Search NASA⌕ Search

SEARCH · Search NASA

Results for “Illumination condition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Multi-Electron Transfer at H-Terminated p-Si Electrolyte Interfaces: Large Photovoltages under Inversion Conditions

Here, photovoltages for hydrogen terminated p-Si(111) in an acetonitrile electrolyte were quantified with methyl viologen [1,1'-(CH 3 ) 2 -4,4'-bipyridinium](PF 6 ) 2 , abbreviated MV 2+ , and [Ru(bpy) 3 ](PF 6 ) 2 , where bpy is 2,2'-bipyridine, that respectively undergo two and three one-electron transfer reductions. The reduction potentials, E°, of the two MV 2+ reductions occurred at energies within the forbidden bandgap, while the three [Ru(bpy) 3 ] 2+ reductions occurred within the continuum of conduction band states. Bandgap illumination resulted in reduction that were more positive than that measured with a degenerately doped n + -Si demonstrative of a photovoltage, Vph, that increased in the order: MV 2+/+ (260 mV) < MV +/0 (400 mV) < Ru 2+/+ (530 mV) ~ Ru +/0 (540 mV) ~ Ru 0/– (550 mV). Pulsed 532 nm excitation generated electron-hole pairs whose dynamics were nearly constant under depletion conditions and increased markedly as the potential was raised or lowered. A long wavelength absorption feature assigned to conduction band electrons provided additional evidence for the presence of an inversion layer. Collectively, the data reveal that the most optimal photovoltage, as well at the longest electron-hole pair lifetime and the highest surface electron concentration, occur when E° lies energetically within the unfilled conduction band states where an inversion layer is present. The bell-shaped dependence for electron-hole pair recombination with the surface potential was predicted by the time-honored SRH model providing a clear indication that this interface provides access to all four bias conditions, i.e., accumulation, flat band, depletion, and inversion. The implications of these findings for photocatalysis applications and solar energy conversion are discussed.

14 SOLAR ENERGY↗

Dual-Image Color Normalization to Enable High-Performance Concentrating Solar Optical Metrology

Concentrating Solar Power (CSP) requires precision mirrors, and these in turn require metrology systems to measure their optical slope. In this project we studied a color-based approach to the correspondence problem, which is the association of points on an optical target with their corresponding points seen in a reflection. This is a core problem in deflectometry-based metrology, and a color solution would enable important new capabilities. We modeled color as a vector in the [R,G,B] space measured by a digital camera, and explored a dual-image approach to compensate for inevitable changes in illumination color. Through a series of experiments including color target design and dual-image setups both indoors and outdoors, we collected reference/measurement image pairs for a variety of configurations and light conditions. We then analyzed the resulting image pairs by selecting example [R,G,B] pixels in the reference image, and seeking matching [R,G,B] pixels in the measurement image. Modulating a tolerance threshold enabled us to assess both match reliability and match ambiguity, and for some configurations, orthorectification enabled us to assess match accuracy. Using direct-direct imaging, we demonstrated color correspondence achieving average match accuracy values of 0.004 h, where h is the height of the color pattern. We found that wide-area two-dimensional and linear one-dimensional color targets outperformed hybrid linear/lateral gradient targets in the cases studied. Introducing a mirror degraded performance under our current techniques, and we did not have time to evaluate whether matches could be reliably achieved despite varying light conditions. Nonetheless, our results thus far are promising.

14 SOLAR ENERGY↗

The spectral bidirectional reflectance of snow

A radiative transfer model for the bidirectional reflectance-distribution function (BRDF) shows that snow is moderately anisotropic in the near-infrared wavelengths. Although the directional-hemispherical albedo of snow decreases as the grains become larger, the forward scattering also increases, with the result that the illumination and viewing geometry must be considered when interpreting physical properties of the surface layer of the snow pack from remote sensing data. Measurements of the BRDF for a variety of snow conditions were made throughout the winter and spring seasons with a spectroradiometer, for wavelengths from 0.38 to 1.11 microns. Coincident with these the surface grain properties were analyzed by stereological methods. The data show that Mie scattering calculations using an equivalent spherical radius match the directional-hemispherical reflectance, but the BRDF usually shows a small peak in the backscattered direction that would not occur from spherical grains. The sphere with the same surface-to-volume ratio as the ice grains is used as the equivalent sphere.

Dozier, J.↗

Night Vision Camera

PixelVision, Inc. developed the Night Video NV652 Back-illuminated CCD Camera, based on the expertise of a former Jet Propulsion Laboratory employee and a former employee of Scientific Imaging Technologies, Inc. The camera operates without an image intensifier, using back-illuminated and thinned CCD technology to achieve extremely low light level imaging performance. The advantages of PixelVision's system over conventional cameras include greater resolution and better target identification under low light conditions, lower cost and a longer lifetime. It is used commercially for research and aviation.

