Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic active volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of hydrogen sensor performance are being developed. Various commercial sensor platforms (e.g., thermal conductivity, catalytic and metal semiconductor) were used to demonstrate the advantages and issues with the flow through methodology.

14 SOLAR ENERGY↗

OBSERVING THE FINE STRUCTURE OF LOOPS THROUGH HIGH-RESOLUTION SPECTROSCOPIC OBSERVATIONS OF CORONAL RAIN WITH THE CRISP INSTRUMENT AT THE SWEDISH SOLAR TELESCOPE

Observed in cool chromospheric lines, such as H{alpha} or Ca II H, coronal rain corresponds to cool and dense plasma falling from coronal heights. Considered as a peculiar sporadic phenomenon of active regions, it has not received much attention since its discovery more than 40 years ago. Yet, it has been shown recently that a close relationship exists between this phenomenon and the coronal heating mechanism. Indeed, numerical simulations have shown that this phenomenon is most likely due to a loss of thermal equilibrium ensuing from a heating mechanism acting mostly toward the footpoints of loops. We present here one of the first high-resolution spectroscopic observations of coronal rain, performed with the CRisp Imaging Spectro Polarimeter (CRISP) instrument at the Swedish Solar Telescope. This work constitutes the first attempt to assess the importance of coronal rain in the understanding of the coronal magnetic field in active regions. With the present resolution, coronal rain is observed to literally invade the entire field of view. A large statistical set is obtained in which dynamics (total velocities and accelerations), shapes (lengths and widths), trajectories (angles of fall of the blobs), and thermodynamic properties (temperatures) of the condensations are derived. Specifically, we find that coronal rain is composed of small and dense chromospheric cores with average widths and lengths of {approx}310 km and {approx}710 km, respectively, average temperatures below 7000 K, displaying a broad distribution of falling speeds with an average of {approx}70 km s{sup -1}, and accelerations largely below the effective gravity along loops. Through estimates of the ion-neutral coupling in the blobs we show that coronal rain acts as a tracer of the coronal magnetic field, thus supporting the multi-strand loop scenario, and acts as a probe of the local thermodynamic conditions in loops. We further elucidate its potential in coronal heating. We find that the cooling in neighboring strands occurs simultaneously in general suggesting a similar thermodynamic evolution among strands, which can be explained by a common footpoint heating process. Constraints for coronal heating models of loops are thus provided. Estimates of the fraction of coronal volume with coronal rain give values between 7% and 30%. Estimates of the occurrence time of the phenomenon in loops set times between 5 and 20 hr, implying that coronal rain may be a common phenomenon, in agreement with the frequent observations of cool downflows in extreme-ultraviolet lines. The coronal mass drain rate in the form of coronal rain is estimated to be on the order of 5 Multiplication-Sign 10{sup 9} g s{sup -1}, a significant quantity compared to the estimate of mass flux into the corona from spicules.

79 ASTRONOMY AND ASTROPHYSICS↗

In-vivo Raman microspectroscopy reveals differential nitrate concentration in different developmental zones in Arabidopsis roots

