Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Power Flow Solution Methods for Combined Transmission and Distribution Systems

High distributed PV penetration makes the distribution systems more active and increases their impact on the upstream transmission grid. To facilitate the studies on this area, this paper proposes a power flow (PF) model and formulation of combined transmission and distribution (T&D) power systems. The formulation is based on the physical coupling of transmission and distribution grids. The unbalanced nature of distribution feeders and voltage regulators are modeled so that the resulting PF balance equations in distribution systems are similar to those in the interconnected transmission system. The formulated nonlinear PF equations are solved using the proposed unified and sequential methods. Both methods are verified and compared with each other using several combined T&D power systems. A multi-period PF simulation is also included to demonstrate the capability of the proposed formulation and solution methods in capturing the influences of high distributed PV penetration on transmission level.

Nguyen, Quan H.↗

Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN↗

Impacts of hybridization and forecast errors on the probabilistic capacity credit of batteries

Battery storage is increasingly identified as being among the least-cost mix of technologies in the evolving U.S. electricity mix. This study explores the marginal capacity credit of batteries using a probabilistic, reliability-based, effective firm capacity method, which we apply for multiple battery power ratings, durations, coupling types, deployment locations, and dispatch profiles within a test system that is based on the Texas Interconnection in the year 2024. We find that the capacity credits for all battery durations depend on their ability to predict the timing of reliability events. Even 1-2 h forecast errors - resulting in early or delayed battery discharging relative to the onset of a reliability event - lead pronounced capacity credit reductions, especially for 4-h duration batteries. Coupling batteries with solar mitigates the uncertainty associated with a shorter-duration battery's availability during reliability events, primarily due to the relatively high solar capacity credit in our test system. Coupled (or hybrid) system designs with oversized solar arrays, the ability to charge the coupled battery with grid energy, and larger batteries lead to the greatest capacity credit benefits of hybridization. We do not see evidence that the hybrid capacity credit exceeds the sum of the separate battery and solar capacity credits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Communications and control for electric power systems

The first section of the report describes the AbNET system, a hardware and software communications system designed for distribution automation (it can also find application in substation monitoring and control). The topology of the power system fixes the topology of the communications network, which can therefore be expected to include a larger number of branch points, tap points, and interconnections. These features make this communications network unlike any other. The network operating software has to solve the problem of communicating to all the nodes of a very complex network in as reliable a way as possible even if the network is damaged, and it has to do so with minimum transmission delays and at minimum cost. The design of the operating protocols is described within the framework of the seven-layer Open System Interconnection hierarchy of the International Standards Organization. Section 2 of the report describes the development and testing of a high voltage sensor based on an electro-optic polymer. The theory of operation is reviewed. Bulk fabrication of the polymer is discussed, as well as results of testing of the electro-optic coefficient of the material. Fabrication of a complete prototype sensor suitable for use in the range 1-20 kV is described. The electro-optic polymer is shown to be an important material for fiber optic sensing applications. Appendix A is theoretical support for this work. The third section of the report presents the application of an artificial neural network, Kohonen's self-organizing feature map, for the classification of power system states. This classifier maps vectors of an N-dimensional space to a 2-dimensional neural net in a nonlinear way preserving the topological order of the input vectors. These mappings are studied using a nonlinear power system model.

Kirkham, H.↗

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop (Poster)

This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Contingency Analysis Tool 2.0 User Manual with Test System Examples

This document introduces Version 2 of the Dynamic Contingency Analysis Tool (DCAT) software package developed by Pacific Northwest National Laboratory and serves as a guide for using this package to conduct cascading failure simulations for the electric power system. The DCAT is an open-platform and publicly available software; it is intended to help develop applications that aim to improve the capabilities of power system planning engineers to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. Outputs from the DCAT will support finding mitigating actions to reduce the risk of cascading outages in technically sound and effective ways. This manual provides detailed instructions on how to use this tool on multicore Windows workstations or servers. In the public version of DCAT, several improvements have been made over the previous version: (1) it was modularized; (2) a graphical user interface (GUI) was developed; (3) a new version of the MPjobs parallel processing module was incorporated; and (4) a batch-processing function was added. The features of the DCAT GUI are described, including some examples of how to use the GUI to perform simulations. A full explanation of the DCAT methodology is available in the Phase 1 report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Analysis of System Balance and Architectural Trends Based on Top500 Supercomputers

