Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equivalent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Monte Carlo simulations demonstrating physics of equivalency of gamma, electron-beam, and X-ray for radiation sterilization

We report the sterilization of medical devices using the gamma rays from the decay of cobalt-60 has accumulated decades of experience of the performance of the materials and devices that are irradiated. The use of radiation using electron beams and x-rays has much less experience and this leads to questions of equivalency between these three technologies. Computer simulations were conducted to model the relevant physical processes of the interactions of each of the three forms of radiation in order to compare the spectra of electron energies at energies below 500 keV. It is predominantly the electrons below this threshold that produce the sterilization dose. No difference in energy spectra was seen between the three types of initial radiation. It is concluded that there is no energy dependent difference between gamma, e-beam, and x-ray for radiation sterilization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimation Of Charge Transport Parameters And Equivalent Circuit For Poly Alkyl Thiophene Field-Effect Transistors

The small signal ac response is measured across the source-drain terminals of organic field-effect transistors (OFET) under dc bias to obtain the equivalent circuit parameters of poly (2,5-bis(3-tetradecylthiophen-2-yl)thieno[3,2-b]thiophene)(PBTTT) and poly(3-hexyl thiophene)(P3HT) based devices. The numerically simulated response based on these parameters is in good agreement with the experimental data for PBTTT-FET except at low frequencies, while the P3HT-FET data show significant deviations. This indicates that the interface with the metal electrode is rather complex for the latter, involving additional circuit elements arising from contact impedance or charge injection processes. Such an investigation can help in identifying the operational bottlenecks and to improve the performance of OFETs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Overall performance evaluation using an equivalent circuit model for radio-frequency single-electron transistors

Charge sensitivities of a radio-frequency single-electron transistor (RF-SET) by using amplitude (AD) and phase-shift detection (PSD) of the reflected RF signals were experimentally studied. It was found that AD is most sensitive at the resonant frequency while PSD is most sensitive at a frequency slightly off the resonance. The best PSD sensitivity is better than the best AD one when the quality factor of a tank circuit is higher than 10; the higher Q-value is, the superior PSD. The maximal change in reflection amplitude and phase-shift were found proportional to the SET conductance change. The above experimental findings were confirmed by the calculation based on an equivalent circuit model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The simplest equivalent circuit of a pulsed dielectric barrier discharge and the determination of the gas gap charge transfer

The concept of the simplest equivalent circuit for a dielectric barrier discharge (DBD) is critically reviewed. It is shown that the approach is consistent with experimental data measured either in large-scale sinusoidal-voltage driven or miniature pulse-voltage driven DBDs. An expression for the charge transferred through the gas gap q(t) is obtained with an accurate account for the displacement current and the values of DBD reactor capacitance. This enables (i) the significant reduction of experimental error in the determination of q(t) in pulsed DBDs, (ii) the verification of the classical electrical theory of ozonizers about maximal transferred charge q{sub max}, and (iii) the development of a graphical method for the determination of q{sub max} from charge-voltage characteristics (Q-V plots, often referred as Lissajous figures) measured under pulsed excitation. The method of graphical presentation of q{sub max} is demonstrated with an example of a Q-V plot measured under pulsed excitation. The relations between the discharge current j{sub R}(t), the transferred charge q(t), and the measurable parameters are presented in new forms, which enable the qualitative interpretation of the measured current and voltage waveforms without the knowledge about the value of the dielectric barrier capacitance C{sub d}. Whereas for quantitative evaluation of electrical measurements, the accurate estimation of the C{sub d} is important.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrically detected magnetic resonance modeling and fitting: An equivalent circuit approach

The physics of electrically detected magnetic resonance (EDMR) quadrature spectra is investigated. An equivalent circuit model is proposed in order to retrieve crucial information in a variety of different situations. This model allows the discrimination and determination of spectroscopic parameters associated to distinct resonant spin lines responsible for the total signal. The model considers not just the electrical response of the sample but also features of the measuring circuit and their influence on the resulting spectral lines. As a consequence, from our model, it is possible to separate different regimes, which depend basically on the modulation frequency and the RC constant of the circuit. In what is called the high frequency regime, it is shown that the sign of the signal can be determined. Recent EDMR spectra from Alq{sub 3} based organic light emitting diodes, as well as from a-Si:H reported in the literature, were successfully fitted by the model. Accurate values of g-factor and linewidth of the resonant lines were obtained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equivalent circuit analysis of radiative coupling in monolithic tandem solar cells

As solar cell efficiency improves towards the Shockley-Queisser limit, so does the radiative efficiency of the cell. For tandem stacks of cells where energy conversion efficiency now exceeds 46%, radiative coupling between the cells is becoming increasingly important to consider in cell design, measurement, and performance prediction. We show how an equivalent circuit model can capture the complex radiative interactions between cells in such tandem stacks, allowing more insight into the impact on cell performance. The circuit's use is demonstrated by deriving results relevant to the critical step of eliminating coupling effects from measured cell spectral responses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The study of equivalent dose of uranium in long bean (V. U. Sesquipedalis) and the effect on human

