Search NASA⌕ Search

SEARCH · Search NASA

Results for “Explosive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A multi-Physics Experiment for Low-Yield Nuclear Explosion Monitoring

A series of multi-physics experiments, referred to as Physics Experiment 1 (PE1) is underway at the United States’ Nevada National Security Site (NNSS). The PE1 series includes detonations of three underground chemical explosions in P-tunnel, with fully coupled (PE1 A), partially decoupled (PE1 D L ), and fully decoupled (PE1 B) emplacements. Canisters with gas tracers are imbedded in the explosives, and the tracers are released when the canister is destroyed by the detonation. A dedicated electromagnetic (EM) experiment (EMX) generates well-characterized EM signals at an underground location near the chemical explosive experiments. A series of atmospheric experiments (METEX, REACT, and METREX) release smoke and radioactive tracers around Aqueduct Mesa to test gas transport in complex topography. Each of the chemical explosive experiments includes a network of sensors to record seismic, acoustic, and electromagnetic waves, measurement of atmospheric conditions, and air sample collection for measurement of tracer concentration. EMX records EM signals underground and on the surface of Aqueduct Mesa. METEX, REACT, and METREX include measurement of atmospheric condition, as well as tracking smoke releases. REACT and METREX add low-level radioactive gas tracers to the atmospheric releases.

58 GEOSCIENCES↗

Temperature and Pressure Instrumentation for LYNM PE1 Chemical Explosive Testing

Underground chemical explosive testing has been conducted at the Nevada National Security Site under the Physics Experiment 1 (PE1) to validate explosive computer modeling and, ultimately, improve the accuracy of subsurface explosive detection. This SAND Report describes the dynamic temperature and pressure measurements within the chamber induced by the chemical explosive for the first of three experiments, PE1-A. The report details the instrumentation used for the experiment, the emplacement of the hardware, and the measured results. Dynamic temperature measurements were accomplished with the use of optical spectrometers and dynamic pressure was measured with a series of high-rated pressure transducers. This report includes details of the design and results of four cavity sensor systems used to measure early-time temperature, early-time pressure, late-time temperature, and late time pressure. The outcomes of PE1-A were used to inform the design of the remaining PE1 series experiments, PE1-B and PE1-DL.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Final CRADA Report: Evaluation of Trace Particle Removal Techniques for Enhanced Detection of Explosives in Air Cargo

This report describes the procedures used and the test results obtained at the Idaho National Laboratory (INL), to determine the ability of thermal and mechanical (vibration and airflow) methods to remove/harvest trace explosives from various material substrate surfaces relevant to air cargo. As part of the Battelle Memorial Institute’s (BMI) Air Cargo Screening (ACS) Initiative, INL conducted mechanical and thermal/mechanical removal tests using three different military explosives: C-4(RDX), cast TNT, and SEMTEX (PETN, 76% and RDX, 4.6%) on two substrate materials relevant to air cargo: metal and cardboard. This work leveraged similar experiments using homemade explosives (HME) which were funded by the Department of Homeland Security’s Science and Technology Directorate (DHS S&T). The DHS S&T tests involved evaluating the removal efficiencies of thermal and mechanical methods for four different HME: Ammonium Nitrate prills (AN, explosive grade), Guanidine Nitrate (GN, 98% pure in Methanol), Triacetone Triperoxide (TATP, 99.5% pure in Acetonitrile), and Hexamethylene Triperoxide Diamine (HMTD, 98.4% pure in Acetonitrile). Substrate materials used for the HME removal tests included metal, cotton, canvas, leather, shrink wrap, cardboard, and vinyl. This report documents the procedures that were used during the testing as well as the test results and recommendations for future Air Cargo Screening applications.

Source record↗

Type Ia Supernova Explosions From Hybrid Carbon–Oxygen–Neon White Dwarf Progenitors

Motivated by recent results in stellar evolution that predict the existence of hybrid white dwarf (WD) stars with a C–O core inside an O–Ne shell, we simulate thermonuclear (Type Ia) supernovae from these hybrid progenitors. We use the FLASH code to perform multidimensional simulations in the deflagration-to-detonation transition (DDT) explosion paradigm. Our hybrid progenitor models were produced with the MESA stellar evolution code and include the effects of the Urca process, and we map the progenitor model to the FLASH grid. We performed a suite of DDT simulations over a range of ignition conditions consistent with the progenitor's thermal and convective structure assuming multiple ignition points. To compare the results from these hybrid WD stars to previous results from C–O WDs, we construct a set of C–O WD models with similar properties and similarly simulate a suite of explosions. We find that despite significant variability within each suite, trends distinguishing the explosions are apparent in their ${}^{56}\mathrm{Ni}$ yields and the kinetic properties of the ejecta. We compare our results with other recent work that studies explosions from these hybrid progenitors.

