Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Dosimetry Using a Linear Mosfet-Array Dosimeter to Determine the Urethra Dose In {sup 125}I Permanent Prostate Implants

Purpose: In vivo dosimetry during brachytherapy of the prostate with {sup 125}I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Methods and Materials: Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Results: Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% {+-} 10.7% (1 SD). In the low-dose region outside the prostate (< 100 Gy), larger deviations occurred. Conclusions: MOSFET detectors are suitable for in vivo dosimetry during {sup 125}I brachytherapy of prostate cancer. An action level of {+-} 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Soft-Tissue Implanted Markers and Bony Anatomy Alignments for Image-Guided Treatments of Head-and-Neck Cancers

Purpose: To compare the geometric alignments of soft-tissue implanted markers to the traditional bony-based alignments in head-and-neck cancers, on the basis of daily image guidance. Dosimetric impact of the two alignment techniques on target coverage is presented. Methods and Materials: A total of 330 retrospective alignments (5 patients) were performed on daily megavoltage computed tomography (MVCT) image sets using both alignment techniques. Intermarker distances were tracked for all fractions to assess marker interfractional stability. Using a deformable image registration algorithm, target cumulative doses were calculated according to generated shifts on daily MVCT image sets. Target D95 was used as a dosimetric endpoint to evaluate each alignment technique. Results: Intermarker distances overall were stable, with a standard deviation of <1.5 mm for all fractions and no observed temporal trends. Differences in shift magnitudes between both alignment techniques were found to be statistically significant, with a maximum observed difference of 8 mm in a given direction. Evaluation of technique-specific dose coverage based on D95 of target clinical target volume and planning target volume shows small differences (within +-5%) compared with the kilovoltage CT plan. Conclusion: The use of daily MVCT imaging demonstrates that implanted markers in oral tongue and soft-palate cancers are stable localization surrogates. Alignments based on implanted markers generate shifts comparable overall to the traditional bony-based alignment, with no observed systematic difference in magnitude or direction. The cumulative dosimetric impact on target clinical target volume and planning target volume coverage was found to be similar, despite large observed differences in daily alignment shifts between the two techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation Between Pre- and Postimplant Dosimetry for Iodine-125 Seed Implants for Localized Prostate Cancer

Purpose: In order to evaluate implant quality for permanent prostate brachytherapy in patients with localized prostate cancer, American Brachytherapy Society and ESTRO guidelines recommend that postimplant dosimetry should be performed. To understand more about the relationship between pre- and postimplant dosimetry, a comparison was made of patients who received iodine-125 ({sup 125}I) brachytherapy between March 1995 and the end of 2004, using a preplan technique. Methods and Materials: CT postimplant dosimetry was available for 707 patients. Detailed dose volume analysis was performed using both preimplant ultrasound and postimplant CT data sets for a subgroup of 445 patients. The following parameters were compared: prostate volume covered by 100% of the prescription dose (Vp100), Vp150, and Vp200 and dose to 90% (D90) of the prostate. In addition, volume implanted (Vi) parameters were used to compare pre- and postimplant dosimetry. Vi parameters describe dose levels inside the patient, based on number of seeds, seed activity, and their spatial distribution relative to each other, without reference to the actual prostate volume or position. Results: The mean {+-} standard deviation values of preimplant (34.7 {+-} 8.9 cm{sup 3}) and postimplant (36.7 {+-} 9.4 cm{sup 3}) prostate volumes were similar. The mean ({+-}standard deviation) planned D90 was 183.4 ({+-}12.1) Gy while the D90 that was achieved was 145.5 ({+-}20.4) Gy. Over the study period, there was a steady increase of the average D90. Postimplant CT D90 and Vp100 values correlated significantly (R = 0.84; p < 0.001). The Vi and Vp parameters all showed a strong correlation. Conclusions: In this study, we showed that there is a strong correlation between transrectal ultrasound-based preimplant and CT-based postimplant dosimetry. The excellent correlation between prostate D90 and V100 values demonstrates they are both equally valid quality indices. Vi parameters are an additional measure that can be used to assess the quality of the implant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of MR Imaging/MR Spectroscopy-Planned Focal Partial Salvage Permanent Prostate Implant (PPI) for Localized Recurrence After Initial PPI for Prostate Cancer

