Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Assembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

ESD Test Apparatus for Soldering Irons

ESDA (Electrostatic Discharge Association) ESD STM 13.1-2000 requires frequent testing of the voltage leakage from the tip of a soldering iron and the resistance from the tip of the soldering iron to the common point ground. Without this test apparatus, the process is time-consuming and requires several wires, alligator clips, or test probes, as well as additional equipment. Soldering iron tips must be tested for electrostatic discharge risks frequently, and this typically takes a lot of time in setup and testing. This device enables the operator to execute the full test in one minute or less. This innovation is a simple apparatus that plugs into a digital multimeter (DMM) and the Common Point Ground (CPG) reference. It enables the user to perform two of the electrostatic discharge tests required in ESD STM 13.1-2000. The device consists of a small black box with two prongs sticking out of one end, two inputs on the opposite end (one of the inputs is used to connect the reference CPG to the DMM), and a metal tab on one side. Inside the box are wires, several washers of various materials, and assembly hardware (nuts and screws/bolts). The device is a passive electronic component that is plugged into a DMM. The operator sets the DMM to read voltage. The operator places the heated tip of the soldering iron onto the metal tab with a small amount of solder to ensure a complete connection. The voltage is read and recorded. The operator switches the DMM to read resistance. The operator places the heated tip of the soldering iron onto the metal tab with a small amount of solder to ensure a complete connection. The resistance is recorded. If the recorded voltage and resistance are below a number stated in ESDA ESD STM 13.1-2000, the test is considered to pass. The device includes all the necessary wiring internal to its body so the operator does not need to do any independent wiring, except for grounding. It uses a stack of high-thermal-resistance washers to minimize the heat transfer from the soldering iron to the wiring used to measure the resistance and voltages. This minimizes thermal error. The device allows very rapid execution of a test that is performed frequently.

Sancho, Jose↗

A Microfluidic DNA Library Preparation Platform for Next-Generation Sequencing

Next-generation sequencing (NGS) is emerging as a powerful tool for elucidating genetic information for a wide range of applications. Unfortunately, the surging popularity of NGS has not yet been accompanied by an improvement in automated techniques for preparing formatted sequencing libraries. To address this challenge, we have developed a prototype microfluidic system for preparing sequencer-ready DNA libraries for analysis by Illumina sequencing. Our system combines droplet-based digital microfluidic (DMF) sample handling with peripheral modules to create a fully-integrated, sample-in library-out platform. In this report, we use our automated system to prepare NGS libraries from samples of human and bacterial genomic DNA. E. coli libraries prepared on-device from 5 ng of total DNA yielded excellent sequence coverage over the entire bacterial genome, with .99% alignment to the reference genome, even genome coverage, and good quality scores. Furthermore, we produced a de novo assembly on a previously unsequenced multi-drug resistant Klebsiella pneumoniae strain BAA-2146 (KpnNDM). The new method described here is fast, robust, scalable, and automated. Our device for library preparation will assist in the integration of NGS technology into a wide variety of laboratories, including small research laboratories and clinical laboratories.

59 BASIC BIOLOGICAL SCIENCES↗

Spent Fuel Verification Using a Digital Cerenkov Viewing Device

A portable digital Cerenkov viewing device (DCVD-e) was developed to verify light water reactor fuel cooled as long as 40 years with a burnup of 10,000 MWd/t U. This measurement regime is beyond the capability of the improved Cerenkov viewing Device (ICVD) used by the International Atomic Energy Agency inspectors for spent fuel verification. The DCVD-e has verified spent fuel with a very low burnup of 1,200 MWd/t U cooled for 36 years and we expect to verify this assembly cooled past 60 years. This exceeds the target requirement. The verification method requires no fuel movement and no water contact. It is possible for one inspector to perform a fuel pond verification. Future studies include instrument characterization to allow the detection of partial defects. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Correlation Techniques as Applied to Pose Estimation in Space Station Docking