79 ASTRONOMY AND ASTROPHYSICS↗

Dependence of Dust Formation on the Supernova Explosion

We investigate the properties, composition, and dynamics of dust formation and growth for a diverse set of core-collapse supernovae (CCSNe), with 15, 20, and 25 M ⊙ progenitor masses, explosion energies ranging from 0.5 to 120 foe, and varied engine type. These explosions are evolved with a 1D Lagrangian hydrodynamics code out to a minimum of 1157 days to model the ejecta as it expands and cools. A multigrain dust nucleation and growth model is applied to these results. We find that higher explosion energies lead to an earlier onset of dust formation, smaller grain sizes, and larger silicate abundances. Further, we see that nuclear burning during the explosion leads to enhanced formation of silicate dust. Finally, we build composite models from our suite to predict the efficiency of CCSN dust production as a function of metallicity.

79 ASTRONOMY AND ASTROPHYSICS↗

Black Hole Formation Accompanied by the Supernova Explosion of a 40 M ⊙ Progenitor Star

Abstract We have simulated the collapse and evolution of the core of a solar-metallicity 40 M ⊙ star and find that it explodes vigorously by the neutrino mechanism, despite its very high “compactness.” Within ∼1.5 s of explosion, a black hole forms. The explosion is very asymmetrical and has a total explosion energy of ∼1.6 × 10 51 erg. At black hole formation, its baryon mass is ∼2.434 M ⊙ and gravitational mass is 2.286 M ⊙ . Seven seconds after black hole formation, an additional ∼0.2 M ⊙ is accreted, leaving a black hole baryon mass of ∼2.63 M ⊙ . A disk forms around the proto−neutron star, from which a pair of neutrino-driven jets emanates. These jets accelerate some of the matter up to speeds of ∼45,000 km s −1 and contain matter with entropies of ∼50. The large spatial asymmetry in the explosion results in a residual black hole recoil speed of ∼1000 km s −1 . This novel black hole formation channel now joins the other black hole formation channel between ∼12 and ∼15 M ⊙ discovered previously and implies that the black hole/neutron star birth ratio for solar-metallicity stars could be ∼20%. However, one channel leaves black holes in perhaps the ∼5–15 M ⊙ range with low kick speeds, while the other leaves black holes in perhaps the ∼2.5–3.0 M ⊙ mass range with high kick speeds. However, even ∼8.8 s after core bounce the newly formed black hole is still accreting at a rate of ∼2 × 10 −2 M ⊙ s −1 , and whether the black hole eventually achieves a significantly larger mass over time is yet to be determined.

Astronomy & Astrophysics↗

Physics-driven Explosions of Stripped High-mass Stars: Synthetic Light Curves and Spectra of Stripped-envelope Supernovae with Broad Light Curves

Stripped-envelope supernovae (SESNe) represent a significant fraction of core-collapse supernovae, arising from massive stars that have shed their hydrogen and, in some cases, helium envelopes. The origins and explosion mechanisms of SESNe remain a topic of active investigation. In this work, we employ radiative-transfer simulations to model the light curves and spectra of a set of explosions of single, solar-metallicity, massive Wolf–Rayet stars with ejecta masses ranging from 4 to 11 M ⊙ , which were computed from a turbulence-aided and neutrino-driven explosion mechanism. We analyze these synthetic observables to explore the impact of varying ejecta mass and helium content on observable features. We find that the light curve shape of these progenitors with high ejecta masses is consistent with observed SESNe with broad light curves but not the peak luminosities. The commonly used analytic formula based on rising bolometric light curves overestimates the ejecta mass of these high-initial-mass progenitor explosions by a factor of up to 2.6. In contrast, the calibrated method by Haynie et al., which relies on late-time decay tails, reduces uncertainties to an average of 20% within the calibrated ejecta mass range. Spectroscopically, the He I 1.083 μm line remains prominent even in models with as little as 0.02 M ⊙ of helium. However, the strength of the optical He I lines is not directly proportional to the helium mass but instead depends on a complex interplay of factors such as the 56 Ni distribution, composition, and radiation field. Thus, producing realistic helium features requires detailed radiative transfer simulations for each new hydrodynamic model.