Abstract Background Nitrate (NO 3 − ) is one of the two major forms of inorganic nitrogen absorbed by plant roots, and the tissue nitrate concentration in roots is considered important for optimizing developmental programs. Technologies to quantify the expression levels of nitrate transporters and assimilating enzymes at the cellular level have improved drastically in the past decade. However, a technological gap remains for detecting nitrate at a high spatial resolution. Using extraction-based methods, it is challenging to reliably estimate nitrate concentration from a small volume of cells (i.e., with high spatial resolution), since targeting a small or specific group of cells is physically difficult. Alternatively, nitrate detection with microelectrodes offers subcellular resolution with high cell specificity, but this method has some limitations on cell accessibility and detection speed. Finally, optical nitrate biosensors have very good ( in-vivo ) sensitivity (below 1 mM) and cellular-level spatial resolution, but require plant transformation, limiting their applicability. In this work, we apply Raman microspectroscopy for high-dynamic range in-vivo mapping of nitrate in different developmental zones of Arabidopsis thaliana roots in-situ . Results As a proof of concept, we have used Raman microspectroscopy for in-vivo mapping of nitrate content in roots of Arabidopsis seedlings grown on agar media with different nitrate concentrations. Our results revealed that the root nitrate concentration increases gradually from the meristematic zone (~ 250 µm from the root cap) to the maturation zone (~ 3 mm from the root cap) in roots grown under typical growth conditions used for Arabidopsis, a trend that has not been previously reported. This trend was observed for plants grown in agar media with different nitrate concentrations (0.5–10 mM). These results were validated through destructive measurement of nitrate concentration. Conclusions We present a methodology based on Raman microspectroscopy for in-vivo label-free mapping of nitrate within small root tissue volumes in Arabidopsis. Measurements are done in-situ without additional sample preparation. Our measurements revealed nitrate concentration changes from lower to higher concentration from tip to mature root tissue. Accumulation of nitrate in the maturation zone tissue shows a saturation behavior. The presented Raman-based approach allows for in-situ non-destructive measurements of Raman-active compounds.

Fernández González, Alma↗

Dual Fan Separator within the Universal Waste Management System

Since NASA's new spacecraft in development for both LEO and Deep Space capability have considerable crew volume reduction in comparison to the Space Shuttle, it is clear that NASA requires a smaller and less expensive commode. The UTAS Universal Waste Management System (UWMS) was designed to address these new constraints, resulting in an 80% volume reduction in the cabin while enhancing performance. Whereas all of the current space commodes use air flow to capture both urine and feces and separate air from the captured air/urine mixture, the UWMS commode and urine fans and the urine separator were combined into a single unit. This unit enables use of a single motor and motor controller, which provides considerable packaging and weight efficiency. In some of the intended platform applications for the UWMS, the urine is pumped to a water reclamation system. The ISS Urine Processor Assembly (UPA) system requires delivered urine to include less than 0.25% air inclusion. Air inclusion in centrifugal urine separators is greatly dependent on its rotational speed. To satisfy this requirement, a gear reducer was included, allowing the fans to rotate at a much higher speed than the separator. This new design, the Dual Fan Separator (DFS) has been designed, prototyped and tested. This paper will outline the studies and analysis performed to develop the design configuration for testing. The studies included a configuration trade study, dynamic stability analysis of the rotating bodies and a performance analysis of included labyrinth seals. NASA is considereing a program to fly the UWMS aboard the ISS as a flight experiment. The goal of the design activity is to elevate the Technical Readiness Level (TRL) of the Dual Fan Separator and determine if the concept is ready to be included in flight experiment deliverable.

Stapleton, Tom↗

Modeling Antarctic Subglacial Lake Filling and Drainage Cycles

The growth and drainage of active subglacial lakes in Antarctica has previously been inferred from analysis of ice surface altimetry data. We use a subglacial hydrology model applied to a synthetic Antarctic ice stream to examine internal controls on the filling and drainage of subglacial lakes. Our model outputs suggest that the highly constricted subglacial environment of our idealized ice stream, combined with relatively high rates of water flow funneled from a large catchment, can combine to create a system exhibiting slow-moving pressure waves. Over a period of years, the accumulation of water in the ice stream onset region results in a buildup of pressure creating temporary channels, which then evacuate the excess water. This increased flux of water beneath the ice stream drives lake growth. As the water body builds up, it steepens the hydraulic gradient out of the overdeepened lake basin and allows greater flux. Eventually this flux is large enough to melt channels that cause the lake to drain. Lake drainage also depends on the internal hydrological development in the wider system and therefore does not directly correspond to a particular water volume or depth. This creates a highly temporally and spatially variable system, which is of interest for assessing the importance of subglacial lakes in ice stream hydrology and dynamics.

