Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGING TECHNIQUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Aerothermodynamic Measurements in Hypersonic Non-Equilibrium Flows

High enthalpy arc-jets are unique facilities particularly suited for simulating complex flows in the aerospace field, such as the aerothermodynamics of a re-entry vehicle. Arc-jets are often used to evaluate important design factors such as heat shield materials and vehicle design. Characterization of these facilities is important, as studies often match specific in-flight environments during experiments. Due to the complex environment produced by an arc-jet, with effects such as thermodynamic and chemical non-equilibrium occurring in the flow, characterization experiments are significantly more difficult than in traditional blow-down wind tunnels. The current work aims to characterize an arc-jet facility in terms of flow temperature, velocity and unsteadiness, in a spatially-resolved analysis. To achieve this goal, a non-intrusive imaging technique called “planar laser-induced fluorescence” was performed in the NASA Langley Hypersonic Materials Environ-mental Test System arc-jet facility. The experimental data was analyzed to produce the quantitative measurements in multiple regions of the flow around a blunt body sample. A quasi-1D low fidelity solver was created to numerically simulate the flow to investigate non-equilibrium effects occur-ring outside the imaging region in the arc-jet nozzle. Unsteadiness in the test section was minimized by analyzing a subset of data assessing the gas injection location. Radial velocity, rotational temperature and translational temperature measurements are provided that can be used to validate future high-fidelity computational studies. The temperature measurements revealed rotational non-equilibrium potentially occurring in the flow. This work provides a methodology for characterizing arc-jet facilities, identifying and correcting sources of systematic error, and estimating the uncertainty associated with the quantitative measurements.

laser induced fluorescence↗

Switchable resolution in soft x-ray tomography of single cells

The diversity of living cells, in both size and internal complexity, calls for imaging methods with adaptable spatial resolution. Soft x-ray tomography (SXT) is a three-dimensional imaging technique ideally suited to visualizing and quantifying the internal organization of single cells of varying sizes in a near-native state. The achievable resolution of the soft x-ray microscope is largely determined by the objective lens, but switching between objectives is extremely time-consuming and typically undertaken only during microscope maintenance procedures. Since the resolution of the optic is inversely proportional to the depth of focus, an optic capable of imaging the thickest cells is routinely selected. This unnecessarily limits the achievable resolution in smaller cells and eliminates the ability to obtain high-resolution images of regions of interest in larger cells. Here, we describe developments to overcome this shortfall and allow selection of microscope optics best suited to the specimen characteristics and data requirements. We demonstrate that switchable objective capability advances the flexibility of SXT to enable imaging cells ranging in size from bacteria to yeast and mammalian cells without physically modifying the microscope, and we demonstrate the use of this technology to image the same specimen with both optics.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental Technique for Producing and Recording Precise Particle Impacts on Transparent Window Materials

A new facility for making small particle impacts is being developed at NASA. Current sand/particle impact facilities are an erosion test and do not precisely measure and document the size and velocity of each of the impacting particles. In addition, evidence of individual impacts is often obscured by subsequent impacts. This facility will allow the number, size, and velocity of each particle to be measured and adjusted. It will also be possible to determine which particle produced damage at a given location on the target. The particle size and velocity will be measured by high speed imaging techniques. Information as to the extent of damage and debris from impacts will also be recorded. It will be possible to track these secondary particles, measuring size and velocity. It is anticipated that this additional degree of detail will provide input for erosion models and also help determine the impact physics of the erosion process. Particle impacts will be recorded at 90 degrees to the particle flight path and also from the top looking through the target window material.

