Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Collection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Angles and Daemons: Spin Correlations at the LHC

The Large Hadron Collider has recently started collecting data, opening a new energy regime. This will allow us to probe further than ever before many of the current mysteries of the field. New physics beyond the Standard Model, the field's current paradigm, could manifest itself via new particles. In addition, the Higgs boson, hypothesized as a consequence of electroweak symmetry breaking, remains undiscovered. At the time of discovery, the properties of such particles will be unknown. In order to understand the nature of any new physics, it will be important to understand the properties of that new particle. Methods are presented for measuring its spin, parity and coupling to the Standard Model particles. These methods are implemented at the Compact Muon Solenoid experiment and an analysis is presented with the data collected during 2010 and 2011 running at the Large Hadron Collider. An application of these techniques is used to make a measurement of the weak mixing angle. A current status of the search for the Higgs boson is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Subalpine and alpine species range shifts with climate change: temperature and soil moisture manipulations to test species and population responses (Final Report)

The Alpine Treeline Warming Experiment (ATWE) was established in 2008-2009 to experimentally test how climate change would affect species ranges at and beyond the cold edge limits of forest growth. One key finding was that warming can hinder upslope tree migration by increasing seedling water stress and reducing seedling survival. We found evidence for more conservative traits in seedlings from high elevation tree populations, which may further slow tree expansion into the current alpine. In the alpine, warming may only increase productivity if summer rain increases, as dominant alpine life forms were negatively affected by heating unless water was added. The ATWE experimental design and focus on dynamic vegetation were novel, and the setting at the mountain treeline transition was important to understanding effects of climate variability and change on water resources, carbon cycling and biodiversity. We ended climate manipulations and removed associated infrastructure from the field in 2016 following 8 years of data collection. To date, 5 MS theses and 18 peer-reviewed papers have been published or accepted (including one that yielded the cover image in Global Change Biology, left), and 1 PhD thesis and at least 5 papers are in review or active development. Numerous past seasonal and long-term field staff have gone on to graduate school, and subsequently to research positions as university faculty or agency scientists. PI Kueppers continues collecting data on soil microclimate and seedling survival for long-lived tree species to fill a critical gap in knowledge regarding the seedling-to-sapling transition across species and elevations. Primary project data is housed on the project’s virtual server, organized according to topic. Published data and model code is available either through the project website or via other permanent archives. Our results are influencing understanding and modeling of climate and genetic constraints on dynamic vegetation change across the landscape, particularly in the mountains of the Western U.S.

54 ENVIRONMENTAL SCIENCES↗

Considerations for Corridor and Community DC Fast Charging Complex System Design

The Idaho National Laboratory (INL), a U.S. Department of Energy (DOE) national laboratory located in Idaho Falls, Idaho, has been DOE’s lead laboratory for the field testing of light-duty plug-in electric vehicles (PEVs), charging infrastructure, and other alternative vehicle technologies for 25 years. INL has tested and collected data from more than 17,000 charging stations, documenting efficiencies, charge profiles, and PEV drivers’ behaviors when using charging infrastructure. Based on the experience of INL staff and support personnel, DOE requested that INL perform three tasks: • Identify pertinent lessons learned from previous direct current (DC) fast charger (DCFC) deployment and data collection activities in order to perform an analysis of the experience to date with DC fast charging systems • Establish the criteria for siting DC fast charging systems, including access to current or future sizeable penetrations of PEVs and existing power, the potential to be used by local (intracity) as well as pass-through (intercity) PEV drivers, expandability, and accessible to the federal highway system • Develop a draft system specification that lists the components that will be incorporated in a DC fast charging complexes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

