Search NASA⌕ Search

SEARCH · Search NASA

Results for “HPC Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

459 records · Page 26

US Department of Energy, Office of Science High Performance Computing Facility Operational Assessment 2021: Oak Ridge Leadership Computing Facility

Oak Ridge National Laboratory’s (ORNL’s) Leadership Computing Facility (OLCF) continues to surpass its operational target goals of supporting users; delivering fast, reliable computational ecosystems; creating innovative solutions for high-performance computing (HPC) needs; contributing to the community to build the next generation HPC workforce, and managing risks, safety, and security associated with operating some of the most powerful computers in the world. The results can be seen in the cutting-edge science conducted by users and the praise from the research community. Calendar year (CY) 2021 saw continued excellence in research supported by the OLCF’s leadership-class computing resources, including Summit (the nation’s most powerful supercomputer), the global scratch file system Alpine, the Scalable Protected Infrastructure (SPI), the Exploratory Visualization Environment for Research in Science and Technology (EVEREST), and the archival mass-storage resource High-Performance Storage System (HPSS). While maintaining access and exceptional user support for Summit, the OLCF continued to make progress on the installation and deployment of Frontier, which will be the nation’s first exascale system when it comes online at the start of CY 2023. Users have already begun running and optimizing scientific codes on Crusher, the OLCF test and development system equipped with Frontier’s architecture. Throughout the year, the OLCF maintained a strong culture of operational excellence, including risk management, workplace safety, and cybersecurity. The OLCF’s rigorous risk management strategy anticipated and mitigated risks, and at this time there are no high-priority operational risks. Similarly, ORNL and the OLCF were committed to operating under the US Department of Energy’s (DOE’s) safety regulations that ensure a safe workplace. Technical staff tracked and monitored existing threats and vulnerabilities within the OLCF while continually developing tools and practices to enhance operations without increasing the facility’s risk. CY 2021 was filled with outstanding results and accomplishments, including a very high rating from users on overall satisfaction for the eighth consecutive year; a tremendous number of node hours delivered to 1,671 researchers on Summit; and the successful delivery of the allocation split of roughly 60%, 20%, and 20% of core-hours offered for the Innovative and Novel Computational Impact on Theory and Experiment (INCITE), Advanced Scientific Computing Research Leadership Computing Challenge (ALCC), and Director’s Discretionary (DD) programs, respectively (Section 2). COVID-19 research remained a focus in 2021, and the ALCC and DD programs allocated over 1 million Summit hours to the COVID-19 High Performance Computing Consortium. These accomplishments, coupled with the high utilization rates (i.e., overall and capability usage), represent the fulfillment of the promise of leadership class machines: efficient facilitation of leadership-class computational applications.

97 MATHEMATICS AND COMPUTING↗

Massively parallel phase-field simulations targeting exascale

The interface thickness in the phase-field (PF) method limits its simulation scales. Consequently, large-scale PF simulations become prohibitively expensive for resolving the extremely fine microstructures that typically form during rapid solidification processing. This challenge is significant in predicting microstructure evolution in metal additive manufacturing and has been identified by the United States Department of Energy’s Exascale Computing Project. Here, to address this, we develop a multi-GPU and MPI-based massively parallel simulation code, utilizing state-of-the-art algorithms, software, and libraries, for large-scale three-dimensional (3D) PF simulations. We report the first GPU-parallel PF simulations on Frontier (currently the second TOP500 exascale cluster) and Summit machines, taking dendritic growth as an example problem. We evaluate the parallel performance of our implementation using scaling studies with more than 24 000 GPUs (among the largest known computations to date) and the acceleration performance using large-scale simulations of dendritic growth in 3D. Finally, massively parallel GPUs in these supercomputers enabled the first coupled multiscale simulations of laser melting and subsequent dendritic solidification on the scale of a full melt-pool, demonstrating the feasibility of performing PF simulations with a point total over 2 billion grid points within an acceptable time.