Gray, Perry↗

Gold Nanoparticles AuNP Decorated on Fused Graphene-like Materials for Application in a Hydrogen Generation

The search for a sustainable, alternative fuel source to replace fossil fuels has led to an increased interest in hydrogen fuel. This combustible gas is not only clean-burning but can readily be produced via the hydrolysis of sodium borohydride. The main drawback of this reaction is that the reaction occurs relatively slowly and requires a catalyst to improve efficiency. This study explored a novel composite material made by combining gold nanoparticles and fused graphene-like materials (AuFGLM) as a catalyst for generating hydrogen via sodium borohydride. The novel fused graphene-like material (FGLM) was made with a sustainable dextrose solution and by using a pressure-processing method. Imaging techniques showed that FGLM appears to be an effective support template for nanoparticles. Transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) and Raman spectroscopy were used to characterize and determine the size, shape, and structure of nanoparticles and composites. The TEM study characterized the fused carbon backbone as it began to take on a rounder shape. The TEM images also revealed that the average diameter of the gold nanoparticle was roughly 23 nm. The FTIR study confirmed O-H, C-C, and C=O as functional groups in the materials. The EDS analysis showed that the composite contained approximately 6.3% gold by weight. The crystal structures of FGLM and AuFGLM were identified via P-XRD analysis. Various reaction conditions were used to test the catalytic ability of AuFGLM, including various solution pHs, temperatures, and doses of NaBH 4 . It was observed that optimal reaction conditions included high temperature, an acidic solution pH, and a higher dose of NaBH 4 . The activation energy of the reaction was determined to be 45.5 kJ mol -1 , and it was found that the catalyst could be used multiple times in a row with an increased volume of hydrogen produced in ensuing trials. The activation energy of this novel catalyst is competitive compared to similar catalysts and its ability to produce hydrogen over multiple uses makes the material an exciting choice for catalyzing the hydrolysis of NaBH 4 for use as a hydrogen fuel source.

08 HYDROGEN↗

A microCT-based platform to quantify drug targeting

Abstract Background Heterotopic ossification (HO) is a frequent and debilitating complication of traumatic musculoskeletal injuries and orthopedic procedures. Prophylactic dosing of botulinum toxin type A (BTxA) holds potential as a novel treatment option if accurately distributed throughout soft-tissue volumes where protection is clinically desired. We developed a high-resolution, microcomputed tomography (microCT)-based imaging strategy to assess drug distribution and validated this platform by quantifying distribution achieved via a prototype delivery system versus a single-bolus injection. Methods We injected an iodine-containing contrast agent (iodixanol 320 mg I/mL) into dissected rabbit musculature followed by microCT imaging and analysis. To contrast the performance of distributed versus bolus injections, a three-dimensional (3D) 64-cm 3 -printed soft-tissue holder was developed. A centered 2-cm 3 volume of interest (VOI) was targeted with a single-bolus injection or an equal volume distributed injection delivered via a 3D-printed prototype. VOI drug coverage was quantified as a percentage of the VOI volume that was < 1.0 mm from the injected fluid. Results The microCT-based approach enabled high-resolution quantification of injection distribution within soft tissue. The distributed dosing prototype provided significantly greater tissue coverage of the targeted VOI (72 ± 3%, mean ± standard deviation) when compared to an equal volume bolus dose (43 ± 5%, p = 0.031) while also enhancing the precision of injection targeting. Conclusions A microCT-based imaging technique precisely quantifies drug distribution within a soft-tissue VOI, providing a path to overcome a barrier for clinical translation of prophylactic inhibition of HO by BTxA. Relevance statement This platform will facilitate rapid optimization of injection parameters for clinical devices used to effectively and safely inhibit the formation of heterotopic ossification. Key points • MicroCT provides high-resolution quantification of soft-tissue drug distribution. • Distributed dosing is required to maximize soft-tissue drug coverage. • Imaging platform will enable rapid screening of 3D-printed drug distribution prototypes. Graphical Abstract

Ausk, Brandon J. (ORCID:0000000335338303)↗

Shockwave/Boundary-Layer Interaction Studies Performed in the NASA Langley 20-Inch Mach 6 Air Tunnel

