Molten salt-loop development acceleration with distributed single-crystal harsh-environment optical fiber-sensors
This presentation covers development of single crystal fibers and distributed temperature sensing system given at the NRC workshop.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This presentation covers development of single crystal fibers and distributed temperature sensing system given at the NRC workshop.
Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion sensor was also tested in soil at > 1 foot depth. Fe-coated OFS was loaded into a Draka cable, which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil (50/50).
Understanding fracture propagation behavior is essential for optimizing hydraulic fracturing in unconventional reservoirs. This study demonstrates the value of integrating Low-Frequency Distributed Acoustic Sensing (LF-DAS) and microseismic data, which together provide a more complete picture of fracture growth. Using data from Hydraulic Fracturing Test Site 2 (HFTS2), we identify stress changes in depletion zones induced by parent wells as a key factor influencing fracture propagation. This result is shown by new measurements of in-situ fracture propagation velocity and fracture-hit volume (fluid volume at fracture hit?) from LF-DAS and event density from microseismic. These findings highlight the importance of considering parent well effects, well spacing, and stimulation sequencing in completion design to improve reservoir development and production efficiency.
On 18 October 2023 a 16.3-ton TNT equivalent chemical explosion was detonated underground at the Nevada National Security Site, generating a seismic event (Meyers et al., 2024). The associated seismic wavefield was measured on a Distributed Acoustic Sensing (DAS) array with slant range distances from 27 m – 1123 m. The first arriving phase traveled at an apparent velocity of about 2640 m s -1 from 27 m to 420 m slant range and about 2470 m s -1 from 505 m to 1123 m slant range according to the first arrival moveouts on the DAS data. The first arrival from the explosion temporarily saturated the cable from a slant range of 27 m – 186 m and 0.009 s to 0.084 s post detonation. From 186 m slant range to 420 m slant range, peak strain rates of 5.6 x 10 6 nm m -1 s -1 were observed for the first arrival phase. For the first arrival from 505 m slant range to 1123 m slant range, peak strain rates reduced to 8.0 x 10 4 nm m -1 s -1 . A comparison of the scaled accelerations computed from DAS, the geophone pairs, and the measurements of co-located accelerometer pairs show common agreement at the scaled ranges of the single point sensors. This study adds to the body of work reporting near-source DAS observations of the seismic wavefields generated by underground chemical explosions. These results indicate that near-source DAS observations can refine interpretations of phase identification from single-point sensor observations. Phase identification could be one mechanism that contributes scatter to single point seismic measurements which would confound the performance of empirical relationships for small explosions. Removing that mechanism may therefore reduce interstation variability and increase empirical relationship performance for small explosions.
On 18 October 2023 a 16.3-ton TNT equivalent chemical explosion was detonated underground at the Nevada National Security Site, generating a seismic event with a magnitude of 1.7 (Meyers et al., 2024). The associated seismic wavefield was measured on a Distributed Acoustic Sensing (DAS) array with slant range distances from 27 m – 1123 m. The first arriving phase traveled at an apparent velocity of about 2640 m s -1 from 27 m to 420 m slant range and about 2470 m s -1 from 505 m to 1123 m slant range according to the first arrival moveouts on the DAS data. The first arrival from the explosion temporarily saturated the cable from a slant range of 27 m – 186 m and 0.009 s to 0.084 s post detonation. From 186 m slant range to 420 m slant range, peak strain rates of 5.6 x 10 6 nm m -1 s -1 were observed for the first arrival phase. For the first arrival from 505 m slant range to 1123 m slant range, peak strain rates reduced to 8.0 x 104 nm m -1 s -1 . A comparison of the scaled accelerations computed from DAS, the geophone pairs, and the measurements of co-located accelerometer pairs show common agreement at the scaled ranges of the single point sensors. This study adds to the body of work reporting near-source DAS observations of the seismic wavefields generated by underground chemical explosions. These results indicate that near-source DAS observations can refine interpretations of phase identification from single-point sensor observations. Phase identification could be one mechanism that contributes scatter to single point seismic measurements which would confound the performance of empirical relationships for small explosions. Removing that mechanism may therefore reduce interstation variability and increase empirical relationship performance for small explosions.
