Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Cardiac R-wave detector

Cardiac R wave detector obtains the systolic contraction signal of the human heart and uses it as a reference signal for the heart-assist pump cycle. It processes the electrocardiac signal /QRS wave complex/ of the natural heart in a sequence of operations which essentially elimates all components from the input signal except the R wave.

Gebben, V. D.↗

Coronary flow and left ventricular function during environmental stress.

A canine model was used to study the effects of different environmental stresses on the heart and coronary circulation. The heart was surgically instrumented to measure coronary blood flow, left ventricular pressure, and other cardiovascular variables. Coronary flow was recorded by telemetry. Physiologic data were processed and analyzed by analog and digital computers. By these methods the physiologic response to altitude hypoxia, carbon monoxide, hypercapnia, acceleration, exercise, and the interaction of altitude hypoxia and carbon monoxide were described. The effects of some of these stresses on the heart and coronary circulation are discussed.

Erickson, H. H.↗

Physiological response to exercise after space flight - Apollo 7 to Apollo 11.

Exercise response tests were conducted preflight and postflight on Apollo missions 7 to 11. The primary objective of these tests was to detect any changes in the cardiopulmonary response to exercise that were associated with the space flight environment and that could have limited lunar surface activities. A heart-rate-controlled bicycle ergometer was used to produce three heart rate stress levels: 120 beats per minute for 6 minutes; 140 beats per minute for 3 minutes and 160 beats per minute per 3 minutes. Work load, blood pressure and respiratory gas exchange were measured during each stress level. Significant decreases were observed immediately postflight in the following dependent variables at a heart rate of 160 beats per minute: work load, oxygen consumption, systolic blood pressure, and diastolic blood pressure. No changes occurred in work efficiency at 100 watts or the ventilatory equivalent for oxygen at 2.0 liters per minute.

Rummel, J. A.↗

Skylab experiment M-092 - Results of the first manned mission

Blood pressure, heart rate, and percentage increase in leg volume were continuously recorded for the Inflight Lower Body Negative Pressure (LBNP) experiment conducted during the first manned Skylab mission. Data were collected over a 5-month preflight period as well as at approximately 3-day intervals throughout the mission. Individual variations in cardiovascular responses to LBNP during the preflight period continued to be demonstrated inflight, and measurements of the calf showed that a large volume of fluid was shifted out of the legs early in the flight. A much greater increase in leg volume occurred during inflight LBNP than in preflight tests. Resting heart rates tended to be low early in the flight and to increase slightly as it progressed, while resting blood pressure varied. The LBNP protocol was a greater stress inflight, and the tests had to be stopped early on three occasions due to impending syncopal reactions. Inflight LBNP responses seemed to predict the degree of postflight orthostatic intolerance. Postflight responses to LBNP during the first 48 hours were characterized by marked elevations in heart rate, instability in blood pressure, and considerably elevated systolic and diastolic pressures both at rest and during stress.

Johnson, R. L.↗

Elementary theory of synchronous arterio-arterial blood pumps

In the technique of arterio-arterial pumping, a volume of fluid is withdrawn from the aorta during systole and reinjected during diastole, thereby reducing the systolic pressure of the heart and adding energy to the systemic circulation. It is found that an upper bound for the effectiveness of such devices is given by a formula that considers stroke output of the unaided heart and the increment caused by the pump with a stroke. The division of effort of the pump between the reduction of pressure and the increase of flow depends on the physiological mechanical impedance of the heart. The total effect is, however, independent of the impedance.

Jones, R. T.↗

Program to study optimal protocol for cardiovascular and muscular efficiency

Two possible ways to minimize the effects of deconditioning in space are; To achieve a very high level of conditioning immediately prior to flight, and to provide a regimen in the capsule which will maintain a moderate degree of fitness. It was determined that running and riding a bicycle ergometer at comparable heart rates produced similar gains in physical fitness variables. It was found that subjects who exercised at a 180 heart rate made greater gains in physical fitness than did those exercising at a 140 or 160 heart rate. When the length of the workout was varied, subjects exercising sixty minutes per day made greater gains than those exercising twenty or forty minutes per day. Subjects who discontinued training slowly deconditioned, but a moderate level of fitness could be maintained by exercising at a pulse rate of 160 beats per minute for twenty minute periods three times a week. Subjects who overtrained twice daily to near exhaustion increased in fitness.

Olree, H. D.↗

High-resolution echocardiography

High resolution computer aided ultrasound system provides two-and three-dimensional images of beating heart from many angles. System provides means for determining whether small blood vessels around the heart are blocked or if heart wall is moving normally without interference of dead and noncontracting muscle tissue.

