Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENERGY CONSUMPTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Online eco-routing for electric vehicles using combinatorial multi-armed bandit with estimated covariance

Identifying energy-efficient routes in real-time has significant implications for the energy-optimal operations of electric vehicles (EVs). Here, this study proposes a novel model for EV online eco-routing problem, which obtains the minimal expected energy consumption paths (MECPs) for multiple origin-destination (OD) pairs simultaneously. Specifically, we formulate the routing problem as a bandit problem and solve it with online algorithms. We extend the algorithms by implementing a path elimination mechanism to reduce the candidate path set and introducing the variance and covariance of the energy consumption to reduce the uncertainties. The numerical results show that the proposed algorithms can efficiently obtain near-optimal MECPs, and the solution is significantly better than the widely used shortest trip time path algorithm (STTP) and shortest trip distance path algorithm (SDP). The variation considering link energy covariance and path elimination generates paths that save 4.1% of energy compared to the SDP and 5.4% to the STTP.

33 ADVANCED PROPULSION SYSTEMS↗

Understanding airflow pattern and temperature distribution in domestic refrigerators – A review analyzing recent developments and bridging knowledge gaps

Refrigerators have become an essential appliance in every household, and they consume approximately 30% of total electricity among other domestic appliances such as clothes washers, dryers, and air conditioners. With the refrigerator’s comparatively high energy consumption compared with other appliances, existing research has mainly focused on improving the energy efficiency of refrigerators by changing the design of the compressor, heat exchanger, refrigerant, and insulation. However, previous studies have paid very little attention to the research and development of the temperature distribution in the refrigerator, which is a key parameter in determining energy consumption and food safety. Therefore, this review aims to present an overview of recent design developments to improve the temperature distribution and air circulation in domestic refrigerators, including static refrigerators and no-frost refrigerators. Herein, this review article discusses the various operation and design factors that can affect the air circulation and temperature uniformity of the refrigerator, including shelf arrangement, the compressor on/off cycle, thermostat settings, evaporator design, ambient conditions, door opening frequency, and product loading temperatures. Additionally, this review provides a summary of the advanced vapor compression cycle based refrigerators that are expected to provide better energy efficiency and independent temperature control in freezer and refrigerator compartments. This review elaborates on the significance of improving the performance of the domestic refrigerator in terms of temperature distribution and air circulation.

42 ENGINEERING↗

Feasibility of Operating a Heavy-Duty Battery Electric Truck Fleet for Drayage Applications

Vehicle fleet electrification is regarded as one major pathway toward achieving energy independence and reducing air pollution and greenhouse gas emissions. Compared to light-duty and medium-duty vehicles, electrification of heavy-duty vehicles, especially Class 8 trucks, is more challenging owing to the battery size required to attain the driving range necessary for their operating goals. As drayage trucks generally have a limited daily mileage, return to a home base every night, and spend a large amount of time creeping and idling, drayage operation has been the first targeted application for Class 8 electric trucks. The feasibility of operating battery electric drayage trucks at the individual vehicle level has recently been demonstrated. However, questions remain as to whether these trucks are capable of meeting the needs of typical drayage operation at the fleet level. Here we present a feasibility analysis of operating an electric truck fleet based on real-world operation data of a diesel drayage operator in Southern California. Second-by-second activity data collected from 20 trucks in the fleet were used to estimate the corresponding electric energy consumption and the state of charge of the battery using a microscopic electric energy consumption model. An algorithm for generating tours of drayage activity from the collected data was developed and implemented. Multiple scenarios with different battery charging and truck scheduling assumptions were analyzed. The results show that 85% of the tours could be served by electric trucks if there is opportunity for charging at the home base during the time gap between consecutive tours.