The telerobotic assembly of space-station components has become the method of choice for the International Space Station (ISS) because it offers a safe alternative to the more hazardous option of space walks. The disadvantage of telerobotic assembly is that it does not provide for direct arbitrary views of mating interfaces for the teleoperator. Unless cameras are present very close to the interface positions, such views must be generated graphically, based on calculated pose relationships derived from images. To assist in this photogrammetric pose estimation, circular targets, or spots, of high contrast have been affixed on each connecting module at carefully surveyed positions. The appearance of a subset of spots essentially must form a constellation of specific relative positions in the incoming digital image stream in order for the docking to proceed. Spot positions are expressed in terms of their apparent centroids in an image. The precision of centroid estimation is required to be as fine as 1I20th pixel, in some cases. This paper presents an approach to spot centroid estimation using cross correlation between spot images and synthetic spot models of precise centration. Techniques for obtaining sub-pixel accuracy and for shadow, obscuration and lighting irregularity compensation are discussed.

Rollins, J. Michael↗

On the Hunt for the Origins of the Orphan–Chenab Stream: Detailed Element Abundances with APOGEE and Gaia

Stellar streams in the Galactic halo are useful probes of the assembly of galaxies like the Milky Way. Many tidal stellar streams that have been found in recent years are accompanied by a known progenitor globular cluster or dwarf galaxy. However, the Orphan–Chenab (OC) stream is one case where a relatively narrow stream of stars has been found without a known progenitor. In an effort to find the parent of the OC stream, we use astrometry from the early third data release of ESA's Gaia mission (Gaia EDR3) and radial velocity information from the Sloan Digital Sky Survey (SDSS)-IV Apache Point Observatory Galactic Evolution Experiment (APOGEE) survey to find up to 13 stars that are likely members of the OC stream. We use the APOGEE survey to study the chemical nature (for up to 10 stars) of the OC stream in the α (O, Mg, Ca, Si, Ti, and S), odd-Z (Al, K, and V), Fe-peak (Fe, Ni, Mn, Co, and Cr), and neutron-capture (Ce) elemental groups. We find that the stars that make up the OC stream are not consistent with a monometallic population and have a median metallicity of -1.92 dex with a dispersion of 0.28 dex. Our results also indicate that the α elements are depleted compared to the known Milky Way populations and that its [Mg/Al] abundance ratio is not consistent with second-generation stars from globular clusters. The detailed chemical pattern of these stars, namely the [α/Fe]–[Fe/H] plane and the metallicity distribution, indicates that the OC stream progenitor is very likely to be a dwarf spheroidal galaxy with a mass of ~10 6 M ⊙ .

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Selected CERES Electronic Component Survivability under Simulated Overvoltage Conditions

In August, 1998 a Clouds and the Earth's Radiant Energy System (CERES) instrument telemetry housekeeping parameter generated a yellow warning message that indicated an on-board + 15V Data Acquisition Assembly (DAA) power converter deregulation anomaly. An exhaustive investigation was undertaken to understand this anomaly and the long-term consequences which have severely reduced CERES operations on the Tropical Rainfall Measuring Mission (TRMM) spacecraft. Among investigations performed were ground tests that approximated the on-board electronic circuitry using a small quantity of flight identical components exposed to maximum spacecraft bus over-voltage conditions. These components include monolithic integrated microcircuits that perform analog signal conditioning on instrument sensor signals and an analog- to-digital converter (ADC) for the entire DAA. All microcircuit packages have either a bipolar silicon design with internal current limiting protections or have a complementary metal oxide semiconductor (CMOS) design with bias protections. Ground tests that have been running for approximately 8 months have indicated that these components are capable of withstanding as much as twice their input supply voltage ratings without noticeable performance degradation. These data provide CERES operators with confidence of being able to continue science operations over the remaining life of the TRMM mission. This paper will discuss this anomaly and some possible causes, a simulator of affected electronics, test results, prognosis for future CERES operations, and conclusions.

