Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Neutron and X-ray Detectors

The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors: Improvements in the readout speed and energy resolution of X-ray detectors are essential to enable chemically sensitive microscopies. Advances would make it possible to take images with simultaneous spatial and chemical information. Very high-energy-resolution X-ray detectors: The energy resolution of semiconductor detectors, while suitable for a wide range of applications, is far less than what can be achieved with X-ray optics. A direct detector that could rival the energy resolution of optics could dramatically improve the efficiency of a multitude of experiments, as experiments are often repeated at a number of different energies. Very high-energy-resolution detectors could make these experiments parallel, rather than serial. Low-background, high-spatial-resolution neutron detectors: Low-background detectors would significantly improve experiments that probe excitations (phonons, spin excitations, rotation, and diffusion in polymers and molecular substances, etc.) in condensed matter. Improved spatial resolution would greatly benefit radiography, tomography, phase-contrast imaging, and holography. Improved acquisition and visualization tools: In the past, with the limited variety of slow detectors, it was straightforward to visualize data as it was being acquired (and adjust experimental conditions accordingly) to create a compact data set that the user could easily transport. As detector complexity and data rates explode, this becomes much more challenging. Three goals were identified as important for coping with the growing data volume from high-speed detectors: Facilitate better algorithm development. In particular, algorithms that can minimize the quantity of data stored. Improve community-driven mechanisms to reduce data protocols and enhance quantitative, interactive visualization tools. Develop and distribute community-developed, detector-specific simulation tools. Aim for parallelization to take advantage of high-performance analysis platforms. Improved analysis work flows: Standardize the format of metadata that accompanies detector data and describes the experimental setup and conditions. Develop a standardized user interface and software framework for analysis and data management. The diversity of detector improvements required is necessarily as broad as the range of scientific experimentation at BES facilities. This workshop identified a variety of avenues by which detector R&D can enable enhanced science at BES facilities. The Research Directions listed above will be addressed by focused R&D and detector engineering, both of which require specialized infrastructure and skills. While U.S. leadership in neutron and X-ray detectors lags behind other countries in several areas, significant talent exists across the complex. A forum of technical experts, facilities management, and BES could be a venue to provide further definition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

Iron transformation pathways and redox micro-environments in seafloor sulfide-mineral deposits: Spatially resolved Fe XAS and δ 57/54 Fe observations

Hydrothermal sulfide chimneys located along the global system of oceanic spreading centers are habitats for microbial life during active venting. Hydrothermally extinct, or inactive, sulfide deposits also host microbial communities at globally distributed sites. The main goal of this study is to describe Fe transformation pathways, through precipitation and oxidation-reduction (redox) reactions, and examine transformation products for signatures of biological activity using Fe mineralogy and stable isotope approaches. The study includes active and inactive sulfides from the East Pacific Rise 9°50'N vent field. First, the mineralogy of Fe(III)-bearing precipitates is investigated using microprobe X-ray absorption spectroscopy (μXAS) and X-ray diffraction (μXRD). Second, laser-ablation (LA) and micro-drilling (MD) are used to obtain spatially-resolved Fe stable isotope analysis by multicollector-inductively coupled plasma-mass spectrometry (MC-ICP-MS). Eight Fe-bearing minerals representing three mineralogical classes are present in the samples: oxyhydroxides, secondary phyllosilicates, and sulfides. For Fe oxyhydroxides within chimney walls and layers of Si-rich material, enrichments in both heavy and light Fe isotopes relative to pyrite are observed, yielding a range of δ 57 Fe values up to 6‰. Overall, several pathways for Fe transformation are observed. Pathway 1 is characterized by precipitation of primary sulfide minerals from Fe(II)aq-rich fluids in zones of mixing between vent fluids and seawater. Pathway 2 is also consistent with zones of mixing but involves precipitation of sulfide minerals from Fe(II)aq generated by Fe(III) reduction. Pathway 3 is direct oxidation of Fe(II) aq from hydrothermal fluids to form Fe(III) precipitates. Finally, Pathway 4 involves oxidative alteration of pre-existing sulfide minerals to form Fe(III). The Fe mineralogy and isotope data do not support or refute a unique biological role in sulfide alteration. The findings reveal a dynamic range of Fe transformation pathways consistent with a continuum of micro-environments having variable redox conditions. Lastly, these micro-environments likely support redox cycling of Fe and S and are consistent with culture-dependent and -independent assessments of microbial physiology and genetic diversity of hydrothermal sulfide deposits.