3013 Inner Can Lid Leak Test System Development

Contained in this report is a description of the 3013 inner container lid leak detection system, a listing of the data collected to validate the system and a statistical analysis of collected data. The 3013 Container Surveillance Program provides assessment criteria and evaluates 3013 containers selected from the storage inventory for potential degradation mechanisms. The 3013 outer container is the boundary credited to prevent release of material to the environment. The integrity of the outer container is only at risk if the inner container loses its seal and allows corrosive gases to diffuse into the outer container. To date, the determination of potential outer container exposure to corrosive gases has been through comparison of the gas analysis of the annular space and the inner container. If the two volumes have the same gas composition and pressure, then the inner container may have leaked. The leak detection system described in this report will provide a direct measurement of the integrity of the inner container, and if approved, will provide for the elimination of gas analysis. The inner container lid leak testing system consists of two basic parts: the Agilent leak testing instrument and the leak test fixture. The test fixture base provides the connection between the leak test instrument and the test sample. This connection allows helium to flow into the leak detector when a leak path exists in the test sample allowing leak measurement to be performed. The tests reported here were conducted in a cold lab using a configuration very similar, but not identical to, the configuration anticipated when installed in a glove box. A total of sixty-five leak rate measurements were made on 10 containers and the data is included in the report. The data analysis shows that the leak detection system can identify leaks in the lid, including the weld and heat affected zone of 3013 inner containers, during destructive examination. The measurements taken support that a 3013 IC lid with a leak rate value greater than 2.0 x 10 -7 atm cc/sec will be identified using the leak test system prior to introduction into a glove box. These results from the baseline for future tests of the leak test system after it is installed in the glove box for use as part of surveillance DE.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Measurement of the Attenuation of Drifting Electrons in the MicroBooNE LArTPC

MicroBooNE, an 85-ton active mass liquid-argon time-projection chamber (LArTPC) detector located on the Fermilab’s Booster Neutrino Beamline (BNB), is designed to both probe neutrino physics phenomena and further develop the LArTPC detector technology. MicroBooNE, the largest currently operating LArTPC detector in the world, began collecting data in fall 2015. The exceptional imaging capabilities of LArTPCs allow unprecedented study of neutrino interactions. A fundamental requirement for the performance of such detectors is to maintain electronegative contaminants such as oxygen and water at extremely low concentrations, which otherwise can capture the ionization electrons. This note presents a first measurement of the electron attenuation as a function of drift time, using cosmic ray muon data collected by MicroBooNE. The observed electron attenuation indicates that during stable purity period, the lowest electron drift-lifetime observed is 18.0 ms which corresponds to a charge loss of 12% over the full drift distance at an electric field of 0.273 kV/cm and an O 2 equivalent contamination of 17 ppt. This is an indication that the argon purification and recirculation system of MicroBooNE is performing successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2016 Site 300 Bat Monitoring (Final Report)

Garcia and Associates (GANDA) was contracted by the Lawrence Livermore National Laboratory (LLNL) to design and execute a long-term passive bat monitoring program for Site 300, southwest of Tracy, California. This effort included consulting and collaborating with LLNL staff for the acquisition of monitoring equipment, data collection, data storage, data transfer and data analysis.

54 ENVIRONMENTAL SCIENCES↗

Wide Area 3D Measurement System for Analysis of 3013 Inner Container Closure Weld Region

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR, a laser confocal microscope (LCM) is used to perform close visual examination of the surface and to measure corrosion features on the surface. However, in FY20, the introduction of the Wide Area 3D Measurement System (WAMS) was tested as a method for faster inspection of the ICCWR. Optimization of the WAMS parameters for data collection was carried out using a generic tear-drop type sample containing large and fine Stress Corrosion Cracking (SCC) fractures and high resolution images were compared to the image obtained with the LCM. Although the image with the LCM shows higher resolution than the WAMS images, the small features can be still identified in the WAMS images. The advantage of collecting data for the full circumference using the WAMS is that it can take about a week to complete, which represents 1/16 of the time needed with the LCM. Nonetheless, both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS can be utilized to obtain images for faster screening or identification of corrosion features on the surface while the LCM can be utilized to obtain higher resolution images of those areas identified by the WAMS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation of Engine Expansion for Transparent Nozzle Combustion Research

A solenoid valve system and the ability to remotely control devices were added to the transparent nozzle experimental setup. The remote control of the devices allow a user to completely control the experiment via a computer interface. The user can collect data (low speed data acquisition of pressure and temperature and high speed data acquisition of voltage), set injection pressure of the system, and control timing of triggering solenoids, data collection, cameras and injection. The solenoid valve system was shown to work properly and allow for the simulation of engine expansion by cutting off the intake flow of pressure and opening the exhaust flow to a vent. The solenoid valve setup was also shown to help with the problems of splash back and air bubbles forming inside the sack and nozzle tip.