Chapman, John J.↗

Second-Generation Six-Limbed Experimental Robot

The figure shows the LEMUR II - the second generation of the Limbed Excursion Mechanical Utility Robot (LEMUR), which was described in "Six-Legged Experimental Robot" (NPO-20897), NASA Tech Briefs, Vol. 25, No. 12 (December 2001), page 58. The LEMUR II incorporates a number of improvements, including new features, that extend its capabilities beyond those of its predecessor, which is now denoted the LEMUR I. To recapitulate: the LEMUR I was a six-limbed robot for demonstrating robotic capabilities for assembly, maintenance, and inspection. The LEMUR I was designed to be capable of walking autonomously along a truss structure toward a mechanical assembly at a prescribed location and to perform other operations. The LEMUR I was equipped with stereoscopic video cameras and image-data-processing circuitry for navigation and mechanical operations. It was also equipped with a wireless modem, through which it could be commanded remotely. Upon arrival at a mechanical assembly, the LEMUR I would perform simple mechanical operations with one or both of its front limbs. It could also transmit images to a host computer. Each of the six limbs of the LEMUR I was operated independently. Each of the four rear limbs had three degrees of freedom (DOFs), while each of the front two limbs had four DOFs. The front two limbs were designed to hold, operate, and/or be integrated with tools. The LEMUR I included an onboard computer equipped with an assortment of digital control circuits, digital input/output circuits, analog-to-digital converters for input, and digital-to-analog (D/A) converters for output. Feedback from optical encoders in the limb actuators was utilized for closed-loop microcomputer control of the positions and velocities of the actuators. The LEMUR II incorporates the following improvements over the LEMUR I: a) The drive trains for the joints of the LEMUR II are more sophisticated, providing greater torque and accuracy. b) The six limbs are arranged symmetrically about a hexagonal body platform instead of in straight lines along the sides. This symmetrical arrangement is more conducive to omnidirectional movement in a plane. c) The number of degrees of freedom of each of the rear four limbs has been increased by one. Now, every limb has four degrees of freedom: three at the hip (or shoulder, depending on one s perspective) and one at the knee (or elbow, depending on one s perspective). d) Now every limb (instead of only the two front limbs) can perform operations. For this purpose, each limb is tipped with an improved quick-release mechanism for swapping of end-effector tools. e) New end-effector tools have been developed. These include an instrumented rotary driver that accepts all tool bits that have 0.125-in. (3.175-mm)-diameter shanks, a charge-coupled-device video camera, a super bright light-emitting diode for illuminating the work area of the robot, and a generic collet tool that can be quickly and inexpensively modified to accept any cylindrical object up to 0.5 in. (12.7 mm) in diameter. f) The stereoscopic cameras are mounted on a carriage that moves along a circular track, thereby providing for omnidirectional machine vision. g) The control software has been augmented with software that implements innovations reported in two prior NASA Tech Briefs articles: the HIPS algorithm ["Hybrid Image-Plane/Stereo Manipulation" (NPO-30492), Vol. 28, No. 7 (July 2004), page 55] and the CAMPOUT architecture ["An Architecture for Controlling Multiple Robots" (NPO-30345), Vol. 28, No. 10 (October 2004), page 65].

Kennedy, Brett↗

Embedded Fiber Optic Probes to Measure Detonation Velocities Using the Photonic Doppler Velocimeter

