Search NASA⌕ Search

SEARCH · Search NASA

Results for “DATA READOUT SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Design of a new Nd:YAG Thomson scattering system for MAST

A new infrared Thomson scattering system has been designed for the MAST tokamak. The system will measure at 120 spatial points with {approx_equal}10 mm resolution across the plasma. Eight 30 Hz 1.6 J Nd:YAG lasers will be combined to produce a sampling rate of 240 Hz. The lasers will follow separate parallel beam paths to the MAST vessel. Scattered light will be collected at approximately f/6 over scattering angles ranging from 80 deg. to 120 deg. The laser energy and lens size, relative to an existing 1.2 J f/12 system, greatly increases the number of scattered photons collected per unit length of laser beam. This is the third generation of this polychromator to be built and a number of modifications have been made to facilitate mass production and to improve performance. Detected scattered signals will be digitized at a rate of 1 GS/s by 8 bit analog to digital converters (ADCs.) Data may be read out from the ADCs between laser pulses to allow for real-time analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results in Studying the Readout Electronics of the Silicon Tracking System for Upgrading the CLAS12 Experiment

Investigations of the readout electronics for the tracking system of the CLAS12 experiment have been performed for the last 2 years. The setup and physical problems of the CLAS12 experiment are described. The silicon detectors designed by the authors for the tracking system of the experiment are considered in brief. The electronic system contains the silicon microstrip detector and FSSR2 integrated circuit, which reads signals from the detector. The FSSR2 chip is described and the principles of the chip architecture intended for processing a time-variable data flow and experimental characteristics obtained on trials of the chip are set forth in brief. Results of simulating the chip throughput under loads expected for the physical experiment and experimental characteristics obtained on trials of this chip are described.

42 ENGINEERING↗

DISCOVERY OF FINELY STRUCTURED DYNAMIC SOLAR CORONA OBSERVED IN THE Hi-C TELESCOPE

In the Summer of 2012, the High-resolution Coronal Imager (Hi-C) flew on board a NASA sounding rocket and collected the highest spatial resolution images ever obtained of the solar corona. One of the goals of the Hi-C flight was to characterize the substructure of the solar corona. We therefore examine how the intensity scales from AIA resolution to Hi-C resolution. For each low-resolution pixel, we calculate the standard deviation in the contributing high-resolution pixel intensities and compare that to the expected standard deviation calculated from the noise. If these numbers are approximately equal, the corona can be assumed to be smoothly varying, i.e., have no evidence of substructure in the Hi-C image to within Hi-C's ability to measure it given its throughput and readout noise. A standard deviation much larger than the noise value indicates the presence of substructure. We calculate these values for each low-resolution pixel for each frame of the Hi-C data. On average, 70% of the pixels in each Hi-C image show no evidence of substructure. The locations where substructure is prevalent is in the moss regions and in regions of sheared magnetic field. We also find that the level of substructure varies significantly over the roughly 160 s of the Hi-C data analyzed here. This result indicates that the finely structured corona is concentrated in regions of heating and is highly time dependent.

79 ASTRONOMY AND ASTROPHYSICS↗

Firmware development for the ATLAS TileCal sROD

TileCal is the central hadronic calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. A main upgrade of the LHC (also called Phase-II) is planned in order to increase the instantaneous luminosity in 2022. At the TileCal level, the upgrade involves the redesign of the complete read-out architecture, affecting both the front-end and the back-end electronics. In the new read-out architecture, the front-end electronics will transmit digitized information of the full detector to the back-end system every single bunch crossing. Thus, the back-end system must provide digital calibrated information to the first level of trigger. Having all detector data per bunch crossing in the back-end will increase the precision and granularity of the trigger information, improving this way the trigger efficiencies. A reduced part of the detector, 1/256 of the total, will be equipped with the new electronics during 2014 to evaluate the proposed architecture in real conditions in the so-called 'demonstrator project'. The upgraded version of the Read-Out Driver (sROD) will be the core element of the back-end electronics in Phase-II. The sROD demonstrator is a prototype that is being developed to validate in the demonstrator project the future sROD for Phase-II. This module includes two Xilinx Series 7 Field Programmable Gate Arrays (FPGAs) for data receiving and processing and will be installed and working in an ATCA framework. A complete description of the sROD functionality in terms of firmware will be introduced. In addition, the status of the firmware development and a summary of the main milestones achieved and the future plans will be presented. (authors)

