control Architecture for Regional Transmission Operators

As probably the most complicated and critical infrastructure system, U.S. power grids become increasingly vulnerable to extreme events such as cyber-attacks and severe weather, as well as higher DER penetrations and growing information mismatch among system operators, utilities (transmission or generation owners), and end-users. This paper proposes a data-driven democratized control architecture considering two democratization pathways to assist transmission system operators, with a targeted use case of developing online proactive islanding strategies. Detailed discussions on load capability profiling at transmission buses and disaggregation of DER generations are provided and illustrated with real-world utility data. By Combining network and operational constraints, transmission system operators can be equipped with new tools built on top of this architecture, to derive accurate, proactive, and strategic islanding decisions to incorporate the wide range of dynamic portfolios and needs when facing extreme events or unseen grid contingencies.

Power System Reliability, Islanding, Democratized ↗

FARM supervisory capabilities for thermal energy storage

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, an overview of the major capabilities of the latest release of FARM is provided, along with a summary of the tool demonstration campaign conducted at the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility. These results assess the performance of the control system architecture embedding FARM both as a Validator of the HERON power dispatcher and as a real time Supervisory control scheme. Additionally, the report outlines the areas that FARM might benefit from, along with proposed solutions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application

As an environmentally friendly low global warming potential (GWP) refrigerant, Carbon dioxide (CO 2 ) has continuously gained popularity and research attention as alternative refrigerant for supermarket refrigeration system. In this paper, to fulfill the increasing need of accurate Low-GWP supermarket refrigeration models for development of supervisory level control and optimization strategies, a high fidelity model is developed for CO 2 transcritical supermarket refrigeration system which includes compressor rack of low temperature (LT) compressors and medium temperature (MT) compressors, air-cooled gas cooler, evaporator, expansion valves and other auxiliary equipment. A resistance-capacity model structure is proposed to simulate the display cases. Semi-thermodynamic models are proposed to estimate reciprocating compressors volumetric efficiency and power consumption. Furthermore the zone modeling approach is used for evaporator simulation, and air-cooled gas cooler is modeled with distributed modeling method. The expansion valve simulation is based on orifice flow model. To calibrate these models, both manufacture performance data and experimental data are used. The experiments are conducted with a full instrumental CO 2 supermarket refrigeration system installed in Oak Ridge National Lab Flexible Research Platform (FRP). The simulation model can predict the system performance, including power consumption, cooling capacity, mass flow rate, temperature, and pressure, with high accuracy (within ±4%) compared to experimental data. In addition, this developed model has been used to create the system optimum high side pressure for high side expansion valve control, and to generate wide operating range simulation data for developing the batter-equivalent commercial refrigeration system model which can be used in grid interactive control development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic NMPC for a Reversible Solid Oxide Cell

Reversible solid oxide fuel cells (rSOCs) offer the flexibility to operate in tandem with the electric grid by switching between fuel cell and electrolysis modes based on real-time electricity prices. However, their complex, tightly coupled dynamic behavior poses significant challenges in determining optimal operating strategies. In this work, we present an economic nonlinear model predictive control (E-NMPC) framework to optimize the operation of rSOCs. The proposed E-NMPC is applied to a detailed rSOC flowsheet model that includes a utility scale rSOC module as well as balance-of-plant equipment necessary for thermal management. Our results demonstrate that in fuel cell mode, the E-NMPC strategy reduces hydrogen consumption compared to conventional set-point tracking NMPC, while maintaining the same level of electricity output. Also, in electrolysis mode, the E-NMPC yields a marginal improvement in hydrogen production. In addition, we explore the integration of a battery with the rSOC system to enhance flexibility in meeting electricity production and consumption targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electric Vehicles Charging Time Constrained Deliverable Provision of Secondary Frequency Regulation

Aggregation of electric vehicles (EVs) is a promising technique for providing secondary frequency regulation (SFR) in highly renewable energy-penetrated power systems. Equipped with energy storage devices, EV aggregation can provide reliable SFR. However, the main challenge is to guarantee reliable intra-interval SFR capacities and inter-interval delivery following the automatic generation control (AGC) signal. Furthermore, aggregated EV SFR provision will be further complicated by the EV charging time anxiety because SFR provision might extend EV's charging time. This paper proposes a deliverable EV SFR provision with a charging-time-constrained control strategy. First, a charging-time-constrained EV aggregation is proposed to address the uncertainty of EV capacity based on the state-space model considering the charging-time restriction of EV owners. Second, a real-time economic dispatch and time domain simulation (RTED-TDS) cosimulation framework is proposed to verify financial results and the dynamic performance of the EV SFR provision. Last, the proposed charging time-constrained EV aggregation is validated on the IEEE 39-bus system. In conclusion, the results demonstrate that with charging time-constrained EV aggregation, the dynamic performance of the system can be improved with a marginal increase in total cost. More importantly, the charging time constraint can be respected in the proposed SFR provision of the EV aggregation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extreme Miller cycle with high intake boost for improved efficiency and emissions in heavy-duty diesel engines

This study experimentally investigates the impact of extreme Miller cycle strategies paired with high intake manifold pressures on the combustion process, emissions, and thermal efficiency of heavy-duty diesel engines. Well-controlled experiments isolating the effect of Miller cycle strategies on the combustion process were conducted at constant engine speed and load (1160 rpm, 1.76 MPa net IMEP) on a single cylinder research engine equipped with a fully-flexible hydraulic valve train system. Late intake valve closing (LIVC) timing strategies were compared to a conventional intake valve profile under either constant cylinder composition, constant engine-out NO x emission, or constant overall turbocharger efficiency (η TC ) to investigate the operating constraints that favor Miller cycle operation over the baseline strategy. Furthermore, utilizing high boost with conventional intake valve closing timing resulted in improved fuel consumption at the expense of sharp increases in peak cylinder pressures, engine-out NO x emissions, and reduced exhaust temperatures. Miller cycle without EGR at constant λ demonstrated LIVC strategies effectively reduce engine-out NO x emissions by up to 35%. However, Miller cycle associated with very aggressive LIVC timings led to fuel consumption penalties due to increased pumping work and exhaust enthalpy. LIVC strategies allowed for increased charge dilution at the baseline NO x constraint of 3.2 g/kWh, resulting in significant fuel consumption benefits over the baseline case without compromising exhaust temperatures or peak cylinder pressures. As Miller cycle implementation was shown to affect the boundary conditions dictating η TC , the LIVC and conventional IVC cases were studied at an equivalent η TC point representative of high boost operation. With high boost, LIVC yielded reduced NO x emissions, reduced peak cylinder pressures, and elevated exhaust temperatures compared to the conventional IVC case without compromising fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtualizing Industrial Control Networks for Cyber Resilience Experiments

Industrial control systems (ICS) networks are undergoing constant shifts to accommodate new security measures. It is challenging to test varying network configurations and security tools with physical systems as they typically include large, expensive equipment. Not only this, but researchers often do not have access to this type of equipment for development of new security tools and techniques. As a solution to these issues, this work presents a set of tools for utilizing GNS3 and Docker as a virtual ICS network. Additionally, the virtual network can be attached to physical devices including network switches, hardware simulations, and intelligent electronic devices (IEDs). Two case studies showcase a relatively complex automatically generated network and an attack on a simple ICS network with an example mitigation.

42 ENGINEERING↗