Supercomputer design is a complex, multi-dimensional optimization process, wherein several subsystems need to be reconciled to meet a desired figure of merit performance for a portfolio of applications and a budget constraint. However, overall, the HPC community has been gravitating towards ever more FLOPS, at the expense of many other subsystems. To draw attention to overall system balance, in this paper, we analyze balance ratios and architectural trends in the world's most powerful supercomputers. Specifically, we have collected performance characteristics of systems between1993 and 2018 based on the Top500 lists, and then analyzed their architectures from diverse system design perspectives. Notably, our analysis studies the performance balance of the machines, across a variety of subsystems such as compute, memory, I/O, interconnect, intra-node connectivity and power. Our analysis reveals that balance ratios of the various subsystems need to be considered carefully alongside the application workload portfolio to provision the subsystem capacity and bandwidth specifications, which can help achieve optimal performance.

97 MATHEMATICS AND COMPUTING↗

Integrating Renewable Energy into the Transmission and Distribution System of the U. S. Virgin Islands

This report focuses on the economic and technical feasibility of integrating renewable energy technologies into the U.S. Virgin Islands transmission and distribution systems. The report includes three main areas of analysis: 1) the economics of deploying utility-scale renewable energy technologies on St. Thomas/St. John and St. Croix; 2) potential sites for installing roof- and ground-mount PVsystems and wind turbines and the impact renewable generation will have on the electrical subtransmission and distribution infrastructure, and 3) the feasibility of a 100- to 200-megawatt power interconnection of the Puerto Rico Electric Power Authority (PREPA), Virgin Islands Water and Power Authority (WAPA), and British Virgin Islands (BVI) grids via a submarine cable system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Alternative Approaches for Incentivizing the Frequency Responsive Reserve Ancillary Service

Frequency responsive reserve is the autonomous response of generators and demand response to deviations of system frequency, usually as a result of the instantaneous outage of a large supplier. Frequency responsive reserve arrests the frequency decline resulting in the stabilization of system frequency, and avoids the triggering of under-frequency load-shedding or the reaching of unstablefrequencies that could ultimately lead to system blackouts. It is a crucial service required to maintain a reliable and secure power system. Regions with restructured electricity markets have historically had a lack of incentives for frequency responsive reserve because generators inherently provided the response and on large interconnected systems, more than sufficient response has beenavailable. This may not be the case in future systems due to new technologies and declining response. This paper discusses the issues that can occur without proper incentives and even disincentives, and proposes alternatives to introduce incentives for resources to provide frequency responsive reserve to ensure an efficient and reliable power system.

17 WIND ENERGY↗

An Analysis of System Balance and Architectural Trends Based on Top500 Supercomputers

Supercomputer design is a complex, multi-dimensional optimization process, wherein several subsystems need to be reconciled to meet a desired figure of merit performance for a portfolio of applications and a budget constraint. However, overall, the HPC community has been gravitating towards ever more Flops, at the expense of many other subsystems. To draw attention to overall system balance, in this paper, we analyze balance ratios and architectural trends in the world’s most powerful supercomputers. Specifically, we have collected the performance characteristics of systems between 1993 and 2019 based on the Top500 lists and then analyzed their architectures from diverse system design perspectives. Notably, our analysis studies the performance balance of the machines, across a variety of subsystems such as compute, memory, I/O, interconnect, intra-node connectivity and power. Our analysis reveals that balance ratios of the various subsystems need to be considered carefully alongside the application workload portfolio to provision the subsystem capacity and bandwidth specifications, which can help achieve optimal performance.

