Geothermal Thermoelectric Generation (G-TEG) with Integrated Temperature Driven Membrane Distillation and Novel Manganese Oxide for Lithium Extraction

Southern Research Institute (Southern) teamed with partners Novus Energy Technologies (Novus), Carus Corporation (Carus), and Applied Membrane Technology, Inc. (AMT) to develop an innovative Geothermal ThermoElectric Generation (G-TEG) system specially designed to both generate electricity and extract high-value lithium (Li) from low-temperature geothermal brines. The process combined five modular technologies including – silica removal, nanofiltration (NF), membrane distillation (MD), Mn-oxide sorbent for Li recovery, and TEG. This project provides a proof of concept for each of these technologies. The first step in the process is silica precipitation through metal addition and pH adjustment to prevent downstream scaling in membrane processes. Next, the geothermal brine is concentrated with the first of a two stage MD system. The first stage MD system is made of a high-temperature material to withstand geothermal brine temperatures up to 150C.° The first stage MD is integrated with a G-TEG module for simultaneous energy generation. The release of energy from the MD permeate drives heat transfer across the TE module, producing electricity. The first stage MD concentrate is then treated utilizing an NF system to remove Ca 2+ and Mg 2+ . The NF concentrate will be disposed in the well by reinjection. The NF permeate undergoes concentration in a second stage of MD (polymeric material) to further concentrate Li in the NF permeate and enhance the efficiency of the downstream Li recovery process utilizing a Mn-oxide sorbent. Permeate from both the stages of the MD can be beneficially utilized as the permeates will contain less contaminants than the feed water. The concentrated geothermal brines are then contacted with the Mn-oxide sorbent. After Li from the geothermal brine is adsorbed on the sorbent, HCl is then utilized to regenerate the sorbent and recover the Li. The research and development project showed that the Si removal goal (>80%) could be achieved by increasing the pH of the brine and adding Fe 3+ under several scenarios. The NF was also successful in achieving significant Ca 2+ and Mg 2+ removal (~80%) while retaining most Li in the permeate for high strength brines. MD experiments showed that geothermal brines could be significantly concentrated with little fouling due to pre-treatment.

15 GEOTHERMAL ENERGY↗

Advanced, Energy-Efficient Hybrid Membrane System for Industrial Water Reuse

In the U.S. manufacturing sector, current industrial water use practices are energy-intensive and utilize and discharge high volumes of waters, rendering them not sustainable especially in light of the growing scarcity of suitable water supplies. To help address this problem, the goal of this project was to develop an advanced, cost-effective, hybrid membrane-based water treatment system that can improve the energy efficiency of industrial wastewater treatment while allowing at least 50% water reuse efficiency. This hybrid process would combine emerging Forward Osmosis (FO) and Membrane Distillation (MD) technology components into an integrated FO-MD system that can beneficially utilize low-grade waste heat (i.e., T < 450 °F) in industrial facilities to produce distilled-quality product water for reuse. In this project, laboratory-, bench-, and pilot-scale experiments on the hybrid FO-MD system were conducted for industrial wastewater treatment. It was demonstrated at laboratory, bench, and pilot scales that FO-MD membrane technology can concentrate brine to very high total dissolved solids (TDS) levels (>200,000 ppm) that are at least 2.5 times higher than the TDS level to which RO can achieve. In laboratory testing, currently available FO and MD membranes were tested to select for high-performing membranes with high salt rejection and high water flux. Multiple FO membrane/draw-salt solution combinations that gave high water flux with higher than 98% salt rejection were also identified. Reverse draw-salt fluxes were observed to be much lower for divalent salts than for monovalent salts. MD membranes were identified that had 99.9+% salt rejection and water flux as high as 50-90 L/(m 2 ·h) for flat-sheet membranes and >20 L/(m 2 ·h) for hollow fibers. In bench-scale testing, a single unit of commercially available FO and MD membrane modules were evaluated for continuous, integrated operation. Using the laboratory- and bench-scale test data, numerical modeling was performed on the FO and MD processes to estimate engineering parameters for a larger-scale pilot unit. Based on the experimental studies and modeling results, a pilot-scale, integrated FO-MD prototype unit was designed and built for trailer-mounted operation. This prototype system was fed real industrial wastewater, which could not be further treated by conventional technologies, from an oil production facility and was successfully operated for over 15 weeks without major stoppage. About 90% water recovery was possible, while concentrating the TDS from 12,000 ppm up to 190,500 ppm. The FO-MD prototype rejected most wastewater contaminants while producing water with <300 ppm TDS, even when the feed TDS was higher than 150,000 ppm. No chemical cleaning was necessary during the pilot testing period. Flushing the system with dechlorinated tap water was sufficient to reset the membranes for the next set of test conditions. Pilot performance and membrane autopsy showed that, even though the feed was concentrated more than 10 times, membrane fouling was unnoticeable and no defects were detected on the FO and MD membrane surfaces. This project demonstrated the technical feasibility of the hybrid FO-MD process by taking water already treated to the limit with the highest level of current technologies and further concentrating it 10-fold by using mostly low-cost materials. Because no membranes suitable for full-scale plant applications are available at present, economical feasibility of the hybrid technology is still uncertain, but it is expected that broader industry participation can further reduce FO-MD process costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanford Waste End Effector Phase I Test Report