drainage↗

NASA's Solar Dynamics Observatory (SDO): A Systems Approach to a Complex Mission

The Solar Dynamics Observatory (SDO) includes three advanced instruments, massive science data volume, stringent science data completeness requirements, and a custom ground station to meet mission demands. The strict instrument science requirements imposed a number of challenging drivers on the overall mission system design, leading the SDO team to adopt an integrated systems engineering presence across all aspects of the mission to ensure that mission science requirements would be met. Key strategies were devised to address these system level drivers and mitigate identified threats to mission success. The global systems engineering team approach ensured that key drivers and risk areas were rigorously addressed through all phases of the mission, leading to the successful SDO launch and on-orbit operation. Since launch, SDO's on-orbit performance has met all mission science requirements and enabled groundbreaking science observations, expanding our understanding of the Sun and its dynamic processes.

systems engineering↗

The effect of CO 2 -induced dissolution on flow properties in Indiana Limestone: An in situ synchrotron X-ray micro-tomography study

The injection of CO 2 -rich fluids in carbonate rocks results in an evolution of the pore space, with consequent changes in the hydraulic properties of the reservoir; how these properties evolve, particularly for parameters relevant to multiphase flow e.g. P c (s), remains a topic of active research despite several decades of study. We have carried out an in situ synchrotron X-ray microtomography experiment to monitor pore structure evolution during dissolution of an Indiana Limestone core; the experiment involved flowing CO 2 -saturated water through the core for 36 h and resulted in 10 volumes corresponding to different temporal stages of the dissolution process. The injection parameters corresponded to the flow velocities expected near the well-bore region of a shallow aqueous CO 2 injection; fast flow rates with high reactant availability. Analysis of the tomographic data shows flow-enhanced dissolution i.e. channeling, and provides a time-resolved map of pore space alteration. Using the resulting 4D pore space volume, we modeled the evolution of capillary-pressure curves; this exercise demonstrates how pore structure evolution could impact the invasion and remobilization of non-wetting fluids, dramatically decreasing the entry pressure and the P C in some parts of the sample. The modeling of permeability, using a Stokes solver approach, quantified the relationship of porosity vs. permeability; we found that a modest increase in porosity, especially when the channeling system is more developed, greatly affects permeability. Furthermore, these results demonstrate how movement of CO 2 saturated brine near injected plumes might alter drainage dynamics near the plume boundary, thus leading to mobilization across subtle capillary barriers.

58 GEOSCIENCES↗

DISCOVERY OF A FAINT COMPANION TO ALCOR USING MMT/AO 5 {mu}m IMAGING

We report the detection of a faint stellar companion to the famous nearby A5V star Alcor (80 UMa). The companion has M-band ({lambda} = 4.8 {mu}m) magnitude 8.8 and projected separation 1.''11 (28 AU) from Alcor. The companion is most likely a low-mass ({approx}0.3 M {sub sun}) active star which is responsible for Alcor's X-ray emission detected by ROSAT (L {sub X} {approx_equal} 10{sup 28.3} erg s{sup -1}). Alcor is a nuclear member of the Ursa Major star cluster (UMa; d {approx_equal} 25 pc, age {approx_equal} 0.5 Gyr), and has been occasionally mentioned as a possible distant (709'') companion of the stellar quadruple Mizar ({zeta} UMa). Comparing the revised Hipparcos proper motion for Alcor with the mean motion for other UMa nuclear members shows that Alcor has a peculiar velocity of 1.1 km s{sup -1}, which is comparable to the predicted velocity amplitude induced by the newly discovered companion ({approx}1 km s{sup -1}). Using a precise dynamical parallax for Mizar and the revised Hipparcos parallax for Alcor, we find that Mizar and Alcor are physically separated by 0.36 {+-} 0.19 pc (74 {+-} 39 kAU; minimum 18 kAU), and their velocity vectors are marginally consistent ({chi}{sup 2} probability 6%). Given their close proximity and concordant motions we suggest that the Mizar quadruple and the Alcor binary be together considered the second closest stellar sextuplet. The addition of Mizar-Alcor to the census of stellar multiples with six or more components effectively doubles the local density of such systems within the local volume (d < 40 pc)

