Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

On Developing One-Chip Integration of 1.2 kV SiC MOSFET and JBS Diode (JBSFET)

This paper presents the design, fabrication, and characterization of the SiC JBSFET (JBS diode integrated MOSFET). The fabrication of the JBSFET adopted a novel single metal, single thermal treatment process to simultaneously form ohmic contacts on n+, p+ implanted regions, and Schottky contact on the n- 4H-SiC epi-layer. The presented SiC JBSFET uses 40% smaller wafer area because the diode and MOSFET share the edge termination as well as the current conducting drift region. Here, the proposed single chip solution of MOSFET/JBS diode functionalities eliminates the parasitic inductance between separately packaged devices allowing a higher frequency operation in a power converter.

42 ENGINEERING↗

A Comparison of Ion Implantation at Room Temperature and Heated Ion Implantation on the Body Diode Degradation of Commercial 3.3 kV 4H-SiC Power MOSFETs

It has been demonstrated that basal plane dislocations (BPDs)-induced stacking faults (SFs) cause body diode degradation in commercial 4H-SiC power MOSFETs, especially with higher voltage ratings. BPDs originate from 4H-SiC boule, epi growth, and ion implantation. Considering the lower cost of ion implantation at room temperature (RT), this work investigates the potential of RT ion implantation replacing heated (HT) ion implantation by comparing the influence of both ion implantations on the body diode degradation of commercial 3.3 kV 4H-SiC power MOSFETs. We demonstrate with long-term (up to 1000 hours) forward current stress that RT implantation can keep the body diode degradation of 3.3 kV 4H-SiC power MOSFETs within the specification limits compared with HT implantation.

4H-SiC↗

Performance and reliability of β-Ga 2 O 3 Schottky barrier diodes at high temperature

Beta-gallium oxide (ß-Ga 2 O 3 ) is an ultrawide bandgap semiconductor that has potential for power electronic applications and devices operating at high temperatures. Particularly important for these applications are its 4.9 eV bandgap, facile electron doping, and the ability to grow ß-Ga 2 O 3 crystals from the melt. In this work, vertical ß-Ga 2 O 3 Schottky barrier diodes were fabricated using Pt Schottky and Ti-based Ohmic contacts and Au contact pads on unintentionally doped n-type, (2¯01)-oriented single crystal substrates. The diode’s temperature-dependent electrical properties up to 400°C were investigated, and the Pt/Ga 2 O 3 Schottky barrier height was determined to be close to 1.2 eV. The degradation of the contacts over multiple cycles up to 400°C was observed, resulting in a significant increase in series resistance of the diodes by 1000× at ambient temperature after they were cycled. According to electron microscopy measurements, this degradation is likely due in part to the migration and oxidation of Ti at the top surface of the Au contact pads. This degradation highlights the need for further research and development to ensure stable Ohmic and Schottky contacts to Ga 2 O 3 at temperatures above 400°C.

36 MATERIALS SCIENCE↗

SU-F-J-184: Proton Computed Tomography Using 1D Silicon Diode Array

Purpose: Proton radiography and proton computed tomography (PCT) can be used to measure proton stopping power directly. However, practical and cost effective proton imaging detectors are not widely available. In this study, the authors investigated the feasibility of proton imaging using a silicon diode array. Methods: A one-dimensional silicon-diode detector array (1DSDA) was aligned with the central axis (CAX) of the proton beam. Polymethyl methacrylate (PMMA) slabs were used to find the correspondence between the water equivalent thickness (WET) and 1DSDA channel number. 2D proton radiographs (PR) were obtained by translation and rotation of a phantom relative to CAX while the proton nozzle and 1DSDA were kept stationary. A PCT image of one slice of the phantom was reconstructed using filtered backprojection. Results: PR and PCT images of the PMMA cube were successfully acquired using the 1DSDA. The WET of the phantom was measured using PR data with an accuracy of 4.2% or better. Structures down to 1 mm in size could be resolved. Reconstruction of a PCT image showed very good agreement with simulation. Limitations in spatial resolution are attributed to limited spatial sampling, beam collimation, and proton scatter. Conclusion: The results demonstrate the feasibility of using silicon diode arrays for proton imaging. Such a device can potentially offer fast image acquisition, high spatial and energy resolution for PR and PCT.

60 APPLIED LIFE SCIENCES↗

Leakage currents in 4H-SiC JBS diodes

Leakage currents in high-voltage 4H-SiC diodes, which have an integrated (p-n) Schottky structure (Junction Barrier Schottky, JBS), have been studied using commercial diodes and specially fabricated (based on a commercial epitaxial material) test Schottky diodes with and without the JBS structure. It is shown that (i) the main role in reverse charge transport is played by SiC crystal structure defects, most probably, by threading dislocations (density {approx}10{sup 4} cm{sup -2}), and (ii) the JBS structure, formed by the implantation of boron, partially suppresses the leakage currents (by up to a factor of 10 at optimal separation, 8 {mu}m between local p-type regions).

