Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Pore system characterization of organic-rich shales using nanoscale-resolution 3D imaging

The Vaca Muerta Shale in Argentina is the first signifcant commercial shale oil/gas play outside of North America. High-resolution 2D/3D imaging of shale rocks for the purpose of establishing their mineralogy, total, and connected porosities has become more and more sophisticated. In this paper, nanoscale-resolution focused ion beam (FIB)-scanning electron microscopy (SEM) nano-tomography was used to obtain images of pore structures within two organic-rich regions of interest (ROIs), selected based on correlative SEM and automated mineralogy maps. Advanced machine learning classification tools were used to segment the images and assign porosities and other components. Pore size distribution and pore connectivity analyzes revealed that about 95% of all the pores, present within the two ROIs, had a diameter of less than approximately 75 nm, and that most of these pores were poorly connected. In a similar fashion, the flow rate distribution analysis showed that pores with diameters of about 150-330 nm contributed to over 50% of the flow capacity of the connected pore systems. These results suggest that although most of the pores typically found in shales have pore diameter smaller than about 100 nm, most of the hydrocarbon production may be carried by a relatively small number of larger connected pores with pore diameter greater than about 150 nm. This research implies that a large portion of the organic-hosted pores (with diameter typically smaller than about 100 nm) may not provide permeable flow pathways for the oil and/or gas migration, and hence may have very little contribution to the hydrocarbon production.

58 GEOSCIENCES↗

Sci-Thur AM: YIS – 03: Combining sagittally-reconstructed 3D and live-2D ultrasound for high-dose-rate prostate brachytherapy needle segmentation

Ultrasound-guided high-dose-rate prostate brachytherapy (HDR-BT) needle segmentation is performed clinically using live-2D sagittal images. Organ segmentation is then performed using axial images, introducing a source of geometric uncertainty. Sagittally-reconstructed 3D (SR3D) ultrasound enables both needle and organ segmentation, but suffers from shadow artifacts. We present a needle segmentation technique augmenting SR3D with live-2D sagittal images using mechanical probe tracking to mitigate image artifacts and compare it to the clinical standard. Seven prostate cancer patients underwent TRUS-guided HDR-BT during which the clinical and proposed segmentation techniques were completed in parallel using dual ultrasound video outputs. Calibrated needle end-length measurements were used to calculate insertion depth errors (IDEs), and the dosimetric impact of IDEs was evaluated by perturbing clinical treatment plan source positions. The proposed technique provided smaller IDEs than the clinical approach, with mean±SD of −0.3±2.2 mm and −0.5±3.7mm respectively. The proposed and clinical techniques resulted in 84% and 43% of needles with IDEs within ±3mm, and IDE ranges across all needles of [−7.7mm, 5.9mm] and [−9.3mm, 7.7mm] respectively. The proposed and clinical IDEs lead to mean±SD changes in the volume of the prostate receiving the prescription dose of −0.6±0.9% and −2.0±5.3% respectively. The proposed technique provides improved HDR-BT needle segmentation accuracy over the clinical technique leading to decreased dosimetric uncertainty by eliminating the axial-to-sagittal registration, and mitigates the effect of shadow artifacts by incorporating mechanically registered live-2D sagittal images.

60 APPLIED LIFE SCIENCES↗

Simultaneous hierarchical segmentation and vectorization of satellite images through combined data sampling and anisotropic triangulation

The automatic detection, recognition , and segmentation of object classes in remote sensed images is of crucial importance for scene interpretation and understanding. However, it is a difficult task because of the high variability of satellite data. Indeed, the observed scenes usually exhibit a high degree of complexity, where complexity refers to the large variety of pictorial representations of objects with the same semantic meaning and also to the extensive amount of available det.ails. Therefore, there is still a strong demand for robust techniques for automatic information extraction and interpretation of satellite images. In parallel, there is a growing interest in techniques that can extract vector features directly from such imagery. In this paper, we investigate the problem of automatic hierarchical segmentation and vectorization of multispectral satellite images. We propose a new algorithm composed of the following steps: (i) a non-uniform sampling scheme extracting most salient pixels in the image, (ii) an anisotropic triangulation constrained by the sampled pixels taking into account both strength and directionality of local structures present in the image, (iii) a polygonal grouping scheme merging, through techniques based on perceptual information , the obtained segments to a smaller quantity of superior vectorial objects. Besides its computational efficiency, this approach provides a meaningful polygonal representation for subsequent image analysis and/or interpretation.