33 ADVANCED PROPULSION SYSTEMS↗

Fermilab’s Muon Campus: Status, Experiments, and Future

The Fermilab Muon Campus, repurposed Tevatron-era Antiproton Source facilities, is currently the home to the g-2 and Mu2e muon experiments. Collecting data since 2017, the g-2 experiment is wrapping up a final run before the Muon Campus transitions to Mu2e operation. Currently in the commissioning process, the Mu2e experiment is expected to begin calibration and data collection in fiscal year 2024. A majority of the Muon Campus is shared between the two experiments, however the modes of operation for each are significantly different. An 8 GeV primary proton beam strikes a target to produce a 3.1 GeV/c secondary muon beam for g-2, while the Mu2e experiment uses the Delivery Ring, formerly the Antiproton Accumulator Ring, for a pulsed, resonantly extracted, 8 kW, 8 GeV proton beam incident on a target in the experiment's target hall to produce a muon beam for the experiment. The design and current state of the Muon Campus and the current and future plans of the g-2 and Mu2e experiments, including the transition between operating modes, will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Destructive Analysis of TRISO Particles: Crush/Burn/Leach Followed by Davies-Gray Titration and IDMS

The accurate accounting of nuclear materials is a cornerstone of international nuclear safeguards. One emerging challenge in this domain is the fabrication of TRIstructural ISOtropic (TRISO) particle fuels. Although these innovative fuel forms are critical for advanced reactor applications, their robust refractory ceramics and coating compositions present significant obstacles to destructive analysis (DA) methods. Ensuring full and quantitative recovery from these particles is essential for accurate mass accountancy. The current study was initiated to address these challenges, first by validating a previously established destructive method developed by Oak Ridge National Laboratory (ORNL) for the quantitative recovery of uranium from TRISO particles and then following that process with uranium content determination through isotope dilution mass spectrometry (IDMS) and Davies-Gray titration. This study expands on the scope of a digestive method that was developed under the Advanced Gas Reactor Fuel Development and Qualification program and is currently implemented in both the Coated Particle Fuel Development Laboratory and Irradiated Fuels Examination Laboratory at ORNL. The success of the previous Advanced Gas Reactor work relied on developing a DA method to evaluate the fabrication process and reactor experiments. The methodology described in this report was designed to rigorously investigate the efficacy of the crush/burn/leach sample preparation of TRISO particles; it aims to quantify uranium recovery while also assessing the effects of TRISO constituents (e.g., silicon and zirconium) on analytical precision and accuracy. By comparing the results from the titration method and IDMS, we sought to determine whether existing analytical procedures accepted by the International Atomic Energy Agency (IAEA) could be effectively translated to TRISO fuel forms. The team employed an approach that involved processing replicate TRISO samples, optimizing the milling (i.e., crushing) step and performing serial leaches. The elemental composition of the analytical samples was examined to prepare for interference studies in the second year of this project. The integration of gamma spectrometry to verify residual uranium activity further strengthened the validation. Statistical methods were applied to the collected data to evaluate the uncertainties arising from sampling, sample preparation and uranium quantification. These uncertainties were then compared to the IAEA’s international target values (ITVs). Additional data collected in upcoming project work will strengthen the uncertainty estimates. Ultimately, it is hoped that this project will contribute materially to the body of work related to characterization of TRISO based fuels for the purpose of material accountancy and its applications to international safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hanford Site Rare Plant Monitoring Report for Calendar Year 2023-2024

This report summarizes rare plant monitoring data collected in calendar years (CY) 2023 through CY 2024 and provides management recommendations accordingly. DOE/RL-2021-35, Central Hanford Rare Plant Management Plan, guides the approach to rare plant monitoring and management at the Hanford Site. In CYs 2023 and 2024, rare plant monitoring efforts occurred on the portion of the Hanford Site managed by the Hanford Field Office (HFO; Figure 1-1), referred to herein as Central Hanford. The goal of monitoring is to collect data to evaluate the conservation status of rare plant species. Surveys conducted in CY 2023 through CY 2024 built on previous monitoring efforts, tracking the abundance and distribution of rare plants at Central Hanford. Results from previous monitoring efforts are included for reference. Monitoring data are submitted to the Washington Natural Heritage Program (WNHP) to evaluate statewide conservation statuses.