In the case of accidental release of Uranium-238 ({sup 238}U) radionuclides in a nuclear facility or in the environment, internal contamination by either acute or chronic exposure has the potential to induce both radiological and chemical toxic effects. A study was conducted to estimate the {sup 238}U radionuclide concentration in the long beans using Induced Coupled Mass Plasma-Spectrometry (ICP-MS). {sup 238}U radionuclide is a naturally occurring radioactive material that can be found in soil and can be transferred to the long bean (Vigna unguiculata subsp. Sesquapedalis) directly or indirectly via water or air. Kidney and liver are the major sites of deposition of {sup 238}U radionuclide. The obtained dose exposed in the liver and kidney is used to assess the safety level for public intake of {sup 238}U radionuclide from the consumption of long beans. The concentration of {sup 238}U radionuclide measured in long bean samples was 0.0226 ± 0.0009 mg/kg. Total activity of {sup 238}U radionuclide was 0.0044 ± 0.0002 Bq/day with the daily intake of 0.3545 ± 0.0143 µg/day and the annual committed effective dose due to ingestion of {sup 238}U radionuclide in long beans was 0.2230 ± 0.0087 µSv/year. The committed equivalent dose of {sup 238}U radionuclide from the assessment in the liver and kidney are 0.4198 ± 0.0165 nSv and 10.9335 ± 0.4288 nSv. The risk of cancer of {sup 238}U radionuclide was determined to be (86.0466 ± 3.3748) × 10-9. Thus, the results concluded that {sup 238}U radionuclide in local long beans was in the permitted level and safe to consume without posing any significant radiological threat to population.

54 ENVIRONMENTAL SCIENCES↗

Material characteristics and equivalent circuit models of stacked graphene oxide for capacitive humidity sensors

The oxidation properties of graphene oxide (GO) are systematically correlated with their chemical sensing properties. Based on an impedance analysis, the equivalent circuit models of the capacitive sensors are established, and it is demonstrated that capacitive operations are related to the degree of oxidation. This is also confirmed by X-ray diffraction and Raman analysis. Finally, highly sensitive stacked GO sensors are shown to detect humidity in capacitive mode, which can be useful in various applications requiring low power consumption.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A MEMS disk resonator-based band pass filter electrical equivalent circuit simulation

In this paper, coupled beam bandpass Disk filter is designed for 1 MHz bandwidth. Filter electrical equivalent circuit simulation is performed using circuit simulators. Important filter parameters such as insertion loss, shape factor and Q factor aresetimated using coventorware simulation. Disk resonator based radial contour mode filter provides 1.5 MHz bandwidth and unloaded quality factor of resonator and filter as 233480, 21797 respectively. From the simulation result it’s found that insertion loss minimum is 151.49 dB, insertion loss maximum is 213.94 dB, and 40 dB shape factor is 4.17.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the correct choice of equivalent circuit for fitting bulk impedance data of ionic/electronic conductors

Bulk conductivity data of ionically and electronically conducting solid electrolytes and electronic ceramics invariably show a frequency dependence that cannot be modelled by a single-valued resistor. To model this, common practice is to add a constant phase element (CPE) in parallel with the bulk resistance. To fit experimental data on a wide variety of materials, however, it is also essential to include the limiting, high frequency permittivity of the material in the equivalent circuit. Failure to do so can lead to incorrect values for the sample resistance and CPE parameters and to an inappropriate circuit for materials that are electrically heterogeneous.

36 MATERIALS SCIENCE↗

Macroscopic modeling of gas permeability in hierarchical micro/nanoporous media: A unified characterization of rarefaction using Klinkenberg theory and equivalent diameter

Estimating gas transport through a hierarchical micro/nanoporous system is challenging due to non-equilibrium gas dynamics. The primary difficulty lies in determining the rarefaction level, because identifying a representative flow dimension in a complex porous system with multiple pore scales is not straightforward. Our study performed a pore-level analysis for gas permeability in dual-scale porous media with varying porosity, throat size, and secondary pore size under different rarefaction conditions. We found that secondary porosity negatively affects permeability due to increased friction forces, with this influence growing as the secondary pore size and porosity increase until the secondary pore becomes comparable to the throat. However, rarefaction reduces the effects of secondary pores due to boundary slip. Traditional Knudsen number (Kn) calculations based on Darcy-defined height failed to accurately describe the rarefaction effects on gas permeability. Instead, we introduced an equivalent diameter to calculate the Kn, which provided an accurate normalization of apparent gas permeability independent of pore geometry. Furthermore, the extended Kozeny–Carman–Klinkenberg model developed in our previous study successfully yielded a macroscopic model for apparent gas permeability in hierarchical micro/nanoporous systems as a function of the traditional Darcy height and porosity.