Exascale↗

MOSIQS: Persistent Memory Object Storage With Metadata Indexing and Querying for Scientific Computing

Scientific applications often require high-bandwidth shared storage to perform joint simulations and collaborative data analytics. Shared memory pools provide a chance to satisfy such needs. Recently, a high-speed network such as Gen-Z utilizing persistent memory (PM) offers an opportunity to create a shared memory pool connected to compute nodes. However, there are several challenges to use scientific applications on the shared memory pool directly such as scalability, failure-atomicity, and lack of scientific metadata-based search and query. In this paper, we propose MOSIQS, a persistent memory object storage framework with metadata indexing and querying for scientific computing. We design MOSIQS based on the key idea that memory objects on PM pool can live beyond the application lifetime and can become the sharing currency for applications and scientists. MOSIQS provides an aggregate memory pool atop an array of persistent memory devices to store and access memory objects to accelerate scientific computing. MOSIQS uses a lightweight persistent memory key-value store to manage the metadata of memory objects, which enables memory object sharing. To facilitate metadata search and query over millions of memory objects resident on memory pool, we introduce Group Split and Merge (GSM), a novel persistent index data structure designed primarily for scientific datasets. GSM splits and merges dynamically to minimize the query search space and maintains low query processing time while overcoming the index storage overhead. MOSIQS is implemented on top of PMDK. We evaluate the proposed approach on many-core server with an array of real PM devices. Experimental results show that MOSIQS gains a 100% write performance improvement and executes multi-attribute queries efficiently with 2.7× less index storage overhead offering significant potential to speed up scientific computing applications.

97 MATHEMATICS AND COMPUTING↗

Height Above Nearest Drainage (HAND) and Hydraulic Property Table for CONUS

The continental flood inundation mapping (CFIM) framework is a high-performance computing (HPC)-based computational framework for the Height Above Nearest Drainage (HAND)-based inundation mapping methodology. Using the 10m Digital Elevation Model (DEM) data produced by U.S. Geological Survey (USGS) 3DEP (the 3-D Elevation Program) and the NHDPlus hydrography dataset produced by USGS and the U.S. Environmental Protection Agency (EPA), a hydrological terrain raster called HAND is computed for HUC6 units in the conterminous U.S. (CONUS). The value of each raster cell in HAND is an approximation of the relative elevation between the cell and its nearest water stream. Derived from HAND, a hydraulic property table is established to calculate river geometry properties for each of the 2.7 million river reaches covered by NHDPlus (5.5 million kilometers in total length). This table is a lookup table for water depth given an input stream flow value. Such lookup is available between water depth 0m and 25m at 1-foot interval. The flood inundation map is then computed by using HAND and this lookup table based on the near real-time water forecast from the National Water Model (NWM) at the National Oceanic and Atmospheric Administration (NOAA). HAND and the Hydraulic Property Table version 0.2. is created to correspond to data updates in the USGS 1/3 arcsec DEM, the USGS National Hydrography Dataset, including its Water Boundary Dataset, and the NHDPlus medium resolution dataset. This dataset comprises 331 HUC6 units for CONUS (excluding the five great lakes units), each is a downloadable zip file. Version 0.1 was computed at the National Center for Supercomputing Applications (NCSA) at the University of Illinois at Urban-Champaign in 2016 and is currently hosted at the Texas Advanced Computing Center (TACC). Please cite this data DOI and the following publications and data DOIs when you use HAND and the hydraulic property table: Liu, Yan Y., David R. Maidment, David G. Tarboton, Xing Zheng, and Shaowen Wang. 'A CyberGIS integration and computation framework for high-resolution continental-scale flood inundation mapping.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 770-784. DOI: 10.1111/1752-1688.12660 Zheng, Xing, David G. Tarboton, David R. Maidment, Yan Y. Liu, and Paola Passalacqua. 'River channel geometry and rating curve estimation using height above the nearest drainage.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 785-806. DOI: 10.1111/1752-1688.12661 Liu, Y. (2018). Height Above Nearest Drainage (HAND) for CONUS - v0.1, HydroShare, https://doi.org/10.4211/hs.69f7d237675c4c73938481904358c789 LICENSE FOR USE -- MAPS AND DATA DISCLAIMER This resource is shared under the Creative Commons Attribution CC BY, http://creativecommons.org/licenses/by/4.0/ MAPS AND DATA DISCLAIMER The Oak Ridge National Laboratory (ORNL) shall not be held liable for improper or incorrect use of the data described or information contained on this map or associated series of maps. The data and related map graphics are not legal, land survey or engineering documents and are not intended to be used as such. ORNL gives no warranty, express or implied, as to the accuracy, reliability, utility or completeness of this information. The user of these maps and data assumes all responsibility and risk for the use of the maps and data. ORNL disclaims all warranties, representations or endorsements either express or implied, with regard to the information contained in this map product, including, but not limited to, all implied warranties of merchantability, fitness for a particular purpose or non-infringement. This preliminary map product is for research and review purposes only. It is not intended to be used for emergency management operational or life safety decisions at the local or regional governmental level or by the general public. Users requiring information regarding hazardous conditions or meteorological conditions for specific geographic areas should consult directly with their city or county emergency management office.