This test plan describes the Phase 1 testing program of the Hanford Waste End Effector (HWEE) at the Washington River Protection Solutions’ Cold Test Facility (CTF) using a Pacific Northwest National Laboratory (PNNL)-designed testing setup. This effort fulfills the informational needs for initial assessment of the HWEE to support Hanford single-shell tank A-105 retrieval. This task will install the HWEE on a PNNL-designed robotic gantry system at CTF, install and calibrate instrumentation to measure reaction forces and process parameters, prepare and characterize simulant materials, and implement the test program. The tests will involve retrieval of water, sludge, and hardpan simulants to determine pumping rate, dilution factors, and screen fouling rate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Efficient Clothes Dryer with IR Heating and Electrostatic Precipitator

The project goal was to develop a revolutionary energy saving technology for residential clothes drying. The team developed an IR (infrared) heating system and NESP (Nebulizer and Electro-Static Precipitator) for integration into a ventless clothes dryer. The proposed technology addresses two of the major inefficiencies in current electric vented dryers by providing effective energy transfer for the removal of the water and recapture of the vapor latent heat. The IR heaters operating in the mid wave (2.5-10um) are very efficient as they target the 3-micron peak absorption of the water molecule. This allows direct energy absorption, unlike conventional element heaters where heat is transferred by convection. The low power NESP removes water vapor from the exhausted stream and recaptures the latent heat in the ESP (Electro-Static Precipitator) exchanger section. This allows the warm dry air to be recirculated back into the drum for additional efficiency savings. The remaining majority of the dryer hardware stays the same. Summing the efficiency gain from the two subcomponents we anticipated the EF (Efficiency Factor) to exceed the goal of 4.04. EF is obtained by dividing the weight (lbs) of water removed by the energy (kWhr) used, where the test load size is 8.45 lbs of bone dry clothing wetted to 57.5% or 4.8lbs of water, and dried to a remaining moisture content of 2.5-5%. Additional benefits include not having to recondition (heat or cool) the large amounts of make-up air to replace the air exhausted by a vented dryer. It was anticipated that the NESP/heat exchanger would be the most challenging and highest risk element in the program. Therefore, the team focused their efforts during Phase 1 of the program on the design, construction, testing, and optimization of the NESP/heat exchanger. At the end Phase 1, the team compared the performance of the NESP/heat exchanger with the system level requirements and made a Go/No-Go decision on proceeding with the second portion of the program. Phase 2 of the program was structured to develop the IR heating system and then integrate it and the NESP/heat exchanger into a residential clothes dryer prototype for final testing. The proposed technology utilizes heat recovery which is known to have the biggest impact on dryer efficiency. The two current mainstream recovery approaches are air to air exchangers and heat pump condenser systems. Air to air exchanges can be very efficient but require large surface areas which are prone to fouling from uncaptured lint. Dryers based on heat pump condenser recovery systems have shown efficiency improvements of 20–60% and are commercially available. The issue with a heat pump condenser approach is the added cost, as typical prices are twice that of standard vented dryers and they are only available in small to medium capacities. The energy factor (EF) for these systems is 5.50 to 6.88 pounds/kWh compared to conventional dryers at 2.75 to 3.67 pounds/kWh. The efficiency improvements for the proposed technology come from the use of IR heating and the NESP. As the concept is in its infancy, and these improvements were difficult to predict without experimental data, assumptions were made based on available literature. IR radiant drying times, when compared to convection, are typically 30% less. This is a result of the fact that radiant energy heats directly and is absorbed at and below the surface, unlike convection heating, that must conduct the heat through the boundary film of air at the clothes surface and rely on wicking of the moisture to the surface. The second area of improvement comes from the NESP. The NESP operation is as follows: 1. Highly charged, micron sized, droplets of water are injected into the dryer exhaust by the Nebulizer. 2. These charged droplets attract water molecules and continue to grow in size, until losing their charge. During this process, latent heat is rejected back into the air stream. 3. The large droplets enter the ESP, where they are recharged and drawn to the ESP wall, to be extracted at the bottom of the ESP. The warm dry air is then recirculated back into the dryer. The proposed technology, at the time of the proposal submission was estimated to have an EF of 4.79. At program completion we have designed, built, tested, integrated and optimized the proposed technologies into a prototype “high efficiency” residential clothes dryer. Testing of the integrated prototype dryer provided insight into the technical effectiveness and economic feasibility of the proposed technologies. The program has the potential of greatly impacting energy savings. The predicted EF of the proposed technology is 4.79, yielding an energy savings of 42% when compared to conventional electric vented dryers. Given there are approximately 84 million dryers in the US consuming ~64 billion kWh per year, a net savings of 27 billion kWh per year or 0.092 quads could be realized. Since the dryer is not vented, make up air from the room is not needed, adding an additional savings of ~1kWh per load, or 23.8 billion kWh per year. In addition, it is envisioned that the proposed ESP, when successful, would potentially find applications in industrial and residential dehumidification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SNS Resonance Control Cooling Systems and Quadrupole Magnet Cooling Systems DIW Chemistry

