A Dynamically Stabilized Single‐Nickel Electrocatalyst for Selective Reduction of Oxygen to Hydrogen Peroxide

Abstract On‐location electrochemical generation of H 2 O 2 is of great current interest. Herein, selective two‐electron reduction of O 2 to H 2 O 2 by a single [Ni II (H 2 O) 6 ] 2+ cation that is dynamically associated with a negatively charged metal–organic layer (MOL) by hydrogen bonding and coulombic interactions is reported. In contrast, Ni II centers covalently immobilized on the MOL reduce O 2 to H 2 O in a four‐ electron process. Oxygen adsorption by [Ni II (H 2 O) 6 ] 2+ followed by two‐electron reduction generates neutral [Ni II (H 2 O) 4 (OH)(OOH)] 0 , which momentarily disconnects from the negatively charged MOL to avoid the injection of additional electrons. Release of H 2 O 2 from [Ni II (H 2 O) 4 (OH)(OOH)] 0 regenerates [Ni II (H 2 O) 6 ] 2+ , which regains affinity to the MOL. Such dynamically associated Ni II single‐metal electrocatalysts ensure high selectivity and represent a new strategy for generating selective catalysts for electrochemical production of important chemicals.

Wang, Tingting↗

Summary of the IAEA technical meeting on plasma disruptions and their mitigation

Here we summarize the contributions presented at the IAEA technical meeting on plasma disruptions and their mitigation, held virtually, 20–23 July 2020. The meeting brought together more than 120 experts from nuclear fusion research sites worldwide to discuss experimental, theoretical and modelling work in the field of plasma disruptions with special emphasis on developing a solid basis for possible disruption mitigation strategies in ITER and next generation fusion devices. The main topics of the meeting were: (i) disruption consequences, including electromagnetic loads, heat loads, and runaway electrons; (ii) disruption prediction and avoidance, including machine learning and physics-based approaches, and control aspects; and (iii) disruption mitigation, including shattered pellet injection, alternative techniques and general aspects of disruption mitigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Climate Response to Stratospheric Aerosol Geoengineering Can Be Tailored Using Multiple Injection Locations

By injecting different amounts of SO 2 at multiple different latitudes, the spatial pattern of aerosol optical depth (AOD) can be partially controlled. This leads to the ability to influence the climate response to geoengineering with stratospheric aerosols, providing the potential for design. In this work, we use simulations from the fully coupled whole-atmosphere chemistry climate model CESM1(WACCM) to demonstrate that by appropriately combining injection at just four different locations, 30°S, 15°S, 15°N, and 30°N, then three spatial degrees of freedom of AOD can be achieved: an approximately spatially uniform AOD distribution, the relative difference in AOD between Northern and Southern Hemispheres, and the relative AOD in high versus low latitudes. For forcing levels that yield 1–2°C cooling, the AOD and surface temperature response are sufficiently linear in this model so that the response to different combinations of injection at different latitudes can be estimated from single-latitude injection simulations; nonlinearities associated with both aerosol growth and changes to stratospheric circulation will be increasingly important at higher forcing levels. Optimized injection at multiple locations is predicted to improve compensation of CO 2 -forced climate change relative to a case using only equatorial aerosol injection (which overcools the tropics relative to high latitudes). The additional degrees of freedom can be used, for example, to balance the interhemispheric temperature gradient and the equator to pole temperature gradient in addition to the global mean temperature. Further research is needed to better quantify the impacts of these strategies on changes to long-term temperature, precipitation, and other climate parameters.