33 ADVANCED PROPULSION SYSTEMS↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Future Cost Benefits Analysis for Electrified Vehicles from Advances Due to U.S. Department of Energy Targets

The U.S. Department of Energy’s Vehicle Technologies Office (DOE-VTO) supports research and development (R&D), as well as deployment of efficient and sustainable transportation technologies, that will improve energy efficiency and fuel economy and enable America to use less petroleum. To accelerate the creation and adoption of new technologies, DOE-VTO has developed specific targets for a wide range of powertrain technologies (e.g., engine, battery, electric machine, lightweighting, etc.). This paper quantifies the impact of VTO R&D on vehicle energy consumption and cost compared to expected historical improvements across vehicle classes, powertrains, component technologies and timeframes. We have implemented a large scale simulation process to develop and simulate tens of thousands of vehicles on U.S. standard driving cycles using Autonomie, a vehicle simulation tool developed by Argonne National Laboratory. Results demonstrate significant additional reductions in both cost and energy consumption due to the existence of VTO R&D targets compared to predicted historical trends. It is observed that, over time, the fuel consumption of different electrified vehicles is expected to decrease by 40–50% and a reduction of 45–55% for vehicle manufacturing costs owing to significant improvements through various VTO R&D targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Water Heating Demand Side Management (DSM) - South Africa

The electricity crisis in South Africa has deteriorated significantly, with the country experiencing frequent and prolonged rolling blackouts. These outages have severe economic repercussions, leading to decreased growth and productivity. Demand Side Management (DSM), particularly focusing on electric water heaters due to their significant energy consumption and peak demand contribution, is identified as a key strategy. The study aims to assess opportunities for DSM programs targeting water heating to reduce energy consumption and peak demand. It entails developing a bottom-up simulation model to establish a baseline scenario of water heating electricity load demand in 2023 and 2033, identifying technologies for energy reduction, estimating the impacts of a selected number of measures and providing recommendations to inform policy makers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermochromic Halide Perovskite Windows with Ideal Transition Temperatures

Abstract Urban centers across the globe are responsible for a significant fraction of energy consumption and CO 2 emission. As urban centers continue to grow, the popularity of glass as cladding material in urban buildings is an alarming trend. Dynamic windows reduce heating and cooling loads in buildings by passive heating in cold seasons and mitigating solar heat gain in hot seasons. Here, reduced energy consumption in highly glazed buildings in a mesoscopic building energy model is demonstrated when thermochromic windows are employed. Savings are realized across eight disparate climate zones of the United States. The model is used to determine ideal critical transition temperatures of 20–27.5 °C for thermochromic windows based on metal halide perovskite materials. Ideal transition temperatures are realized experimentally in composite metal halide perovskite films composed of perovskite crystals and an adjacent reservoir phase. The transition temperature is controlled by cointercalating methanol, instead of water, with methylammonium iodide and tailoring the hydrogen‐bonding chemistry of the reservoir phase. Thermochromic windows based on metal halide perovskites represent a clear opportunity to mitigate the effects of energy‐hungry buildings.

14 SOLAR ENERGY↗

Unbundling Smart Meter Services Through Spatio-Temporal Decomposition Agents in DER-rich Environment

Smart meters and the advanced metering infrastructure (AMI) facilitate distribution system operators (DSOs) to gather information on energy consumption at the customer level. With the increasing penetration of building-level intermittent distributed energy resources (DERs) behind the meter, DER information is not available to DSOs. At the same time, smart meter enables users to participate in grid, with real-time information. Information for behind the meter is needed by user to coordinate building level assets for maximum benefits. The concept of unbundled smart meter (USM) needs agents to decompose smart meter measurements to provide service to DSO as well as customers. In this paper, we propose a Spatio-Temporal Decomposition Agent (STDA) for USM based on Artificial Intelligence (AI). STDA can help users optimize their energy usage, help DSO to utilize building assets for the grid operation. The energy usage strategy developed by STDA is suitable for different users, and can be customized by deep learning (DL) models according to the different energy consumption habits of each user. The power prediction performance results of various DL models and evaluation using a set of data from a Hawaii utility is presented. Furthermore, STDA integration with Home Energy management Systems (HEMS) to manage resources is presented and validated. STDA pre-processes the measurements before model training, and provides the spatio-temporal decomposed forecasting.