79 ASTRONOMY AND ASTROPHYSICS↗

UAS Related Activities at NASA's Dryden Flight Research Center

NASA's Dryden Flight Research Center is completing its refurbishment and initial flights of one the pre-production Global Hawk aircraft it received from the U.S. Air Force. NASA Dryden has an agreement with the Global Hawk s manufacturer, Northrop Grumman, to partner in the refurbishment and flight operations of the vehicles. The National Oceanic and Atmospheric Administration (NOAA) has also partnered on the project and is assisting NASA with project management and pilot responsibilities for the aircraft. NASA and NOAA will be using the Global Hawks to conduct earth science research. The earth science community is increasing utilizing UAS of all sizes and capabilities to collect important data on a variety of issues including important global climate change issues. To pursue the data collection needs of the science community there is a growing demand for international collaboration with respect to operating UAS in global airspace. Operations of NASA s Ikhana aircraft continued this past year. The Ikhana is a modified Predator B UAS. A UAS dedicated to research at NASA Dryden is the X-48B blended wing body research aircraft. Flight tests with the 500- pound, remotely piloted test vehicle are now in a block 4 phase involving parameter identification and maneuvers to research the limits of the engine in stall situations. NASA s participation in the blended wing body research effort is focused on fundamental, advanced flight dynamics and structural design concepts within the Subsonic Fixed Wing project, part of the Fundamental Aeronautics program managed through NASA s Aeronautics Research Mission Directorate. Potential benefits of the aircraft include increased volume for carrying capacity, efficient aerodynamics for reduced fuel burn and possibly significant reductions in noise due to propulsion integration options. NASA Dryden continues to support the UAS industry by facilitating access to three specially designated test areas on Edwards Air Force Base for the development of small UAS.

Bauer, Jeffrey E.↗

Porous and Amorphous Mn x Mo 3 S 13 Chalcogel Electrode for High-Capacity Conversion-Based Lithium-Ion Batteries

While Li-ion batteries (LIBs) are a leading energy storage technology, their energy densities are limited by the low capacity of conventional intercalation cathodes, driving interest in high energy-density Li–S batteries that make use of conversion chemistry. Achieving high capacity, reversibility, and cycle stability, and controlling volume changes in conversion batteries during the charge–discharge process, however, remains challenging. Here, in this study, we present a porous, amorphous, sulfide-based Mn x Mo 3 S 13 chalcogel, which concurrently offers high capacity and cycle stability. The solution-processable room temperature synthesized Mn x Mo 3 S 13 (x = 0.25) chalcogel exhibits a local structure that resembles the Mo 3 S 13 cluster with Mn 2+ distributed across the Mo 3 S 13 matrix, as determined by synchrotron X-ray pair distribution function (PDF) and extended X-ray absorption fine structure (EXAFS). Ab initio molecular dynamics (AIMD) simulations reveal that Mn 2+ incorporation shortens the polysulfide chain in the gel matrix compared to the Mo 3 S 13 chalcogel, while forming a coordination environment with disulfide groups, analogous to the experimental findings. A Li/Mn 0.25 Mo 3 S 13 half-cell delivers 897 mAh g –1 capacity during the first discharge and retains 571 mAh g –1 capacity after 100 cycles at a C/3 rate. Distribution of relaxation time (DRT) unveils a stable solid–electrolyte interphase (SEI) formation upon cycling that enables charge–discharge reversibility. Here, the enhanced capacity retention and cycle stability compared to those of the Li/Mo 3 S 13 cell are attributed to the reduced dissolution of active mass into the electrolyte, facilitated by the formation of shorter polysulfide chains within the Mn 0.25 Mo 3 S 13 structure and the strong affinity of Lewis-acidic Mn 2+ for polysulfide anions generated during the charge–discharge process of the Li/Mn 0.25 Mo 3 S 13 cell. Thus, this work illustrates a design principle of material for high-capacity and cycle-stable Li-metal sulfide batteries.