This report focuses on control of the water chemistry for the Spallation Neutron Source (SNS) Resonance Control Cooling System (RCCS)/Quadrupole Magnet Cooling System (QMCS) deionized water (DIW) cooling loops. Proper cooling-water chemistry is essential to preserving the DTL and CCL structures during their design lifetime. Appropriate water chemistry will protect cooling-water passages and brazed joints of the structure from erosion, corrosion, and fouling. The RCCS/QMCS DIW chemistry is managed by sidestreams built into the cooling loops; chemicals are not used. Data collected from spring 2013 through spring 2016 are discussed, and an operations regime is recommended. During the evaluation period, the pH, dissolved oxygen, and water resistivity of the cooling water were observed. The data were collected by instruments mounted on mobile chemistry carts, which were moved from one RCCS/QMCS DIW skid to another. During data reading, operational corrections were done on the polishing loops to improve the water chemistry regime. Therefore some trends changed over time. It was found that the RCCS operates with an average pH of 7.24 for all lines (from 7.0 to 7.5, slightly alkaline), the average low dissolved oxygen is in the area of < 36 ppb, and the main loop average resistivity of is > 14 MΩ-cm. The QMCS was found to be operating in a similar regime, with a pH of about 7.5 (slightly alkaline), low dissolved oxygen in the area of < 45 ppb, and main loop resistivity of 10 to 15 MΩ-cm. It is recommended that the cooling loops operate in a regime in which the water has a resistivity that is as high as achievable, a dissolved oxygen concentration that is as low as achievable, and a neutral or slightly alkaline pH. An RCCS/QMCS chemistry guidance document published in May 2017 describes and standardizes the methods and practices for water chemical treatment for the SNS RCCS and QMCS. It is very difficult to accurately measure the pH, dissolved oxygen, and water resistivity in highly pure water. Therefore, a regularly scheduled calibration program will be established for the instruments. Recommendations are given at the end of the report on how to run the RCCS/QMCS cooling water chemistry. Chemical analysis of the material trapped by the polishing loop prefilters is conducted twice a year. The analysis and its benefits are described in Chapter 9.