Purpose: To assess the feasibility of magnetic resonance imaging (MRI)-planned partial salvage permanent prostate implant (psPPI) among patients with biopsy-proven local recurrence after initial PPI without evidence of distant disease. Methods and Materials: From 2003-2009, 15 patients underwent MRI/magnetic resonance spectroscopy (MRS) planning for salvage brachytherapy (psPPI, I-125 [n=14; 144 Gy]; Pd-103 [n=1; 125 Gy]) without hormone therapy. Full dose was prescribed to areas of recurrence and underdosage, without entire prostate implantation. Limiting urethral and rectal toxicity was prioritized. Follow-up was from salvage date to prostate-specific antigen (PSA) concentration failure (Phoenix criteria = nadir + 2.0; ASTRO = 3 consecutive rises), recurrence, distant metastases, or last follow-up PSA level. Progression-free survival (PFS) was defined as no PSA failure or biopsy-proven recurrence without all-cause mortality. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Results: At salvage, median age was 68 years, and PSA concentration was 3.5 ng/mL (range, 0.9-5.6 ng/mL). Abnormal MRI/MRS findings were evident in 40% of patients. Biopsy-proven recurrences consisted of a single focus (80%) or 2 foci (20%). At recurrence, Gleason score was 6 (67%) or {>=}7 (27%). Median interval between initial and salvage implantation was 69 months (range, 28-132 months). psPPI planning characteristics limited doses to the rectum (mean V100 = 0.5% [0.07 cc]) and urethra (V100 = 12% [0.3 cc]). At median follow-up (23.3 months; range, 8-88 months), treatment failure (n=2) resulted only in localized recurrence; both patients underwent second psPPI with follow-up PSA tests at 12 and 26 months, resulting in 0.6 and 0.7 ng/mL, respectively. American Society for Radiation Oncology PFS rates at 1, 2, and 3 years were 86.7%, 78.4%, and 62.7%, respectively, with 5 patients for whom treatment failed (n=3 with negative transrectal ultrasound-guided biopsy results). Phoenix PFS rates at 1, 2, and 3 years were 100%, 100%, and 71.4%. 73%, respectively; achieved PSA nadir of <0.5 ng/mL; and 47% of patients had a nadir of <0.1 ng/mL. Treatment-related toxicity was minimal, with no operative interventions, fistulas, or other grade {>=}3 gastrointestinal (GI)/genitourinary (GU) toxicity. Thirteen percent had grade 1 GI and 33% had grade 2 GU toxicities. Postsalvage, 20% of patients had no erectile dysfunction, 67% of patients had medication-responsive erectile dysfunction, and 13% of patients had erectile dysfunction refractory to medication. Conclusions: Focal psPPI with MR-planning in highly selected patients is feasible with short-term control comparable to conventional salvage, with less toxicity. Longer follow-up is needed to confirm its impact on quality of life and treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vertically oriented ZrO 2 –TiO 2 –Nb 2 O 5 –Al 2 O 3 mixed nanopatterned bioceramics on Ti6Al7Nb implant assessed by laser spallation technique

Recently, reports on the fabrication of nonstructural configuration have generated scientific interest due to increased awareness of the oxide nanotubes in the biomedical implant field and other industrial approaches. In this paper, highly ordered ZrO 2 –TiO 2 –Nb 2 O 5 –Al 2 O 3 nanotube arrays were grown by physical vapor deposition (PVD) of a zirconium layer on titanium-niobium alloy implant (IMPTi67) and succeeding anodic oxidation at a constant voltage (60 V) with exposure times ranging from 30 to 300 min. To crystallize the resulting mixed oxide nanotubes, heat treatment was also applied. The nanotubes were placed in an atmospheric furnace at temperatures ranging from 450 to 800 °C for 2 h. This treatment provided a morphological evolution was strongly influenced by the anodization time, where highly aligned bamboo-shaped oxide nanotubes (161 ± 44 nm in inside diameter and ~1 μm in length) were formed after 300 min of anodization. After annealing at temperature below 500 °C, the nano-array configuration remained stable and the average inner diameter decreased to around 40 nm. The effects of anodically fabrication time on the adhesion strength of four-phase multilayered mixed oxide nanotubes on anodized Zr/IMPTi67 surfaces assed by microscratch analysis. From the results, increasing the annealing temperature further to 800 °C fully destroyed the nanotubes and consequently the tubular arrangement was converted to a coarse grain structure. It was revealed that annealing at 450 °C for 2 h was the optimum conditions for stable nanotubular array generation, where the highest adhesion strength (shifted from 2595.59 to 2640.12 mN), microhardness (372 HV) and hydrophilicity (15 ± 1°) were recorded. It is notify that the adhesion strength of highly ordered mixed nanotubes was remarkably decreased after thermal treatment at 800 °C (1817.51 mN). Through the laser spallation analysis, the intrinsic adhesion strength of the Zr/IMPTi67 interface was found to be at 63 MPa, while the first stages of failure occurred at a stress state of 35 MPa. The adhesion of the film with the tubular structure proved to have a significantly larger adhesion strength of 246 MPa for the complete failure and 203 MPa for incipient stages of spallation. Finally, the considered surface modification can be an effective step in determining the interface strength between biomedical implants and the nanostructured coatings.