25 ENERGY STORAGE↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

Cleanup under Airlock of an Old Uranium Foundry - 13273

Since 2004, AREVA's subsidiary SICN has been conducting the cleanup and dismantling of an old uranium foundry located in the town of Annecy (France). The first operations consisted in the removal of the foundry's production equipment, producing more than 300 metric tons (MT) of waste. The second step consisted in performing the radiological characterization of the 1,600 m{sup 2} (17,200 ft{sup 2}) building, including underground trenches and galleries. The building was precisely inventoried, based on operations records and direct measurements. All sub-surfaces, which needed to be cleaned up were characterized, and a determination of the contamination migration was established, in particular with trenches and galleries. The wall thicknesses to be treated were empirically justified, knowing that the maximal migration depth inside concrete is 5 mm for a liquid transfer vector. All singularities such as cracks, anchoring points, etc. were spotted for a complete and systematic treatment. Building structures not laying directly on the soil, such as floor slabs, were not cleaned up but directly deconstructed and disposed of as waste. The facility was located within the town of Annecy. Therefore, in order to avoid the risk of dusts dispersion and public exposure during the building deconstruction and the soil treatment, a third of the building's surface was confined in a sliding airlock built from a metal structure capable of resisting to wind and snow, which are frequent in this area. This particular structure provided a static confinement over the half of the building which was covered and a dynamic confinement using a ventilation and high efficiency air filtration system, sized to provide 2.5 air changes per hour. The enclosure and its metallic structure is 33 m long (108 feet), 25 m wide (82 feet), and 13 m high (42 feet), for a volume of 10,000 m{sup 3} (353,000 ft{sup 3}). It was made up of a double skin envelope, allowing the recycling of its structure and outside envelope. After cleaning up and dismantling the first portion of the building, the enclosure was repositioned on the second and the last third of the building, by sliding it on support pads. Almost 7,000 m{sup 2} of concrete surface has been treated with no dust dispersion outside the enclosure. After treatment, all the remaining surfaces were controlled by an independent entity to verify their acceptability with regards to residual contamination (less than 0.4 Bq/cm{sup 2} (24 DPM) for alpha contamination and less than 1 Bq/g of total uranium). Approximately 1,900 MT of equipment and waste were generated in batches of 1m{sup 3}, in order to be staged on site, and then characterized and packaged in 20 foot containers for shipment to the final ANDRA repository. The package certification included the verification of the physical and chemical characteristics and the radiological characteristics (mass activity, dose rate, and residual outside surface contamination). Finally, after cleanup and dismantling of the foundry, a concrete slab was poured on the free surface as a clean base for implementation of new activities. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overview of the Cumulus Humilis Aerosol Processing Study

The primary goal of the Cumulus Humilis Aerosol Processing Study (CHAPS) was to characterize and contrast freshly emitted aerosols below, above, and within fields of cumuli, and to study changes to the cloud microphysical structure within these same cloud fields. The CHAPS is one of very few studies that have had an Aerosol Mass Spectrometer (AMS) sampling downstream of a counter-flow virtual impactor (CVI) inlet on an aircraft, allowing the examination of the chemical composition of the nucleated aerosols within the cumuli. The results from the CHAPS will provide insights into changes in the aerosol chemical and optical properties as aerosols move through shallow cumuli downwind of a moderately sized city. Three instrument platforms were employed during the CHAPS, including the U.S. Department of Energy Gulfstream-1 aircraft, which was equipped for in situ sampling of aerosol optical and chemical properties; the NASA-Langley King Air B200, which carried the downward looking NASA Langley High Spectral Resolution Lidar (HSRL) to measure profiles of aerosol backscatter, extinction, and depolarization between the King Air and the surface; and a surface site equipped for continuous in situ measurements of aerosol properties, profiles of aerosol backscatter, and meteorological conditions including total sky cover and thermodynamic profiles of the atmosphere. In spite of record precipitation over central Oklahoma, a total of eight research flights were made by the G-1, and eighteen by the B200, including special satellite verification flights timed to coincide with NASA satellite A-Train overpasses.