42 ENGINEERING↗

Magnetostrictive Cold Spray Sensor Feasibility Assessment

Ultrasound sensors and inspection systems are frequently used to generate acoustic waves in metal structures capable of detecting and characterizing cracks, pits, erosion, inclusions, weld anomalies, and other material and structural features. One significant problem with piezoelectric transducers is the difficulty to achieve good coupling between the transducer and the surface being examined. This is particularly true in harsh conditions with high temperatures, cyclical hot and cold temperatures, highly radioactive fields found near nuclear reactors or spent nuclear fuel, caustic or corrosive fluids, and other extreme environmental conditions, as well as in long-term monitoring applications where repair or replacement of the sensor is difficult or expensive. Typically, coupling between the surface and the transducer is achieved with water, gel, grease, viscous shear coupling material, or pressure, which might not be possible or appropriate for long-term applications in which the impedance -matching materials wear away, evaporate, or simply stop functioning due to changes in surface conditions. Fluid couplings can evaporate or drain away from the transducer-substrate interface; glue- based couplings may foul or fail and are notoriously unreliable at high temperatures and in radioactive environments. This work explores the behavior of a magnetostrictive cold-spray patch that is metallurgically bonded to a stainless steel inspection target surface, and compares it to the performance of a standard adhesively-bonded ferrous-cobalt magnetostrictive strip solution. Cold-spray is a coating process where 10 –100 micron diameter powdered metal is accelerated to Mach 2 to Mach 3 (2–3 × speed of sound) and impacted on the surface to be coated. Each powder particle forms a kinetic bond with the substrate or other coating particles to produce a metallurgically bonded layer. If the powder is nickel or cobalt with high magnetostrictive coefficients, this surface can serve as the base of a magnetostrictive sensor suitable for crack or pitting-damage inspection and monitoring that is not subject to temporal or environmental degradation.

47 OTHER INSTRUMENTATION↗

Crossflow Filtration of Hanford Tank AP-105 Supernatant

A small-scale test platform to demonstrate the solids filtration, Cs removal, and low-activity waste (LAW) vitrification was constructed and installed at the Pacific Northwest National Laboratory (PNNL) 325 Building. Bench scale testing was conducted to demonstrate cross flow filtration using the cells unit filter (CUF) on approximately 14 liters of 241-AP-105 feed to support the confirmation of the Low-Activity Waste Pretreatment System (LAWPS) equipment performance and design basis for entrained solids removal process. Despite the low solids content (~16 ppm) of the AP-105 feed, significant fouling of the filter was observed that required backpulsing of the filter to maintain the permeate flux within the LAWPS baseline design rate. The improvement from backpulsing was significant, but transitory, and lasted a few hours. Increasing the transmembrane pressure was shown to have limited impact on the permeate flux in terms of magnitude and duration, especially compared with backpulsing. Because LAWPS must operate three to eight days to throughput requirements, testing demonstrated that backpulsing or chemical cleaning may need to be done every 7 to 14 hours when processing feed from AP-105. Because of this, backpulsing capability is strongly recommended for the baseline design. The LAWPS prototypic filter cleaning was demonstrated at the end of testing and was shown to be very effective as it largely restored the filter permeability to near pre-test conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Pump-and-Treat System Impacts on 200 West Aquifer Conditions

The 200 West P&T system is one of the key components of the final remedy selected for the 200-ZP-1 Operable Unit (OU), and the interim remedial action selected for 200-UP-1 OU at the Hanford Site. In addition, the facility has been receiving water from several other sources, such as 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. It is anticipated that the P&T system will continue to receive water from other sources, which may include Modular Storage Unit (purge) water, groundwater near the Waste Management Area C, and Gable Gap. Furthermore, maintaining the injection capacity of the system has been a significant issue since the facility startup in 2012. Fouling issues at the injection wells have necessitated frequent well redevelopment, resulting in decrease in injection capacity and the need to construct new injection wells—with significant effects on system performance and operational costs. Given the evolving nature of treatment plant effluent due to changes in influent, combined with issues observed at the injection wells, it is important to understand the impacts of the P&T operations on the 200 West aquifer where the treated water is injected. This study aims at determining these impacts and providing a quantitative evaluation of aquifer capacity for both current and future conditions. This information will provide a technical basis for decisions related to the P&T system operations that support remedy optimization efforts and short- and long-term remedy decisions related to multiple OUs in the Central Plateau.