Khan, Awais↗

Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

This paper introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. In conclusion, the architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.

42 ENGINEERING↗

Transitioning to Hybrid Power Plants

Hybrid power plants are power generation systems that combine two or more types of electricity generation or storage, creating systems where the optimal dispatch provides more benefits that the sum of the individual components can. These plants exemplify the interconnected challenges of grid modernization. On one hand, rapid increase in deployment and enhanced controllability of renewable energy assets is needed to meet clean energy targets, but on the other, increasing electrification makes it more difficult to manage load and growth in the number of endpoints and stakeholders involved with hybrid plants complicates asset management and cybersecurity. This talk will cover trends in hybrid power plant technologies and deployments, identify future prospects for hybrid systems, and discuss the challenges and research opportunities that exist to transition from the traditional power grids of today to smart, distributed, hybrid power grids we may see in the next few decades.

14 SOLAR ENERGY↗

Interconnection Standard Grid-Support Function Evaluations Using an Automated Hardware-in-the-Loop Testbed

Grid operators are increasingly turning to advanced grid-support functions in distributed energy resources (DER) to assist with distribution circuit voltage regulation, bulk system frequency control, and power system protection. The U.S. DER certification standard, Underwriters Laboratories (UL) 1741, was revised in September 2016 to add test procedures for multiple grid-support functions. Sandia National Laboratories, SunSpec Alliance, and growing community of collaborators have undertaken a multiyear effort to create an open-source system validation platform (SVP) that automates DER interconnection and interoperability test procedures by communicating with grid simulators, photovoltaic (PV) simulators, data acquisition systems, and interoperable equipment under test. However, the power hardware required for generating the test conditions may be untenable for many organizations. In this paper, we discuss development of the SVP testing capabilities for UL 1741 tests utilizing a controller hardware-in-the-loop testbed that precludes the need for power hardware using a 34.5 kW Austrian Institute of Technology smart grid controller. Finally, analysis of normal ramp rate, soft start ramp rate, specified power factor, volt-VAr, and frequency-watt advanced grid functions, and the effectiveness of the UL 1741 test protocols are included.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Western Wind and Solar Integration Study Phase 3A: Low Levels of Synchronous Generation

The stability of the North American electric power grids under conditions of high penetrations of wind and solar is a significant concern and possible impediment to reaching renewable energy goals. The 33% wind and solar annual energy penetration considered in this study results in substantial changes to the characteristics of the bulk power system. This includes different power flow patterns, different commitment and dispatch of existing synchronous generation, and different dynamic behavior from wind and solar generation. The Western Wind and Solar Integration Study (WWSIS), sponsored by the U.S. Department of Energy, is one of the largest regional solar and wind integration studies to date. In multiple phases, it has explored different aspects of the question: Can we integrate large amounts of wind and solar energy into the electric power system of the West? The work reported here focused on the impact of low levels of synchronous generation on the transient stability performance in one part of the region in which wind generation has displaced synchronous thermal generation under highly stressed, weak system conditions. It is essentially an extension of WWSIS-3. Transient stability, the ability of the power system to maintain synchronism among all elements following disturbances, is a major constraint on operations in many grids, including the western U.S. and Texas systems. These constraints primarily concern the performance of the large-scale bulk power system. But grid-wide stability concerns with high penetrations of wind and solar are still not thoroughly understood. This work focuses on 'traditional' fundamental frequency stability issues, such as maintaining synchronism, frequency, and voltage. The objectives of this study are to better understand the implications of low levels of synchronous generation and a weak grid on overall system performance by: 1) Investigating the Western Interconnection under conditions of both high renewable generation (e.g., wind and solar) and low synchronous generation (e.g., significant coal power plant decommitment or retirement); and 2) Analyzing both the large-scale stability of the Western Interconnection and regional stability issues driven by more geographically dispersed renewable generation interacting with a transmission grid that evolved with large, central station plants at key nodes. As noted above, the work reported here is an extension of the research performed in WWSIS-3.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digitalization in Electric Power Systems and Regulation: A Primer