79 ASTRONOMY AND ASTROPHYSICS↗

Presupernova O–C Shell Mergers Could Produce More 44 Ti than the Explosion

The formation of 44 Ti in massive stars is thought to occur during explosive nucleosynthesis; however, recent studies have shown it can be produced during O–C shell mergers prior to core collapse. We investigate how mixing according to 3D macrophysics derived from hydrodynamic simulations impacts presupernova O–C shell merger nucleosynthesis and if it can dominate explosive supernova production of 44 Ti and other radioactive isotopes. We compare a range of observations and models of explosive 44 Ti yields to preexplosive multizone mixing–burning nucleosynthesis simulations of an O–C shell merger in a 15 M ⊙ Z = 0.02 stellar model with mixing conditions corresponding to different 3D hydrodynamic mixing scenarios. Radioactive species produced in the O shell have a multidex spread in preexplosive yield predictions across different 3D mixing scenarios of 1.54 and 2.14 dex on average, depending on mass cut. 44 Ti has the largest spread of 4.78 and 4.81 dex depending on mass cut. Further, we show that the preexplosive production of 44 Ti can be larger than the explosive production of models and can match observations. Our results also show that 3D mixing physics enhances 44 Ti in 1D models without modifying 56 Ni yields. We conclude that quantitative predictions of 44 Ti and other radioactive species more broadly require an understanding of the 3D hydrodynamic mixing conditions present during the O–C shell merger.

Issa, Joshua [University of Victoria, BC (Canada);↗

Explosives tester

An explosives tester that can be used anywhere as a screening tool by non-technical personnel to determine whether a surface contains explosives. First and second explosives detecting reagent holders and dispensers are provided. A heater is provided for receiving the first and second explosives detecting reagent holders and dispensers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Inspection tester for explosives

An inspection tester that can be used anywhere as a primary screening tool by non-technical personnel to determine whether a surface contains explosives. It includes a body with a sample pad. First and second explosives detecting reagent holders and dispensers are operatively connected to the body and the sample pad. The first and second explosives detecting reagent holders and dispensers are positioned to deliver the explosives detecting reagents to the sample pad. A is heater operatively connected to the sample pad.

Haas, Jeffrey S↗

Method and apparatus for detecting explosives

A method and apparatus is provided for detecting explosives by thermal imaging. The explosive material is subjected to a high energy wave which can be either a sound wave or an electromagnetic wave which will initiate a chemical reaction in the explosive material which chemical reaction will produce heat. The heat is then sensed by a thermal imaging device which will provide a signal to a computing device which will alert a user of the apparatus to the possibility of an explosive device being present.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Apparatus and methods for real-time detection of explosives devices

The present disclosure relates, according to some embodiments, to apparatus, devices, systems, and/or methods for real-time detection of a concealed or camouflaged explosive device (e.g., EFPs and IEDs) from a safe stand-off distance. Apparatus, system and/or methods of the disclosure may also be operable to identify and/or spatially locate and/or detect an explosive device. An apparatus or system may comprise an x-ray generator that generates high-energy x-rays and/or electrons operable to contact and activate a metal comprised in an explosive device from a stand-off distance; and a detector operable to detect activation of the metal. Identifying an explosive device may comprise detecting characteristic radiation signatures emitted by metals specific to an EFP, an IED or a landmine. Apparatus and systems of the disclosure may be mounted on vehicles and methods of the disclosure may be performed while moving in the vehicle and from a safe stand-off distance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Method for selective detection of explosives in mass spectrometer or ion mobility spectrometer at parts-per-quadrillion level

A method for selective detection of volatile and non-volatile explosives in a mass spectrometer or ion mobility spectrometer at a parts-per-quadrillion level without preconcentration is disclosed. The method comprises the steps of ionizing a carrier gas with an ionization source to form reactant ions or reactant adduct ions comprising nitrate ions (NO.sub.3.sup.-); selectively reacting the reactant ions or reactant adduct ions with at least one volatile or non-volatile explosive analyte at a carrier gas pressure of at least about 100 Ton in a reaction region disposed between the ionization source and an ion detector, the reaction region having a length which provides a residence time (tr) for reactant ions therein of at least about 0.10 seconds, wherein the selective reaction yields product ions comprising reactant ions or reactant adduct ions that are selectively bound to the at least one explosive analyte when present therein; and detecting product ions with the ion detector to determine presence or absence of the at least one explosive analyte.