Demirkanli, Deniz I.↗

Crossflow Filtration of LAWPS Simulants

The Low-Activity Waste Pretreatment System (LAWPS) will employ crossflow filtration (CFF) to separate solids from radioactive wastes. Design verification of CFF unit operations will involve engineering-scale demonstrations of the efficacy of liquid-solid separations with low-activity waste (LAW) simulants. Before execution of integrated engineering-scale verification tests, the LAW simulants developed to support design verification activities are to be evaluated in a laboratory-scale CFF apparatus to demonstrate simulant suitability, to help refine engineering-scale filtration and filter cleaning strategies prior to implementation, and to identify any anomalous filtration behaviors that could impact the conduct-of-operations at the engineering-scale test facility. This report provides the bench-scale test results for the four LAWPS simulants developed to support integrated testing and of the eight fouling simulants selected to evaluate the sustainability of LAWPS filtration and the effectiveness of LAWPS flux recovery technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dead-End Filtration and Crystalline Silicotitanate Cesium Ion Exchange with Hanford Tank Waste AW-102

The Direct Feed Low-Activity Waste (DFLAW) flowsheet provides for the initial production of immobilized low-activity waste (ILAW) by feeding low-activity waste (LAW) directly from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW facility for immobilization. Prior to the transfer of feed to the WTP LAW facility, tank supernatant waste will be pretreated by the Tank Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18E-5 Ci 137Cs/mole of Na). This pretreatment facility will filter the waste to remove suspended solids and remove cesium from the waste stream through ion exchange. Bench-scale filtration testing of 7.4 liters of diluted of AW-102 supernate was conducted using dead-end filtration in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. A Mott 70-mm disc filter (media grade 5) was used to capture solids. The filter area was adjusted to 2.2 in2 to match the planned TSCR supernate process volume to surface area ratio. There was no indication of filter fouling and no recoverable solids were observed on the filter. Ion exchange testing with the filtered, diluted AW-102 supernatant was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Lot number 8056202-999). The column testing operations were prototypic to the intended Low-Activity Waste Pretreatment System operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~1.8 bed volumes per hour (BV/h). After 88.6 BVs of feed processing, the volume in the feed bottle dropped below the inlet tube and the lead column fluid headspace was displaced with air. Feed processing was suspended while a new column was prepared and installed into the lead position. A total of 450 BVs of diluted AW-102 feed were processed through the new lead column; only 4.3% Cs breakthrough was achieved. This volume of feed was insufficient to generate useful Cs loading information without extrapolation. A straight-line extrapolation was used to determine the 50% breakthrough of the lead column and contract limit breakthrough from the lag. The values were found to be 1200 BVs and 930 BVs, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced supercritical carbon dioxide cycles

The supercritical carbon dioxide cycle (sCO2) has been chosen as the most promising cycle to meet the SunShot goals with a power block that has the potential to achieve thermal efficiencies of 50+% with a turbine inlet temperature of 720 o C. While this cycle has significant potential, it is a fairly new cycle and therefore the costs and performance of the cycle are not known to the level required for detailed economic analysis. There are also multiple cycle configurations that may be used and the choice of configuration could depend on size, cost constraints, efficiency, cooling mode, O&M costs, etc. Each of the variants has particular advantages and drawbacks that have to be understood. The most cost effective way to understand these variants is to use models that allow us to predict the performance of the cycles linked to the heat source (solar thermal energy). In order to do this these models, need to be developed and improved to better predict the costs and performance of the cycle. One of the issues identified with the supercritical Brayton cycle is the fact that a large amount of internal heat exchange is required in order for it to realize its efficiency potential. To address this, recuperators of the Printed Circuit Heat Exchanger (PCHE) design have been primarily considered. While PCHEs are fairly advanced technology and have significant potential there are several drawbacks associated with them. The first being their cost; it is estimated that the two recuperators in a recompression Brayton cycle will cost more than 30% of the entire power block. Another major issue is the in service performance and lack of ability to repair or easily clean the recuperators. If there is a defect in a diffusion bond, fouling or plugging of the channels or mechanical damage due to rapid thermal transient then the entire PCHE may need to be replaced. The third issue is the lack of data and information on the performance of PCHEs at the scale that would be required even for a small 10 MWe plant. To date PCHE heat exchangers have not been constructed at this size and it is necessary to have multiple modules headered together in order to be able to recuperate up to the 40 MWth required in even a small, 10 MWe plant.

