Rocking curve imaging of high quality sapphire crystals in backscattering geometry

Here, we report on the characterization of high quality sapphire single crystals suitable for high-resolution X-ray optics at high energy. Investigations using rocking curve imaging reveal the crystals to be of uniformly good quality at the level of ~10 -4 in lattice parameter variations, deltad/d. But, investigations using backscattering rocking curve imaging with lattice spacing resolution of deltad/d ~ 5.10 -8 shows very diverse quality maps for all crystals. Our results highlight nearly ideal areas with edge length of 0.2-0.5 mm in most crystals, but a comparison of the back re ection peak positions shows that even neighboring ideal areas exhibit a relative difference in the lattice parameters on the order of deltad/d = 10-20.10 -8 ; this is several times larger than the rocking curve width. Furthermore, the stress-strain analysis suggests that an extremely stringent limit on the strain at a level of ~100 kPa in the growth process is required in order to produce crystals with large areas of the quality required for X-ray optics at high energy.

36 MATERIALS SCIENCE↗

LENS MODELS OF HERSCHEL-SELECTED GALAXIES FROM HIGH-RESOLUTION NEAR-IR OBSERVATIONS

We present Keck-Adaptive Optics and Hubble Space Telescope high resolution near-infrared (IR) imaging for 500 μm bright candidate lensing systems identified by the Herschel Multi-tiered Extragalactic Survey and Herschel Astrophysical Terahertz Large Area Survey. Out of 87 candidates with near-IR imaging, 15 (∼17%) display clear near-IR lensing morphologies. We present near-IR lens models to reconstruct and recover basic rest-frame optical morphological properties of the background galaxies from 12 new systems. Sources with the largest near-IR magnification factors also tend to be the most compact, consistent with the size bias predicted from simulations and previous lensing models for submillimeter galaxies (SMGs). For four new sources that also have high-resolution submillimeter maps, we test for differential lensing between the stellar and dust components and find that the 880 μm magnification factor (μ{sub 880}) is ∼1.5 times higher than the near-IR magnification factor (μ{sub NIR}), on average. We also find that the stellar emission is ∼2 times more extended in size than dust. The rest-frame optical properties of our sample of Herschel-selected lensed SMGs are consistent with those of unlensed SMGs, which suggests that the two populations are similar.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging of quantum Hall edge states under quasiresonant excitation by a near-field scanning optical microscope

A high resolution mapping of quantum Hall edge states has been performed by locally creating electrons with small excess energies with a near-field scanning optical microscope in a dilution refrigerator. We have observed fine structures parallel to the edge in photovoltage signals, which appear only at low temperature. The observed fine structures near sample edges have been seen to shift inward with increase in magnetic field in accordance with Chklovskii Shklovskii, and Glazman model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase-Length Optical Phase-Locked-Loop Sensor (PLOPS)

PLOPS system designed to provide high-resolution measurement of change in optical length from optical-system source to any optical reflector, including diffuse reflector. Serves as adjustable optical ruler, providing high resolution in measurements of small and large changes in distance to target. Use is broad and includes most measurement situations requiring information on length, vibration, and their derivatives. Applications include building dynamics, remote sensing of vibrations in such systems as turbine-based machinery, monitoring of structural dynamics, noncontacting sensing of surface contours, measurement of large strains as in earthquake monitoring, measurement of atmospheric dynamics and turbulence, high-resolution sensing of humidity, detection of surface acoustic waves by optical microscopy, and related areas.

Heyman, Joseph S.↗

Emission-Line Pre-Main Sequence Stars and X-Ray Sources in Orion

we use low-resolution, broadband optical spectroscopy and high-resolution X-ray imaging to continue the study of X-ray sources in a portion of the Orion star-formation region about 1 degree south of the Trapezium.

stars: emission lines--stars: pre-main sequence-- ↗

High energy-resolution studies of electron impact optical excitation functions. I - The second positive system of N2.

The relative emission cross section for the N2 second positive system (0,0) and (1,0) bands excited by electron impact was measured for incident electron energies from threshold to 17 eV. The use of a high energy-resolution electron spectrometer coupled to an optical detection system made it possible to obtain the measurements with an incident electron beam having an energy half width of 50 meV. Calibration of the incident electron energy was provided by observing the scattering resonances in nitrogen and helium. The maximum of the (0,0) and (1,0) bands were found to be at approximately 14.02 and 14.3 eV, respectively. A small structural feature that was pressure-independent appeared only in the (0,0) band emission cross section. Another such feature was pressure-dependent and appeared more strongly in the (1,0) band cross section.