47 OTHER INSTRUMENTATION↗

Influence of cold walls on PET image quantification and volume segmentation: A phantom study

Purpose: Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These “cold” walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in errors in the estimation of standardized uptake values. Numerous papers suggest that this is an issue for phantom work simulating tumor tissue, quality control, and calibration work. This study aims to investigate the influence of the cold plastic wall thickness on the quantification of 18F-fluorodeoxyglucose on the image activity recovery and on the performance of advanced automatic segmentation algorithms for the delineation of active regions delimited by plastic walls.Methods: A commercial set of six spheres of different diameters was replicated using a manufacturing technique which achieves a reduction in plastic walls thickness of up to 90%, while keeping the same internal volume. Both sets of thin- and thick-wall inserts were imaged simultaneously in a custom phantom for six different tumor-to-background ratios. Intensity values were compared in terms of mean and maximum standardized uptake values (SUVs) in the spheres and mean SUV of the hottest 1 ml region (SUV{sub max}, SUV{sub mean}, and SUV{sub peak}). The recovery coefficient (RC) was also derived for each sphere. The results were compared against the values predicted by a theoretical model of the PET-intensity profiles for the same tumor-to-background ratios (TBRs), sphere sizes, and wall thicknesses. In addition, ten automatic segmentation methods, written in house, were applied to both thin- and thick-wall inserts. The contours obtained were compared to computed tomography derived gold standard (“ground truth”), using five different accuracy metrics.Results: The authors' results showed that thin-wall inserts achieved significantly higher SUV{sub mean}, SUV{sub max}, and RC values (up to 25%, 16%, and 25% higher, respectively) compared to thick-wall inserts, which was in agreement with the theory. This effect decreased with increasing sphere size and TBR, and resulted in substantial (>5%) differences between thin- and thick-wall inserts for spheres up to 30 mm diameter and TBR up to 4. Thinner plastic walls were also shown to significantly improve the delineation accuracy for the majority of the segmentation methods tested, by increasing the proportion of lesion voxels detected, although the errors in image quantification remained non-negligible.Conclusions: This study quantified the significant effect of a 90% reduction in the thickness of insert walls on SUV quantification and PET-based boundary detection. Mean SUVs inside the inserts and recovery coefficients were particularly affected by the presence of thick cold walls, as predicted by a theoretical approach. The accuracy of some delineation algorithms was also significantly improved by the introduction of thin wall inserts instead of thick wall inserts. This study demonstrates the risk of errors deriving from the use of cold wall inserts to assess and compare the performance of PET segmentation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-I-11: Software Development for 4D-CBCT Research of Real-Time-Image Gated Spot Scanning Proton Therapy

Purpose: To acquire correct information for inside the body in patient positioning of Real-time-image Gated spot scanning Proton Therapy (RGPT), utilization of tomographic image at exhale phase of patient respiration obtained from 4-dimensional Cone beam CT (4D-CBCT) has been desired. We developed software named “Image Analysis Platform” for 4D-CBCT researches which has technique to segment projection-images based on 3D marker position in the body. The 3D marker position can be obtained by using two axes CBCT system at Hokkaido University Hospital Proton Therapy Center. Performance verification of the software was implemented. Methods: The software calculates 3D marker position retrospectively by using matching positions on pair projection-images obtained by two axes fluoroscopy mode of CBCT system. Log data of 3D marker tracking are outputted after the tracking. By linking the Log data and gantry-angle file of projection-image, all projection-images are equally segmented to spatial five-phases according to marker 3D position of SI direction and saved to specified phase folder. Segmented projection-images are used for CBCT reconstruction of each phase. As performance verification of the software, test of segmented projection-images was implemented for sample CT phantom (Catphan) image acquired by two axes fluoroscopy mode of CBCT. Dummy marker was added on the images. Motion of the marker was modeled to move in 3D space. Motion type of marker is sin4 wave function has amplitude 10.0 mm/5.0 mm/0 mm, cycle 4 s/4 s/0 s for SI/AP/RL direction. Results: The marker was tracked within 0.58 mm accuracy in 3D for all images, and it was confirmed that all projection-images were segmented and saved to each phase folder correctly. Conclusion: We developed software for 4D-CBCT research which can segment projection-image based on 3D marker position. It will be helpful to create high quality of 4D-CBCT reconstruction image for RGPT.