Detonation velocities for high explosives can be in the 7 to 8 km/s range. Previous work has shown that these velocities may be measured by inserting an optical fiber probe into the explosive assembly and recording the velocity time history using a Fabry-Perot velocimeter. The measured velocity using this method, however, is the actual velocity multiplied times the refractive index of the fiber core, which is on the order of 1.5. This means that the velocimeter diagnostic must be capable of measuring velocities as high as 12 km/s. Until recently, a velocity of 12 km/s was beyond the maximum velocity limit of a homodyne-based velocimeter. The limiting component in a homodyne system is usually the digitizer. Recently, however, digitizers have come on the market with 20 GHz bandwidth and 50 GS/s sample rate. Such a digitizer coupled with high bandwidth detectors now have the total bandwidth required to make velocity measurements in the 12 km/s range. This paper describes measurements made of detonation velocities using a high bandwidth homodyne system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Special Nuclear Material Characterization Using Digital 3-D Position Sensitive CdZnTe Detectors and High Purity Germanium Spectrometers

Special nuclear material (SNM) monitoring often requires high resolution gamma-ray spectroscopy for material characterization. Portable systems and rapid deployment are also highly valued for some applications. Deployable gamma-ray imaging spectrometers using pixelated CdZnTe semiconductor detectors have become commercially available within the past three years to meet these requirements. CdZnTe systems have demonstrated room-temperature energy resolutions below 0.5% FWHM at 662 keV using single pixel events and below 0.7% FWHM at 662 keV using all events. The systems are able to go from storage to measurement in less than two minutes. Special nuclear materials were measured at the Y-12 National Security Complex and at the Device Assembly Facility at the Nevada National Security Site. The use of a CdZnTe system to measure uranium enrichment was demonstrated and uranium spectral features were compared to a commercially available high purity germanium (HPGe) spectrometer. The use of passive gamma ray spectroscopy techniques to estimate plutonium grade using CdZnTe detectors was demonstrated for the first time.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

PRIMUS: CONSTRAINTS ON STAR FORMATION QUENCHING AND GALAXY MERGING, AND THE EVOLUTION OF THE STELLAR MASS FUNCTION FROM z = 0-1

We measure the evolution of the stellar mass function (SMF) from z = 0-1 using multi-wavelength imaging and spectroscopic redshifts from the PRism MUlti-object Survey (PRIMUS) and the Sloan Digital Sky Survey (SDSS). From PRIMUS we construct an i < 23 flux-limited sample of {approx}40, 000 galaxies at z = 0.2-1.0 over five fields totaling Almost-Equal-To 5.5 deg{sup 2}, and from the SDSS we select {approx}170, 000 galaxies at z = 0.01-0.2 that we analyze consistently with respect to PRIMUS to minimize systematic errors in our evolutionary measurements. We find that the SMF of all galaxies evolves relatively little since z = 1, although we do find evidence for mass assembly downsizing; we measure a Almost-Equal-To 30% increase in the number density of {approx}10{sup 10} M{sub sun} galaxies since z Almost-Equal-To 0.6, and a {approx}< 10% change in the number density of all {approx}> 10{sup 11} M{sub sun} galaxies since z Almost-Equal-To 1. Dividing the sample into star-forming and quiescent using an evolving cut in specific star formation rate, we find that the number density of {approx}10{sup 10} M{sub sun} star-forming galaxies stays relatively constant since z Almost-Equal-To 0.6, whereas the space density of {approx}> 10{sup 11} M{sub sun} star-forming galaxies decreases by Almost-Equal-To 50% between z Almost-Equal-To 1 and z Almost-Equal-To 0. Meanwhile, the number density of {approx}10{sup 10} M{sub sun} quiescent galaxies increases steeply toward low redshift, by a factor of {approx}2-3 since z Almost-Equal-To 0.6, while the number of massive quiescent galaxies remains approximately constant since z Almost-Equal-To 1. These results suggest that the rate at which star-forming galaxies are quenched increases with decreasing stellar mass, but that the bulk of the stellar mass buildup within the quiescent population occurs around {approx}10{sup 10.8} M{sub sun}. In addition, we conclude that mergers do not appear to be a dominant channel for the stellar mass buildup of galaxies at z < 1, even among massive ({approx}> 10{sup 11} M{sub sun}) quiescent galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