Source record↗

Human performance capabilities in a simulated space station-like environment. 1: Fixed beam luminance and location

The effects of a fixed, intense, one-foot diameter beam of simulated sunlight imaged within the field of view, upon responses to a battery of visual, body balance and stability, eye-hand coordination, and mental tests were studied. Each subject's electrocardiogram and electro-oculograms (vertical and horizontal) were recorded throughout each two-hour testing period within the space-station-like environment. It is possible to say that both subjects adapted to the brightly illuminated white panels in approximately 30 seconds after their first exposure each day and thereafter did not experience ocular fatigue, eye strain, or other kinds of disturbances as a result of these viewing conditions.

Haines, R. F.↗

First results from a laboratory facility for measurement of emission spectra under simulated planetary conditions

We have developed a laboratory spectroscopic facility for the measurement of emission spectra under simulated planetary conditions. Spectral measurements are made from 6 to 13 microns with a scanning grating monochromator equipped with a HgCdTl detector. An environment chamber in service in Hawaii for several years in which we can control the temperature from 77 K to 500 K, the pressure from 10(exp -5) torr to two atmospheres, has been equipped with a 77 K or 273 K cold shield. The shield serves to minimize light reflected off the sample and to aid in development of thermal gradients for obtaining spectra under conditions simulating the thermal environment of airless bodies. Samples are placed in small cups on a temperature controlled substrate allowing measurements of emission due to heating from below by the substrate, or from illumination from a solar simulation source.

Lucey, Paul G.↗

The Inter-Calibration of the DSCOVR EPIC Imager 2 with Aqua-MODIS and NPP-VIIRS

The Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) continuously observes the illuminated disk from the Lagrange-1 point. The EPIC sensor was designed to monitor the diurnal variation of ozone, clouds, aerosols, and vegetation, especially those features that benefit from observation near-backscatter conditions. The EPIC sensor does not contain any onboard calibration systems. This study describes the inter-calibration of EPIC channels 5 (0.44 μm), 6 (0.55 μm), 7 (0.68 μm), and 10 (0.78 μm) with respect to Aqua-MODIS and NPP-VIIRS. The calibration is transferred using coincident ray-matched reflectance pairs over all-sky tropical ocean (ATO) and deep convective cloud (DCC) targets. A robust and automated image-alignment technique based on feature matching was formulated to improve the navigation quality of the EPIC images. The EPIC V02 dataset exhibits improved navigation over V01. Because the visible channels display similar spatial features, a single visible channel can be used to co-register the remaining visible bands. The VIIRS-referenced EPIC ATO and DCC ray-matched calibration coefficients are within 0.3%. The EPIC four-year calibration trends based on VIIRS are within 0.15%/year. The MODIS-based EPIC calibration coefficients were compared against the Geogdzhayev and Marshak 2018 published calibration coefficients and are found to be within 1.6%.

DSCOVR↗

Effects of Radiation-Induced Defects on Corrosion

The next generation of nuclear reactors will expose materials to conditions that, in some cases, are even more extreme than those in current fission reactors, inevitably leading to new materials science challenges. Radiation-induced damage and corrosion are two key phenomena that must be understood both independently and synergistically, but their interactions are often convoluted. In the light water reactor community, a tremendous amount of work has been done to illuminate irradiation-corrosion effects, and similar efforts are under way for heavy liquid metal and molten salt environments. While certain effects, such as radiolysis and irradiation-assisted stress corrosion cracking, are reasonably well established, the basic science of how irradiation-induced defects in the base material and the corrosion layer influence the corrosion process still presents many unanswered questions. In this review, we summarize the work that has been done to understand these coupled extremes, highlight the complex nature of this problem, and identify key knowledge gaps.

36 MATERIALS SCIENCE↗

Video-rate Raman-based metabolic imaging by Airy light-sheet illumination and photon-sparse detection

Despite its massive potential, Raman imaging represents just a modest fraction of all research and clinical microscopy to date. This is due to the ultralow Raman scattering cross-sections of most biomolecules that impose low-light or photon-sparse conditions. Bioimaging under such conditions is suboptimal, as it either results in ultralow frame rates or requires increased levels of irradiance. Here, we overcome this tradeoff by introducing Raman imaging that operates at both video rates and 1,000-fold lower irradiance than state-of-the-art methods. To accomplish this, we deployed a judicially designed Airy light-sheet microscope to efficiently image large specimen regions. Further, we implemented subphoton per pixel image acquisition and reconstruction to confront issues arising from photon sparsity at just millisecond integrations. We demonstrate the versatility of our approach by imaging a variety of samples, including the three-dimensional (3D) metabolic activity of single microbial cells and the underlying cell-to-cell variability. To image such small-scale targets, we again harnessed photon sparsity to increase magnification without a field-of-view penalty, thus, overcoming another key limitation in modern light-sheet microscopy.