This mid-year report summarizes ongoing work to identify anomalous vibration signals indicative of potential containment breaches. This work includes compiling continuous seismic datasets and testing and refining underground detection and geolocation techniques. In the first two quarters of FY25, we have completed two project work plan tasks: (1) creating a database of continuous waveforms and ground truth event data from multiple modalities and (2) refining and implementing a detection and association algorithm to create a catalog of anomalous underground activities. This report contains a summary of the seismic database including the continuous seismic data collected by a dense array of surface seismic stations above Pleasant Gap Mine, and continuous seismic data collected using subsurface distributed acoustic sensing (DAS) in the subsurface at Sanford Underground Research Facility (SURF) and the ground truth information gathered from both sites. This report also includes results from refining and applying a dynamic power spectral density detector to both continuous seismic datasets. Finally, the report provides an initial catalog of subsurface operational events from both sensing modalities.
Distributed Acoustic Sensing (DAS) can record acoustic wavefields at high sampling rates and with dense spatial resolution difficult to achieve with seismometers. Using optical scattering induced by cable deformation, DAS can record strain fields with spatial resolution of a few meters. However, many experiments utilizing DAS have relied on unused, dark telecommunication fibers. As a result, the geophysical community has not fully explored DAS survey parameters to characterize the ideal array design. This limits our understanding of guiding principles in array design to deploy DAS effectively and efficiently in the field. A better quantitative understanding of DAS array behavior can improve the quality of the data recorded by guiding the DAS array design. Here we use steered response functions, which account for DAS fiber’s directional sensitivity, as well as beamforming and back-projection results from forward modelling calculations to assess the performance of varying DAS array geometries to record regional and local sources. A regular heptagon DAS array demonstrated improved capabilities for recording regional sources over other polygonal arrays, with potential improvements in recording and locating local sources. These results help reveal DAS array performance as a function of geometry and can guide future DAS deployments.
Sample return capsules (SRCs) entering Earth's atmosphere at hypervelocity from interplanetary space are a valuable resource for studying meteor phenomena. The 2023 September 24 arrival of the Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer SRC provided an unprecedented chance for geophysical observations of a well-characterized source with known parameters, including timing and trajectory. A collaborative effort involving researchers from 16 institutions executed a carefully planned geophysical observational campaign at strategically chosen locations, deploying over 400 ground-based sensors encompassing infrasound, seismic, distributed acoustic sensing, and Global Positioning System technologies. Additionally, balloons equipped with infrasound sensors were launched to capture signals at higher altitudes. This campaign (the largest of its kind so far) yielded a wealth of invaluable data anticipated to fuel scientific inquiry for years to come. The success of the observational campaign is evidenced by the near-universal detection of signals across instruments, both proximal and distal. This paper presents a comprehensive overview of the collective scientific effort, field deployment, and preliminary findings. The early findings have the potential to inform future space missions and terrestrial campaigns, contributing to our understanding of meteoroid interactions with planetary atmospheres. Furthermore, the data set collected during this campaign will improve entry and propagation models and augment the study of atmospheric dynamics and shock phenomena generated by meteoroids and similar sources.
Distributed temperature sensing data collected using a Silixa-XT DTS and 50/125 MM fiber. Data are calibrated using two water baths at the surface and an iMet aloft at the end of the fiber and tether. The data are then assigned an altitude for the TBS flight.
An injection stimulation test begun at the Raft River geothermal reservoir in June, 2013 has produced a wealth of data describing well and reservoir response via high-resolution temperature logging and distributed temperature sensing, seismic monitoring, periodic borehole televiewer logging, periodic stepped flow rate tests and tracer injections before and after stimulation efforts. One of the primary measures of response to the stimulation is the relationship between fluid pressure and flow rate, short-term during forced flow rate changes and the long-term change in injectivity. In this paper we examine that hydraulic response using standard pumping test analysis methods, largely because pressure response to the stimulation was not detected, or measurable, in other wells. Analysis of stepped rate flow tests supports the inference from other data that a large fracture, with a radial extent of one to several meters, intersects the well in the target reservoir, suggests that the flow regime is radial to a distance of only several meters and demonstrates that the pressure build-up cone reaches an effective constant head at that distance. The well’s longer term hydraulic response demonstrated continually increasing injectivity but at a dramatically faster rate later from ~2 years out and continuing to the present. The net change in injectivity is significantly greater than observed in other longterm injectivity monitoring studies, with an approximately 150–fold increase occurring over ~2.5 years. While gradually increasing injectivity is a likely consequence of slow migration of a cooling front, and consequent dilation of fractures, the steady, ongoing, rate of increase is contrary to what would be expected in a radial or linear flow regime, where the cooling front would slow with time. As a result, occasional step-like changes in injectivity, immediately following high-flow rate tests suggest that hydro shearing during high-pressure testing altered the near-well permeability structure.