36 MATERIALS SCIENCE↗

Effect of exposure environment on surface decomposition of SiC-silver ion implantation diffusion couples

SiC is a promising material for nuclear applications and is a critical component in the construction of tristructural isotropic (TRISO) fuel. A primary issue with TRISO fuel operation is the observed release of 110m Ag from intact fuel particles. The release of Ag has prompted research efforts to directly measure the transport mechanism of Ag in bulk SiC. Recent research efforts have focused primarily on Ag ion implantation designs. The effect of the thermal exposure system on the ion implantation surface has been investigated. Results indicate the utilization of a mated sample geometry and the establishment of a static thermal exposure environment is critical to maintaining an intact surface for diffusion analysis. In conclusion, the nature of the implantation surface and its potential role in Ag diffusion analysis are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observations of Ag diffusion in ion implanted SiC

The nature and magnitude of Ag diffusion in SiC has been a topic of interest in connection with the performance of tristructural isotropic (TRISO) coated particle fuel for high temperature gas-cooled nuclear reactors. Ion implantation diffusion couples have been revisited to continue developing a more complete understanding of Ag fission product diffusion in SiC. Ion implantation diffusion couples fabricated from single crystal 4H-SiC and polycrystalline 3C-SiC substrates and exposed to 1500–1625°C, were investigated in this study by transmission electron microscopy and secondary ion mass spectrometry (SIMS). The high dynamic range of SIMS allowed for multiple diffusion régimes to be investigated, including enhanced diffusion by implantation-induced defects and grain boundary (GB) diffusion in undamaged SiC. Lastly, estimated diffusion coefficients suggest GB diffusion in bulk SiC does not properly describe the release observed from TRISO fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of thermal oxidation on helium implanted pure iron

The impact of thermal oxidation on Helium (He) implanted pure iron (Fe) was investigated to experimentally evaluate how thermal oxidation influences the diffusion and distribution of He within the material. In case of the sample with the lowest dose (2 × 10 17 ions/cm 2 ), the thinnest oxide layer was observed compared to the non-implanted pure Fe. It is due to He nano bubbles implanted in the material, which hinder the diffusion of Fe ions necessary for forming the oxide layer. For the medium dose sample (5 × 10 17 ions/cm 2 ), the oxide layer was slightly thicker than that of the lowest dose, however it had more porous structure due to the numerous nano He bubbles. In addition, a large bubble region around 150–200 nm depth was generated. Here, the highest dose sample (1 × 10 18 ions/cm 2 ) was observed that the escape of He was accelerated by the large amount of nano He bubbles from within the metal, forming a porous Fe matrix on the top surface and an oxide layer that is very porous but thicker than those of lower doses.

He implantation↗

Implant breast reconstruction followed by radiotherapy: Can helical tomotherapy become a standard irradiation treatment?