Nathan, R.↗

Features of cholinergic cardia regulation under conditions of hypokinesia

The features of cholinergic processes in the heart on the 4th, 8th, 16th and 30th days of hypokinesia were studied in experiments on 382 albino rats. It was shown that hypokinesia is attended by increased acetylcholine content in the atria, reduced choline acetyltransferase activity in the atria and ventricles and by increased activity of acetylcholinesterase in the ventricles and of pseudocholinesterase in both parts of the heart. The sensitivity of the heart to exogenic acetylcholine and to stimulation of the vagus nerve increases.

Markova, Y. A.↗

Fluid volumes changes induced by spaceflight

The blood volume (BV), plasma volume (PV), and extracellular fluid volume changes produced in crewmembers during spaceflights of 11-84 days were compared to changes after 14 or 28 days of bedrest. Spaceflight and bedrest produce approximately equal BV changes but the recorded PV change after spaceflight was less. However, the diurnal change in PV may explain the smaller decreases recorded after spaceflight. The cardiovascular deconditioning caused by spaceflight and bedrest was compared using the mean heart rate response to lower body negative pressure (LBNP) testing at -50 mmHg pressure. These tests show approximately equal LBNP produced heart rate changes after bedrest and spaceflight. A countermeasure which includes 4 hr of LBNP treatment at -30 mmHg and the ingestion of one l. of saline was studied and found capable of returning the heart rate response and the PV of bedrested subjects to control (prebedrest) levels suggesting that it would be useful to the crewmembers after a spaceflight.

Johnson, P. C.↗

Antibodies to myofibril antigens in cosmonauts after spaceflights

Serum samples obtained from 15 astronauts before and after spaceflights were studied with the use of the indirect immunofluorescent method. In seven astronauts antibodies to different elements of the human heart muscle appeared after flights. Strong and very strong luminescence of the elements of heart muscle tissue was detected in the astronauts after the third space flight. In a study of the sera on sections of bovine heart muscle tissue the reactions of the sera taken before and after flight were found to show no essential differences.

Tashpulatov, R. Y.↗

Instantaneous stroke volume by PDE during and after constant LBNP (-50 torr)

Six male subjects were exposed to -50 torr lower body negative pressure (LBNP) for 10 min while stroke volume was recorded beat by beat at regular intervals before, during and after release of LBNP. Stroke volume was calculated from the systolic velocity integral in the ascending aorta by pulsed Doppler echocardiography (PDE) and the cross sectional area of the vessel by M mode echocardiography. Changes in leg volume were recorded continuously and blood pressure was taken every minute. Stroke volume dropped by 51% of the control in the first 33 sec of LBNP and continued to decline slowly to -62% toward the end. Heart rate increased by 15% in the first 10 sec and was 22% above control at the end of exposure. The resulting cardiac output closely followed the course of stroke volume (-47% at 33 sec, -53% at 8 min) showing that the modest increase in heart rate did little to offset the drop in stroke volume. Leg volume increased markedly within the first 10 sec with a more gradual rise reaching +3.5% at the end. Upon sudden release of LBNP, leg volume dropped significantly during the first 3 sec simultaneously with an increase in stroke volume followed by a substantial decline in heart rate below the baseline.

Source record↗

Changes in cardiac output and tibial artery flow during and after progressive LBNP

A 3.0 MHz Pulsed Doppler velocity meter (PD) was used to determine blood velocities in the ascending aorta from the suprasternal notch before, during and after progressive 5 min stages of lower body negative pressure (LBNP) in 7 subjects. Changes in stroke volume were calculated from the systolic velocity integrals. A unique 20 MHz PD was used to estimate bloodflow in the posterior tibial artery. With -20 torr mean stroke volume fell 11% and then continued to decline by 48% before LBNP was terminated. Mean tibial flow fell progressively with LBNP stress, due to an increase in reverse flow component and a reduction in peak forward flow and diameter. Stroke volume increased and heart rate fell dramatically during the first 15 sec of recovery. The LBNP was terminated early in 2 subjects because of vasovagal symptons (V). During V the stroke volume rose 86% which more than compensated for the drop in heart rate. This implies that V is accompanied by a paradoxical increase in venous return and that the reduction in HR is the primary cardiovascular event. During the first 15 sec of recovery these 2 subjects had a distinctive marked rise to heart rate reminiscent of the Bainbridge reflex.