54 ENVIRONMENTAL SCIENCES↗

Flexible Geothermal Power Generation utilizing Geologic Thermal Energy Storage (Final Seedling Project Report)

This report concludes that there is a cost-effective strategy for seasonal storage of heat that will provide firm, but dispatchable, electrical generating capacity in times when other renewable energy is not available to meet demand. Deployment of the technology appears to require no new technology, but instead combines solar, geothermal, and conventional oil and gas drilling technologies in a novel way. The study basis is the use of sedimentary geologic formations as a medium for thermal energy storage (TES), specifically for heat collected in concentrating solar collectors. The study identifies methodologies that could be used to transport this heat into and out of the subsurface in order to produce dispatchable electrical power, and reports on initial optimization results. The GeoTES system (heat input, storage, heat recovery, and heat to electric conversion) described in this analysis has the potential to provide a unique pathway for increasing the grid penetration of renewable energy in large blocks of power and across many states and regions. Further, the system can be used both to meet the nation’s flexible energy needs while also improving grid stability and reliability. The present study evaluated the use of a large number of dedicated wells to store and recover the heat, essentially creating a synthetic geothermal reservoir. The use of sedimentary geology allows the wells to be drilled at low cost. Dedicated hot and cold wells are used, arranged in a five-spot well pattern with each hot or cold well surrounded at an appropriate distance by the opposite type of well. In large numbers this becomes alternating rows of hot and cold wells. Each hot and cold well is operated using a push-pull strategy. This configuration provides the ability to immediately recover stored hot fluid from a GeoTES reservoir, or to store the heat over many months for recovery at low loss when needed. This is a practical approach for managing the system’s fluid inventory and reducing parasitic load. The production and injection power requirements are reduced because the rows of wells operating in “push” mode provide help to the wells operating in “pull” mode, and vice-versa. Initial charging of a GeoTES system increases the heat recovery temperature. Increasing the duration of the charging period decreases the magnitude of the temperature fluctuations that occur following prolonged system operation. Because of direct contact of the heated water with the reservoir formation, the production of both hot water and steam from the TES, and the temperature ranges of the recovered fluid (190 – 230°C or 375 – 445°F), conventional geothermal power cycles were used to convert the stored heat to electricity. A power cycle configuration for the GeoTES system was selected following a screening study of a number of flash, and flash/binary hybrid options. This analysis concluded that, of the configurations evaluated, a dual-stage flash steam cycle provides the lowest capital costs per unit net power generation with an acceptable hot brine inlet fluid flow rate. The evaluation included the power plant cost estimate, the cost and number of wells and the associated parasitic loads. Annual power generation performance was simulated to evaluate capacity factor and LCOE. The LCOE calculated for the inherently high capacity GeoTES system was $\$$0.13/kWhe. This value was calculated for the case where the solar thermal collector was sized in such a way that the solar collectors permitted an annual power plant capacity factor of up to 97%. The power cycle was able to provide power to the grid every night of the year, and flexible base-load power during the winter, if needed. This LCOE value compares favorably with reported values for solar photovoltaic plus battery energy storage (PV+BES) systems in the open literature, i.e. $\$$0.148/kWhe for a PV+BES system with 4 hours of electrochemical battery energy storage capacity. Addition of battery energy storage with more hours of storage would further increase PV+BES system LCOE and increase the separation between GeoTES and PV+BES. A GeoTES system would therefore provide superior economics for high capacity and long duration solar energy storage.

14 SOLAR ENERGY↗

SimCCS 3.0 User GUIDE

Carbon Capture and Storage (CCS) is an important technology aimed at reducing CO 2 emissions and contributing to the mitigation strategies of climate change. The process involves three main steps: CO 2 capture, transport, and storage. Specifically, CO 2 is captured from industrial facilities, such as coal-fired power plants and natural gas processing plants. It is then transported through infrastructure networks, such as pipelines, rails, and ships, and injected into underground geological formations, such as depleted oil and gas reservoirs or deep saline aquifers, for permanent storage. The entire CCS value chain encompasses multiple components, including CO 2 sources, transport networks, and storage sites. The proper design of CCS transport infrastructure is an essential step for the deployment of CCS technology. However, the design is not a trivial process, as it presents many challenges and requires consideration of numerous economic, social, and environmental factors.