14 SOLAR ENERGY↗

Characterization and CST Batch Contact Equilibrium Testing of Aged TCCR Tank 10H Batch 1A and 2 Process Supernate Samples

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs-137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium saltcake solids) within the tank followed by at-tank ion exchange column treatment. Previous equilibrium batch contact tests conducted in the SRNL Shielded Cells laboratory and associated analyses indicated that CST cesium removal performance was lower than predicted by ZAM modeling for TCCR Tank 10H Production Supernate Batch 1A. An average cesium distribution coefficient of 1,948 mL/g which corresponds to 94.1% Cs + removal was observed for Batch 1A supernate at 38 °C in January of 2019 using laboratory pretreated IONSIV™ R9120-B a CST from Lot #209900034 (predominant TCCR CST batch) at a phase ratio of 122 mL/g. This cesium loading was approximately 32% lower than model predictions, presumably due to ion exchange competition or fouling associated with alkaline earth or transition metals present in the solutions at low levels. The current testing was designed to: 1) evaluate whether supernate compositional changes during storage would result in improved cesium removal performance with CST, and 2) assist in media selection and handling protocols for future TCCR columns by evaluating several CST manufacturer batches as well as samples of one CST batch which had been pretreated using two different methods (field and laboratory methods).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Slag Management of Carbon Feedstock Used in Gasification FY17 TCF between Eastman Chemical and NETL (Final Report)

NETL, in collaboration with Eastman Chemical Corp (Kingsport, TN), targeted the joint evaluation and refinement of a slag management program developed by NETL (NETL IP, patent applied for) to control gasifier slag properties formed from ash in individual or combinations of different coal-based carbon feedstock materials and specific slag modifiers used in gasification. Slag forms from mineral or organic-metallic impurities in the carbon feedstock that melt at the high temperatures of gasification, coalescing to form a liquid (slag) that must flow from the gasifier. Slag additives, also known as slag modifiers, are often added to the carbon feedstock to modify the ash chemistry and achieve desired slag flow properties at target temperatures used in gasification. If slag does not flow from a gasifier, its buildup within the gasification chamber will cause either gasifier shutdown to physically remove the slag (consuming time and damaging the protective refractory lining), or the gasification temperature must be increased to lower slag viscosity so it can flow from the gasifier, leading to greater refractory wear/corrosion, along with increased fouling and downstream component wear. Because of these issues, gasification is typically targeted at the lowest temperature possible where slag will flow in a controlled manner (a temperature range called T100 for the lowest temperature, with T250 being the highest temperature where the slag has achieved the desired fluidity). That temperature range also needs to yield a desired syngas composition, highlighting the importance of knowing and being able to control carbon feedstock slag viscosity and the temperature of thermal breakdown of the carbon feedstock. Slag viscosity varies with changes in the gasification chamber temperature, oxygen partial pressure, and slag chemistry. The slag model work with Eastman Chemical targeted predicting and controlling molten coal ash slag behavior at specific gasification conditions. The final goal of the refined model was to develop/refine the NETL slag model so a gasifier operator would be able to predict slag behavior prior to purchasing or using a carbon feedstock and control slag properties once a carbon feedstock is being gasified, allowing a gasifier user to determine what mineral additives or blends of different carbon materials would be needed to achieve desired slag properties at targeted gasification conditions. For a given carbon feedstock and desired gasification condition, the actual gasification cost and slag behavior would be able to be predicted using the slag management program in advance of purchasing or using the carbon feedstock – allowing accurate control of slag ash behavior in real time. As part of the TCF project work with Eastman Chemical, the viscosity of several ash compositions of interest to them would be measured and used to populate the slag model, along with a large database of historical slag temperature, chemistry, and viscosity information they possess – information that would in-crease the predictive accuracy of the slag management model with slag ash chemistry of interest to them. As part of the model evaluation and refinement, the predictive model and its database will be installed on computers at Eastman Chemical and used to manage slag properties in a gasifier during real-time operation of their gasifier. In summary, success of the slag management program at Eastman Chemical would support its use by other gasifier operators to manage slag chemistry and properties over other desired gasification temperature ranges, allowing greater process control and efficiency of their carbon feedstock conversion during gasification.