Finn, T. G.↗

The eleventh and twelfth data release of the Sloan Digital Sky Survey: Final data from SDSS-III

The third generation of the Sloan Digital Sky Survey (SDSS-III) took data from 2008 to 2014 using the original SDSS wide-field imager, the original and an upgraded multi-object fiber-fed optical spectrograph, a new near-infrared high-resolution spectrograph, and a novel optical interferometer. All of the data from SDSS-III are now made public. In particular, this paper describes Data Release 11 (DR11) including all data acquired through 2013 July, and Data Release 12 (DR12) adding data acquired through 2014 July (including all data included in previous data releases), marking the end of SDSS-III observing. Relative to our previous public release (DR10), DR12 adds one million new spectra of galaxies and quasars from the Baryon Oscillation Spectroscopic Survey (BOSS) over an additional 3000 deg 2 of sky, more than triples the number of H-band spectra of stars as part of the Apache Point Observatory (APO) Galactic Evolution Experiment (APOGEE), and includes repeated accurate radial velocity measurements of 5500 stars from the Multi-object APO Radial Velocity Exoplanet Large-area Survey (MARVELS). The APOGEE outputs now include the measured abundances of 15 different elements for each star. In total, SDSS-III added 5200 deg 2 of ugriz imaging; 155,520 spectra of 138,099 stars as part of the Sloan Exploration of Galactic Understanding and Evolution 2 (SEGUE-2) survey; 2,497,484 BOSS spectra of 1,372,737 galaxies, 294,512 quasars, and 247,216 stars over 9376 deg 2 ; 618,080 APOGEE spectra of 156,593 stars; and 197,040 MARVELS spectra of 5513 stars. Since its first light in 1998, SDSS has imaged over 1/3 of the Celestial sphere in five bands and obtained over five million astronomical spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration and Testing of Small High-Resolution Transition Edge Sensor Microcalorimeters With Optical Photons

Pulses of narrow line-width optical photons can be used to calibrate and test sub-2 eV full-width at half-maximum (FWHM) energy resolution transition-edge sensor (TES) microcalorimeters at low energies (<1 keV),where it is very challenging to obtain X-ray calibration lines comparable to (or narrower than) the detector resolution. This scheme depends on the ability to resolve the number of 3 eV photons in each pulse, which we have recently demonstrated up to photon numbers of about 300. AtLTD-18 we showed preliminary results obtained with this technique on a 0.25 eV baseline resolution TES microcalorimeter designed for the ultra-high-resolution sub-array of the Lynx mission. The line-shape was well described by a simple Gaussian. However, the difficulty of delivering photons to the small 46 μm square absorbers resulted in a large thermal crosstalk signal, whose random nature is expected to rapidly degrade the observed energy resolution towards higher photon numbers/energies. We have since improved the coupling between the optical fiber and the TES absorber and report here our current results.

Felix T Jaeckel↗

Optical and infrared masers

High resolution studies of atoms and molecules applied to optical and infrared maser experimentation

Source record↗

Investigation of active regions at high resolution by balloon flights of the Solar Optical Universal Polarimeter (SOUP)

SOUP is a versatile, visible-light solar observatory, built for space or balloon flight. It is designed to study magnetic and velocity fields in the solar atmosphere with high spatial resolution and temporal uniformity, which cannot be achieved from the surface of the earth. The SOUP investigation is carried out by the Lockheed Palo Alto Research Laboratory, under contract to NASA's Marshall Space Flight Center. Co-investigators include staff members at a dozen observatories and universities in the U.S. and Europe. The primary objectives of the SOUP experiment are: to measure vector magnetic and velocity fields in the solar atmosphere with much better spatial resolution than can be achieved from the ground; to study the physical processes that store magnetic energy in active regions and the conditions that trigger its release; and to understand how magnetic flux emerges, evolves, combines, and disappears on spatial scales of 400 to 100,000 km. SOUP is designed to study intensity, magnetic, and velocity fields in the photosphere and low chromosphere with 0.5 arcsec resolution, free of atmospheric disturbances. The instrument includes: a 30 cm Cassegrain telescope; an active mirror for image stabilization; broadband film and TV cameras; a birefringent filter, tunable over 5100 to 6600 A with 0.05 A bandpass; a 35 mm film camera and a digital CCD camera behind the filter; and a high-speed digital image processor.