04 OIL SHALES AND TAR SANDS↗

Equivalent circuit-level model and improvement of terahertz quantum cascade lasers

An equivalent circuit-level model of terahertz (THz) quantum cascade lasers (QCLs) is developed by using rate equations. This model can be employed to investigate the characteristics of THz QCLs accurately and to improve their design. We use the circuit-level model to analyse a new active structure, which can improve the performance of THz QCLs by means of enhancing carrier injection. The simulation result shows that THz QCLs with the new active structure have a much higher performance compared with conventional THz QCLs. The high-performance THz QCLs are expected to be operated at higher temperatures. (lasers)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Equivalent circuit-level model of quantum cascade lasers with integrated hot-electron and hot-phonon effects

We report a study of the effects of hot-electron and hot-phonon dynamics on the output characteristics of quantum cascade lasers (QCLs) using an equivalent circuit-level model. The model is developed from the energy balance equation to adopt the electron temperature in the active region levels, the heat transfer equation to include the lattice temperature, the nonequilibrium phonon rate to account for the hot phonon dynamics and simplified two-level rate equations to incorporate the carrier and photon dynamics in the active region. This technique simplifies the description of the electron–phonon interaction in QCLs far from the equilibrium condition. Using the presented model, the steady and transient responses of the QCLs for a wide range of sink temperatures (80 to 320 K) are investigated and analysed. The model enables us to explain the operating characteristics found in QCLs. This predictive model is expected to be applicable to all QCL material systems operating in pulsed and cw regimes. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trends in surface equivalent potential temperature: A more comprehensive metric for global warming and weather extremes

Significance The Earth has warmed by 1.2 ± 0.1 °C since the preindustrial era. The most common metric to measure the ongoing global warming is surface air temperature since it has long and reliable observational records. However, surface air temperature alone does not fully describe the nature of global warming and its impact on climate and weather extremes. Here we show that surface equivalent potential temperature, which combines the surface air temperature and humidity, is a more comprehensive metric not only for the global warming but also for its impact on climate and weather extremes including tropical deep convection and extreme heat waves. We recommend that it should be used more widely in future climate change studies.

54 ENVIRONMENTAL SCIENCES↗

Three-Dimensional Full-Core BEAVRS Using OpenMOC with Transport Equivalence

Using an optimized implementation of the three-dimensional (3D) method of characteristics for neutron transport, along with a novel equivalence method for transport calculations that was designed to correct self-shielding errors from neglecting the angular dependence of resonant group absorption, a 3D full-core light water reactor hybrid stochastic-deterministic eigenvalue calculation was achieved. This paper presents the optimizations developed and compares the transport solutions obtained. For the statepoint, run times near 10 000 CPU hours are achieved—improving on previous works by an order of magnitude—with near 1% error on pin fission to 238 U capture ratios and a few dozen pcms on the eigenvalue.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HIGH-PRECISION TIMING OF FIVE MILLISECOND PULSARS: SPACE VELOCITIES, BINARY EVOLUTION, AND EQUIVALENCE PRINCIPLES

We present high-precision timing of five millisecond pulsars (MSPs) carried out for more than seven years; four pulsars are in binary systems and one is isolated. We are able to measure the pulsars' proper motions and derive an estimate for their space velocities. The measured two-dimensional velocities are in the range 70-210 km s{sup -1}, consistent with those measured for other MSPs. We also use all the available proper motion information for isolated and binary MSPs to update the known velocity distribution for these populations. As found by earlier works, we find that the velocity distribution of binary and isolated MSPs are indistinguishable with the current data. Four of the pulsars in our observing program are highly recycled with low-mass white dwarf companions and we are able to derive accurate binary parameters for these systems. For three of these binary systems, we are able to place initial constraints on the pulsar masses with best-fit values in the range 1.0-1.6 M{sub Sun }. The implications of the results presented here to our understanding of binary pulsar evolution are discussed. The updated parameters for the binary systems studied here, together with recently discovered similar systems, allowed us to update previous limits on the violation of the strong equivalence principle through the parameter |{Delta}| to 4.6 Multiplication-Sign 10{sup -3} (95% confidence) and the violation of Lorentz invariance/momentum conservation through the parameter |{alpha}-hat3| to 5.5 Multiplication-Sign 10{sup -20} (95% confidence).

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic transients test Einstein’s Equivalence Principle out to GeV energies

The Einstein Equivalence Principle (EEP) can be probed with astrophysical sources emitting simultaneously different types of neutral particles, or particles with varying energies, by testing their time of flight through the same gravitational field. Here we use the time delays between correlated photons from cosmological transients to constrain the accuracy of the EEP. We take data from two gamma-ray bursts as an example and, as a lower limit to the theoretical time delays between different energies, we use delays arising from only the gravitational field of our own galaxy. We then show that the parameterized post-Newtonian parameter γ is the same for photons over energy ranges between eV and MeV and between MeV and GeV to a part in 10{sup −7}, which is at least one order of magnitude better than previous limits. Combining this bound on the wavelength dependence of γ with the absolute bound |γ−1|<0.3% from light-deflection measurements at optical (eV) wavelengths, we thus extend this absolute bound on γ to GeV energies.

79 ASTRONOMY AND ASTROPHYSICS↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