42 ENGINEERING↗

nrelWattileExt (SkySpark Wattile Extension) [SWR-24-73]

The NREL Wattile extension, nrelWattileExt, provides an interface between SkySpark, an energy management and analytics software, and Wattile, an NREL-developed Python package for probabilistic prediction of building energy consumption. Wattile models predict discrete quantiles of the probability distribution of a target quantity (typically energy consumption) using the historical time series data from one or more predictors (typically weather data). Within SkySpark, predictions from Wattile models can be used for measurement & verification of building performance, detection of energy anomalies, and fault detection. Related to: https://github.com/NREL/Wattile

Frank, Stephen↗

Identifying Regions Favorable for Geothermal Heating and Cooling Storage

Space heating and cooling represents the single largest category of in building energy use for U.S. residential and commercial buildings, with heating representing 61% of residential and 46% commercial energy consumption. Building heating technologies are dominated by natural gas technologies, and are an important opportunity for building electrification to enable a transition to a low CO 2 energy system. FLXenabler study is a joint analysis effort among multiple analysis teams at NREL and focused on examining the role of geothermal heating and cooling (GHC) system with thermal energy storage (TES) providing flexibility. Utilizing information from ResStock the amount of energy consumption associated with heating and cooling by state was calculated. We applied adjusted load shapes to estimate the a maximum grid savings potential of using TES to address building space conditioning. Normalizing grid, fuel, and emissions impacts locations with higher favorability for further study in FLXenabler were identified.

15 GEOTHERMAL ENERGY↗

A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation

Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM product, tested in eight homes. The match rate metric—a technique recommended by a technical advisory group—was used to measure the NILM’s success in identifying specific loads and the accuracy of the energy consumption estimates. A performance assessment protocol was also developed to address common issues with NILM mislabeling and ground-truth comparisons that have not been sufficiently addressed in past evaluations. The NILM product’s estimates were compared to the submetered consumption of eight major appliances. Overall, the product had good performance in disaggregating the energy consumption of the electric water heaters, which included both electric resistance and heat-pump water heaters, but only a fair accuracy with refrigerators, dryers, and air conditioners. The performance was poor for cooking equipment, furnace fans, clothes washers, and dishwashers. Moreover, the product was often unable to detect major loads in homes. Typically, two or more appliances were not detected in a home. At least two dryers, furnace fans, and air conditioners went undetected across the eight homes. On the other hand, the dishwasher was detected in all homes where available or monitored. The key findings were qualitatively compared to those of past field evaluations. Potential areas for improvement in NILM product performance were determined along with areas where complementary technologies may be able to aid in load-disaggregation applications.

47 OTHER INSTRUMENTATION↗

IONAC-Lite

The Interplanetary Overlay Net - working Protocol Accelerator (IONAC) described previously in The Inter - planetary Overlay Networking Protocol Accelerator (NPO-45584), NASA Tech Briefs, Vol. 32, No. 10, (October 2008) p. 106 (http://www.techbriefs.com/component/ content/article/3317) provides functions that implement the Delay Tolerant Networking (DTN) bundle protocol. New missions that require high-speed downlink-only use of DTN can now be accommodated by the unidirectional IONAC-Lite to support high data rate downlink mission applications. Due to constrained energy resources, a conventional software implementation of the DTN protocol can provide only limited throughput for any given reasonable energy consumption rate. The IONAC-Lite DTN Protocol Accelerator is able to reduce this energy consumption by an order of magnitude and increase the throughput capability by two orders of magnitude. In addition, a conventional DTN implementation requires a bundle database with a considerable storage requirement. In very high downlink datarate missions such as near-Earth radar science missions, the storage space utilization needs to be maximized for science data and minimized for communications protocol-related storage needs. The IONAC-Lite DTN Protocol Accelerator is implemented in a reconfigurable hardware device to accomplish exactly what s needed for high-throughput DTN downlink-only scenarios. The following are salient features of the IONAC-Lite implementation: An implementation of the Bundle Protocol for an environment that requires a very high rate bundle egress data rate. The C&DH (command and data handling) subsystem is also expected to be very constrained so the interaction with the C&DH processor and the temporary storage are minimized. Fully pipelined design so that bundle processing database is not required. Implements a lookup table-based approach to eliminate multi-pass processing requirement imposed by the Bundle Protocol header s length field structure and the SDNV (self-delimiting numeric value) data field formatting. 8-bit parallel datapath to support high data-rate missions. Reduced resource utilization implementation for missions that do not require custody transfer features. There was no known implementation of the DTN protocol in a field programmable gate array (FPGA) device prior to the current implementation. The combination of energy and performance optimization that embodies this design makes the work novel.