mineral alteration↗

A fractional calculus framework for open quantum dynamics: From Liouville to Lindblad to memory kernels

Open quantum systems exhibit dynamics ranging from unitary evolution to irreversible dissipation. While the Gorini–Kossakowski–Sudarshan–Lindblad equation uniquely characterizes Markovian completely positive and trace-preserving (CPTP) evolution, many physical platforms display non-Markovian features such as algebraic relaxation and coherence backflow. Fractional calculus provides a natural way to model such long-memory behavior through power-law temporal kernels introduced by fractional time derivatives. Here, we develop a unified framework that embeds fractional master equations within the broader hierarchy of open-system formalisms. The fractional equation forms a structured subclass of memory-kernel models, reduces to the Lindblad form at unit order, and, through Bochner–Phillips subordination, admits a CPTP representation as an average over Lindblad semigroups. Its resolvent structure further connects fractional dynamics to established non-Markovian approaches, including Nakajima–Zwanzig kernels and hierarchical equations of motion, providing a compact surrogate for long-memory effects. This formulation positions fractional calculus as a rigorous and practical language for modeling non-Markovian quantum dynamics in chemical physics and physical chemistry, providing a CPTP-preserving, computationally efficient surrogate for structured condensed-phase environments where long-time memory and dissipation play a central role.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opinion: Lighting Research During and After the Pandemic

For many lighting researchers, the recent restrictions related to COVID-19 have paused most in-person laboratory or field experiments. In certain countries, regulatory institutions have allowed such experiments to resume but issued safety recommendations like pre-checking participants for disease symptoms and excluding those that are especially vulnerable. To avoid potential complications and delays, researchers are likely to resort to other research designs that enable remote research — eliminating the need for the experimenter and subjects to be in the same room. While unanticipated, this shift to remote research methods is an opportunity to revisit and further develop remote experimental techniques, which can have beneficial long-lasting implications on lighting research during and after the pandemic. Perhaps the most common type of remote research is online experiments; which can greatly benefit from improved techniques to allow for greater control or characterization of experimental conditions, like those proposed by Villa and Labayrade . These techniques require validation specific to the type of response collected and context, e.g. space type and attributes. New research techniques continue to emerge and will enable remote collection of objective measures such as gaze direction and high dynamic range images (HDRIs) without specialized equipment. In fact, many of these methods and techniques are commonly used in other disciplines, like vision science and psychology, and can be adapted for lighting research. Not all lighting studies can be conducted online, but in the age of ubiquitous and connected technologies, there is a largely missed opportunity to utilize crowdsourced responses to lighting conditions in real environments where people live and go about their daily lives without the research being limited to a certain time and laboratory locations. For instance, outdoor street luminaires can be rated by passersby using ecological momentary assessments on mobile phones. While this approach does not provide laboratory-level control over experimental conditions, it can provide more contextual responses resulting from ‘normal’ dynamic gaze, behavior, and interactions. Further, it can also reduce bias related to the experimental setting. Further development of remote research methods and their use in lighting research can improve the quality of lighting research. Given that sample sizes in most lighting research are relatively small, remote research can substantially increase sample sizes, reduce research costs, and shorten study duration, all while reducing interaction between experimenter and subjects. Another benefit is reaching a wider audience and including under-represented individuals who typically are not reachable using common recruitment methods. The pandemic has set back our plans for in-lab experiments, but can it inspire us to think of new and creative ways to expand lighting research?

Abboushi, Belal K.↗

High-sensitivity 86 GHz (3.5 mm) VLBI observations of M87: Deep imaging of the jet base at a resolution of 10 Schwarzschild radii