ELECTRONICS UPGRADE OF HIGH RESOLUTION MASS SPECTROMETERS

High resolution mass spectrometers are specialized systems that allow researchers to determine the exact mass of samples to four significant digits by using magnetic and electronic sector mass analyzers. Many of the systems in use today at research laboratories and universities were designed and built more than two decades ago. The manufacturers of these systems have abandoned the support for some of the mass spectrometers and parts to power and control them have become scarce or obsolete. The Savannah River National Laboratory has been involved in the upgrade of the electronics and software for these legacy machines. The Electronics Upgrade of High Resolution Mass Spectrometers consists of assembling high-end commercial instrumentation from reputable manufacturers with a minimal amount of customization to replace the electronics for the older systems. By taking advantage of advances in instrumentation, precise magnet control can be achieved using high resolution current sources and continuous feedback from a high resolution hall-effect probe. The custom equipment include a precision voltage divider/summing amplifier chassis, high voltage power supply chassis and a chassis for controlling the voltage emission for the mass spectrometer source tube. The upgrade package is versatile enough to interface with valve control, vacuum and other instrumentation. Instrument communication is via a combination of Ethernet and traditional IEEE-488 GPIB protocols. The system software upgrades include precision control, feedback and spectral waveform analysis tools.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, November 1995

The contents include: 1) Mission Accomplished; 2) Resource Report: Marshall Space Flight Center; 3) NASA 1995 Software of the Year Award; 4) Microbolometers Based on Epitaxial YBa2Cu3O(sub 7-x) Thin Films; 5) Garnet Random-Access Memory; 6) Fabrication of SNS Weak Links on SOS Substrates; 7) High-Voltage MOSFET Switching Circuit; 8) Asymmetric Switching for a PWM H-Bridge Power Circuit; 9) Better Ohmic Contacts for InP Semiconductor Devices; 10) Low-Bandgap Thermovoltaic Materials and Devices; 11) Digital Frequency-Differencing Circuit; 12) Imaging Magnetometer; 13) Computer-Assisted Monitoring of a Complex System; 14) Buffered Telemetry Demodulator; 15) Compact Multifunction Inspection Head; 16) Optical Detection of Fractures in Ceramic Diaphragms; 17) Eddy-Current Detection of Cracks in Reinforced Carbon/Carbon; 18) Apparent Thermal Conductivity of Multilayer Insulation; 19) Optimizing Misch-Metal Compositions in Metal Hydride Anodes; 20) Device for Sampling Surface Contamination; 21) Probabilistic Failure Assessment for Fatigue; 22) Probabilistic Fatigue and Flaw-Propagation Analysis; 23) Windows Program for Driving the TDU-850 Printer; 24) Subband/Transform MATLAB Functions for Processing Images; 25) Computing Equilibrium Chemical Compositions; 26) Program Processes Thermocouple Readings; 27) ICAN-Second-Generation Integrated Composite Analyzer; 28) Integrated Composite Analyzer with Damping Capabilities; 29) Computing Efficiency of Transfer of Microwave Power; 30) Program Calculates Power Demands of Electronic Designs; 31) Cost-Estimation Program; 32) Program Estimates Areas Required by Electronic Designs; 33) Program to Balance Mapped Turbopump Assemblies; 34) BiblioTech; 35) Controlling Mirror Tilt With a Bimorph Actuator; 36) Burst-Disk Device Simulates Effect of Pyrotechnic Device; 37) Bearing-Mounting Concept Accommodates Thermal Expansion; 38) Parallel-Plate Acoustic Absorbers for Hot Environments; 39) Adjustable-Length Strut Withstands Large Cyclic Loads; 40) Tool Indicates Contact Angles in Bearing Raceways; 41) Gravity Slides With Magnetic Braking; 42) High-Torque, Lightweight, Pneumatically Driven Wrench for Small Spaces; 43) Device for Testing Compatibility of an O-Ring; 44) Magnetic Heat Pump Containing Flow Diverters; 45) Variable-Tilt Helicopter Rotor Mast; 46) "Beach-Ball" Robotic Rovers; 47) Apparatus Would Measure Temperatures of Ball Bearings; 48) Flexible Borescope for Inspecting Ducts; 49) Texturing Copper To Reduce Secondary Emission of Electrons; 50) Automated Laser Cutting in Three Dimensions; 51) Algorithm Helps Monitor Engine Operation; 52) Flexible Revision of Data-Processing Communications; 53) Software for Managing the Use of Land; 54) Thermal Strap Increases Cryocooling Efficiency; 55) Reversible Nut With Engagement Indication; 56) Control Algorithms for Kinematically Redundant Manipulators; 57) Computed Hydrogen-Flow Splits in a Rocket Engine; 58) Pressure and Thermal Modeling of Rocket Launches; 59) Field of View of a Spacecraft Antenna: Analysis and Software; 60) Digital Controller for Laser-Beam-Steering Subsystem; 61) More About Beam-Steering Subsystem for Laser Communication; 62) Digital Controller for Laser-Beam-Steering Subsystem: Part 2; 63) Interface Circuit Board for Space-Shuttle Communications; 64) Automated Planning of Spacecraft Telecommunications; 65) Artifacts of Spectral Analysis of Instrument Readings; 66) Neural-Network Controller for Vibration Suppression; 67) Adaptive Finite-Element Computation in Fracture Mechanics; 68) Attitude Control for the Cassini Spacecraft; 69) Analytical Model for Fluid Dynamics in a Microgravity Environment; 70) Study of Rocket-Engine Joints Bonded by NVCU/NARloy-Z; 71) Improved Silicon Nitride for Advanced Heat Engines; 72) Parameters for Welding Aluminum/Lithium Alloys; 73) Lightweight Composite Intertank Structure; 74) Foil Patches Seal Small Vacuum Leaks; 75) Data Base on Cables and Connectors; 76) Effect of Clock Mode on Radiation Hardnessf an ADC; and 77) Fault-Tolerant Control for a Robotic Inspection System.