Source record↗

Inflight evaluation of four measures of pilot workload

Four measures of pilot workload were tested in the NASA C-141 Kuiper Airborne Observatory. The measured included a communications analysis, subjective ratings of workload, subjective ratings of additional factors related to workload, and heart rate. Data were collected for 11 flights, each of which lasted approximately seven hours. Heart rate was found to be significantly higher for the pilot who was flying than for the pilot who was not flying and it varied significantly across flight segments, peaking during landing and take off, particularly for the pilot in the left seat who was resonsible for aircraft control. For both left and right seats, the subjective assessment of stress rather than the subjective assessment of workload was significantly correlated with variation in heart rate. Frequencies of different types of communications varied significantly across segments of flight, however, they were not correlated with subjective ratings of workload. There was a significant difference between the left and right seats in the types of activities that contributed to their workload, however, workload was considered to be equivalent for the two.

Hart, S. G.↗

Neurohumoral and mechanical factors in the modulation of left ventricular mass

The goals for the research were to define, describe, and study those neuroendocrine and mechanical mechanisms that may play a role in the initiation and maintenance of an increase in, or cause regression of, the mass of the left ventricle. Dynamic changes in heart mass have been observed to occur in man and animals: (1) enlargement of the heart is frequently encountered in patients with hypertensive disease, and (2) decrease in heart mass has been reported for men exposed to prolonged space flight. The basic physiologic processes which may explain how these changes occur, and the effects of gain or loss of myocardial mass on cardiac performance were considered significant questions to be answered for the benefit of the National Aeronautics and Space Administration.

Franklin, Eleanor I.↗

Effect of water immersion on cardiopulmonary physiology at high gravity (+Gz)

The cardiopulmonary responses of eight male subject between 21-31 years exposed to 1, 2, and 3 Gz during immersion at 35 + or - 0.5 C to heart level and during control dry rides are studied. Ventilation, O2 consumption, the end-tidal pressure of CO2, heart frequency, cardiac output, functional residual capacity, and the arterial pressure of CO2 were measured. It is observed that as Gz increases ventilation, heart frequency, and O2 consumption increase, and the end-tidal and arterial pressures of CO2 decrease during dry rides, but are not altered during immersion. It is detected that the functional residual capacity is lower during immersion and decreases in both the dry and immersed state as Gz increases, and cardiac output decreases as Gz increases in dry rides. It is noted that changes produced by acceleration in a Gz direction are due to the effect on the systemic circulation rather than to the effect on the lungs.

Arieli, R.↗

Atropine unmasks bed-rest effect - A spectral analysis of cardiac interbeat intervals

Heart rate spectral data obtained for 10 male subjects between 35-49 years following orthostatic tolerance testing with lower body negative pressure prebed rest and after 7-10 days of bed rest, while on placebo and after intravenous atropine are analyzed. Comparison of the spectral atropine rms for subjects prebed rest and after bed rest reveal a decrease from 63 + or - 24 ms to 40 + or - 23 ms. It is observed that heart rate interval variability for subjects after bed rest and with atropine is reduced; the heart rate at bed rest with atropine is increased from 70.4 + or - 12.4 beats/min prebed rest to 83.7 + or - 18.9 beats/min; and the exercise tolerance time for subjects in the atropine prebed-rest phase (658 + or - 352 s) is higher than the bed-rest phase (505 + or - 252 s). It is noted that bed rest impairs the cardiovascular capacity to adaptively modulate physiological responses, atropine exposes bed-rest deconditioning effects, and spectral analysis is useful for studying the effects of bed-rest deconditioning on cardiac dynamics.

Goldberger, Ary L.↗

Inflight application of three pilot workload measurement techniques

Three inflight techniques for workload measurement were tested in nine pilots flying the NASA Kuiper Airborne Observatory: subjective ratings, heart rate, and communication performance. The activities that contributed to the crew-member workload varied; the commander was responsible for aircraft control and navigation whereas the copilot handled communications. The three workload measures were found to provide different information. Pilot ratings of workload, effort, and stress were sensitive to variations in flight-related task demands across flight segments but did not reflect specific differences in the type of demands imposed on the commander and the copilot. The heart rate was sensitive to the differential impact of duties, being higher for the commander than for the copilot. The rate of communications per minute of flight proved to be the most sensitive indicator. It was related to workload, stress, effort rating, and average heart rate across flight segments.

Hart, Sandra G.↗

Numerical simulation of flow through biofluid devices

The results of a numerical simulation of flow through an artificial heart and through an artificial tilting-disk heart valve are presented. The simulation involves solving the incompressible Navier-Stokes equations; the solution process is described. The details and difficulties of modeling these particular geometries are discussed. The artificial heart geometry uses a single moving grid, and the valve computation uses an overlaid-grid approach with one moving grid and one stationary grid. The equations must be solved iteratively for each discrete time step of the computations, requiring a significant amount of computing time. It is particularly difficult to analyze and present the fluid physics represented by these calculations because of the time-varying nature of the flow, and because the flows are internal. Three-dimensional graphics and scientific visualization techniques have become instrumental in solving these problems.

Rogers, Stuart E.↗