Tarbell, T.↗

Active Dopant Optical Spectroscopy via Laser Ablation for High Resolution Spectral Measurements

The goal of this exploratory express LDRD is to demonstrate a reproducible laser activated doping diagnostic for eventual use on the Z machine by producing consistent spectral line emission with radiances above 10 5 W sr -1 nm -1 111 -2 from a variety of dopant materials. Here we show that while such radiances are achieved, the line emission is from regions with high electron densities, and close to the laser ablation surface. Therefore, it would be more ideal to improve current optical spectroscopy capabilities on Z to view radiances around 10 4 W sr -l nm -l m -2 . We also discuss the viability of a modular beam path that can be remotely aligned and used on the Z machine. This technique can be used to make spatially resolved measurements of electric and magnetic field strengths and electron densities within the Z power flow and load regions. The measurements can also be used to inform theory and simulation efforts needed to design the next generation of pulsed power capabilities. This was funded as an exploratory LDRD project, number: 214278

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of solar active regions at high resolution by balloon flights of the solar optical universal polarimeter, extended definition phase

Technical studies of the feasibility of balloon flights of the former Spacelab instrument, the Solar Optical Universal Polarimeter, with a modern charge-coupled device (CCD) camera, to study the structure and evolution of solar active regions at high resolution, are reviewed. In particular, different CCD cameras were used at ground-based solar observatories with the SOUP filter, to evaluate their performance and collect high resolution images. High resolution movies of the photosphere and chromosphere were successfully obtained using four different CCD cameras. Some of this data was collected in coordinated observations with the Yohkoh satellite during May-July, 1992, and they are being analyzed scientifically along with simultaneous X-ray observations.

Tarbell, Theodore D.↗

Full molecular trajectories of RNA polymerase at single base-pair resolution

Significance Optical tweezers enable scientists to follow the dynamics of molecular motors at high resolution. The ability to discern a motor’s discrete steps reveals important insights on its operation. Some motors operate at the scale of angstroms, rendering the observation of their steps extremely challenging. In some cases, such small steps have been observed sporadically; however, the full molecular trajectories of steps and intervals between steps remain elusive due to instrumental noise. Here, we eliminate the main source of noise of most high-resolution dual-trap optical tweezers and developed both a single-molecule assay and a self-learning algorithm to uncover the full trajectories of such a motor: RNA polymerase. Using this method, a whole new set of experiments becomes possible.

59 BASIC BIOLOGICAL SCIENCES↗

Achieving High-Resolution Hard X-ray Microscopy using Monolithic 2D Multilayer Laue Lenses

This article introduces the 2D multilayer Laue lens (MLL) nanofocusing optics recently developed for high-resolution hard X-ray microscopy. The new optics utilized a micro-electro-mechanical-system (MEMS)-based template to accommodate two linear MLL optics in a pre-aligned configuration. Angular misalignment between the two lenses was controlled in tens of millidegrees, and the lateral position error was on a micrometer scale. Using the developed 2D MLLs, an astigmatism-free point focus of approximately 14 nm by 13 nm in horizontal and vertical directions, respectively, at 13.6 keV photon energy was obtained. In conclusion, the success of 2D MLL optics with an approaching 10 nm resolution is a significant step forward for the development of high-resolution hard X-ray microscopy and applications of MLL optics in the hard X-ray community.

36 MATERIALS SCIENCE↗

Formation of wide-blocky calcite veins by extreme growth competition

Liassic limestones on the coast of Somerset in the UK contain dense arrays of calcite microveins with a common, but poorly understood microstructure, characterized by laterally wide crystals that form bridges across the vein. We investigated the mechanisms of formation and evolution of these ‘wide-blocky’ vein microstructures using a combination of high-resolution analytical methods, including virtual petrography, optical cathodoluminescence and scanning electron microscopy techniques (e.g. energy-dispersive X-ray spectrometry, back-scattered electron imaging, cathodoluminescence and electron back-scattered diffraction), laboratory experiments and multiphase field modelling. Our results indicate that the studied veins formed in open, fluid-filled fractures, each in a single opening and sealing episode. As shown by the optical and electron back-scattered diffraction images, the vein crystals grew epitaxially on grains of the wall rock and we hypothesize that their growth rates differed depending on whether the crystals were on a wall rock grain substrate that fractured intergranularly (slow growth rates) or transgranularly (rapid growth rates). Our multiphase field models support this hypothesis, showing that wide, blocky crystals only form where there are significant differences in the growth rate and are dependent on the type of seed grain. These results provide strong evidence for extreme growth competition, a process that we propose controls vein-filling in many micritic carbonate reservoirs, as well as demonstrate that the characteristics of the fracture wall can affect the filling processes in syntaxial veins. Supplementary material: The description and images of the studied thin sections are available at https://doi.org/10.6084/m9.figshare.c.5172371 . High-resolution optical microscopy mosaics (under plane-polarized- and crossed polarized light) of the thin section collection in PetroScan file format are available on request from the authors.