36 MATERIALS SCIENCE↗

On the radiation resistance of planar Gunn diodes with δ-doped layers

The radiation resistance of planar Gunn diodes is investigated. Based on the results of measurements of the pulsed current–voltage characteristics and computer simulations it is shown that the use of δ layers of doping impurities contributes to the higher radiation resistance of planar diodes by an order of magnitude compared to conventional Gunn diodes. The results of this study make it possible to formulate methodical guidelines to reduce the amount of computational and experimental studies without a considerable decrease in their informativity.

36 MATERIALS SCIENCE↗

Effect of Electron Irradiation with an Energy of 0.9 MeV on the I–V Characteristics and Low-Frequency Noise in 4H–SiC pin Diodes

It is established experimentally that noticeable changes in the I–V characteristics and low-frequency noise in 4H-SiC pin diodes irradiated by electrons with an energy of 0.9 MeV are observed after doses of Φ ≥ 1.4 × 10{sup 15} cm{sup –2}. The currents in the forward and reverse branches of the I–V characteristics vary nonmonotonically at voltages lower than 2 V with increasing dose, which is explained by the interaction between the excited electronic subsystem and metastable defects. In this case, a steady increase in the ideality factor and the series resistance of diodes in the region of exponential growth of the I–V characteristics at voltages exceeding 2 V is observed. The reliable operation of microwave devices with low-noise 4H-SiC pin diodes under conditions of electron irradiation is possible up to a cumulative dose of Φ ≤ 10{sup 15} cm{sup –2}. In microwave devices, the level of low-frequency noise in which is irrelevant but the stabile regime of parameters is of importance, the dose can be increased to Φ ≈ 8 × 10{sup 15} cm{sup –2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring the Electronic Bandgap of Carbon Nanotube Networks in Non-Ideal p-n Diodes

The measurement of the electronic bandgap and exciton binding energy in quasi-one-dimensional materials such as carbon nanotubes is challenging due to many-body effects and strong electron–electron interactions. Unlike bulk semiconductors, where the electronic bandgap is well known, the optical resonance in low-dimensional semiconductors is dominated by excitons, making their electronic bandgap more difficult to measure. In this work, we measure the electronic bandgap of networks of polymer-wrapped semiconducting single-walled carbon nanotubes (s-SWCNTs) using non-ideal p-n diodes. We show that our s-SWCNT networks have a short minority carrier lifetime due to the presence of interface trap states, making the diodes non-ideal. We use the generation and recombination leakage currents from these non-ideal diodes to measure the electronic bandgap and excitonic levels of different polymer-wrapped s-SWCNTs with varying diameters: arc discharge (~1.55 nm), (7,5) (0.83 nm), and (6,5) (0.76 nm). Our values are consistent with theoretical predictions, providing insight into the fundamental properties of networks of s-SWCNTs. The techniques outlined here demonstrate a robust strategy that can be applied to measuring the electronic bandgaps and exciton binding energies of a broad variety of nanoscale and quantum-confined semiconductors, including the most modern nanoscale transistors that rely on nanowire geometries.

36 MATERIALS SCIENCE↗

Charge Collection in Simple EPI Diodes

Charge collection from ion tracks in epi diodes is investigated by computer simulations. As previously noted by others, collected charge can exceed charge liberated in the epi layer. Several cases are compared to illustrate the effect of changing ion LET, epi doping density, and doping types. It is found that the n(sup +)-p-p(sup +) diode displays a funneling regime and a diffusion regime (as previously noted by others),, but the p(sup +)-n-n(sup +) diode does not. Simple models are proposed for quantitative estimates of collected charge. A qualitative two-state picture of funneling is discussed.

epi diodes↗

On the Long-Term Stability of Microwave Radiometers Using Noise Diodes for Calibration