This paper highlights results from a collaborative study performed by The University of Tennessee Space Institute (UTSI) and NASA Langley Research Center on the Shockwave/Boundary-Layer Interaction (SWBLI) generated by a cylindrical protuberance on a flat plate in a Mach 6 flow. The study was performed in the 20-Inch Mach 6 Air Tunnel at NASA Langley Research Center and consisted of two separate entries. In the first entry, simultaneous high-speed schlieren and high-speed pressure-sensitive paint (PSP) imaging – which was performed for the first time in the 20-Inch Mach 6 facility at NASA Langley – were performed as well as simultaneous high-speed schlieren and oil-flow imaging. In the second entry, the model configuration was modified to increase the size of the interaction region. High-speed schlieren and infrared thermography (IR) surface imaging were performed in this second entry. The goal of these tests was to characterize the SBLI in the presence of a laminar, transitional, and turbulent boundary layer using high-speed optical imaging techniques. AoA = sting angle-of-attack (°) dcylinder = cylinder diameter (mm) dtrip = cylindrical tripping element diameter (mm) Δshock = shock stand-off distance (mm) hcylinder = cylinder height (mm) htrip = cylindrical tripping element height (mm) HSS = high-speed schlieren M∞ = freestream Mach number PSP = pressure-sensitive paint Re∞ = freestream unit Reynolds number (m-1) SWBLI = shockwave/boundary-layer interaction θplate = model plate angle (°) Introduction his paper highlights two experimental entries performed in the 20-Inch Mach 6 Air Blowdown Tunnel at NASA Langley Research Center in collaboration with The University of Tennessee Space Institute (UTSI). The purpose of these entries was to characterize the dynamic shockwave/boundary-layer interaction (SWBLI) between a vertical cylinder on a flat plate and laminar, transitional (XSWBLI), and turbulent (SWTBLI) boundary layers with a freestream Mach number of 6 using non-intrusive optical diagnostics. Experiments performed by Murphree et al.1,2 were among the first to specifically characterize XSWBLI induced by a vertical cylinder on a flat plate geometry using several optical measurement techniques. Recent optical studies of XSWBLI phenomenon have been performed by UTSI at Mach 2 in their low-enthalpy blow wind tunnel3-8 and by Texas A&M University and UTSI at Mach numbers of 6 and 7 in their Adjustable Contour Expansion wind tunnel.9 The experiments described in this paper were intended to complement previous studies by expanding the freestream unit Reynolds number range, Re∞, over which the XSWBLI phenomena has been observed. Additionally these experiments, made possible under NASA’s new facility funding model under the Aeronautics Evaluation and Test Capabilities (AETC) project, promoted collaboration between university and NASA researchers. The initial entry in the 20-Inch Mach 6 Air Tunnel at NASA Langley occurred in December of 2016. Originally, testing was to occur in November of 2016 in the 31-Inch Mach 10 Air Tunnel at NASA Langley. This facility was chosen so that the XSWBLI phenomenon could be observed at much higher Mach numbers than had previously been attempted in ground test experiments. The model selected for this experiment, a 10° half-angle wedge with a sharp leading edge (described in detail in section II.B), had previously been used by Danehy et al. [10] for boundary layer transition studies using the nitric oxide planar laser-induced fluorescence (NO PLIF) flow visualization technique. In that work, it was determined that transition could be induced downstream of a single htrip = 1-mm tall, dtrip = 4-mm diameter cylindrical tripping element and that the streamwise location of the transition could be changed for a single Re∞ by changing the model angle-of-attack (AoA) (see Fig. A3 in Ref. [10] for more details). Based on the findings of that work, a decision was made to use the wedge model with the cylindrical tripping element to trip the boundary layer flow ahead of a cylindrical protuberance in order to achieve a XSWBLI. Unfortunately, the 31-Inch Mach 10 facility had been taken offline for repairs in October of 2016 and a decision was made to move the test to the 20-Inch Mach 6 facility. Since the behavior of the boundary layer with the chosen model configuration had not been studied before in that facility and the available test time was limited, the entry was considered to be exploratory and was used to collect spatially-resolved and time-resolved flow and surface visualization data that would be used to inform a second entry. Test techniques included simultaneous high-speed schlieren (HSS) captured at 160 kHz and high-speed pressure sensitive paint captured at 10 kHz as well as oil flow visualization, captured at 750 Hz. The second entry in the 20-Inch Mach 6 