Using internal investment funds within Sandia National Laboratories’ (SNL) Division 6000, the Joint UAS-Balloon Activity (JUBA) was a collaborative exercise between SNL Organizations 6533 and 6913 (later 8863) to demonstrate simultaneous flights of tethered balloons and unmanned aerial systems (UAS) on the North Slope of Alaska. JUBA UAS and tethered balloon flights were conducted within the Restricted Airspace associated with the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility third ARM Mobile Facility (AMF3) site at Oliktok Point, Alaska. The Restricted Airspace occupies a two-nautical-mile radius around Oliktok Point. JUBA was conducted at the Sandia Arctic Site, which is approximately 2 km east-southeast of the AMF3. JUBA activities occurred from 08/08/17 and 08/10/17. Atmospheric measurements from tethered balloons can occur for a long duration, but offer limited spatial variation. Measurements from UAS could offer increased spatial variability. To understand how balloon and UAS activities could occur together, JUBA activities included the following: Developing aviation safety plans for the simultaneous, collocated operation of tethered balloons and UAS Adapting tethered balloon-based fiber optic distributed temperature sensing (DTS) measurements to a UAS platform Creating solutions to technical challenges such as: Developing a motor system to match the fiber deployment rate with the ascent/descent rate of the UAS Evaluating methods of identifying the surface in the DTS temperature profile Correlating simultaneous balloon and UAS DTS temperature measurements Assessing the effects of a fiber optic rotary joint on the DTS temperature measurements Determining what UAS-based sensors provided the best calibration source for the DTS temperature data.
The Geothermal Data Repository (GDR) provides universal access to data and information resulting from research and development activities funded by the Department of Energy (DOE). The GDR has extended this universal access to big data through integration with data lakes developed by the Open Energy Data Initiative (OEDI). Previously, large datasets such as seismic waveform or distributed acoustic sensing (DAS) data could only be accessed by institutions with high performance data storage and compute capabilities, effectively limiting the accessibility of big data to national labs, larger universities, and major corporations. Moreover, the time and resources needed to transport big data and configure them can produce additional barriers to use. Many of the standard formats used for structured data models (also known as content models) are incapable of handling big data and can introduce additional usability problems, often requiring data to be reformatted prior to use. This paper will explore how recent integrations between the GDR and the OEDI data lake have improved the accessibility and usability of geothermal data in a big way, making the data available to a broader audience, and enabling collaborative analysis and innovation across the greater geothermal industry.
Long-term seismic monitoring of carbon capture and storage projects (CCS) is needed to verify that the injected gas is safely stored in the subsurface until permanence can be assured. Conventional surface seismic monitoring techniques are usually expensive, require highly invasive surface operations, and need significant time investments on the part of personnel for both the field effort and processing the acquired data. For these reasons, permanent reservoir monitoring (PRM) technologies are preferred, as they can offer a cost-effective solution for long-term monitoring. In this context, we have developed and trialed the use of distributed acoustic sensing (DAS) coupled to permanent rotary sources, called surface orbital vibrators (SOV), with the objective to build a continuous monitoring array for CCS projects.
The Geothermal Data Repository (GDR) provides universal access to data and information resulting from research and development activities funded by the Department of Energy (DOE). The GDR has extended this universal access to big data through integration with data lakes developed by the Open Energy Data Initiative (OEDI). Previously, large datasets such as seismic waveform or distributed acoustic sensing (DAS) data could only be accessed by institutions with high performance data storage and compute capabilities, effectively limiting the accessibility of big data to national labs, larger universities, and major corporations. Moreover, the time and resources needed to transport big data and configure them can produce additional barriers to use. Many of the standard formats used for structured data models (also known as content models) are incapable of handling big data and can introduce additional usability problems, often requiring data to be reformatted prior to use. This paper will explore how recent integrations between the GDR and the OEDI data lake have improved the accessibility and usability of geothermal data in a big way, making the data available to a broader audience, and enabling collaborative analysis and innovation across the greater geothermal industry.