42 ENGINEERING↗

Successful In Situ Remediation of Cr(VI)-Impacted Deeper Vadose Zone Soils for Groundwater Protection - 18603

Shallow soil at a former industrial wood treating facility was impacted with chromium, arsenic, and copper above cleanup goals and shallow soil has been excavated for protection of direct contact exposure pathways. Deeper vadose zone soil was predominantly impacted with chromium and was undergoing remediation for long-term groundwater protection. The 920-meter (m) long Cr(VI) groundwater plume has undergone full-scale remediation with groundwater recirculation and in situ bioremediation. Following approximately 4 years of operation, the Cr(VI) groundwater plume, with former source area groundwater concentrations over 10,000 micrograms per liter (μg/L), has been reduced to below the laboratory method reporting limit (0.50 μg/L). Approximately 23,000 cubic meters (m{sup 3}) of deeper (4.5 m - 11 m below ground surface, bgs) vadose zone soil required Cr(VI) remediation. The remediation strategy relied on reduction of Cr(VI) and geochemical fixation as trivalent chromium (Cr(III)) and iron hydroxide precipitates. Chromium reduction was facilitated by a carbon source (corn syrup and methanol) to establish and maintain biogeochemical reducing conditions and ferrous iron to support direct Cr(VI) chemical reduction. Combined, the injected soil moisture, carbon source and ferrous iron supported fast and sustained ferrous/ferric iron cycling and Cr(VI) reduction. Remedy performance monitoring included time-series water quality data from a network of vacuum lysimeters and confirmation soil borings. Reagent was applied either through liquid injection wells and direct-push injection points, or by deep soil mixing methodology in areas with difficult geology (i.e., fine-grained soils and discontinuous iron-silica hardpan layer). Following both phases of deep soil remediation, soils met long-term protection of groundwater remediation action objectives. In situ treatment of soils provides a cost-effective remedial solution compared to excavation, specifically when impacts are deep and long-term protection of groundwater is a primary remediation goal. The delivery methods employed in this case study can be applied to sites impacted with a broad range of contaminants amendable to geochemical fixation (e.g., chromium, uranium, strontium, nitrate, etc.). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DeFault: DEep‐Learning‐Based FAULT Delineation Using the IBDP Passive Seismic Data at the Decatur CO2 Storage Site

Abstract The carbon capture, utilization, and storage (CCUS) framework is an essential component in reducing greenhouse gas emissions, with its success hinging on the comprehensive knowledge of subsurface geology and geomechanics. Passive seismic event relocation and fault detection offer vital insights into subsurface structures and the ability to monitor fluid migration pathways. Accurate identification and localization of seismic events, however, face significant challenges, including the necessity for high‐quality seismic data and advanced computational methods. To address these challenges, we introduce a novel deep learning method, , specifically designed for passive seismic source relocation and fault delineating for passive seismic monitoring projects. By leveraging data domain‐adaptation, allows us to train a neural network with labeled synthetic data and apply it directly to field data. Using , the passive seismic sources are automatically clustered based on their recording time and spatial locations, and subsequently, faults and fractures are delineated accordingly. We demonstrate the efficacy of on a field case study involving injection related microseismic data from Decatur, Illinois area. Our approach accurately and efficiently relocated passive seismic events, identified faults and could aid in potential damage induced by seismicity. Our results highlight the potential of as a valuable tool for passive seismic monitoring, emphasizing its role in ensuring CCUS project safety. This research bolsters the understanding of subsurface characterization in CCUS, illustrating machine learning’s capacity to refine these methods. Ultimately, our work has significant implications for CCUS technology deployment, an essential strategy in combating climate change. Plain Language Summary In our quest to tackle climate change, we use a strategy known as carbon capture, utilization, and storage (CCUS) to keep greenhouse gases out of the atmosphere. This strategy relies heavily on our ability to understand what's happening deep under the earth's surface. To make sure we store super critical safely, we need to accurately map out the geological structure, especially faults, but this is tough without high‐quality data and complex computer programs. We've developed a new tool called “DeFault,” which uses advanced machine learning to improve how we find and map these underground features. “DeFault” is smart enough to learn from numerically simulated data and then apply what it’s learned to real‐world situations. It groups together seismic activity—tiny tremors and shifts in the earth—based on when and where they happen, which helps us spot where there might be cracks or faults. We tested “DeFault” in Illinois, where CO 2 is injected underground, and it successfully pinpointed where these tremors occurred and mapped out the faults, helping to prevent accidents accurately in the future. Our study shows that “DeFault” will be a powerful ally in making CCUS safer and more effective, especially for the Illinois Basin Decatur Project. Key Points Faults and fractures introduced by carbon storage can be monitored by passive seismicity DeFault algorithm enables an automatic process for accurate and efficient passive seismic event locating and clustering