54 ENVIRONMENTAL SCIENCES↗

Isolation of Resistance-Bearing Microorganisms

To better exploit the principles of gas transport and mass transport during the processes of cell seeding of 3D scaffolds and in vitro culture of 3D tissue engineered constructs, the oscillatory cell culture bioreactor provides a flow of cell suspensions and culture media directly through a porous 3D scaffold (during cell seeding) and a 3D construct (during subsequent cultivation) within a highly gas-permeable closed-loop tube. This design is simple, modular, and flexible, and its component parts are easy to assemble and operate, and are inexpensive. Chamber volume can be very low, but can be easily scaled up. This innovation is well suited to work with different biological specimens, particularly with cells having high oxygen requirements and/or shear sensitivity, and different scaffold structures and dimensions. The closed-loop changer is highly gas permeable to allow efficient gas exchange during the cell seeding/culturing process. A porous scaffold, which may be seeded with cells, is fixed by means of a scaffold holder to the chamber wall with scaffold/construct orientation with respect to the chamber determined by the geometry of the scaffold holder. A fluid, with/without biological specimens, is added to the chamber such that all, or most, of the air is displaced (i.e., with or without an enclosed air bubble). Motion is applied to the chamber within a controlled environment (e.g., oscillatory motion within a humidified 37 C incubator). Movement of the chamber induces relative motion of the scaffold/construct with respect to the fluid. In case the fluid is a cell suspension, cells will come into contact with the scaffold and eventually adhere to it. Alternatively, cells can be seeded on scaffolds by gel entrapment prior to bioreactor cultivation. Subsequently, the oscillatory cell culture bioreactor will provide efficient gas exchange (i.e., of oxygen and carbon dioxide, as required for viability of metabolically active cells) and controlled levels of fluid dynamic shear (i.e., as required for viability of shear-sensitive cells) to the developing engineered tissue construct. This bioreactor was recently utilized to show independent and interactive effects of a growth factor (IGF-I) and slow bidirectional perfusion on the survival, differentiation, and contractile performance of 3D tissue engineering cardiac constructs. The main application of this system is within the tissue engineering industry. The ideal final application is within the automated mass production of tissue- engineered constructs. Target industries could be both life sciences companies as well as bioreactor device producing companies.

Venkateswaran, Kasthuri, J.↗

Oscillating Cell Culture Bioreactor

To better exploit the principles of gas transport and mass transport during the processes of cell seeding of 3D scaffolds and in vitro culture of 3D tissue engineered constructs, the oscillatory cell culture bioreactor provides a flow of cell suspensions and culture media directly through a porous 3D scaffold (during cell seeding) and a 3D construct (during subsequent cultivation) within a highly gas-permeable closed-loop tube. This design is simple, modular, and flexible, and its component parts are easy to assemble and operate, and are inexpensive. Chamber volume can be very low, but can be easily scaled up. This innovation is well suited to work with different biological specimens, particularly with cells having high oxygen requirements and/or shear sensitivity, and different scaffold structures and dimensions. The closed-loop changer is highly gas permeable to allow efficient gas exchange during the cell seeding/culturing process. A porous scaffold, which may be seeded with cells, is fixed by means of a scaffold holder to the chamber wall with scaffold/construct orientation with respect to the chamber determined by the geometry of the scaffold holder. A fluid, with/without biological specimens, is added to the chamber such that all, or most, of the air is displaced (i.e., with or without an enclosed air bubble). Motion is applied to the chamber within a controlled environment (e.g., oscillatory motion within a humidified 37 C incubator). Movement of the chamber induces relative motion of the scaffold/construct with respect to the fluid. In case the fluid is a cell suspension, cells will come into contact with the scaffold and eventually adhere to it. Alternatively, cells can be seeded on scaffolds by gel entrapment prior to bioreactor cultivation. Subsequently, the oscillatory cell culture bioreactor will provide efficient gas exchange (i.e., of oxygen and carbon dioxide, as required for viability of metabolically active cells) and controlled levels of fluid dynamic shear (i.e., as required for viability of shear-sensitive cells) to the developing engineered tissue construct. This bioreactor was recently utilized to show independent and interactive effects of a growth factor (IGF-I) and slow bidirectional perfusion on the survival, differentiation, and contractile performance of 3D tissue engineering cardiac constructs. The main application of this system is within the tissue engineering industry. The ideal final application is within the automated mass production of tissue- engineered constructs. Target industries could be both life sciences companies as well as bioreactor device producing companies.