To evaluate the benefits and limitations of helical tomotherapy (HT) for loco-regional irradiation of patients after a mastectomy and immediate implant-based reconstruction. Ten breast cancer patients with retropectoral implants were randomly selected for this comparative study. Planning target volumes (PTVs) 1 (the volume between the skin and the implant, plus margin) and 2 (supraclavicular, infraclavicular, and internal mammary nodes, plus margin) were 50 Gy in 25 fractions using a standard technique and HT. The extracted dosimetric data were compared using a 2-tailed Wilcoxon matched-pair signed-rank test. Doses for PTV1 and PTV2 were significantly higher with HT (V95 of 98.91 and 97.91%, respectively) compared with the standard technique (77.46 and 72.91%, respectively). Similarly, the indexes of homogeneity were significantly greater with HT (p = 0.002). HT reduced ipsilateral lung volume that received {>=}20 Gy (16.7 vs. 35%), and bilateral lungs (p = 0.01) and neighboring organs received doses that remained well below tolerance levels. The heart volume, which received 25 Gy, was negligible with both techniques. HT can achieve full target coverage while decreasing high doses to the heart and ipsilateral lung. However, the low doses to normal tissue volumes need to be reduced in future studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of Defects in N-type 4H-SiC After High-Energy N Ion Implantation by RBS-Channeling and Raman Spectroscopy

Implantation with 1 MeV N ions was performed at room temperature in n-type 4H-SiC(0001) to four implantation fluences (or doses in dpa (displacements per atom) at the damage peak) of 1.5×1013(0.0034), 7.8×1013(0.018), 1.5×1014(0.034), and 7.8×1014(0.18) ions/cm2, respectively. The evolution of disorder was studied using Rutherford backscattering spectrometry in channeling mode (RBS-C) and Raman spectroscopy. The disorder in the Si sub-lattice was found to be less than 10% for the dpa of 0.0034 and 0.0178 and increased to 40% and 60% for the dpa of 0.034 and 0.178 respectively. Raman Spectroscopy was performed using a green laser of wavelength 532 nm as excitation source. The normalized Raman Intensity, In shows disorder of 41%, 69%, 77% and 100% for the dpa of 0.0034, 0.017, 0.034 and 0.178 respectively. In this paper, the characterizations of the defects produced due to the Nitrogen implantation in 4H-SiC are presented and the results are discussed.

Environmental Molecular Sciences Laboratory↗

Taming the Pseudoelastic Response of Nitinol Using Ion Implantation

Implantation of Ni 50.5 Ti 49.5 wire with 30 MeV Ni 6+ ions at doses (< 0.1 DPA) typically smaller than employed in the literature is shown to systematically alter the pseudoelastic response, with extrema in Berkovich nanoindentation load (+50%), hysteresis (–60%), and recoverable displacement (–19%) occurring at ~ 3.6 μm below the implantation surface. These extraordinary values are attributed to ~ 10 to 20 nm amorphous clusters that constrain the stress-induced B2-B19' phase transformation. This is substantiated by phase field simulations of crystalline-amorphous composites and molecular dynamics simulations of crystalline-vacancy cluster composites showing the spatial refinement of martensite caused by nm-scale defects. Finally, the results suggest that ion implantation may potentially expand the processing and performance space for NiTi, by creating amorphous defects at smaller length scales than dislocation substructures produced by conventional deformation processing.

36 MATERIALS SCIENCE↗

Stress engineering for crack and dendrite prevention in solid electrolytes via ion implantation

Solid-state batteries represent a promising technology that offers safer and more densely packed energy storage. A primary cause of failure in solid-state cells is the penetration of metal dendrites through the solid electrolyte. Here, we report that fluorine-ion implantation can enhance the mechanical resistance of solid electrolyte Li 6.5 La 3 Zr 1.5 Ta 0.5 O 12 to dendrite propagation by inducing residual compressive stress in the subsurface of the electrolyte. Ion implantation modifies subsurface residual stress and also alters the electrolyte’s surface, resulting in multifunctional enhancement. The combined chemical and mechanical effects of ion implantation enable reversible lithium metal stripping and plating at elevated current densities while enhancing air stability and mitigating the formation of a harmful carbonate layer at the surface. This study provides new insights into a scalable dendrite-suppression strategy for designing solid-state batteries suitable for cycling at room temperature and low stack pressures.