Source record↗

THE APACHE POINT OBSERVATORY GALACTIC EVOLUTION EXPERIMENT: FIRST DETECTION OF HIGH-VELOCITY MILKY WAY BAR STARS

Commissioning observations with the Apache Point Observatory Galactic Evolution Experiment (APOGEE), part of the Sloan Digital Sky Survey III, have produced radial velocities (RVs) for {approx}4700 K/M-giant stars in the Milky Way (MW) bulge. These high-resolution (R {approx} 22, 500), high-S/N (>100 per resolution element), near-infrared (NIR; 1.51-1.70 {mu}m) spectra provide accurate RVs ({epsilon}{sub V} {approx} 0.2 km s{sup -1}) for the sample of stars in 18 Galactic bulge fields spanning -1 Degree-Sign -32 Degree-Sign . This represents the largest NIR high-resolution spectroscopic sample of giant stars ever assembled in this region of the Galaxy. A cold ({sigma}{sub V} {approx} 30 km s{sup -1}), high-velocity peak (V{sub GSR} Almost-Equal-To +200 km s{sup -1}) is found to comprise a significant fraction ({approx}10%) of stars in many of these fields. These high RVs have not been detected in previous MW surveys and are not expected for a simple, circularly rotating disk. Preliminary distance estimates rule out an origin from the background Sagittarius tidal stream or a new stream in the MW disk. Comparison to various Galactic models suggests that these high RVs are best explained by stars in orbits of the Galactic bar potential, although some observational features remain unexplained.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiple degree-of-freedom force and moment measurement for static propulsion testing using magnetic suspension technology