54 ENVIRONMENTAL SCIENCES↗

Hanford Site Rare Plant Monitoring Report for Calendar Year 2025

This report summarizes rare plant monitoring data collected in calendar year (CY) 2025 and provides management recommendations accordingly. DOE/RL-2021-35, Central Hanford Rare Plant Management Plan, guides the approach to rare plant monitoring and management at the Hanford Site. In CY 2025, rare plant monitoring efforts occurred on the portion of the Hanford Site managed by the U.S. Department of Energy, Hanford Field Office (HFO; Figure 1-1), referred to herein as Central Hanford. The goal of monitoring is to collect data to evaluate the conservation status of rare plant species. Surveys conducted in CY 2025 built on previous monitoring efforts, tracking the abundance and distribution of rare plants at Central Hanford. Results from previous monitoring efforts are included for reference. Monitoring data are submitted to the Washington Natural Heritage Program (WNHP), part of the Washington State Department of Natural Resources (WA DNR), to evaluate statewide conservation statuses.

54 ENVIRONMENTAL SCIENCES↗

Central Hanford Vernal Pool Monitoring Report for Calendar Year 2025

This report summarizes vernal pool monitoring data collected in calendar year (CY) 2025 and provides management recommendations. Monitoring efforts occurred on the portion of the Hanford Site managed by the U.S. Department of Energy, Hanford Field Office (HFO), referred to herein as Central Hanford. The goal of monitoring is to collect data to evaluate the conservation status of this imperiled habitat. Monitoring in CY 2025 built on previous efforts, as reported in HNF-62115, Ecological Monitoring Report Vernal Pools on the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Digital Silicon Photomultipliers

Digital Silicon photomultipliers (Digital SiPMs) have become an increasingly viable option for single-photon detection due to their compact size and precise timing and resolution. The following work characterizes the noise performance of a diSiPM designed and tested in-house at Fermilab. The SiPM consists of a 26x32 array of single-photon avalanche diode (SPAD) cells. Through the implementation of a shift register masking circuit, individual SPAD cells can be enabled and disabled at will, allowing for precise detection measurements of single columns (accumulator channels) and cells. The provided circuit design operates on voltage clock pulses and collects data on clock edges allowing for precise tuning of the data collection process by varying the clock frequency, pulse width, and integration period.

Shoemaker, Oliver [U. Chicago (main)]↗

Status of China's Energy Efficiency Standards and Labels for Appliances and International Collaboration