54 ENVIRONMENTAL SCIENCES↗

Height Above Nearest Drainage (HAND) and Hydraulic Property Table for CONUS - Version 0.21 (20200601)

The continental flood inundation mapping (CFIM) framework is a high-performance computing (HPC)-based computational framework for the Height Above Nearest Drainage (HAND)-based inundation mapping methodology. Using the 10m Digital Elevation Model (DEM) data produced by U.S. Geological Survey (USGS) 3DEP (the 3-D Elevation Program) and the NHDPlus hydrography dataset produced by USGS and the U.S. Environmental Protection Agency (EPA), a hydrological terrain raster called HAND is computed for HUC6 units in the conterminous U.S. (CONUS). The value of each raster cell in HAND is an approximation of the relative elevation between the cell and its nearest water stream. Derived from HAND, a hydraulic property table is established to calculate river geometry properties for each of the 2.7 million river reaches covered by NHDPlus (5.5 million kilometers in total length). This table is a lookup table for water depth given an input stream flow value. Such lookup is available between water depth 0m and 25m at 1-foot interval. The flood inundation map is then computed by using HAND and this lookup table based on the near real-time water forecast from the National Water Model (NWM) at the National Oceanic and Atmospheric Administration (NOAA). HAND and the Hydraulic Property Table version v0.21 is an upgrade to v0.2. Version 0.21 applies NHD HR etching to DEMs for all HUC6 units before running the HAND workflow. This new version also fixed the issue of void areas along HUC boundary. This dataset comprises 331 HUC6 units for CONUS (excluding the five great lakes units), each is a downloadable zip file. Version 0.1 was computed at the National Center for Supercomputing Applications (NCSA) at the University of Illinois at Urban-Champaign in 2016 and is currently hosted at the Texas Advanced Computing Center (TACC). Please cite this data DOI and the following publications and data DOIs when you use HAND and the hydraulic property table: Liu, Yan Y. Height Above Nearest Drainage (HAND) and Hydraulic Property Table for CONUS - Version 0.2. (20200301). Oak Ridge Leadership Computing Facility. (2020). DOI: 10.13139/ORNLNCCS/1608331 Liu, Yan Y., David R. Maidment, David G. Tarboton, Xing Zheng, and Shaowen Wang. 'A CyberGIS integration and computation framework for high-resolution continental-scale flood inundation mapping.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 770-784. DOI: 10.1111/1752-1688.12660 Zheng, Xing, David G. Tarboton, David R. Maidment, Yan Y. Liu, and Paola Passalacqua. 'River channel geometry and rating curve estimation using height above the nearest drainage.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 785-806. DOI: 10.1111/1752-1688.12661 Liu, Y. (2018). Height Above Nearest Drainage (HAND) for CONUS, HydroShare, https://doi.org/10.4211/hs.69f7d237675c4c73938481904358c789 LICENSE FOR USE -- MAPS AND DATA DISCLAIMER This resource is shared under the Creative Commons Attribution CC BY, http://creativecommons.org/licenses/by/4.0/ MAPS AND DATA DISCLAIMER The Oak Ridge National Laboratory (ORNL) shall not be held liable for improper or incorrect use of the data described or information contained on this map or associated series of maps. The data and related map graphics are not legal, land survey or engineering documents and are not intended to be used as such. ORNL gives no warranty, express or implied, as to the accuracy, reliability, utility or completeness of this information. The user of these maps and data assumes all responsibility and risk for the use of the maps and data. ORNL disclaims all warranties, representations or endorsements either express or implied, with regard to the information contained in this map product, including, but not limited to, all implied warranties of merchantability, fitness for a particular purpose or non-infringement. This preliminary map product is for research and review purposes only. It is not intended to be used for emergency management operational or life safety decisions at the local or regional governmental level or by the general public. Users requiring information regarding hazardous conditions or meteorological conditions for specific geographic areas should consult directly with their city or county emergency management office.