58 GEOSCIENCES↗

Mapping the combustion modes of a dual-fuel compression ignition engine

Compression-ignition (CI) engines can produce higher thermal efficiency (TE) and thus lower carbon dioxide (CO 2 ) emissions than spark-ignition (SI) engines. Unfortunately, the overall fuel economy of CI engine vehicles is limited by their emissions of nitrogen oxides (NO x ) and soot, which must be mitigated with costly, resource- and energy-intensive aftertreatment. NO x and soot could also be mitigated by adding premixed gasoline to complement the conventional, non-premixed direct injection (DI) of diesel fuel in CI engines. Several such “dual-fuel” combustion modes have been introduced in recent years, but these modes are usually studied individually at discrete conditions. This paper introduces a mapping system for dual-fuel CI modes that links together several previously studied modes across a continuous two-dimensional diagram. This system includes the conventional diesel combustion (CDC) and conventional dual-fuel (CDF) modes; the well-explored advanced combustion modes of HCCI, RCCI, PCCI, and PPCI; and a previously discovered but relatively unexplored combustion mode that is herein titled “Piston-split Dual-Fuel Combustion” or PDFC. Tests show that dual-fuel CI engines can simultaneously increase TE and lower NO x and/or soot emissions at high loads through the use of Partial HCCI (PHCCI). At low loads, PHCCI is not possible, but either PDFC or RCCI can be used to further improve NO x and/or soot emissions, albeit at slightly lower TE. These results lead to a “partial dual-fuel” multi-mode strategy of PHCCI at high loads and CDC at low loads, linked together by PDFC. Drive cycle simulations show that this strategy, when tuned to balance NO x and soot reductions, can reduce engine-out CO 2 emissions by about 1% while reducing NO x and soot by about 20% each with respect to CDC. This increases emissions of unburnt hydrocarbons (UHC), still in a treatable range (2.0 g/kWh) but five times as high as CDC, requiring changes in aftertreatment strategy.

Engineering↗

EV Hosting Capacity Analysis on Distribution Grids

The increasing trend in electric vehicle (EV) adoption can cause challenges to traditional electric grid operations if utilities are not equipped with tools and methods to effectively manage these fleets. Growing EV charging loads will alter the magnitude and duration of conventional peaks in demand profiles and even significantly shift them, potentially causing operational violations in the distribution grid. This paper presents the development and results of an EV hosting capacity tool to quantify the impacts of injecting large numbers of EV charging loads and to determine the available capacity of existing distribution feeders to continue providing reliable and affordable grid operations. Tools like the hosting capacity analysis would enable utilities to better prepare for grid operations in the near future while exploring the impact and effectiveness of strategies to manage these loads, such as peak pricing and smart charging. This paper evaluates the hosting capacity of some real-world feeders to accommodate EV charging loads, including extreme fast-charging options.

distribution grid↗

Fundamental-Frequency Reactive Circulating Current Injection for Capacitor Voltage Balancing in Hybrid-MMC HVDC Systems During Riding Through PTG Faults