60 APPLIED LIFE SCIENCES↗

Extended use of face masks during the COVID-19 pandemic - Thermal conditioning and spray-on surface disinfection

The current COVID-19 pandemic has resulted in globally constrained supplies for face masks and personal protective equipment (PPE). Production capacity is limited in many countries and the future course of the pandemic will likely continue with shortages for high quality masks and PPE in the foreseeable future. Therefore, expectations are that mask reuse, extended wear and similar approaches will enhance the availability of personal protective measures. Repeated thermal disinfection could be an important option and likely easier implemented in some situations, at least on the small scale, than UV illumination, irradiation or hydrogen peroxide vapor exposure. In this paper, an overview on thermal responses and ongoing filtration performance of multiple face mask types is provided. Most masks have adequate material properties to survive a few cycles (i.e. 30 min disinfection steps) of thermal exposure in the 75°C regime. Some are more easily affected, as seen by the fusing of plastic liner or warping, given that preferred conditioning temperatures are near the softening point for some of the plastics and fibers used in these masks. Hence adequate temperature control is equally important. As guidance, disinfectants sprayed via dilute solutions maintain a surface presence over extended time at 25 and 37°C. Some spray-on alcohol-based solutions containing disinfectants were gently applied to the top surface of masks. Neither moderate thermal aging (less than 24 h at 80 and 95°C) nor gentle application of surface disinfectant sprays resulted in measurable loss of mask filter performance. Subject to bio-medical concurrence (additional checks for virus kill efficiency) and the use of low risk non-toxic disinfectants, such strategies, either individually or combined, by offering additional anti-viral properties or short term refreshing, may complement reuse options of professional masks or the now ubiquitous custom-made face masks with their often unknown filtration effectiveness.

36 MATERIALS SCIENCE↗

Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO 2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Atmospheric Exposure Triggers Light-Induced Degradation in 2D Lead-Halide Perovskites

Quasi-2D perovskites have been pivotal in recent efforts to stabilize perovskite solar cells. Despite the stability boost provided when these materials are introduced in perovskite solar cells, little is known about the intrinsic light and environmental stability of quasi-2D perovskites. In this study, we characterize the photostability of exfoliated quasi-2D perovskite single crystals in air using photoluminescence, infrared, X-ray fluorescence, and energydispersive X-ray spectroscopy. Photoexcitation leads to severe material loss with oxygen as a prerequisite for material breakdown. The effect can be traced to the formation of reactive oxygen species, as demonstrated by increases in the photostability under oxygen-free conditions. We show the effect of combined passivation steps, showcasing the stability enhancement offered by 2D-capping layers in combination with an oxygen-free atmosphere. Our results reveal that the stability of illuminated quasi-2D perovskites depends critically on oxygen exposure, highlighting the importance of oxygen-blocking passivation strategies for stable 2D perovskite-based devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Droplet field visualization and characterization via digital image analysis

This paper describes techniques that have been developed at JPL for visualization and measurements of droplet fields in a moving airstream. The techniques have been applied to a variety of problems which include simulation of heavy rain conditions in a wind tunnel, engine ingestion of wheel spray, analysis of fuel nozzle sprays and aerodynamic breakup of non-Newtonian liquids. The approach pursued here is direct imaging using a pulsed laser illumination source, followed by digital processing of photographic images. A laser double pulse technique has been used for determination of droplet velocities. Laser induced fluorescence has been used to enhance droplet definition in photographic images. The image processing software developed is capable of distinguishing between out-of-focus and in-focus drops, retaining only the latter for size determination.

Hernan, M. A.↗

Hyperspectral Thermal Fabry-Perot Modeling

Fabry-Perot interferometer are simple elegant, tunable filters that can be used to make compact hyperspectral thermal imaging system. To foster the development of these sensors, software tools for the design and simulation of tunable Fabry-Perot infrared imagers have been developed. The tools are provided at three levels: basic, design, and system. Basic tools describe a nearly ideal Fabry-Perot filter with perfectly flat and parallel mirrors in collimated space. Design tools that take into account non-ideal behavior such as mirror and collimation defects calculate free spectral range, finesse, and spectral width of the interferometer. System tools help analyze an integration of the Fabry-Perot filter into a camera system. They include spectral convolution, first-order optical layout, and an estimation of signal-to-noise ratio. The complete set of tools allows for simulations of system operation and performance with various illumination sources. Spectral images generated in such simulations were used to examine applicability of Fabry-Perot system in remote sensing of atmospheric gases including detection of environmental pollutants and hazardous gases. Different operating conditions and system configurations are presented.