facility occurred in June and July of 2017. In this follow-on test, modifications to the wind tunnel model were made based on observations made during the first entry and included removing the cylindrical tripping element, increasing the size of the cylinder used to induce the SWBLI to increase the size of the interaction while simultaneously improving spatial resolution, and using a swept ramp array, similar to that described in Ref. [11], to trip the flow to turbulence. Simultaneous HSS (captured at 140 kHz, 100 kHz, and 40 kHz) and conventional IR thermography (captured at 30 Hz) imaging were performed simultaneously in this follow-on entry. This paper is intended to serve as a summary of the work performed during these two entries, to detail lessons learned from each entry, and to highlight some of the datasets acquired. Details on the experimental setup, model configuration, and techniques used are provided. Papers providing a more rigorous analysis of data acquired during the second entry, including statistical, spectral, and modal decomposition methods, can be found in Refs. [12,13]. An entry examining XSWBLI in the 31-Inch Mach 10 Blowdown Wind Tunnel facility is currently planned for mid-to-late calendar year 2019, pending the success of facility repairs. The work performed and described in this paper and the upcoming entry in the 31-Inch Mach 10 facility at NASA Langley have been made possible by NASA’s new facility funding model under the Aeronautics Evaluation and Test Capabilities (AETC) project. Wind Tunnel Facility All experiments discussed in this paper were performed in the 20-Inch Mach 6 Air Tunnel at NASA Langley Research Center. Specific details pertaining to this facility can be found in Refs. [14,15], with only a brief description of the facility provided here. For both entries, the nominal freestream unit Reynolds number was varied between 1.8×106 m-1 (0.5×106 ft-1) and 26.3×106 m-1 (8×106 ft-1). The nominal stagnation pressure was varied between 0.21 MPa and 3.33 MPa and the nominal stagnation temperature was varied between 480 K and 520 K to achieve the desired Re∞ condition. For all runs, the nominal freestream Mach number was 6. The nearly square test section is 520.7-mm (20.5-inches) wide by 508-mm (20-inches) high. Two 431.8-mm (17-inch) diameter windows made of Corning 7940, Grade 5F schlieren-quality glass serve as the side walls of the tunnel and provide optical access for the high-speed schlieren measurements. A rectangular window made of the same material as the side windows served as the top wall of the test section and provided optical access for the high-speed PSP and oil flow measurements. For the second entry, this top window was replaced with a Zinc Selenide (ZnSe) window with an anti-reflection coating capable of passing IR wavelengths between 8μm and 12μm with greater than 98% transmittance. The model was sting supported by a strut attached to a hydraulic system that allows for the model pitch angle to be adjusted between -5° to +55°. For the first entry, an initial pitch/pause sweep of the model AoA was performed to observe the resulting SWBLI. Ultimately, however, the sting pitch angle for this entry was fixed at +10.0° so that the angle of the top surface of the wedge relative to the streamwise axis of the tunnel (referred to herein as the plate angle, θplate), was θplate = 0°. For the second entry, θplate = 0° and θplate = -13.25° were initially tested with the swept ramp array (discussed in the following section) to determine which orientation produced conditions most favorable for XSWBLI to occur based on the heating signatures observed over the top surface of the model in the IR thermography images. Based on these initial tests, θplate = -13.25° was set for the remainder of the runs in the second entry. For both entries, any model changes were performed in a housing located beneath the closed test section. Prior to performing a run of the tunnel, the housing was sealed and the tunnel started. Once the appropriate freestream conditions were achieved, the model was injected into the test section using a hydraulic injection system. B. Model Geometry For all runs, a 10° half-angle (20° full-angle) wedge model with a sharp leading edge was used. The model is described in detail in Refs. [10,16]. The top surface of the sharp leading edge of the model extended 47.8 mm from its upstream-most edge to a junction with the upstream edge of a stainless steel top plate that then extended an (a) (c) (b) Fig. 1 (a) Schematic of top surface of wedge model with gas seeding insert, (b) perspective view of the model in the 20-Inch Mach 6 tunnel with centerline pressure orifices on sharp leading edge, and (c) a perspective view of the model with stainless steel (top) and SLA middle insert (bottom) during the first entry. Flow occurs from left to right.