60 APPLIED LIFE SCIENCES↗

MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

60 APPLIED LIFE SCIENCES↗

Compressing TV-image data

Compressing technique calculates activity estimator for each segment of image line. Estimator is used in conjunction with allowable bits per line, N, to determine number of bits necessary to code each segment and which segments can tolerate truncation. Preprocessed line data are then passed to adaptive variable-length coder, which selects optimum transmission code. Method increases capacity of broadcast and cable television transmissions and helps reduce size of storage medium for video and digital audio recordings.

Hilbert, E. E.↗

Development of computational small animal models and their applications in preclinical imaging and therapy research

The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Flexible Method for Producing F.E.M. Analysis of Bone Using Open-Source Software

This project, performed in support of the NASA GRC Space Academy summer program, sought to develop an open-source workflow methodology that segmented medical image data, created a 3D model from the segmented data, and prepared the model for finite-element analysis. In an initial step, a technological survey evaluated the performance of various existing open-source software that claim to perform these tasks. However, the survey concluded that no single software exhibited the wide array of functionality required for the potential NASA application in the area of bone, muscle and bio fluidic studies. As a result, development of a series of Python scripts provided the bridging mechanism to address the shortcomings of the available open source tools. The implementation of the VTK library provided the most quick and effective means of segmenting regions of interest from the medical images; it allowed for the export of a 3D model by using the marching cubes algorithm to build a surface mesh. To facilitate the development of the model domain from this extracted information required a surface mesh to be processed in the open-source software packages Blender and Gmsh. The Preview program of the FEBio suite proved to be sufficient for volume filling the model with an unstructured mesh and preparing boundaries specifications for finite element analysis. To fully allow FEM modeling, an in house developed Python script allowed assignment of material properties on an element by element basis by performing a weighted interpolation of voxel intensity of the parent medical image correlated to published information of image intensity to material properties, such as ash density. A graphical user interface combined the Python scripts and other software into a user friendly interface. The work using Python scripts provides a potential alternative to expensive commercial software and inadequate, limited open-source freeware programs for the creation of 3D computational models. More work will be needed to validate this approach in creating finite-element models.

gravitational physiology↗

Power spectral ensity of markov texture fields

Texture is an important image characteristic. A variety of spatial domain techniques were proposed for extracting and utilizing textural features for segmenting and classifying images. for the most part, these spatial domain techniques are ad hos in nature. A markov random field model for image texture is discussed. A frequency domain description of image texture is derived in terms of the power spectral density. This model is used for designing optimum frequency domain filters for enhancing, restoring and segmenting images based on their textural properties.

Shanmugan, K. S.↗

Statistical characterization of experimental magnetized liner inertial fusion stagnation images using deep-learning-based fuel–background segmentation

Significant variety is observed in spherical crystal x-ray imager (SCXI) data for the stagnated fuel–liner system created in Magnetized Liner Inertial Fusion (MagLIF) experiments conducted at the Sandia National Laboratories Z-facility. As a result, image analysis tasks involving, e.g., region-of-interest selection (i.e. segmentation), background subtraction and image registration have generally required tedious manual treatment leading to increased risk of irreproducibility, lack of uncertainty quantification and smaller-scale studies using only a fraction of available data. We present a convolutional neural network (CNN)-based pipeline to automate much of the image processing workflow. This tool enabled batch preprocessing of an ensemble of N scans = 139 SCXI images across N exp = 67 different experiments for subsequent study. The pipeline begins by segmenting images into the stagnated fuel and background using a CNN trained on synthetic images generated from a geometric model of a physical three-dimensional plasma. The resulting segmentation allows for a rules-based registration. Our approach flexibly handles rarely occurring artifacts through minimal user input and avoids the need for extensive hand labelling and augmentation of our experimental dataset that would be needed to train an end-to-end pipeline. Here we also fit background pixels using low-degree polynomials, and perform a statistical assessment of the background and noise properties over the entire image database. Our results provide a guide for choices made in statistical inference models using stagnation image data and can be applied in the generation of synthetic datasets with realistic choices of noise statistics and background models used for machine learning tasks in MagLIF data analysis. We anticipate that the method may be readily extended to automate other MagLIF stagnation imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-contrast imaging with an arbitrary aperture: Active compensation of aperture discontinuities