Ryan, Robert↗

Reflectance and transmittance of snow at high spectral resolution

A radiative-transfer model for the bidirectional reflectance-distribution function (BRDF) shows that snow is moderately anisotropic in the NIR wavelengths. Although the directional-hemispherical albedo of snow decreases as the grains become larger, the forward scattering also increases, with the result that the illumination and viewing geometry must be considered when interpreting physical properties of the surface layer of the snow pack from remote sensing data. Measurements of the BRDF and the transmittance for a variety of snow conditions were made throughout the winter and spring seasons with an SE-590 spectroradiometer, for wavelengths from 0.38 to 1.11 microns. Coincident with these, the surface grain properties were analyzed by stereological methods. A sphere with the same surface-to-volume ratio as the ice grains is used as the equivalent sphere.

Dozier, Jeff↗

Blocking Losses on an Optical Communications Link

Many photon-counting photo-detectors have the property that they become inoperative for some time after detection event. We say the detector is blocked during this time.Blocking produces losses when using the detector as a photon-counter to detect a communications signal. In this paper, we characterize blocking losses for single detectors and for arrays of detectors. For arrays, we discuss conditions under which the output may be approximated as a Poisson point process, and provide a simple approximation to the blocking loss. We show how to extend the analysis to arrays of non-uniformly illuminated arrays.

blocked detectors↗

Connecting Energy Input With Ionospheric Upflow and Outflow

The connection between energy inputs and the generation of ion upflows and outflows is a topic of keen scientific interest and the subject of a number of empirical studies. Despite this interest, it remains uncertain how different ion species respond to energy input, what defines the upper and lower bounds of the ion flux, and what role solar illumination plays in regulating the relationship between energy input and ion upflows/outflows. This work simulates how ion flux scales with low and high altitude energization, and to a combination of both. Furthermore, we examine the influence of solar illumination on these relationships by considering how the scaling of ion flux with energy input changes over the solar cycle, comparing solar minimum and maximum, as well as how they change from day to night conditions. We find O -+ flux tends to respond more strongly to energy inputs than H -+ flux, with the O -+ flux often exhibiting a lower activation energy and a greater dynamic range. The lower bound of the ion flux at 4,000 km is typically defined by the polar wind H -+ , although O -+ upflows can dominate at low altitudes in the presence of significant frictional heating of the ion gas or soft electron precipitation. However, when significant soft electron precipitation and wave-particle interactions are present simultaneously the lower bound of the ion flux at 4,000 km is defined by the O -+ . Finally, we find a difference between the steady state response of the outflow to energy input and the peak response.

A. Glocer↗

Overview of the MISSE-16 Mission and Preliminary Characterization of Novel Space Weathered Materials

The Materials International Space Station Experiment (MISSE) project is a series of experiments that began in 2001, involving the deployment of external experiment platforms on the International Space Station (ISS). Since then, more than 4,000 materials were tested yielding valuable data and insights into the performance of materials and coatings in the harsh space environment, as well as providing a platform for testing and validating new materials and technologies. The results of the MISSE experiments have contributed to the development of more durable and reliable spacecraft and equipment, as well as improving our understanding of the space environment and its effects on human space exploration. To gain deeper insights into the changes in material properties of both novel and heritage spacecraft materials over the course of a mission, we proposed to enhance the MISSE hardware. This was achieved by integrating a high-resolution camera that can capture both RGB and IR color data, along with an updated illumination scheme. The identical sets of selected materials were mounted on the Zenith, Ram, and Wake faces of the ISS to expose them to predominant vacuum ultraviolet (VUV), atomic oxygen, and high-energy electron conditions. In addition, we exposed flight duplicates of these materials to a simulated space environment, which included sequential exposure to the same irradiation species on the ground. This allowed us to study the effects of space exposure on the materials in a controlled manner and to compare their behavior in both real and simulated space environments. The MISSE-FF flight sample collection comprised different classes of polymers, including polyimides from the Kapton family, manufactured by E.I du Pont de Nemours and Co., Polyethylene terephthalate (PET) materials, liquid crystal polymers, PI/Polyhedral Oligomeric Silsesquioxanes (POSS), and carbon and glass fiber reinforced polymers. The experimental cadence during the MISSE-16 mission (~6 months) included daily images of each sample for the first week, weekly for the next 2 months, and monthly the remaining duration of the mission. This paper will focus on the flight duplicate as well as the postflight optical characterization of novel and heritage materials currently under observation on the MISSE-FF.

Jainisha R Shah↗