Results are presented from the long-term monitoring and calibration of the National Aeronautics and Space Administration Jason Microwave Radiometer (JMR) on the Jason-1 ocean altimetry satellite and the ground-based Advanced Water Vapor Radiometers (AWVRs) developed for the Cassini Gravity Wave Experiment. Both radiometers retrieve the wet tropospheric path delay (PD) of the atmosphere and use internal noise diodes (NDs) for gain calibration. The JMR is the first radiometer to be flown in space that uses NDs for calibration. External calibration techniques are used to derive a time series of ND brightness for both instruments that is greater than four years. For the JMR, an optimal estimator is used to find the set of calibration coefficients that minimize the root-mean-square difference between the JMR brightness temperatures and the on-Earth hot and cold references. For the AWVR, continuous tip curves are used to derive the ND brightness. For the JMR and AWVR, both of which contain three redundant NDs per channel, it was observed that some NDs were very stable, whereas others experienced jumps and drifts in their effective brightness. Over the four-year time period, the ND stability ranged from 0.2% to 3% among the diodes for both instruments. The presented recalibration methodology demonstrates that long-term calibration stability can be achieved with frequent recalibration of the diodes using external calibration techniques. The JMR PD drift compared to ground truth over the four years since the launch was reduced from 3.9 to - 0.01 mm/year with the recalibrated ND time series. The JMR brightness temperature calibration stability is estimated to be 0.25 K over ten days.

noise diode (ND)↗

Generation of 369.4 nm Radiation by Efficient Doubling of a Diode Laser

The trapped ytterbium ion frequency standard under development at JPL is designed to supply ultra-stable reference signals to be used in spacecraft tests of general relativity and other science experiments. Only diode lasers meet the requirements of low power comsumption and small size for use aboard spacecraft, but diode lasers are not currently available at 369.4 nm wavelength. It is therefore necessary to employ frequency doubling methods to reach this frequency with diode lasers. Here we present the characteristics of the resonant cavity doubling system we have designed and preliminary UV conversion results.

ultra-stable↗

A Nanoscale Vacuum Field Emission Gated Diode with an Umbrella Cathode

A nanoscale field emission vacuum channel gated diode structure is proposed and a tungsten cathode with an umbrella-like geometry and sharp vertical edge is fabricated. The edge of the suspended cathode becomes the field emission surface. Unlike in the traditional transistor with the gate typically located between the source and the drain, the bottom silicon plate becomes the gate here and the anode terminal is located between the umbrella cathode and the gate. The fabricated devices show excellent diode characteristics and the gated diode structure is attractive for extremely low gate leakage.

Vacuum field emission diode↗

X-ray Diode Preparation

A rod pinch x-ray diode assembly culminates in a coaxial anode cathode arrangement where a small anode rod extends through the aperture of a cathode plate. Shotto- shot repeatability in rod placement, and thus x-ray source spot position, has potential to positively affect radiographic image quality. Thus, how to both control and measure, according to a Cartesian coordinate system, anode rod tip displacement (x, y) (off the beam line-of-sight retical) and also anode rod tip extension (z) (along the line-of-sight center line) become salient issues relative to radiographic image set utility. To address these issues both hardware fabrication and x-ray diode assembly methods were reviewed, and additional controls were introduced. A photogrammetric procedure was developed to quantify anode rod tip position in situ. Computer models and mock-up assemblies with precision fiducials were produced to validate this procedure. Therefore, both anode rod tip displacement and anode rod tip extension parameters were successfully controlled. Rod position was measured and met the required specifications: (1) radial displacement <0.25 mm and (2) axial placement of ±0.25 mm. We demonstrated that precision control and measurement of large scale components is achievable in a pulse power system (i.e., hardware and operations). Correlations with diode performance and radiography are presented.

42 ENGINEERING↗

Plasma Measurements in High Intensity Electron Beam Diodes

Experiments are being performed on the Self-Magnetic Pinch (SMP) electron beam diode on the RITS-6 accelerator at Sandia National Laboratories. This diode produces a tightly focused electron beam (< 3mm diameter) which is incident on a high atomic number bremsstrahlung x-ray converter. Typical diode parameters are 120 kA, 7 MeV, and 70ns current pulse, giving a ~45ns x-ray pulse. Plasmas from contaminants on the electrode surfaces propagate into the A-K vacuum gap, affecting the impedance, x-ray spectrum, and pulse width. These plasmas are measured using diagnostics, which include: spectroscopy, optical imaging, and photon detection; to obtain velocity, density, and temperature information. These parameters are measured both spatially, using multi-fiber arrays, and temporally, using streak cameras and avalanche photodiodes. Plasma densities and temperatures are determined from detailed, time-dependent, collisional-radiative (CT) and radiation transport (RT) models, which include Stark broadening of the hydrogen-alpha transition line and carbon ion line ratios. These results are combined with hybrid PIC/fluid simulations to model the plasma’s overall behavior. Densities of up to 10^19 cm-3 have been measured on the electrode surfaces, decreasing by several orders of magnitude both radially and axially across the vacuum gap. Electrode plasma expansion velocities of up to 10 cm/microsecond correlate well with the decreasing impedance profile (~0.5 Ohms/ns) observed during the pulse.