43 PARTICLE ACCELERATORS↗

Outrunning free radicals in room-temperature macromolecular crystallography

A systematic increase in lifetime is observed in room-temperature protein and virus crystals through the use of reduced exposure times and a fast detector. A significant increase in the lifetime of room-temperature macromolecular crystals is reported through the use of a high-brilliance X-ray beam, reduced exposure times and a fast-readout detector. This is attributed to the ability to collect diffraction data before hydroxyl radicals can propagate through the crystal, fatally disrupting the lattice. Hydroxyl radicals are shown to be trapped in amorphous solutions at 100 K. The trend in crystal lifetime was observed in crystals of a soluble protein (immunoglobulin γ Fc receptor IIIa), a virus (bovine enterovirus serotype 2) and a membrane protein (human A{sub 2A} adenosine G-protein coupled receptor). The observation of a similar effect in all three systems provides clear evidence for a common optimal strategy for room-temperature data collection and will inform the design of future synchrotron beamlines and detectors for macromolecular crystallography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE{sup Registered-Sign} radiochromic plastic

Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE{sup Registered-Sign} with optical-CT readout. Methods: Ge-doped SiO{sub 2} fibers with 6 {mu}m active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 {mu}m active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE{sup Registered-Sign }, 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE{sup Registered-Sign }, and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for fibers, 3-50 mm for EBT3, and 4-21 mm for PRESAGE{sup Registered-Sign }. Fibers demonstrated some over-response at very low dose levels, suffered from volume averaging effects in the dose distribution measurement, and exhibited up to 9% repeatability variation over three repeated measurements. EBT3 demonstrated excellent agreement with Monte Carlo and TPS dose distributions, with up to 3% repeatability over three measurements. PRESAGE{sup Registered-Sign} gave promising results, being the only true 3D dosimeter, but artifacts and noise were apparent. Conclusions: The comparative response of three emerging dosimetry systems for clinical brachytherapy dose distribution measurement has been investigated. Ge-doped optical fibers have excellent spatial resolution for single-direction measurement but are currently too large for complex dose distribution assessment. The use of PRESAGE{sup Registered-Sign} with optical-CT readout gave promising results in the measurement of true 3D dose distributions but further development work is required to reduce noise and improve dynamic range for brachytherapy dose distribution measurements. EBT3 Gafchromic film with multichannel analysis demonstrated accurate and reproducible measurement of dose distributions in HDR brachytherapy. Calibrated dose measurements were possible with agreement within 1.5% of TPS dose calculations. The suitability of EBT3 as a dosimeter for 2D quality control or commissioning work has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Research relative to the heavy isotope spectrometer telescope experiment

The Heavy Isotope Spectrometer Telescope (HIST) was launched during August 1978 on ISEE-3 (ICE). HIST was designed to measure the isotopic composition of solar, galactic, and interplanetary cosmic ray nuclei for the elements from H to Ni (1 less than or equal to Z less than or equal to 28) in the energy range from approximately 5 to approximately 200 MeV/nucleon. The results of these measurements have been used in studies of the composition of solar matter and galactic cosmic ray sources, the study of nucleosynthesis processes, studies of particle acceleration and propagation, and studies of the life-history of cosmic rays in the heliosphere and in the galaxy. On December 1, 1978, after 110 days in orbit, HIST suffered an electronic failure in its readout system. After that point, only one-half of the telemetry bits associated with the pulse heights measured by HIST were transmitted to Earth. As a result, the resolution of HIST was significantly degraded, and it served as an element rather than an isotope spectrometer. Fortunately, HIST was able to measure the isotopic composition of heavy nuclei in the 9/23/78 solar event (the largest solar energetic particle event since 1972) during the brief period that it operated at full resolution. This grant funded the analysis of data from the HIST instrument over the period from 12/1/85 to 11/30/92. In section 2 of this final report, we summarize the scientific accomplishments that have resulted from HIST measurements during this time period. A bibliography of tasks and papers that resulted is attached.

Stone, Edward C.↗

Electronic Ambient-Temperature Recorder

Electronic temperature-recording unit stores data in internal memory for later readout. Records temperatures from minus 40 degrees to plus 60 degrees C at intervals ranging from 1.875 to 15 minutes. With all four data channels operating at 1.875-minute intervals, recorder stores at least 10 days' data. For only one channel at 15-minute intervals, capacity extends to up to 342 days' data. Developed for recording temperatures of instruments and life-science experiments on satellites, space shuttle, and high-altitude aircraft. Adaptable to such terrestrial uses as recording temperatures of perishable goods during transportation and of other systems or processes over long times. Can be placed directly in environment to monitor.