We present a new method to achieve high-contrast images using segmented and/or on-axis telescopes. Our approach relies on using two sequential deformable mirrors (DMs) to compensate for the large amplitude excursions in the telescope aperture due to secondary support structures and/or segment gaps. In this configuration the parameter landscape of DM surfaces that yield high-contrast point-spread functions is not linear, and nonlinear methods are needed to find the true minimum in the optimization topology. We solve the highly nonlinear Monge-Ampere equation that is the fundamental equation describing the physics of phase-induced amplitude modulation. We determine the optimum configuration for our two sequential DM system and show that high-throughput and high-contrast solutions can be achieved using realistic surface deformations that are accessible using existing technologies. We name this process Active Compensation of Aperture Discontinuities (ACAD). We show that for geometries similar to the James Webb Space Telescope, ACAD can attain at least 10{sup –7} in contrast and an order of magnitude higher for both the future extremely large telescopes and on-axis architectures reminiscent of the Hubble Space Telescope. We show that the converging nonlinear mappings resulting from our DM shapes actually damp near-field diffraction artifacts in the vicinity of the discontinuities. Thus, ACAD actually lowers the chromatic ringing due to diffraction by segment gaps and struts while not amplifying the diffraction at the aperture edges beyond the Fresnel regime. This outer Fresnel ringing can be mitigated by properly designing the optical system. Consequently, ACAD is a true broadband solution to the problem of high-contrast imaging with segmented and/or on-axis apertures. We finally show that once the nonlinear solution is found, fine tuning with linear methods used in wavefront control can be applied to further contrast by another order of magnitude. Generally speaking, the ACAD technique can be used to significantly improve a broad class of telescope designs for a variety of problems.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting Mechanical Properties from Microstructure Images in Fiber-Reinforced Polymers Using Convolutional Neural Networks

Evaluating the mechanical response of fiber-reinforced composites can be extremely time-consuming and expensive. Machine learning (ML) techniques offer a means for faster predictions via models trained on existing input–output pairs and have exhibited success in composite research. This paper explores a fully convolutional neural network modified from StressNet, which was originally used for linear elastic materials, and extended here for a non-linear finite element (FE) simulation to predict the stress field in 2D slices of segmented tomography images of a fiber-reinforced polymer specimen. The network was trained and evaluated on data generated from the FE simulations of the exact microstructure. The testing results show that the trained network accurately captures the characteristics of the stress distribution, especially on fibers, solely from the segmented microstructure images. The trained model can make predictions within seconds in a single forward pass on an ordinary laptop, given the input microstructure, compared to 92.5 h to run the full FE simulation on a high-performance computing cluster. These results show promise in using ML techniques to conduct fast structural analysis for fiber-reinforced composites and suggest a corollary that the trained model can be used to identify the location of potential damage sites in fiber-reinforced polymers.

Sun, Yixuan (ORCID:0000000311093380)↗

TU-H-206-04: An Effective Homomorphic Unsharp Mask Filtering Method to Correct Intensity Inhomogeneity in Daily Treatment MR Images