Freed, Lisa E.↗

Electric Potential and Electric Field Imaging with Dynamic Applications & Extensions

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field made be used for volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. Extensions to environment, Space and subterranean applications will be presented, and initial results for quantitative characterizing material properties are shown. A wearable EFI system has been developed by using fundamental EFI concepts. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, manufacturing quality control, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, weather prediction, earth quake prediction, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

Fluorescence-coupled micropipette aspiration assay to examine calcium mobilization caused by red blood cell mechanosensing

Abstract Mechanical stimuli such as tension, compression, and shear stress play critical roles in the physiological functions of red blood cells (RBCs) and their homeostasis, ATP release, and rheological properties. Intracellular calcium (Ca 2+ ) mobilization reflects RBC mechanosensing as they transverse the complex vasculature. Emerging studies have demonstrated the presence of mechanosensitive Ca 2+ permeable ion channels and their function has been implicated in the regulation of RBC volume and deformability. However, how these mechanoreceptors trigger Ca 2+ influx and subsequent cellular responses are still unclear. Here, we introduce a fluorescence-coupled micropipette aspiration assay to examine RBC mechanosensing at the single-cell level. To achieve a wide range of cell aspirations, we implemented and compared two negative pressure adjusting apparatuses: a homemade water manometer (− 2.94 to 0 mmH 2 O) and a pneumatic high-speed pressure clamp (− 25 to 0 mmHg). To visualize Ca 2+ influx, RBCs were pre-loaded with an intensiometric probe Cal-520 AM, then imaged under a confocal microscope with concurrent bright-field and fluorescent imaging at acquisition rates of 10 frames per second. Remarkably, we observed the related changes in intracellular Ca 2+ levels immediately after aspirating individual RBCs in a pressure-dependent manner. The RBC aspirated by the water manometer only displayed 1.1-fold increase in fluorescence intensity, whereas the RBC aspirated by the pneumatic clamp showed up to threefold increase. These results demonstrated the water manometer as a gentle tool for cell manipulation with minimal pre-activation, while the high-speed pneumatic clamp as a much stronger pressure actuator to examine cell mechanosensing directly. Together, this multimodal platform enables us to precisely control aspiration and membrane tension, and subsequently correlate this with intracellular calcium concentration dynamics in a robust and reproducible manner.

Wang, Haoqing↗

Tracking nanoparticle growth in pulsed carbon arc discharge

The dynamics of nanoparticle growth in pulsed anodic arc discharge has been studied in time-resolved mode. To this end, a fast moving probe was employed to extract the material generated in a pulsed arc plasma held between two graphite electrodes. The probe motion was synchronized with the pulse phase and the exposure time to the plasma was set to 10 ms. The graphite anode was eroded in a helium atmosphere (300 Torr) by an arc plasma pulsed at 1 Hz with a 10% duty cycle and showing 250 A of peak current. The structure and morphology of the probe depositions were characterized by Raman spectroscopy, scanning electron microscopy, and focused ion beam. A maximal deposition rate of 260 μm/s was measured 5 mm away from the arc core during the active 0.1 s of the pulse. Such a rate yields a growth flux of 1.3 × 10 21 cm –2 s –1 , rich in carbon nanostructures (graphene platelets, nanotubes) with a characteristic aggregate size within 1–10 μm. The deposition during the inactive 0.9 s of the pulse was several orders of magnitude slower and consisted of amorphous carbon traces. Furthermore, the nanoparticle distribution along the collecting probe is correlated with the pulse phase, thereby providing information on particle transport. Pulsed nanosynthesis can be modeled as a periodical growth process, where the volume and propagation velocity of the growth region can be adjusted through modulation of the pulse signal waveform. The proposed model constitutes a suitable framework to investigate the pulsed arc synthesis of nanomaterials with tailored physical and chemical properties.

42 ENGINEERING↗