We report on results from new high-sensitivity, high-resolution 86 GHz (3.5 mm) observations of the jet base in the nearby radio galaxy M87, obtained by the Very Long Baseline Array in conjunction with the Green Bank Telescope. The resulting image has a dynamic range exceeding 1500 to 1, the highest ever achieved for this jet at this frequency, resolving and imaging a detailed jet formation/collimation structure down to ∼10 Schwarzschild radii (R{sub s}). The obtained 86 GHz image clearly confirms some important jet features known at lower frequencies, i.e., a jet base with a wide opening angle, a limb-brightened intensity profile, a parabola-shape collimation profile and a counter jet. The limb-brightened structure is already well developed at <0.2 mas (<28 R{sub s}, projected) from the core, where the corresponding apparent opening angle becomes as wide as ∼100°. The subsequent jet collimation near the black hole evolves in a complicated manner; there is a “constricted” structure at tens of R{sub s} from the core, where the jet cross section is locally shrinking. We suggest that external pressure support from the inner part of the radiatively inefficient accretion flow may be dynamically important in shaping/confining the footprint of the magnetized jet. We also present the first 86 GHz polarimetric experiment using very long baseline interferometry for this source, where a highly polarized (∼20%) feature is detected near the jet base, indicating the presence of a well-ordered magnetic field. As a by-product, we additionally report a 43/86 GHz polarimetric result for our calibrator 3C 273, suggesting an extreme rotation measure near the core.

79 ASTRONOMY AND ASTROPHYSICS↗

Rancor-HUNTER: Using a Simulator Engine for Realistic Human Performance Modeling of Nuclear Power Operations

The Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER) is a software system to simulate human performance in support of human reliability analysis (HRA) in nuclear power plants. This paper summarizes recent work to integrate HUNTER with a plant simulator, namely the Rancor Microworld Simulator. Rancor is an offshoot of earlier work at Idaho National Laboratory (INL) to support plant modernization. The graphical software tools used to mimic digital human-system interface upgrades at INL’s Human Systems Simulation Laboratory were linked to the Rancor Microworld Simulator, an INL-developed simplified plant model. HUNTER becomes a “virtual operator” coupled to the Rancor simulator, thereby allowing a tight coupling between a digital human twin and a digital twin of the plant. Rancor-HUNTER may be run through Monte Carlo iterations across a dynamic range of performance shaping factors, thereby producing distributions of human performance in terms of procedure paths, errors instantiations, and task durations. This paper overviews the various unique features of Rancor-HUNTER and presents an example run of Rancor-HUNTER for a startup scenario.

99 - GENERAL AND MISCELLANEOUS↗

Bi-directional tuning of thermal transport in SrCoO x with electrochemically induced phase transitions

Unlike the wide-ranging dynamic control of electrical conductivity, there does not exist an analogous ability to tune thermal conductivity by means of electric potential. The traditional picture assumes that atoms inserted into a material’s lattice act purely as a source of scattering for thermal carriers, which can only reduce thermal conductivity. In contrast, here we show that the electrochemical control of oxygen and proton concentration in an oxide provides a new ability to bi-directionally control thermal conductivity. On electrochemically oxygenating the brownmillerite SrCoO 2.5 to the perovskite SrCoO 3–δ , the thermal conductivity increases by a factor of 2.5, whereas protonating it to form hydrogenated SrCoO 2.5 effectively reduces the thermal conductivity by a factor of four. This bi-directional tuning of thermal conductivity across a nearly 10 ± 4-fold range at room temperature is achieved by using ionic liquid gating to trigger the ‘tri-state’ phase transitions in a single device. We elucidated the effects of these anionic and cationic species, and the resultant changes in lattice constants and lattice symmetry on thermal conductivity by combining chemical and structural information from X-ray absorption spectroscopy with thermoreflectance thermal conductivity measurements and ab initio calculations. This ability to control multiple ion types, multiple phase transitions and electronic conductivity that spans metallic through to insulating behaviour in oxides by electrical means provides a new framework for tuning thermal transport over a wide range.