China first adopted minimum energy performance standards (MEPS) in 1989. Today, there are standards for a wide range of domestic, commercial and selected industrial equipment. In 1999, China launched a voluntary endorsement label, which has grown to cover over 40 products including water-saving products (See Figure 1). Further, in 2005, China started a mandatory energy information label (also referred to as the 'Energy Label'). Today, the Energy Label is applied to four products including: air conditioners; household refrigerators; clothes washers; and unitary air conditioners (See Figure 2). MEPS and the voluntary endorsement labeling specifications have been updated and revised in order to reflect technology improvements to those products in the market. These programs have had an important impact in reducing energy consumption of appliances in China. Indeed, China has built up a strong infrastructure to develop and implement product standards. Historically, however, the government's primary focus has been on the technical requirements for efficiency performance. Less attention has been paid to monitoring and enforcement with a minimal commitment of resources and little expansion of administrative capacity in this area. Thus, market compliance with both mandatory standards and labeling programs has been questionable and actual energy savings may have been undermined as a result. The establishment of a regularized monitoring system for tracking compliance with the mandatory standard and energy information label in China is a major area for program improvement. Over the years, the Collaborative Labeling and Appliance Standards Program (CLASP) has partnered with several Chinese institutions to promote energy-efficient products in China. CLASP, together with its implementing partner Lawrence Berkeley National Laboratory (LBNL), has assisted China in developing and updating the above-mentioned standards and labeling programs. Because of the increasing need for the development of a monitoring system to track compliance with standards and labeling, CLASP, with support from Japan's Ministry of Economy, Trade and Industry (METI), has expanded its ongoing collaboration with the China National Institute of Standards (CNIS) to include enforcement and monitoring. CNIS has already begun working on the issue of compliance. CNIS has conducted modest sample testing in 2006 for refrigerators, freezers and room air-conditioners, and repeated the same task in 2007 with a similar sample size for three products (refrigerators, freezers, air-conditioners and clothes washers). And, CNIS, with technical support from LBNL, has analyzed the data collected through testing. At the same time, parallel effort has also been paid to look at the potential impact of the label to 2020. In conjunction with CNIS, CLASP technical experts reviewed the standards development timeline of the four products currently subject to the mandatory energy information label. CLASP, with the support of METI/IEEJ, collaborated with CNIS to develop the efficiency grades, providing: technical input to the process; comment and advice on particular technical issues; as well as evaluation of the results. In addition, in order to effectively evaluate the impact of the label on China's market, CLASP further provided assistance to CNIS to collect data on both the efficiency distribution and product volume distribution of refrigerators on the market. This short report summarizes the status of Standards and Labeling program, current enforcement and monitoring mechanism in China, and states the importance of international collaborations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hadron-argon cross-section measurements in ProtoDUNE-SP

The single-phase liquid argon ProtoDUNE detector (ProtoDUNE-SP) is located at CERN’s neutrino platform facility and serves as a prototype to validate the technology for the 10-kton fiducial mass liquid argon detectors for the DUNE experiment. ProtoDUNE-SP was exposed to a variety of test-beam particles (electrons, muons, pions, kaons, and protons) towards the end of 2018 collecting data in a broad range of momenta, from 0.3 - 7 GeV/c. The results will improve the understanding of final-state interactions in neutrino-argon cross-sections. The progress of the analyses towards the cross-section measurements on argon from the test-beam data collected at protoDUNE-SP will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Residential Building Simulations Through Large-Scale Empirical Validation

Residential building energy simulations are increasingly used for energy-efficient building design, codes and standards analysis, home certifications and ratings, utility programs, and technology assessments. Various software tools exist to perform residential building simulations, and these tools often use different models, inputs, and assumptions. This leads to inconsistencies that can undermine confidence in the predicted results. Validation of these tools can increase confidence by ensuring their accuracy and consistency. One way to validate simulation tools is through empirical testing, which compares predicted energy usage to measured utility billing data. This paper describes the process of data collection, data standardization, and empirical validation, and illustrates its use with our residential EnergyPlus (R)-based software. The data and process can be extended to other simulation tools and contribute to improving residential building simulations more broadly.

empirical validation↗

Energy Leaders: The Catalyst for Strategic Energy Management

This study investigates the crucial role energy leaders play in driving strategic energy management (SEM) and accelerating cost savings within a manufacturing organization and consequently, the industrial sector. Whereas energy efficiency can be seen as an innovative business practice with irrefutable cost benefits, its effective implementation requires strategic leadership and a structured approach. This research analyzes data collected from 120 participants representing 71 companies attending the Energy Bootcamp events organized by the U.S. Department of Energy’s (DOE) Better Plants program. The collected data focused on the state of SEM implementation, the presence and responsibilities of energy leaders, and the formation and function of energy teams. The findings reveal a significant gap between the perceived importance of SEM and its actual adoption, highlighting the need for strong leadership to drive behavioral changes by championing energy efficiency initiatives. Results indicate that effective energy leaders possess a diverse skill set, including the ability to secure top management buy-in, foster a culture of energy consciousness, and collaborate across departments. This study emphasizes the importance of empowering energy leaders with clearly defined roles and responsibilities as well as the authority to build and lead cross-functional energy teams. Furthermore, integrating energy management into existing organizational structures and leveraging readily available resources are identified as key factors for successful implementation. This research underscores how dedicated leadership and effective SEM practices help achieve industrial energy efficiency goals, providing practical insights for organizations seeking to improve performance and contribute to a resilient future.

energy leader↗