Innovative Information Systems (IIS), Inc. is in the process of designing and fabricating a high bandwidth force and moment measuring device (i.e. the Magnetic Thruster Test Stand). This device will use active magnetic suspension to allow direct measurements of the forces and torques generated by the rocket engines of the missile under test. The principle of operation of the Magnetic Thruster Test Stand (MTTS) is based on the ability to perform very precise, high bandwidth force and position measurements on an object suspended in a magnetic field. This ability exists due to the fact that the digital servo control mechanism that performs the magnetic suspension uses high bandwidth (10 kHz) position data (via an eddy-current proximity sensor) to determine the amount of force required to maintain stable suspension at a particular point. This force is converted into required electromagnet coil current, which is then output to a current amplifier driving the coils. A discussion of how the coil current and magnetic gap distance (the distance between the electromagnet and the object being suspended) is used to determine the forces being applied from the suspended assembly is presented.

Stuart, Keith↗

Land-use in Amazonia and the Cerrado of Brazil: State of Knowledge and GIS Database

We have assembled datasets to strengthen the LargeScale Biosphere Atmosphere Experiment in Amazonia (LBA). These datasets can now be accessed through the Woods Hole Research Center homepage (www.whrc.org), and will soon be linked to the Pre-LBA homepages of the Brazilian Space Research Institute's Center for Weather and Climate Prediction (Instituto de Pesquisas Espaciais, Centro de Previsao de Tempo e Estudos Climaticos, INPE/CPTEC) and through the Oak Ridge National Laboratory, Distributed Active Archive Center (ORNL/DMC). Some of the datasets that we are making available involved new field research and/or the digitization of data available in Brazilian government agencies. For example, during the grant period we conducted interviews at 1,100 sawmills across Amazonia to determine their production of sawn timber, and their harvest intensities. These data provide the basis for the first quantitative assessment of the area of forest affected each year by selective logging (Nepstad et al, submitted to Nature). We digitized the locations of all of the rural households in the State of Para that have been mapped by the Brazilian malaria combat agency (SUCAM). We also mapped and digitized areas of deforestation in the state of Tocantins, which is comprised largely of savanna (cerrado), an ecosystem that has been routinely excluded from deforestation mapping exercises.

Nepstad, Daniel C.↗

2007 Research and Engineering Annual Report

Selected research and technology activities at NASA Dryden Flight Research Center are summarized. These following activities exemplify the Center's varied and productive research efforts: Developing a Requirements Development Guide for an Automatic Ground Collision Avoidance System; Digital Terrain Data Compression and Rendering for Automatic Ground Collision Avoidance Systems; Nonlinear Flutter/Limit Cycle Oscillations Prediction Tool; Nonlinear System Identification Using Orthonormal Bases: Application to Aeroelastic/Aeroservoelastic Systems; Critical Aerodynamic Flow Feature Indicators: Towards Application with the Aerostructures Test Wing; Multidisciplinary Design, Analysis, and Optimization Tool Development Using a Genetic Algorithm; Structural Model Tuning Capability in an Object-Oriented Multidisciplinary Design, Analysis, and Optimization Tool; Extension of Ko Straight-Beam Displacement Theory to the Deformed Shape Predictions of Curved Structures; F-15B with Phoenix Missile and Pylon Assembly--Drag Force Estimation; Mass Property Testing of Phoenix Missile Hypersonic Testbed Hardware; ARMD Hypersonics Project Materials and Structures: Testing of Scramjet Thermal Protection System Concepts; High-Temperature Modal Survey of the Ruddervator Subcomponent Test Article; ARMD Hypersonics Project Materials and Structures: C/SiC Ruddervator Subcomponent Test and Analysis Task; Ground Vibration Testing and Model Correlation of the Phoenix Missile Hypersonic Testbed; Phoenix Missile Hypersonic Testbed: Performance Design and Analysis; Crew Exploration Vehicle Launch Abort System-Pad Abort-1 (PA-1) Flight Test; Testing the Orion (Crew Exploration Vehicle) Launch Abort System-Ascent Abort-1 (AA-1) Flight Test; SOFIA Flight-Test Flutter Prediction Methodology; SOFIA Closed-Door Aerodynamic Analyses; SOFIA Handling Qualities Evaluation for Closed-Door Operations; C-17 Support of IRAC Engine Model Development; Current Capabilities and Future Upgrade Plans of the C-17 Data Rack; Intelligent Data Mining Capabilities as Applied to Integrated Vehicle Health Management; STARS Flight Demonstration No. 2 IP Data Formatter; Space-Based Telemetry and Range Safety (STARS) Flight Demonstration No. 2 Range User Flight Test Results; Aerodynamic Effects of the Quiet Spike(tm) on an F-15B Aircraft; F-15 Intelligent Flight Controls-Increased Destabilization Failure; F-15 Integrated Resilient Aircraft Control (IRAC) Improved Adaptive Controller; Aeroelastic Analysis of the Ikhana/Fire Pod System; Ikhana: Western States Fire Missions Utilizing the Ames Research Center Fire Sensor; Ikhana: Fiber-Optic Wing Shape Sensors; Ikhana: ARTS III; SOFIA Closed-Door Flutter Envelope Flight Testing; F-15B Quiet Spike(TM) Aeroservoelastic Flight Test Data Analysis; and UAVSAR Platform Precision Autopilot Flight Results.