54 ENVIRONMENTAL SCIENCES↗

Machine learning-driven predictive resource management in complex science workflows

Here, the collaborative efforts of large communities in science experiments, often comprising thousands of global members, reflect a monumental commitment to exploration and discovery. Recently, advanced and complex data processing has gained increasing importance in science experiments. Data processing workflows typically consist of multiple intricate steps, and the precise specification of resource requirements is crucial for each step to allocate optimal resources for effective processing. Estimating resource requirements in advance is challenging due to a wide range of analysis scenarios, varying skill levels among community members, and the continuously increasing spectrum of computing options. One practical approach to mitigate these challenges involves initially processing a subset of each step to measure precise resource utilization from actual processing profiles before completing the entire step. While this two-staged approach enables processing on optimal resources for most of the workflow, it has drawbacks such as initial inaccuracies leading to potential failures and suboptimal resource usage, along with overhead from waiting for initial processing completion, which is critical for fast-turnaround analyses. In this context, our study introduces a novel pipeline of machine learning models within a comprehensive workflow management system, the Production and Distributed Analysis (PanDA) system. These models employ advanced machine learning techniques to predict key resource requirements, overcoming challenges posed by limited upfront knowledge of characteristics at each step. Accurate forecasts of resource requirements enable informed and proactive decision-making in workflow management, enhancing the efficiency of handling diverse, complex workflows across heterogeneous resources.

97 MATHEMATICS AND COMPUTING↗

Model America - data and models of every U.S. building

The 5-year goal of the 'Model America' concept was to generate a model of every building in the United States. This data repository delivers on that goal. Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM). There were 125,714,640 buildings detected in the United States and this dataset contains 122,930,327 (97.8%) buildings which resulted in a successful simulation. Future, annual updates have been proposed that may include additional buildings, data improvements, or other algorithmic enhancements. This dataset of 122.9 million buildings includes: Models (state_county.zip) - OpenStudio (v3.1.0) and EnergyPlus (v9.4) building energy models. Please note that the download requires the free Globus Connect Personal (https://www.globus.org/globus-connect-personal); Each model has approximately 3,000 building input descriptors that can be extracted. Please see the EnergyPlus(v9.4) 2,784-page Input/Output Reference Guide (https://energyplus.net/sites/all/modules/custom/nrel_custom/pdfs/pdfs_v9.4.0/InputOutputReference.pdf) for everything that can be retrieved or simulated from these models. These models were derived from the following metadata, which is not included in this dataset: 1. ID - unique building ID 2. County - county name 3. State - state name 4. CZ - ASHRAE Climate Zone designation 5. Clim_Zone - text label of climate zone 6. est_year - estimated year of construction 7. est_commercial - estimated building type (0=residential, 1=commercial) 8. Centroid - building center location in latitude/longitude (from Footprint2D) 9. Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) 10. Height - building height (meters) 11. Area2D - footprint area (ft2) 12. BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards 13. WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) 14. NumFloors - number of floors (above-grade) 15. Area - estimate of total conditioned floor area (ft2) 16. Standard - building vintage. These models are made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD), U.S. Dept. of Energy's (DOE) Building Technologies Office (BTO), Office of Electricity (OE), Biological and Environmental Research (BER), and National Nuclear Security Administration (NNSA). This research used resources of the Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility supported under Contract DE-AC02-06CH11357. Please cite as: New, Joshua R., Adams, Mark, Bass, Brett, Berres, Anne, and Clinton, Nicholas (2021). 'Model America - data and models of every U.S. building. [Data set].' Constellation, doi.ccs.ornl.gov/ui/doi/339, April 14, 2021