01 COAL, LIGNITE, AND PEAT↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

White Paper to Justify the Use of Strip Effluent in the Defense Waste Processing Facility During Slurry Mix Evaporator Processing

At the request of Savannah River Remediation (SRR), a white paper was written to assess whether it would be acceptable to process Strip Effluent (SE) in both the Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) in the Defense Waste Processing Facility (DWPF) for the nitric-glycolic acid flowsheet. Savannah River National Laboratory (SRNL) experimental data and DWPF Sludge Batch 9 (SB9) process data was reviewed, looking at batches which included Precipitate Reactor Feed Tank (PRFT) and/or Strip Effluent Feed Tank (SEFT) feeds that led to long processing times. These batches were reviewed looking for processing problems such as melter feed trips, foamovers, heating rod or steam coil fouling, missed Reduction/Oxidation (REDOX) targets, and other process anomalies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal Header Design for Diffusion Bonded Heat Exchangers

Microchannel heat exchangers have seen increasing adoption in many high-pressure applications in recent decades but are subject to particulate fouling from the relatively small channel size compared to traditional designs. Typical cleaning methods require process shutdown, heat exchanger removal, cleaning, then reassembly. The objective of this project was to refine and transfer technology to enable header design improvements for Cleaning-in-Place (CIP), allowing for reduced/negligible process interruption for the cleaning process. The technology transfer was from Sandia National Laboratories (Sandia) to Vacuum Process Engineering, Inc. (VPE). This primary purpose of CIP was developed while considering channel flow uniformity and heat exchanger cost. The project phases were to 1) capture and define potential improvement options, 2) evaluate options with both simulation and experiments, and 3) transfer design knowledge to the industry partner. These efforts resulted in improved header designs from the first known focused effort in this area. The improved designs will help the entire microchannel heat exchanger field that has applications in supercritical CO 2 power cycles, hydrogen (fuel cell) vehicle fueling, liquified natural gas processing, and more.

42 ENGINEERING↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Microwave Plasma Flash Pyrolysis for Coal-to-Product Applications

Since 2010, the US coal industry has experienced a precipitous decline, with coal production volumes dropping by as much as 35% according to EIA. This decline is hardly surprising given that 90% of domestic coal use is allocated to electricity production: While coal generation supplied about 45% of the nation's power in 2010, its share is projected to fall to only 22% in 2020. Fortunately, alternative uses for coal as a feedstock rather than as energy source are available. Coal tar is an established feedstock for chemicals and high-value carbon products including carbon fiber and battery-grade graphites. At present, growth of these uses is constrained by the low availability, purity, and yields of currently available coal liquids, and high energy- and CO2-intensity of current methods of production (i.e. coking). Previously reported work conducted in a partnership with Pacific Northwest National Laboratory demonstrated technical and economic viability of flash pyrolysis of coal in a microwave plasma environment at bench scales targeting production of fuel feedstocks (synthetic oil). H Quest’s work since then indicated promise of microwave-derived coal liquids to be uniquely suited for the lower-cost production of carbon materials, including synthetic graphite, carbon fiber, and composites. Low bulk process temperatures, subsecond residence times, and ambient pressure operation enable small-scale deployment, reduce capital and operating costs, and suppress formation of impurities, including QI material, typical in conventional coal tars. With no inherent production of CO2 or water consumption, microwave plasma flash pyrolysis presents a viable route to the sustainable production of both platform chemicals and carbon-based materials. Most recently, H Quest developed a novel, ruggedized microwave plasma reactor, which departs from the proof-of-concept approach and addresses the problems typically encountered in scaling laboratory microwave plasma apparata (e.g. eliminating fragile quartz enclosures prone to coking and fouling). This reactor has been integrated with a 15kW microwave power supply, a pulverized coal injection system, and a product recovery system. A series of screening tests across a range of coals (including hv-, lv-bituminous and subbituminous PRB), entrainment gas flows and compositions and microwave energy inputs are performed to evaluate conversion rates within the novel, scaled-up system, confirm yields of liquid products, and to perform compositional (GC/MS and elemental) analyses of the products. Results of these tests will be presented and discussed.

Skoptsov, George↗