Purpose: The daily treatment MRIs acquired on MR-IGRT systems, like diagnostic MRIs, suffer from intensity inhomogeneity issue, associated with B1 and B0 inhomogeneities. An improved homomorphic unsharp mask (HUM) filtering method, automatic and robust body segmentation, and imaging field-of-view (FOV) detection methods were developed to compute the multiplicative slow-varying correction field and correct the intensity inhomogeneity. The goal is to improve and normalize the voxel intensity so that the images could be processed more accurately by quantitative methods (e.g., segmentation and registration) that require consistent image voxel intensity values. Methods: HUM methods have been widely used for years. A body mask is required, otherwise the body surface in the corrected image would be incorrectly bright due to the sudden intensity transition at the body surface. In this study, we developed an improved HUM-based correction method that includes three main components: 1) Robust body segmentation on the normalized image gradient map, 2) Robust FOV detection (needed for body segmentation) using region growing and morphologic filters, and 3) An effective implementation of HUM using repeated Gaussian convolution. Results: The proposed method was successfully tested on patient images of common anatomical sites (H/N, lung, abdomen and pelvis). Initial qualitative comparisons showed that this improved HUM method outperformed three recently published algorithms (FCM, LEMS, MICO) in both computation speed (by 50+ times) and robustness (in intermediate to severe inhomogeneity situations). Currently implemented in MATLAB, it takes 20 to 25 seconds to process a 3D MRI volume. Conclusion: Compared to more sophisticated MRI inhomogeneity correction algorithms, the improved HUM method is simple and effective. The inhomogeneity correction, body mask, and FOV detection methods developed in this study would be useful as preprocessing tools for many MRI-related research and clinical applications in radiotherapy. Authors have received research grants from ViewRay and Varian.

60 APPLIED LIFE SCIENCES↗

Identification of uncommon objects in containers

A system for identifying in an image an object that is commonly found in a collection of images and for identifying a portion of an image that represents an object based on a consensus analysis of segmentations of the image. The system collects images of containers that contain objects for generating a collection of common objects within the containers. To process the images, the system generates a segmentation of each image. The image analysis system may also generate multiple segmentations for each image by introducing variations in the selection of voxels to be merged into a segment. The system then generates clusters of the segments based on similarity among the segments. Each cluster represents a common object found in the containers. Once the clustering is complete, the system may be used to identify common objects in images of new containers based on similarity between segments of images and the clusters.

97 MATHEMATICS AND COMPUTING↗

Identification of uncommon objects in containers

A system for identifying in an image an object that is commonly found in a collection of images and for identifying a portion of an image that represents an object based on a consensus analysis of segmentations of the image. The system collects images of containers that contain objects for generating a collection of common objects within the containers. To process the images, the system generates a segmentation of each image. The image analysis system may also generate multiple segmentations for each image by introducing variations in the selection of voxels to be merged into a segment. The system then generates clusters of the segments based on similarity among the segments. Each cluster represents a common object found in the containers. Once the clustering is complete, the system may be used to identify common objects in images of new containers based on similarity between segments of images and the clusters.

97 MATHEMATICS AND COMPUTING↗

Identification of breast contour for nipple segmentation in breast magnetic resonance images

Purpose: The purpose of this study is to develop a method to simulate the breast contour and segment the nipple in breast magnetic resonance images. Methods: This study first identifies the chest wall and removes the chest part from the breast MR images. Subsequently, the cleavage and its motion artifacts are removed, distinguishing the separate breasts, where the edge points are sampled for curve fitting. Next, a region growing method is applied to find the potential nipple region. Finally, the potential nipple region above the simulated curve can be removed in order to retain the original smooth contour. Results: The simulation methods can achieve the least root mean square error (RMSE) for certain cases. The proposed YBnd and (Dmin+Dmax)/2 methods are significant due toP = 0.000. The breast contour curve detected by the two proposed methods is closer than that determined by the edge detection method. The (Dmin+Dmax)/2 method can achieve the lowest RMSE of 1.1029 on average, while the edge detection method results in the highest RMSE of 6.5655. This is only slighter better than the comparison methods, which implies that the performance of these methods depends upon the conditions of the cases themselves. Under this method, the maximal Dice coefficient is 0.881, and the centroid difference is 0.36 pixels. Conclusions: The contributions of this study are twofold. First, a method was proposed to identify and segment the nipple in breast MR images. Second, a curve-fitting method was used to simulate the breast contour, allowing the breast to retain its original smooth shape.

62 RADIOLOGY AND NUCLEAR MEDICINE↗