Here, this article presents a comprehensive analysis and a novel solution for the discharge problem on the half-bridge submodules' (HBSMs') capacitors in the hybrid modular multilevel converter (MMC)-based high-voltage direct current transmission systems under a long-term (e.g., several minutes or longer) pole-to-ground fault condition. The mechanism of this issue is analyzed, and then a solution based on fundamental-frequency reactive circulating current (FFRCC) injection is proposed. The influence of FFRCC injection is analyzed in terms of the fluctuated arm capacitor energy and the current stress of semiconductors. Moreover, an enhanced arm voltage modulation method based on HBSMs and full-bridge submodules coordinate control is proposed to accelerate the capacitor voltage balance of HBSMs. Finally, the performance of the proposed control strategy is verified by the simulation results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capturing the Impact of Fuel Octane Number on Modern Gasoline Vehicles with Octane Indices

The need for high efficiency automotive engines has led to more complex air handling and fuel injection systems, higher compression ratios, more advanced combustion and aftertreatment systems, and the use of fuels with higher octane ratings. Higher octane number fuels have a lower propensity to knock. This work studies the influence of changing fuel octane rating on two modern production gasoline vehicles, one with a naturally aspirated, port injected engine and the other with a turbocharged, direct injected engine, using fuels with four different octane number grades (with 85, 87, 91, and 93 anti-knock indices) and operated over a variety of driving cycles and temperature conditions. Unlike previous studies, this effort develops and demonstrates a methodology that isolates fuel effects on fuel consumption and provides a clear view of the octane impact on existing vehicles. While fuel octane rating can also impact factors such as the allowable compression ratio and gear shifting strategies, this study examines fuel consumption changes that are solely attributable to octane rating on production vehicles. The developed approach uses results from drive cycle as well as steady-state tests along with response surface modeling to predict the engine combustion phasing and changes in efficiency for each fuel relative to the baseline 87 anti-knock index (AKI) fuel. The methodology is then used to capture the role of fuel octane rating on powertrain efficiency over Environmental Protection Agency (EPA) certification drive cycles and demonstrate the variation of that impact as a function of powertrain output power. Based on the vehicles and fuels tested in this study, the metrics indicate that the effects of octane on efficiency are limited to a portion of the operating modes represented in the driving cycles used for vehicle certification. In addition, an octane potential benefit index (OPBI) suggests that the vehicle with the turbocharged, direct injected engine has a greater potential to benefit from higher octane number fuel compared to the naturally aspirated, port injected engine and proposes a way to quantify this impact for production vehicles.

Jehlik, Forrest↗

Effects of input gradient regularization on neural networks time-series forecasting of thermal power systems

This study proposes using neural networks, specifically gated recurrent unit (GRU), long-short-term memory (LSTM), and transformer networks, to improve control strategies in a 450 MW coal-fired power plant. However, neural networks face issues of becoming overly dependent on just a few variables to make predictions, which negatively impacts control decisions that rely on the model to determine the value of all manipulated variables. The paper introduces regularization techniques, including noise injection and input gradient regularization, during the training phase. Here, the work presents novel contributions in adapting neural networks to control industrial systems and applying regularization techniques from computer vision to industrial process control. Results demonstrate the effectiveness of input gradient regularization in reducing model dependence on subsets of variables, emphasizing the balance between fidelity and controllability. Further exploration is recommended, including the development of recurrent transformers, closed-loop control testing, and a sensitivity analysis on computer models to provide further insight.