25 ENERGY STORAGE↗

Tuning Chiral Anomaly Signature in a Dirac Semimetal via Fast-Ion Implantation

Cd 3 As 2 is a Dirac semimetal that hosts a chiral anomaly, functioning as a platform to realize energy applications. We use fast-ion implantation to enhance the negative longitudinal magnetoresistance (NLMR)─signature of a chiral anomaly─in Nb-doped Cd 3 As 2 thin films. High-energy ion implantation is used to investigate semiconductors and nuclear materials but is rarely employed to study topological materials. We use electrical transport and transmission electron microscopy to characterize the NLMR and crystallinity of Nb-doped Cd 3 As 2 . We find surface-doped thin films display a maximum NLMR around B = 7 T and bulk-doped thin films display a maximum over B = 9 T─all while maintaining crystallinity. This is more than a 100% relative enhancement of the maximum NLMR compared to pristine Cd 3 As 2 . As a result, our work demonstrates the potential of high-energy ion implantation as a practical route to explore chiralitronic properties in topological semimetals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low Energy Implantation into Transition-Metal Dichalcogenide Monolayers to Form Janus Structures

Atomically-thin two-dimensional (2D) materials face significant energy barriers for synthesis and processing into functional metastable phases such as Janus structures. Here, in this study, the controllable implantation of hyperthermal species from pulsed laser deposition (PLD) plasmas is introduced as a top-down method to compositionally engineer 2D monolayers. The kinetic energies of Se clusters impinging on suspended monolayer WS 2 crystals were controlled in the <10 eV/atom range with in situ plasma diagnostics to determine the thresholds for selective top layer replacement of sulfur by selenium for the formation of high quality WSSe Janus monolayers at low (300 °C) temperatures, and bottom layer replacement for complete conversion to WSe 2 . Atomic-resolution electron microscopy and spectroscopy in tilted geometry confirm the WSSe Janus monolayer. Molecular dynamics simulations reveal that Se clusters implant to form disordered metastable alloy regions, which then recrystallize to form highly ordered structures, opening the door for low-energy implantation by PLD as a novel method to explore the synthesis of 2D Janus layers and alloys of variable composition.

2D materials↗

Lifetime and resistivity modifications induced by helium implantation in silicon: Experimental analysis with an ac profiling technique

The effect of He ion bombardment on silicon based devices can be seen observing a change of their electric properties, that are relevant for their application, as well as through the modification of some local properties, in particular, resistivity and recombination lifetime, that in turn reflect the microscopic modification of their structure. The knowledge of the relation between these two aspects of the modifications induced by ion implantation would represent a powerful tool to design new devices and processes. This paper presents the results of an experimental analysis, where the modifications of the electrical properties of power devices, induced by helium implantation, were correlated to both the local recombination lifetime and the resistivity depth profile measured using a differential ac technique. Various measurements were performed for a wide range of temperatures to obtain information on the energy levels of the recombination centers which are responsible for the observed variations of the local properties of the device. The investigation was performed varying both the beam energy (from 3.5 to 5.8 MeV) and dose (1x10{sup 8}-5x10{sup 11} ions/cm{sup 2}), providing a complete picture of the implantation effects. Finally, an application to the switching behavior of a fast recovery power diode is presented.

36 MATERIALS SCIENCE↗

Investigation of plasma immersion ion implantation of nickel-titanium rod by multiple-grid particle-in-cell simulation

A multiple-grid-particle-in-cell numerical method has been developed. This method uses grids of different cell sizes and details are needed in only one part of the simulation region and not others. Hence, there are fewer nodes in the simulation thereby reduced computational time without sacrificing details. In the multiple-grid system, a phenomenon is identified to arise at the interface between two grids and a half-cell weighting method is utilized to solve the weighting issue at the boundary. It is shown that the expression of the change of momentum has no weighting function. This method is employed to numerically simulate the plasma immersion ion implantation process into a nickel titanium rod measuring 50 mm long and 4.8 mm in diameter used in orthopaedic surgery. To conduct more uniform implantation, the NiTi rod is elevated on the sample stage by a metal rod. The nitrogen implantation fluences and depth profiles are simulated and compared to experimental values determined by x-ray photoelectron spectroscopy.

36 MATERIALS SCIENCE↗

Effects of hydrogen implantation temperature on InP surface blistering

We have investigated the effects of hydrogen implantation temperature on the ion-cut process of InP by examining the correlation between surface blistering and the ion induced damage, hydrogen distribution, and strain. Using Rutherford backscattering spectrometry, elastic recoil detection, and x-ray diffraction, it was found that both the point defects induced by the hydrogen implantation and the in-plane compressive stress were necessary for hydrogen trapping and H-platelet nucleation and growth. The control of implantation temperature is crucial for creating sufficient defects and strain to induce surface blistering or layer exfoliation.

36 MATERIALS SCIENCE↗