Bathel, Brett F.↗

Millimeter Wave Synthetic Aperture Imaging System with a Unique Rotary Scanning System

In recent years, millimeter wave imaging techniques, using synthetic aperture focusing and holographical approaches, have shown tremendous potential for nondestructive testing applications, involving materials and structures used in space vehicles, including the space shuttle external fuel tank spray on foam insulation and its acreage heat tiles. The ability of signals at millimeter wave frequencies (30 - 300 GHz) to easily penetrate inside of low loss dielectric materials, their relatively small wavelengths, and the possibility of detecting coherent (magnitude and phase) reflections make them suitable for high resolution synthetic aperture focused imaging the interior of such materials and structures. To accommodate imaging requirements, commonly a scanning system is employed that provides for a raster scan of the desired structure. However, most such scanners, although simple in design and construction, are inherently slow primarily due to the need to stop and start at the beginning and end of each scan line. To this end, a millimeter wave synthetic aperture focusing system including a custom-designed transceiver operating at 35 - 45 GHz (Q-band) and unique and complex rotary scanner was designed and developed. The rotary scanner is capable of scanning an area with approximately 80 cm in diameter in less than 10 minutes at step sizes of 3 mm and smaller. The transceiver is capable of producing accurate magnitude and phase of reflected signal from the structure under test. Finally, a synthetic aperture focusing algorithm was developed that translates this rotary-obtained magnitude and phase into a synthetic aperture focusing image of inspected structures. This paper presents the design of the transceiver and the rotary scanning system along with showing several images obtained with this system from various complicated structures.

Ghasr, M. T.↗

Coherent Doppler lidar for automated space vehicle rendezvous, stationkeeping and capture

The inherent spatial resolution of laser radar makes ladar or lidar an attractive candidate for Automated Rendezvous and Capture application. Previous applications were based on incoherent lidar techniques, requiring retro-reflectors on the target vehicle. Technology improvements (reduced size, no cryogenic cooling requirement) have greatly enhanced the construction of coherent lidar systems. Coherent lidar permits the acquisition of non-cooperative targets at ranges that are limited by the detection capability rather than by the signal-to-noise ratio (SNR) requirements. The sensor can provide translational state information (range, velocity, and angle) by direct measurement and, when used with any array detector, also can provide attitude information by Doppler imaging techniques. Identification of the target is accomplished by scanning with a high pulse repetition frequency (dependent on the SNR). The system performance is independent of range and should not be constrained by sun angle. An initial effort to characterize a multi-element detection system has resulted in a system that is expected to work to a minimum range of 1 meter. The system size, weight and power requirements are dependent on the operating range; 10 km range requires a diameter of 3 centimeters with overall size at 3 x 3 x 15 to 30 cm, while 100 km range requires a 30 cm diameter.