In this work, we discuss the implementation of evanescent field optical fiber sensors for distributed gas sensing of H2, focusing on results using a Ni / Gd-doped CeO2 nanocomposite sensing material for detection of low levels of H2 (0-4%) at 700 °C. This approach utilizes sensors prepared using a low-cost, wet chemical deposition process, in conjunction with a custom-built interrogator system leveraging optical time domain reflectometry (OTDR). Using a specially designed dual-gas flow reactor system, the sensor is tested by establishing a controlled equilibrium gradient of gas concentration. Initial results are shown using silica fiber, but provides a pathway for utilization with high temperature stable single crystal optical fiber for operation at higher temperatures and higher levels of H2 relevant for solid oxide fuel cell (SOFC) operating conditions.
In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Previous tests using metal oxide-based coatings (TiO2) provided strong responses at elevated temperatures and moderate pressure stability but provided poor differentiation between acidic and alkaline solutions. Building off the pH responsiveness of the TiO2 surface and known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. As the polymer itself is highly water soluble and easily removed by aqueous solutions, the sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1,000 psi) and temperatures (80 °C).
The growing adoption of distributed energy resources (DERs) like battery energy storage systems and roof top solar/PV and the rapid penetration of electric vehicles (EVs), the electric grid is undergoing a major transformation with elevated stress on legacy grid assets. Despite a lot of expenditure to address these challenges, both in dollars and manpower, utilities have not been able to receive the value that was promised. The gains have been most visible at the transmission and substation level, especially where the main objective was improving operational and economic efficiency for the utility. Improving visibility and control at a few select points enhances the existing and established paradigm of centralized command and control. With changing load patterns, load types and the overall transition to an “active grid”, the centralized control and coordination paradigm gets challenged. To address the challenges, a new architecture and mechanism is needed, one that supports decentralized control and decision making, extracting value streams at the grid edge, particularly as the changes are fueled by transitions occurring in the distribution system. To address this, a communications and data processing platform, “GAMMA” was developed and demonstrated through the project. At the heart of the platform, are distributed, intelligent edge nodes with sensing and compute capabilities, that can record and analyze information locally. They are embedded in sensors and actuators specific to different distribution system applications. Phase 1 of the project focused on developing novel sensor technology that can be used for monitoring utility pole top distribution transformers. The sensors were designed with the objective of being low-cost, communicating with the GAMMA cloud using novel “delay-tolerant” networking using Bluetooth and a secure mobile application. They were non-intrusive in nature so that they can be installed quickly in the field, resulting in overall low cost of deployment and operations. Following the successful completion of Phase 1, the team manufactured 100 units for a field demonstration in Phase 2. The field demonstration was carried out on two real feeder systems with the local utility partner. In total, 100 sensors were installed and operated over a period of 6 months in the state of Georgia. The platform is operational end to end, with the cloud infrastructure deployed on a distributed, serverless environment that can serve multiple data streams, an analytics engine and a portal to securely view the data from multiple assets. The data collected through the GAMMA Mobile Phone app showcased the viability of the novel delay tolerant networking architecture, and the data processing algorithms developed through the course of the project, were successful in extracting important information about the overall network, improving the utility’s visibility and situational awareness in the distribution feeder.
Distributed fiber optic sensing was an important part of the monitoring system for EGS Collab Experiment #2. A single loop of custom fiber package was grouted into the four monitoring boreholes that bracketed the experiment volume. This fiber package contained two multi-mode fibers and four single-mode fibers. These fibers were connected to an array of fiber optic interrogator units, each targeting a different measurement. The distributed temperature system (DTS) consisted of a Silixa XT-DTS unit, connected to both ends of one of the two multi-mode fibers. This system measured absolute temperature along the entire length of fiber for the duration of the experiment at a sampling rate of approximately 10 minutes. This dataset includes both raw data in XML format from the XT-DTS, as well as a processed dataset with the sections of data pertaining only to the boreholes are extracted. We have also included a report that provides all of the relevant details necessary for users to process and interpret the data for themselves. Please read this accompanying report. If, after reading it, there are still outstanding questions, please do not hesitate to contact us. Happy processing.