Stoliker, Patrick↗

Design, Assembly, and Testing of the Neutron Imaging Lens for the National Ignition Facility

The National Ignition Facility will begin testing DT fuel capsules yielding greater than 10^13 neutrons during 2010. Neutron imaging is an important diagnostic for understanding capsule behavior. Neutrons are imaged at a scintillator after passing through a pinhole. The pixelated, 160-mm square scintillator is made up of ¼ mm diameter rods 50 mm long. Shielding and distance (28 m) are used to preserve the recording diagnostic hardware. Neutron imaging is light starved. We designed a large nine-element collecting lens to relay as much scintillator light as reasonable onto a 75 mm gated microchannel plate (MCP) intensifier. The image from the intensifier’s phosphor passes through a fiber taper onto a CCD camera for digital storage. Alignment of the pinhole and tilting of the scintillator is performed before the relay lens and MCP can be aligned. Careful tilting of the scintillator is done so that each neutron only passes through one rod (no crosstalk allowed). The 3.2 ns decay time scintillator emits light in the deep blue, requiring special glass materials. The glass within the lens housing weighs 26 lbs, with the largest element being 7.7 inches in diameter. The distance between the scintillator and the MCP is only 27 inches. The scintillator emits light with 0.56 NA and the lens collects light at 0.15 NA. Thus, the MCP collects only 7% of the available light. Baffling the stray light is a major concern in the design of the optics. Glass cost considerations, tolerancing, and alignment of this lens system will be discussed.

47 OTHER INSTRUMENTATION↗

Fast Scanning Diamond Detector for Electron Beam Profile Monitoring

The first prototype of a fast scanning diamond beam profile detector (DBPD) suitable for invasive high power CW electron beam core profile measurements in transmittance mode was developed. It consists of a multi-strip solid state diamond detector to scan with high speed (up to 1 m/s) and precision (about 5 μm) through the core of an electron beam. The diamond sensor was made from a thin polycrystalline diamond (PCD) plate with highly B-doped diamond conductive strips both grown by CVD. Transient currents from the multi-strip detector were measured with fast digitizing electrometers. Successful operation of the DBPD was demonstrated for pulsed (5 Hz) and CW (78 kHz) CeC beams, including the detector’s ability to withstand a 20 sec insertion into the CW CeC beam core. The X-Y beam spatial profile was measured in one scan. Thermal modelling demonstrated a manageable thermal impact even from a relatively long insertion of the diamond sensor into the CW CeC core and very short (0.2 s) insertion into the CW LEReC beam core. Electrical impedance modelling of the detector and vacuum chamber assembly demonstrated minimal impact on beam line impedance with diamond sensor insertion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