Geology↗

CONTROL TESTING OF THE UK NATIONAL NUCLEAR LABORATORY'S RADBALL TECHNOLOGY AT SAVANNAH RIVER NATIONAL LABORATORY

The UK National Nuclear Laboratory (NNL) has developed a remote, non-electrical, radiation-mapping device known as RadBall (patent pending), which offers a means to locate and quantify radiation hazards and sources within contaminated areas of the nuclear industry. To date, the RadBall has been deployed in a number of technology trials in nuclear waste reprocessing plants at Sellafield in the UK. The trials have demonstrated the successful ability of the RadBall technology to be deployed and retrieved from active areas. The positive results from these initial deployment trials and the anticipated future potential of RadBall have led to the NNL partnering with the Savannah River National Laboratory (SRNL) to further underpin and strengthen the technical performance of the technology. RadBall consists of a colander-like outer shell that houses a radiation-sensitive polymer sphere. It has no power requirements and can be positioned in tight or hard-to reach places. The outer shell works to collimate radiation sources and those areas of the polymer sphere that are exposed react, becoming increasingly less transparent, in proportion to the absorbed dose. The polymer sphere is imaged in an optical-CT scanner which produces a high resolution 3D map of optical attenuation coefficients. Subsequent analysis of the optical attenuation maps provides information on the spatial distribution and strength of the sources in a given area forming a 3D characterization of the area of interest. This study completed at SRNL addresses key aspects of the testing of the RadBall technology. The first set of tests was performed at Savannah River Nuclear Solutions Health Physics Instrument Calibration Laboratory (HPICL) using various gamma-ray sources and an x-ray machine with known radiological characteristics. The objective of these preliminary tests was to identify the optimal dose and collimator thickness. The second set of tests involved a highly contaminated hot cell. The objective of this part of the testing was to characterize a hot cell with unknown radiation sources. The RadBall calibration experiments and hot cell deployment completed at SRNL were successful in that for each trial, the technology was able to locate the radiation sources. The NNL believe that the ability of RadBall to be remotely deployed with no electrical supplies into difficult to access areas of plant and locate and quantify radiation hazards is a unique radiation mapping service. The NNL consider there to be significant business potential associated with this innovative technology.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation

This study introduces a charge coupled device (CCD) area detector based optical-computed tomography (optical-CT) scanner for comprehensive verification of radiation dose distributions recorded in nonscattering radiochromic dosimeters. Defining characteristics include: (i) a very fast scanning time of {approx}5 min to acquire a complete three-dimensional (3D) dataset, (ii) improved image formation through the use of custom telecentric optics, which ensures accurate projection images and minimizes artifacts from scattered and stray-light sources, and (iii) high resolution (potentially 50 {mu}m) isotropic 3D dose readout. The performance of the CCD scanner for 3D dose readout was evaluated by comparison with independent 3D readout from the single laser beam OCTOPUS-scanner for the same PRESAGE dosimeters. The OCTOPUS scanner was considered the 'gold standard' technique in light of prior studies demonstrating its accuracy. Additional comparisons were made against calculated dose distributions from the ECLIPSE treatment-planning system. Dose readout for the following treatments were investigated: (i) a single rectangular beam irradiation to investigate small field and very steep dose gradient dosimetry away from edge effects, (ii) a 2-field open beam parallel-opposed irradiation to investigate dosimetry along steep dose gradients, and (iii) a 7-field intensity modulated radiation therapy (IMRT) irradiation to investigate dosimetry for complex treatment delivery involving modulation of fluence and for dosimetry along moderate dose gradients. Dose profiles, dose-difference plots, and gamma maps were employed to evaluate quantitative estimates of agreement between independently measured and calculated dose distributions. Results indicated that dose readout from the CCD scanner was in agreement with independent gold-standard readout from the OCTOPUS-scanner as well as the calculated ECLIPSE dose distribution for all treatments, except in regions within a few millimeters of the edge of the dosimeter, where edge artifact is predominant. Agreement of line profiles was observed, even along steep dose gradients. Dose difference plots indicated that the CCD scanner dose readout differed from the OCTOPUSscanner readout and ECLIPSE calculations by {approx}10% along steep dose gradients and by {approx}5% along moderate dose gradients. Gamma maps (3% dose-difference and 3 mm distance-to-agreement acceptance criteria) revealed agreement, except for regions within 5 mm of the edge of the dosimeter where the edge artifact occurs. In summary, the data demonstrate feasibility of using the fast, high-resolution CCD scanner for comprehensive 3D dosimetry in all applications, except where dose readout is required close to the edges of the dosimeter. Further work is ongoing to reduce this artifact.

61 RADIATION PROTECTION AND DOSIMETRY↗