This report defines grid digitalization, provides concrete examples, and assesses five elements of digital systems that have evolved over the past three decades relevant to the electric distribution system: (1) network interconnection, (2) interoperability, (3) modularity, (4) open source, and (5) automation. This report also discusses the benefits and challenges of digitalization and provides a set of actions regulators can take to support the transition and realize the benefits of the transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CRADA 376 Final Report Development of Protective Coatings for 1 kW Hot Zone

Pacific Northwest National Laboratory (PNNL) has extensive experience in the development, fabrication, and evaluation of surface treatments and protective coatings for metallic solid oxide fuel cell (SOFC) components. For example, modified (Mn,Co)3O4 spinel coatings and coating/metal interfaces have been shown to substantially improve oxidation resistance, electrical performance, and oxide scale adhesion of ferritic stainless steel interconnects in planar SOFC stacks. At the time of the establishment of this CRADA, Protonex Technology Corporation had been working in the field of SOFC development for over 12 years and had demonstrated more than 250 thermal cycles with a less than 15 minutes start time and more than 2000 hours of continuous operation on a 250W tubular solid oxide hot zone module as part of a program for the Office of the Secretary of Defense (OSD). An industrial version of the military system, denoted P200i, had been developed that was launched at the 2015 Fuel Cell Expo in Tokyo. Feedback during beta testing of this unit was very positive. However, Protonex recognized that to transition from military markets, the commercial system would require longer life time and higher power. Leveraging their novel thermal management strategy from the tubular hot zone that allowed for rapid and repeated thermal cycling, Protonex developed a planar 1kW module aimed at the industrial and commercial market. However, more robust interconnect coatings were needed to bring the system into the 1000+ hour life time requested by customers. Therefore, PNNL’s experience and technology were engaged to enable the 1kw system to transition from military applications to commercial and industrial applications. In this CRADA, PNNL teamed with Protonex to leverage PNNL’s expertise in protective coating techniques for solid oxide fuel cell (SOFC) applications. As the first step in the collaboration, protective spinel coatings were fabricated at PNNL onto ten AISI 440 stainless steel bus bars provided by Protonex. A precursor slurry containing spinel powder was applied to the steel surfaces via an ultrasonic spray process. The coated bars were then subjected to a reducing atmosphere heat treatment (i.e., heated to 850°C at 3°C/min in a hydrogen atmosphere and held at that temperature for five hours). Five of the bars were left in this reduced condition; the other five bars were subjected to an oxidizing heat treatment (i.e., heated to 1000°C at 3°C/min in air and held at that temperature for one hour). The bars were then sent to Protonex for testing. Subsequently, Protonex decided to discontinue their SOFC development activities, so they had no further interest in continuing the collaboration with PNNL, and the CRADA activities were terminated.

30 DIRECT ENERGY CONVERSION↗

Energy Finite Element Analysis Developments for Vibration Analysis of Composite Aircraft Structures

The Energy Finite Element Analysis (EFEA) has been utilized successfully for modeling complex structural-acoustic systems with isotropic structural material properties. In this paper, a formulation for modeling structures made out of composite materials is presented. An approach based on spectral finite element analysis is utilized first for developing the equivalent material properties for the composite material. These equivalent properties are employed in the EFEA governing differential equations for representing the composite materials and deriving the element level matrices. The power transmission characteristics at connections between members made out of non-isotropic composite material are considered for deriving suitable power transmission coefficients at junctions of interconnected members. These coefficients are utilized for computing the joint matrix that is needed to assemble the global system of EFEA equations. The global system of EFEA equations is solved numerically and the vibration levels within the entire system can be computed. The new EFEA formulation for modeling composite laminate structures is validated through comparison to test data collected from a representative composite aircraft fuselage that is made out of a composite outer shell and composite frames and stiffeners. NASA Langley constructed the composite cylinder and conducted the test measurements utilized in this work.

Vlahopoulos, Nickolas↗