Russell, Larry↗

The CLAS12 Forward Time-of-Flight system

The Forward Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system is positioned at distances in the range from 6.2 m to 7.2 m from the beam–target interaction point and spans laboratory polar angles from 5 deg → 45 deg and nearly the full azimuth. The system consists of 540 individual scintillation counters with double-ended readout that range in length from 17 cm to 426 cm of discrete widths of 6 cm, 15 cm, and 22 cm, and of discrete thicknesses of 5 cm and 6 cm. We see the effective counter time resolution for passing charged particles varies from 50 ps for the shortest counters at small angles to 200 ps for the longest counters at large angles. The detectors are part of the forward-angle particle identification system for CLAS12 during offline event reconstruction and are a component of the online data acquisition trigger to select final state event topologies with forward-going charged particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operationally induced preferred basis in unitary quantum mechanics

The preferred-basis problem and the definite-outcome aspect of the measurement problem persist even if the detector is modeled unitarily, because experimental data are necessarily represented in a Boolean event algebra of mutually exclusive records whereas the theoretical description is naturally formulated in a noncommutative operator algebra with continuous unitary symmetry. This change of mathematical type constitutes the core of the 'cut': a structurally necessary interface from group-based kinematics to set-based counting. In the presented view the basis relevant for recorded outcomes is not determined by the system Hamiltonian alone; it is induced by the measurement mapping, i.e., by the detector channel together with the coarse-grained readout that defines an instrument. The probabilistic mapping is anchored in symmetry and measure theory: by Gleason-type uniqueness (Gleason for projections in $d>2$ and Busch's extension for Positive Operator-Valued Measures (POVMs) including $d=2$), the trace rule is the unique probability measure consistent with additivity over exclusive events and basis-independence of the unitary sector. A compact qubit--pointer model yields an induced unsharp POVM $E_\pm=\tfrac12(\id\pm η\,σ_z)$ with $η$ fixed by pointer resolution, displaying explicitly how the detector induces the relevant basis. Finally, nested-observer paradoxes are tightened into a non-composability lemma: joint assignment of outcome propositions is obstructed unless a joint instrument exists. This relocates the origin of randomness to the stochasticity of the transition rules.

Pronskikh, Vitaly [Fermilab] (ORCID:00000002518174↗

The Drift Chamber for the Experiment to Study the Nature of the Confinement

The GlueX experiment was designed to search for hybrid mesons with exotic quantum numbers using a beam of linearly polarized photons incident on a liquid hydrogen target. The spectrum of these states and their mass splitting from normal mesons may yield information on confinement. The description of the GlueX spectrometer and Forward Drift Chambers (FDC) as a part of track reconstruction system is presented in the text. FDC‘s are multiwire chambers with cathode and anode read-out. The system allows reconstructing tracks of charged particles with ~200mkm accuracy with angles from 20° up to 1°. One of the detector features is 1.64% X 0 material amount in the active area. The cathode gain calibration procedure is presented. The results of such calibration using cosmic data and beam data are presented as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

Using pile-up collisions as an abundant source of low-energy hadronic physics processes in ATLAS and an extraction of the jet energy resolution

During the 2015–2018 data-taking period, the Large Hadron Collider delivered proton-proton bunch crossings at a centre-of-mass energy of 13 TeV to the ATLAS experiment at a rate of roughly 30 MHz, where each bunch crossing contained an average of 34 independent inelastic proton-proton collisions. The ATLAS trigger system selected roughly 1 kHz of these bunch crossings to be recorded to disk. Offline algorithms then identify one of the recorded collisions as the collision of interest for subsequent data analysis, and the remaining collisions are referred to as pile-up. Pile-up collisions represent a trigger-unbiased dataset, which is evaluated to have an integrated luminosity of 1.33 pb -1 in 2015–2018. This is small compared with the normal trigger-based ATLAS dataset, but when combined with vertex-by-vertex jet reconstruction it provides up to 50 times more dijet events than the conventional single-jet-trigger-based approach, and does so without adding any additional cost or requirements on the trigger system, readout, or storage. The pile-up dataset is validated through comparisons with a special trigger-unbiased dataset recorded by ATLAS, and its utility is demonstrated by means of a measurement of the jet energy resolution in dijet events, where the statistical uncertainty is significantly reduced for jet transverse momenta below 65 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of the Generic Electronics for Time Projection Chamber ($\mathrm{GET}$) readout system for heavy Radioactive isotope collision experiments