Bilbro, James A.↗

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LITE-SM: A Light Sheet Illuminator Compatible with Super Resolution and Single Molecule Imaging

The LITE-SM (hereinafter referred to as the Tilt-SM) is a light sheet illumination system purpose-built for single molecule (SM) imaging. SM imaging is a fluorescence imaging technique where individual molecules can be tracked in living cells/tissues in real time allowing for unprecedented insights into the intracellular dynamics of these molecules. The innovative all-mirror optical design greatly reduces/eliminates the aberrations that plague lens-based designs. This iteration of the Tilt-SM has significantly better optical performance then its predecessor with over 10x increase in optical power at the sample, allowing for the use of much smaller and more cost-effective lasers then the original Phase 1 system. Excellent STORM imaging as well as SM tracking has been achieved, satisfying the key objectives of this study.

59 BASIC BIOLOGICAL SCIENCES↗

Updates on MURAVES Project at Mt. Vesuvius

The MUon RAdiography of VESuvius (MURAVES) project aims to employ muography imaging techniques to investigate the internal structure of the summit of Mount Vesuvius, an active volcano located near Naples, Italy. This paper reports recent advancements in data analysis and simulation tools that significantly improve the quality and reliability of the experiment’s results. A new track selection method, referred to as the Golden Selection, has been developed to identify high-quality muon tracks by applying an improved χ 2 -based criterion. This method enhances the signal-to-background ratio and improves the resolution of the resulting muographic images. Moreover, the simulation framework has been upgraded through the integration of the MULDER (MUon simuLation for DEnsity Reconstruction) library, which consolidates the functionalities of previously used libraries into a single, unified platform. MULDER enables efficient and accurate modeling of muon flux variations induced by topographical features. A good agreement is observed between the simulated and measured muon flux maps, validating the effectiveness of the new analysis and simulation approaches.

Cosmic rays↗

Adaptive optical third-harmonic generation microscopy for in vivo imaging of tissues

Third-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plant Brachypodium distachyon. In all instances, aberration correction led to enhancements in image quality.

60 APPLIED LIFE SCIENCES↗

Image Analysis Based on Soft Computing and Applied on Space Shuttle During the Liftoff Process

Imaging techniques based on Soft Computing (SC) and developed at Kennedy Space Center (KSC) have been implemented on a variety of prototype applications related to the safety operation of the Space Shuttle during the liftoff process. These SC-based prototype applications include detection and tracking of moving Foreign Objects Debris (FOD) during the Space Shuttle liftoff, visual anomaly detection on slidewires used in the emergency egress system for the Space Shuttle at the laJlIlch pad, and visual detection of distant birds approaching the Space Shuttle launch pad. This SC-based image analysis capability developed at KSC was also used to analyze images acquired during the accident of the Space Shuttle Columbia and estimate the trajectory and velocity of the foam that caused the accident.

Dominquez, Jesus A.↗

Development of Stochastic Voronoi Lattice Structures via Two-Photon Polymerization

Low-density polymer foams of varying sizes, shapes, and densities are of specific interest to the inertial confinement fusion (ICF) program and related high-energy density plasma physics research. Historically, these foams are comprised of polystyrene or other low atomic number materials and have densities in the 30 to 300 mg/cm 3 range. However, at the lower end of this density range, these traditional polymer foams become fragile and difficult to cast and machine into the geometries needed. Recently, the need by experimentalists for materials with densities below 30 mg/cm 3 has increased. To address these needs, we are developing three-dimensional (3-D) printing techniques to create high-precision, low-density, and repeatable complex lattice structures. Using two-photon polymerization 3-D printing, we recently developed the first 5 mg/cm3 low-density lattice structure having an annular hemispherical shape. These microscale to mesoscale structures were modeled and designed using the nTopology software, specifically utilizing the "Voronoi volume lattice" and "random points in body" option blocks. All printing operations were performed using the Nanoscribe Photonic Professional GT instrument. Characterization of these 3-D structures was conducted using various microscopic and X-ray tomographic imaging techniques. Furthermore, overall printed part sizes ranged from 1 to 5 mm in diameter and were composed of lattice ligaments having thicknesses in the 3- to 5-µm range. These structures have been incorporated into ICF targets recently shot on both the University of Rochester’s Laboratory of Laser Energetics Omega laser and the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Luminescent barometry in wind tunnels