24 POWER TRANSMISSION AND DISTRIBUTION↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SBIR PHASE I FINAL REPORT: Adoption of High Performance Computational (HPC) Modeling Software for Widespread Use in the Manufacture of Welded Structures

Many US manufacturing companies have moved fabrication and production facilities off shore because of cheaper labor costs. A key aspect in bringing these jobs back to the US is the use of technology to render US-made fabrications more efficient overall with higher quality. A new initiative of the current administration has the goal of enhancing competitiveness to retain manufacturing jobs in the US. One significant competitive advantage that has emerged in the US over the last two decades is the use of virtual design for fabrication of large structures in the light and heavy materials industries. Industries that have used virtual design and analysis tools have reduced material parts size, developed environmentally-friendly fabrication processes, improved product quality and performance, and reduced manufacturing costs. Indeed, Caterpillar Inc. (CAT), one of the partners in this effort, continues to have a large fabrication presence in the US because of the use of weld fabrication modeling to optimize fabrications by controlling weld residual stresses and distortions and improving fatigue, corrosion, and fracture performance. This report describes Engineering Mechanics Corporation of Columbus (Emc2's) DOE SBIR Phase I results which extended an existing, state-of-the-art software code, VFT, currently used to design and model large welded structures prior to fabrication - to a broader range of products with widespread applications for small and medium-sized enterprises (SMEs). VFT helps control distortion, can minimize and/or control residual stresses, control welding microstructure, and pre-determine welding parameters such as weld-sequencing, pre-bending, thermal-tensioning, etc. VFT uses material properties, consumable properties, etc. as inputs. Through VFT, manufacturing companies can avoid costly design changes after fabrication. This leads to the concept of joint design/fabrication where these important disciplines are intimately linked to minimize fabrication costs. VFT currently is tied to a commercial solver which makes it prohibitively expensive for use by SMEs, as there is a significant licensing cost for the solver - over and above for the relatively minimal cost for VFT. Emc2 developed this software code over a number of years in close cooperation with CAT (Peoria, IL), who currently uses this code exclusively for worldwide fabrication, product design and development activities. The use of VFT has allowed CAT to move directly from design to product fabrication and helped eliminate (to a large extent) new product prototyping and subsequent testing. Additionally, CAT has been able to eliminate/reduce costly one-of-a-kind appliances used to reduce distortion effects due to fabrication. In this context, SMEs can realize the same kind of improved product quality and reduced cost through adoption of the adapted version of VFT for design and subsequent manufacture of new products. Emc2's DOE SBIR Phase I effort successfully adapted VFT so that SMEs have access to this sophisticated and proven methodology that is quick, accurate and cost effective and available on-demand to address weld-simulation and fabrication problems prior to manufacture. The open source code, WARP3D, a high performance finite element code mainly used in fracture and damage assessment of structures, was modified so that computational weld problems can be solved efficiently on multiple processors and threads with VFT. The thermal solver for VFT, based on a series of closed form solution approximations, was enhanced for solution on multiple processors greatly increasing overall speed. In addition, the graphical user interface (GUI) has been tailored to integrate these solutions with WARP3D. The GUI is used to define all the weld pass descriptions, number of passes, material properties, consumable properties, weld speed, etc. for the structure to be modeled. The GUI was improved to make it user-friendly for engineers that are not experts in finite element modeling. Finally, a plan for porting VFT onto the Ohio Supercomputer Center (OSC) through its hosted Manufacturing and Polymer Portal has been developed. This access route will permit SMEs to perform weld modeling to improve their competitiveness at a reasonable cost. All of these improvements are detailed in this repo

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