36 MATERIALS SCIENCE↗

Scaling from gauge and scalar radiation in Abelian-Higgs string networks

In this work, we investigate cosmic string networks in the Abelian Higgs model using data from a campaign of large-scale numerical simulations on lattices of up to 409 6 3 grid points. We observe scaling or self-similarity of the networks over a wide range of scales and estimate the asymptotic values of the mean string separation in horizon length units ξ ˙ and of the mean square string velocity v ¯ 2 in the continuum and large time limits. The scaling occurs because the strings lose energy into classical radiation of the scalar and gauge fields of the Abelian Higgs model. We quantify the energy loss with a dimensionless radiative efficiency parameter and show that it does not vary significantly with lattice spacing or string separation. This implies that the radiative energy loss underlying the scaling behavior is not a lattice artifact, and justifies the extrapolation of measured network properties to large times for computations of cosmological perturbations. We also show that the core growth method, which increases the defect core width with time to extend the dynamic range of simulations, does not introduce significant systematic error. We compare ξ ˙ and v ¯ 2 to values measured in simulations using the Nambu-Goto approximation, finding that the latter underestimate the mean string separation by about 25%, and overestimate v ¯ 2 by about 10%. The scaling of the string separation implies that string loops decay by the emission of massive radiation within a Hubble time in field theory simulations, in contrast to the Nambu-Goto scenario which neglects this energy loss mechanism. String loops surviving for only one Hubble time emit much less gravitational radiation than in the Nambu-Goto scenario and are consequently subject to much weaker gravitational wave constraints on their tension.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-CD-207B-07: Noise Modeling of Single Photon Avalanche Diode (SPAD) for Photon Counting CT Applications

Purpose: Silicon photomultiplier (SiPM) has recently emerged as a promising photodetector for biomedical imaging applications. Due to its high multiplication gain (comparable to PMT), fast timing, low cost and compactness, it is considered a good candidate for photon counting CT. Dark noise is a limiting factor which impacts both energy resolution and detection dynamic range. Our goal is to develop a comprehensive model for noise sources for SiPM sensors. Methods: The physical parameters used in this work were based upon a test SPAD fabricated in 130nm CMOS process. The SPAD uses an n+/p-well junction, which is isolated from the p-substrate by a deep n-well junction. Inter-avalanche time measurement was used to record the time interval between two adjacent avalanche pulses. After collecting 1×106 counts, the histogram was obtained and multiple exponential fitting process was used to extract the lifetime associated with the traps within the bandgap. Results: At room temperature, the breakdown voltage of the SPAD is ∼11.4V and shows a temperature coefficient of 7.7mV/°C. The dark noise of SPAD increases with both the excess biasing voltage and temperature. The primary dark counts from the model were validated against the measurement results. A maximum relative error of 8.7% is observed at 20 °C with an excess voltage of 0.5V. The probabilities of after-pulsing are found to be dependent of both temperature and excess voltage. With 0.5V excess voltage, the after-pulsing probability is 63.5% at - 30 °C and drops to ∼6.6% at 40 °C. Conclusion: A comprehensive noise model for SPAD sensor was proposed. The model takes into account of static, dynamic and statistical behavior of SPADs. We believe that this is the first SPAD circuit simulation model that includes the band-to-band tunneling dark noise contribution and temporal dependence of the after-pulsing probability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma Mirrors For High Power Lasers: A new approach for high repetition rates combined with realistic PIC simulations

We describe a research program to develop high quality plasma mirrors for use with high repetition rate, high power laser facilities to greatly facilitate experiments in high energy density physics, particularly when using solid density targets. A system delivering ultrathin, free standing liquid crystal films that could handle PW class laser pulses was developed that preserved the laser beam image quality and improved pulse contrast by over two orders of magnitude. The pulse contrast improvement was measured using a high dynamic range cross-correlation. The system operated at a repetition rate of several PMs formed in situ per minute. Extension to 1 Hz repetition rates should be possible. As a practical application, a PM system was used to separate laser accelerated electrons from the ultrashort pulse drive laser so that the electron beam emittance could be directly measured. The 20 nm thick PMs did not contribute significantly to emittance degradation. It was also demonstrated that the films could operate in the difficult plasma and laser environment present for GeV laser based electron acceleration. PM operation is still not well understood and much work with PMs is done empirically. Accordingly, we also demonstrated a particle-in-cell based simulation technique that would model PM operation, tracking the PM operation from cold, neutral atoms to a hot dense plasma by accounting for multiphoton ionization, plasma collisionality, and the dynamically changing index of refraction. Simulations in 3D were compared to a 2D based approach that was comparable. Finally, we developed a simpler model that can predict the intensity at which a plasma mirror will have its peak reflectivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Imaging with Event Camera

Neuromorphic or event-based imaging is a new, commercially available sensor technology inspired by how the human eye works. Instead of measuring frames at a fixed rate, the camera measures changes in pixel intensity asynchronously. This difference in readout architecture results in a high dynamic range and low latency. Event-based cameras have been used in a variety of applications, including object tracking, navigation, and lidar technologies. However, event-based cameras have not been adequately researched for their ability to image high-energy particles. This report explores the use of an event camera for imaging alpha, beta, and X-rays particles, when coupled with scintillator screens to convert high-energy particles into visible light. Methods to process event data were developed and are presented here, along with the results. The event camera can measure alpha and beta particles with comparable performance to that of a conventional camera. Event cameras can also image higher-activity sources and offer the possibility of discriminating particle interaction types on the basis of timing differences, which typical cameras cannot do. Additionally, event cameras can image objects with an X-ray source when the source strength dynamically changes but does not create a high-contrast image during static X-ray measurement.