Here we have implemented the Generic Electronics for Time Projection Chamber (GET) in a SAMURAI Pion Reconstruction and Ion-Tracker (SπRIT) readout system for heavy radioactive ion collision experiments at RIKEN-RIBF. The SπRIT experiment is designed for heavy ion collision experiments with radioactive ion beams, where a Time Projection Chamber (TPC) with 12096 pixelized readout pads is employed as the main device. Since the TPC is located on the beam line, the readout electronics must handle small signals from pions as well as very large signals from beam or large fragment particles. Operation of the GET electronics during experiment functioned well using 270 time-bucket readout with 25 MHz sampling at an event Data acquisition (DAQ) rate of 60 Hz. Using the slope information of acquired signals it is possible to extend the dynamic range of dE/dx information compared to using the peak height information. However, huge signals arising from energetic δ-rays produced by un-interacted projectiles induce dead channels, which can be recovered after 70 μs on average.

47 OTHER INSTRUMENTATION↗

The Nimbus F Random Access Measurement System /RAMS/

In 1974, the Random Access Measurement System (RAMS) will be launched aboard the Nimbus F satellite as part of the Tropical Wind, Energy Conversion, and Reference Level Experiment (TWERLE). This paper describes operation and performance of the RAMS instrument, which will provide a means of tracking and collecting data from a large number of instrumented platforms. In operation, the RAMS will perform satellite onboard processing of up to eight simultaneous platform transmissions, following search and detection of the randomly received platform transmissions in a compressed-time expanded-frequency domain. The processed data is stored aboard the satellite for readout every 108 minutes (orbital period), and platform locational coordinates and/or velocity components are determined in a central ground data processing facility.

Coates, J. L.↗

Characterisation and testing of CHEC-M—A camera prototype for the small-sized telescopes of the Cherenkov telescope array

The Compact High Energy Camera (CHEC) is a camera design for the Small-Sized Telescopes (SSTs; 4 m diameter mirror) of the Cherenkov Telescope Array (CTA). The SSTs are focused on very-high-energy γ-ray detection via atmospheric Cherenkov light detection over a very large area. This implies many individual units and hence cost-effective implementation, as well as shower detection at large impact distance, and hence large field of view (FoV), and efficient image capture in the presence of large time gradients in the shower image detected by the camera. CHEC relies on dual-mirror optics to reduce the plate-scale and make use of 6 x 6 mm 2 pixels, leading to a low-cost (~150 k€), compact (0.5 m x 0.5 m), and light (~45 kg) camera with 2048 pixels providing a camera FoV of ~9 degrees. The CHEC electronics are based on custom TARGET (TeV array readout with GSa/s sampling and event trigger) application-specific integrated circuits (ASICs) and field programmable gate arrays (FPGAs) sampling incoming signals at a gigasample per second, with flexible camera-level triggering within a single backplane FPGA. CHEC is designed to observe in the γ-ray energy range of 1–300 TeV, and at impact distances up to 500 m. To accommodate this and provide full flexibility for later data analysis, full waveforms with 96 samples for all 2048 pixels can be read out at rates up to ~900 Hz. The first prototype, CHEC-M, based on multi-anode photomultipliers (MAPMs) as photosensors, was commissioned and characterised in the laboratory and during two measurement campaigns on a telescope structure at the Paris Observatory in Meudon. Here in this paper, the results and conclusions from the laboratory and on-site testing of CHEC-M are presented. They have provided essential input on the system design and on operational and data analysis procedures for a camera of this type. In conclusion, a second full-camera prototype based on Silicon photomultipliers (SiPMs), addressing the drawbacks of CHEC-M identified during the first prototype phase, has already been built and is currently being commissioned and tested in the laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗

A new ATLAS muon CSC readout system with system on chip technology on ATCA platform

The ATLAS muon Cathode Strip Chamber (CSC) backend readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run-2 luminosity. The readout design is based on the Reconfigurable Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the Advanced Telecommunication Computing Architecture (ATCA) platform. The RCE design is based on the new System on Chip XILINX ZYNQ series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources. Together with auxiliary memories, all of these components form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the ZYNQ for high speed input and output fiberoptic links and TTC allowed the full system of 320 input links from the 32 chambers to be processed by 6 COBs in one ATCA shelf. The full system was installed in September 2014. In conclusion, we will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning for LHC Run 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