A flexible and relatively inexpensive method and apparatus are described for continuous pressure mapping of aerodynamic surfaces using photoluminescence and imaging techniques. Platinum octaethylporphyrin (PtOEP) has a phosphorescence known to be quenched by oxygen. When dissolved in a silicone matrix, PtOEP may be distributed over a surface as a thin, uniform film. When the film is irradiated with ultraviolet light, the luminescence intensity provides a readily detectable, qualitative surface flow visualization. Moreover, since the luminescence intensity is found to be inversely proportional to the partial pressure of oxygen, a quantitative measure of pressure change may be obtained using a silicon target vidicon or a charge-coupled device video sensor to measure intensity. Luminescent images are captured by a commercial frame buffer board. Images taken in wind tunnels during airflow are ratioed to images taken under ambient 'wind-off' conditions. The resulting intensity ratio information is converted to pressure using calibration curves of I0/I vs p/p0, where I0 is the intensity at ambient pressure p0 and I is the intensity at any other pressure p.

Kavandi, Janet↗

Imaging local luminescence variations in CdSe 0.1 Te 0.9 thin films grown by the colossal grain growth process

Clear visualization and understanding of luminescence properties of grain interiors and grain boundaries in polycrystalline thin-film photovoltaic materials are crucial to achieving high-performance solar cells. Luminescence-based measurements, for example, reveal sub-bandgap energetic disorder or impurity-related radiative transitions in these materials, and when performed in the absolute scale, they can show the extent of voltage-limiting non-radiative recombination. Here we use a hyperspectral imaging technique to investigate inter- and intra-grain photoluminescence variations in polycrystalline CdSe 0.1 Te 0.9 films made by the colossal grain growth process. We observe that grain boundaries show higher luminescence than grain interiors for all energies below the bandgap energy. Multiple distinct sub-bandgap defect transitions are detected and determined to be related to donor-acceptor pair impurities. A comparison of the excitation-intensity-dependent photoluminescence at the grain boundaries with grain interiors suggests that carrier concentration is higher at grain boundaries. This finding is supported by photoemission electron microscopy imaging of the films, showing approximately 70 meV upward energy shift in the band structure at the grain boundaries. Finally, we investigate a dramatic thermal quenching behavior related to the donor-acceptor pairs luminescence over a temperature range and use a rate-equation model to attribute it to the sudden redirection of the radiative recombination channels to non-radiative channels with increasing temperature.

14 SOLAR ENERGY↗

Observation of hydrodynamic plasmons and energy waves in graphene

Thermally excited electrons and holes form a quantum-critical Dirac fluid in ultraclean graphene and their electrodynamic responses are described by a universal hydrodynamic theory. The hydrodynamic Dirac fluid can host intriguing collective excitations distinctively different from those in a Fermi liquid. Here we report the observation of the hydrodynamic plasmon and energy wave in ultraclean graphene. In this study, we use the on-chip terahertz (THz) spectroscopy technique to measure the THz absorption spectra of a graphene microribbon as well as the propagation of the energy wave in graphene close to charge neutrality. We observe a prominent high-frequency hydrodynamic bipolar-plasmon resonance and a weaker low-frequency energy-wave resonance of the Dirac fluid in ultraclean graphene. The hydrodynamic bipolar plasmon is characterized by the antiphase oscillation of massless electrons and holes in graphene. The hydrodynamic energy wave is an electron-hole sound mode with both charge carriers oscillating in phase and moving together. The spatial–temporal imaging technique shows that the energy wave propagates at a characteristic speed of $V_f$ / $ \sqrt2$ near the charge neutrality. Our observations open new opportunities to explore collective hydrodynamic excitations in graphene systems.

36 MATERIALS SCIENCE↗

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.↗