47 OTHER INSTRUMENTATION↗

ANGULAR MOMENTUM TRANSPORT IN PROTOPLANETARY AND BLACK HOLE ACCRETION DISKS: THE ROLE OF PARASITIC MODES IN THE SATURATION OF MHD TURBULENCE

The magnetorotational instability (MRI) is considered a key process for driving efficient angular momentum transport in astrophysical disks. Understanding its nonlinear saturation constitutes a fundamental problem in modern accretion disk theory. The large dynamical range in physical conditions in accretion disks makes it challenging to address this problem only with numerical simulations. We analyze the concept that (secondary) parasitic instabilities are responsible for the saturation of the MRI. Our approach enables us to explore dissipative regimes that are relevant to astrophysical and laboratory conditions that lie beyond the regime accessible to current numerical simulations. We calculate the spectrum and physical structure of parasitic modes that feed off the fastest, exact (primary) MRI mode when its amplitude is such that the fastest parasitic mode grows as fast as the MRI. We argue that this 'saturation' amplitude provides an estimate of the magnetic field that can be generated by the MRI before the secondary instabilities suppress its growth significantly. Recent works suggest that the saturation amplitude of the MRI depends mainly on the magnetic Prandtl number. Our results suggest that, as long as viscous effects do not dominate the fluid dynamics, the saturation level of the MRI depends only on the Elsasser number {Lambda}{sub {eta}}. We calculate the ratio between the stress and the magnetic energy density, {alpha}{sub sat}{beta}{sub sat}, associated with the primary MRI mode. We find that for {Lambda}{sub {eta}} > 1 Kelvin-Helmholtz modes are responsible for saturation and {alpha}{sub sat}{beta}{sub sat} = 0.4, while for {Lambda}{sub {eta}} < 1 tearing modes prevail and {alpha}{sub sat}{beta}{sub sat} {approx_equal} 0.5 {Lambda}{sub {eta}}. Several features of numerical simulations designed to address the saturation of the MRI in accretion disks surrounding young stars and compact objects can be interpreted in terms of our findings.

79 ASTRONOMY AND ASTROPHYSICS↗

SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of Frequency-Division-Multiplexed Cryogenic Sensors

Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, cosmic microwave background, mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to transition-edge sensors or microwave kinetic inductance detectors. In principle, such arrays can be read out with vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In this work, we share plans and show initial results for SLAC Microresonator Radio Frequency (SMuRF) electronics, a next-generation control and readout system for superconducting microresonators. SMuRF electronics are unique in their implementation of specialized algorithms for closed-loop tone tracking, which consists of fast feedback and feedforward to each resonator’s excitation parameters based on transmission measurements. Closed-loop tone tracking enables improved system linearity, a significant increase in sensor count per readout line, and the possibility of overcoupled resonator designs for enhanced dynamic range. Low-bandwidth prototype electronics were used to demonstrate closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators, spaced at ~ 6 MHz with center frequencies ~ 5–6 GHz. We achieve multi-kHz tracking bandwidth and demonstrate that the noise floor of the electronics is subdominant to the noise intrinsic in the multiplexer.