47 OTHER INSTRUMENTATION↗

Explosives mimic for testing, training, and monitoring

Additive Manufacturing (AM) is used to make mimics for explosives. The process uses mixtures of explosives and matrices commonly used in AM. The explosives are formulated into a mixture with the matrix and printed using AM techniques and equipment. The explosive concentrations are kept less than 10% by wt. of the mixture to conform to requirements of shipping and handling.

36 MATERIALS SCIENCE↗

Inspection tester for explosives

An inspection tester that can be used anywhere as a primary screening tool by non-technical personnel to determine whether a surface contains explosives. It includes a body with a sample pad. First and second explosives detecting reagent holders and dispensers are operatively connected to the body and the sample pad. The first and second explosives detecting reagent holders and dispensers are positioned to deliver the explosives detecting reagents to the sample pad. A is heater operatively connected to the sample pad.

Haas, Jeffrey S↗

The Effect of Annealing on the Properties of AW5754 Aluminum Alloy-AZ31B Magnesium Alloy Explosively Welded Bimetals

Explosive welding of AW5754 aluminum alloy to AZ31B magnesium alloy was performed. AW5754 was proposed as a flyer plate. A parallel setup was used during explosive welding. The annealing of AW5754/AZ31B composite plate at 250, 300 and 350 °C for 2, 3, 4 and 5 h was performed after explosive welding. Bimetals were characterized by regular wavy interface. Annealing resulted in the creation of intermetallic compounds (IMCs). The increase in the thickness of IMC interfacial layer was observed with increasing of annealing temperature and time. IMC layer of highest thickness was recorded after annealing at 350 °C for 5 h and averaged 67 µm. EDS analysis showed that the interfacial layer close to AW5754 alloy was formed by Al{sub 3}Mg{sub 2} IMC, and interfacial layer adjacent to the AZ31B alloy consisted of Mg{sub 17}Al{sub 12} IMC. Bright particles were spread at the AW5754-Al{sub 3}Mg{sub 2} IMC interface. Rise in the microhardness at the interface of produced bimetal was associated with work hardening. Microhardness values increased to 218 HV0.025 after annealing process due to IMCs present at the interface. Decrease in microhardness in locations close to the IMC interfacial layer was found after heat treatment due to recrystallization. The bimetal tensile strength reached 120 MPa. The annealing resulted in decrease in the bimetal tensile strength.

36 MATERIALS SCIENCE↗

Some Observations About the Drop-weight Explosive Sensitivity Test

The apparent simplicity of the drop-weight apparatus for explosive sensitivity testing hides the reality that it is actually a complex integrated test of both ignition and growth of deflagration. Although the drop-weight test is undeniably a useful screening test for explosive properties, a misunderstanding of the technique’s limitations has blinded many researchers to its limited wider applicability. This monograph discusses how the test actually works, the significant engineering difficulties with standardization between machines, which types of explosives are suited to the test and which are not, and finally offers a few suggestions for alternatives when a more quantified understanding of a material’s response is required for other applications.

36 MATERIALS SCIENCE↗

Remediating explosive-contaminated groundwater by in situ redox manipulation (ISRM) of aquifer sediments

In situ chemical reduction of clays and iron oxides in subsurface environments is an emerging technology for treatment of contaminated groundwater. Our objective was to determine the efficacy of dithionite-reduced sediments from the perched Pantex Aquifer (Amarillo, TX) to abiotically degrade the explosives RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine), HMX (octahydro-1,3,5,7-tetranitro- 1,3,5,7-tetrazocine), and TNT (2,4,6-trinitrotoluene). The effects of dithionite/buffer concentrations, sediments-solution ratios, and the contribution of Fe(II) were evaluated in batch experiments. Results showed that reduced Pantex sediments were highly effective in degrading all three high explosives. Degradation rates increased with increasing dithionite/buffer concentrations and soil to solution ratios (1:80–1:10 w/v). When Fe(II) was partially removed from the reduced sediments by washing (citrate-bicarbonate buffer), RDX degradation slowed, but degradation efficiency could be restored by adding Fe(II) back to the treated sediments and maintaining an alkaline pH. These data support in situ redox manipulation as a remedial option for treating explosive-contaminated groundwater at the Pantex site.

54 ENVIRONMENTAL SCIENCES↗