Torgerson, Jordan L.↗

Industrial Locomotive Inventory Analysis

Due to their captive and local operations, industrial locomotives present a unique potential to reduce energy consumption and associated costs through application of advanced locomotive technologies. However, until now, there has been no data source for the number, size (hp), usage, and energy consumption of these locomotives, which limits the ability to design and implement a research, development, and deployment strategy. This research addresses this gap by developing the first national inventory of locomotives in industrial use and provides a tool to explore the energy and emissions associated with this transportation segment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Comparative Analysis of ANN and LSTM Prediction Accuracy and Cooling Energy Savings through AHU-DAT Control in an Office Building

This paper proposes the optimal algorithm for controlling the HVAC system in the target building. Previous studies have analyzed pre-selected algorithms without considering the unique data characteristics of the target building, such as location, climate conditions, and HVAC system type. To address this, we compare the accuracy of cooling load prediction using ANN and LSTM algorithms, widely used in building energy research, to determine the optimal algorithm for HVAC control in the target building. We develop a simulation model calibrated with actual data to ensure data reliability and compare the energy consumption of the existing HVAC control method and the two algorithms-based methods. Results show that the ANN algorithm, with a CV(RMSE) of 12.7%, has a higher prediction accuracy than the LSTM algorithm, CV(RMSE) of 17.3%, making it a more suitable algorithm for HVAC control. Furthermore, implementing the ANN-based approach results in a 3.2% cooling energy reduction from the optimal control of Air Handling Unit (AHU) Discharge Air Temperature (DAT) compared to the fixed DAT at 12.8 °C in a representative day. This study demonstrates that ML-based HVAC system control can effectively reduce cooling energy consumption in HVAC systems, providing an effective strategy for energy conservation and improved HVAC system efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric heating and cooling–integrated dishwasher with thermal energy storage

Household dishwashers must address several performance goals: maximize washing and drying performance, while minimizing cycle duration, energy consumption, and water consumption. This study develops and examines a novel thermoelectric heating and cooling (TEHC) system with thermal energy storage applied to a household dishwasher (DW), aiming to improve the energy and drying performance of a commercially-available dishwasher while maintaining its washing performance, water consumption, and cycle duration. Experimental testing conducted on the novel TEHC-DW system demonstrates an 8.7% reduction in total energy consumption, lowering the per-cycle usage to 0.952 kWh, and a 40% reduction in energy consumption for internal water heating. The novel TEHC-DW system also demonstrates better drying performance, shortening the drying time by 42% to reach the same remaining moisture content as a commercially-available system. In addition, a resistance-capacitance network model is developed that predicts total drying time, total energy consumption, and the highest temperature reached in the tub (53.4 °C). The model accuracy is validated with experimental data (within ±1 K), and the model functions as a design tool via a parametric study to evaluate the next-generation design and the effect of the number of thermoelectric modules and thermoelectric driving force (i.e., current). Overall, this study demonstrates the potential for TEHC technology to improve energy efficiency and drying performance in household dishwashers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