electron beam diodes↗

Data Diodes in Support of Trustworthy Cyber Infrastructure

Interconnections between process control networks and en- terprise networks has resulted in the proliferation of stan- dard communication protocols in industrial control systems which exposes instrumentation, control systems, and the critical infrastructure components they operate to a variety of cyber attacks. Various standards and technologies have been proposed to protect industrial control systems against cyber attacks and to provide them with confidentiality, in- tegrity, and availability. Among these technologies, data diodes provide protection of critical systems by the means of physically enforcing traffic direction on the network. In order to deploy data diodes effectively, it is imperative to un- derstand the protection they provide, the protection they do not provide, their limitations, and their place in the larger security infrastructure. In this work, we briefly review the security challenges in an industrial control system, study data diodes, their functionalities and limitations, and pro- pose a scheme for their effective deployment in trusted pro- cess control networks (TPCNs.)

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

{sup 32}P Brachytherapy Conformal Source Model RIC-100 for High-Dose-Rate Treatment of Superficial Disease: Monte Carlo Calculations, Diode Measurements, and Clinical Implementation

Purpose: A novel {sup 32}P brachytherapy source has been in use at our institution intraoperatively for temporary radiation therapy of the spinal dura and other localized tumors. We describe the dosimetry and clinical implementation of the source. Methods and Materials: Dosimetric evaluation for the source was done with a complete set of MCNP5 Monte Carlo calculations preceding clinical implementation. In addition, the depth dose curve and dose rate were measured by use of an electron field diode to verify the Monte Carlo calculations. Calibration procedures using the diode in a custom-designed phantom to provide an absolute dose calibration and to check dose uniformity across the source area for each source before treatment were established. Results: Good agreement was established between the Monte Carlo calculations and diode measurements. Quality assurance measurements results are provided for about 100 sources used to date. Clinical source calibrations were usually within 10% of manufacturer specifications. Procedures for safe handling of the source are described. Discussion: Clinical considerations for using the source are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication and characterization of n-type aluminum-boron co-doped ZnO on p-type silicon (n-AZB/p-Si) heterojunction diodes

Graphical abstract: - Highlights: • n-AZB/p-Si heterojunction diodes were formed. • n-AZB/p-Si diode annealed at 700 °C showed best rectifying behavior. • Zn{sub 2}SiO{sub 4} was formed at 800 °C. • n and ϕ{sub b} were estimated to be 1.63 and 0.4 eV, respectively, at 700 °C. • Tailoring of BG was attributed to annealing induced stresses in the films. - Abstract: In this paper, the growth of n-type aluminum boron co-doped ZnO (n-AZB) on a p-type silicon (p-Si) substrate by sol–gel method using spin coating technique is reported. The n-AZB/p-Si heterojunctions were annealed at different temperatures ranging from 400 to 800 °C. The crystallite size of the AZB nanostructures was found to vary from 28 to 38 nm with the variation in annealing temperature. The band gap of the AZB decreased from 3.29 to 3.27 eV, with increasing annealing temperature from 400 to 700 °C and increased to 3.30 eV at 800 °C probably due to the formation of Zn{sub 2}SiO{sub 4} at the interface. The band gap variation is explained in terms of annealing induced stress in the AZB. The n-AZB/p-Si heterojunction exhibited diode behavior. The best rectifying behavior was exhibited at 700 °C.

36 MATERIALS SCIENCE↗

Weekly Verification of Dosimetric Data for Virtual Wedge Using a 2D Diode Detector Array

A linac manufacturer has recommended that users measure virtual wedge (VW) angle and VW factor as a weekly quality assurance (QA) procedure. The purpose of this study was to investigate whether a 2D diode detector array (MapCHECK{sup TM}) is a useful tool for the verification of dosimetric data for VW. Measurements were performed on 2 linear accelerators (4, 6, and 10 MV) at 10-cm depth for a field size of 10 x 10 cm{sup 2} and with wedge angles of 15, 30, 45, and 60{sup o}. To verify the VW dose distributions generated by the treatment planning system (TPS), we confirmed that agreement between TPS data and measurements were {<=}2% dose difference or 2-mm distance-to-agreement based on American Association of Physicists in Medicine Task Group Report 53 (AAPM TG-53). We present here the results of a 1-year evaluation of VW by means of a 2D diode detector array. The maximum 2-fold standard deviation of the measured wedge angle turned out to be within 1.0, and all measured VW factors to be 1.00 {+-} 0.03. Although >95% of the points measured for 6 and 10 MV were generally within the tolerance of the dose distribution as mentioned above, the percentage of agreement between the measured data for 4 MV and TPS data were somewhat below 90%. We also verified generally good reproducibility for the dose distribution. The 2-D diode detector array was thus found to be useful as a tool for weekly VW QA.

61 RADIATION PROTECTION AND DOSIMETRY↗