47 OTHER INSTRUMENTATION↗

Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl

Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal and noise transfer properties of CsI:Tl phosphors. Three different CsI:Tl phosphors from two different vendors have been used to produce three system configurations. The performance of each system configuration has been studied in terms of the modulation transfer function (MTF), noise power spectra, and detective quantum efficiency (DQE) in the mammographic energy range. A simple method to determine quantum limited systems in this energy range is also presented. In addition, with aid of monochromatic synchrotron radiation, the effect of iodine characteristic x-rays of the CsI:Tl on the MTF has been determined. A Monte Carlo simulation of the signal transfer properties of the imager is also presented in order to study the stages that degrade the spatial resolution of our current system. The effect of using substrate patterning during the growth of CsI:Tl columnar structure was also studied, along with the effect of CsI:Tl fixed pattern noise due to local variations in the scintillation light. CsI:Tl fixed pattern noise appears to limit the performance of our current system configurations. All the system configurations are quantum limited at 0.23 {mu}C/kg with two of them having DQE (0) equal to 0.57. Active pixel flat panel imagers are shown to be digital x-ray imagers with almost constant DQE throughout a significant part of their dynamic range and in particular at very low exposures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending the Calibration of C iv-based Single-epoch Black Hole Mass Estimators for Active Galactic Nuclei

We provide an updated calibration of C iv λ1549 broad emission line–based single-epoch (SE) black hole (BH) mass estimators for active galactic nuclei (AGNs) using new data for six reverberation-mapped AGNs at redshift z=0.005--0.028 with BH masses (bolometric luminosities) in the range 10{sup 6.5}--10{sup 7.5} M{sub ⊙} (10{sup 41.7}--10{sup 43.8} erg s{sup −1}). New rest-frame UV-to-optical spectra covering 1150–5700 Å for the six AGNs were obtained with the Hubble Space Telescope (HST). Multicomponent spectral decompositions of the HST spectra were used to measure SE emission-line widths for the C iv, Mg ii, and Hβ lines, as well as continuum luminosities in the spectral region around each line. We combine the new data with similar measurements for a previous archival sample of 25 AGNs to derive the most consistent and accurate calibrations of the C iv-based SE BH mass estimators against the Hβ reverberation-based masses, using three different measures of broad-line width: full width at half maximum (FWHM), line dispersion (σ{sub line}), and mean absolute deviation (MAD). The newly expanded sample at redshift z=0.005--0.234 covers a dynamic range in BH mass (bolometric luminosity) of logM{sub BH}/M{sub ⊙}=6.5--9.1 (logL{sub bol}/ erg s{sup −1} = 41.7--46.9), and we derive the new C iv-based mass estimators using a Bayesian linear regression analysis over this range. We generally recommend the use of σ{sub line} or MAD rather than FWHM to obtain a less biased velocity measurement of the C iv emission line, because its narrow-line component contribution is difficult to decompose from the broad-line profile.

79 ASTRONOMY AND ASTROPHYSICS↗

A Mobile Automated Tomographic Gamma Scanning System - 13231

Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transport container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 keV/channel resolution to support both isotopic analysis with the MGA/MGAU software and a wide 3 MeV dynamic range. The calibration and verification of the system is discussed, and quantitative results are presented for a variety of drum types and matrices. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

COMMISSIONING OF THE SRF SURFACE IMPEDANCE CHARACTERIZATION SYSTEM AT JEFFERSON LAB

Superconducting radio frequency (SRF) technology is widely adopted in particle accelerators. There remain many open questions, however, in developing a systematic understanding of the fundamental behavior of SRF materials, including niobium treated in different ways and various other bulk/thin film materials that are fabricated with different methods under assorted conditions. A facility that can measure the SRF properties of small samples in a range of 0~180 mT surface field and 2~20 K temperature is needed in order to fully answer these questions. The Jefferson Lab surface impedance characterization (SIC) system [1] has been designed to attempt to meet this requirement. It consists of a sapphire-loaded cylindrical Nb TE011 cavity at 7.5 GHz with a 50 mm diameter flat sample placed on a non-contacting end plate and uses a calorimetric technique [2-5] to measure the rf induced heat on the sample. Driving the resonance to a known field on this surface enables one to derive the surface resistance of the small localized area. TE011 mode identification has been done at room temperature and 4 K, and has been compared with Microwave Studio® simulation results. The variable input and transmitted rf couplers have been characterized. Rf loss mechanisms in the SIC system are under investigation. Thermal properties of the calorimeter have been well studied. A second generation calorimeter is being developed to optimize the dynamic range of the system. A prototype VCO phase lock loop system has been used in CW mode. Preliminary tests with bulk Nb samples have been done at <3 mT magnetic field. The presently available hardware is expected to enable up to 20 mT peak magnetic field on the sample, and paths to higher field tests have been identified.

Xiao, Binping↗