20 FOSSIL-FUELED POWER PLANTS↗

Evolution of storage monitoring – update in response to commercial and regulatory drivers

Carbon Capture and Storage (CCS) is in transition from first-of-a kind projects and research-orientated pilots to commercially-motivated applications. Monitoring results from many newly developed and planned large scale commercial projects are limited; however, it is worthwhile to assess their evolution and consider new strategies as part of an effort to assess and document best practices. Commercial monitoring is targeted to activities that comply with regulatory drivers and de-risk investments. Commercial monitoring also supports accounting that storage has occurred and is tied to project financing. It deals with long time frames and large volumes injected into multiple wells and multiple projects in favorable areas. We see developing trends toward reproducible workflows that systematically reduce risks and clarify expectations for oversight and long-term surveillance. Monitoring techniques showing increasing trends include injection zone pressure as a history-matching and compliance tool. To reduce cost and environmental impact of time-lapse seismic data collection, deploying new approaches and tools, such as use of fibre and installed sources are increasingly applied. Concern over the risk of induced seismicity by regulatory bodies and the general public has increased, which has also resulted in increased monitoring. Some techniques used in the early research phases have been sidelined or used only in restricted applications. For example, geochemical analyses in the injection zone as well as the environment are now being deployed less than it was in research-oriented programs, except in the US where it is required by the permitting process. Expectations of frequent area-wide near surface monitoring have also decreased.

25 ENERGY STORAGE↗

Confronting the water potential information gap

Water potential directly controls the function of leaves, roots and microbes, and gradients in water potential drive water flows throughout the soil–plant–atmosphere continuum. Notwithstanding its clear relevance for many ecosystem processes, soil water potential is rarely measured in situ, and plant water potential observations are generally discrete, sparse, and not yet aggregated into accessible databases. These gaps limit our conceptual understanding of biophysical responses to moisture stress and inject large uncertainty into hydrologic and land-surface models. Here, we outline the conceptual and predictive gains that could be made with more continuous and discoverable observations of water potential in soils and plants. We discuss improvements to sensor technologies that facilitate in situ characterization of water potential, as well as strategies for building new networks that aggregate water potential data across sites. Here, we end by highlighting novel opportunities for linking more representative site-level observations of water potential to remotely sensed proxies. Together, these considerations offer a road map for clearer links between ecohydrological processes and the water potential gradients that have the ‘potential’ to substantially reduce conceptual and modelling uncertainties.

58 GEOSCIENCES↗

Selective triplet exciton formation in a single molecule

The formation of excitons in organic molecules by charge injection is an essential process in organic light-emitting diodes (OLEDs). According to a simple model based on spin statistics, the injected charges form spin-singlet (S1) excitons and spin-triplet (T 1 ) excitons in a 1:3 ratio. After the first report of a highly efficient OLED based on phosphorescence, which is produced by the decay of T 1 excitons, more effective use of these excitons has been the primary strategy for increasing the energy efficiency of OLEDs. Another route to improving OLED energy efficiency is reduction of the operating voltage. Because T 1 excitons have lower energy than S 1 excitons (owing to the exchange interaction), use of the energy difference could—in principle—enable exclusive production of T 1 excitons at low OLED operating voltages. However, a way to achieve such selective and direct formation of these excitons has not yet been established. Here we report a single-molecule investigation of electroluminescence using a scanning tunnelling microscope and demonstrate a simple method of selective formation of T 1 excitons that utilizes a charged molecule. A 3,4,9,10-perylenetetracarboxylicdianhydride (PTCDA) molecule adsorbed on a three-monolayer NaCl film atop Ag(111) shows both phosphorescence and fluorescence signals at high applied voltage. In contrast, only phosphorescence occurs at low applied voltage, indicating selective formation of T 1 excitons without creating their S 1 counterparts. The bias voltage dependence of the phosphorescence, combined with differential conductance measurements, reveals that spin-selective electron removal from a negatively charged PTCDA molecule is the dominant formation mechanism of T 1 excitons in this system, which can be explained by considering the exchange interaction in the charged molecule. Our findings show that the electron transport process accompanying exciton formation can be controlled by manipulating an electron spin inside a molecule. We anticipate that designing a device taking into account the exchange interaction could realize an OLED with a lower operating voltage.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Cost and Benefit of Enhancing Cybersecurity for Hybrid AC/DC Grids

As critical interfaces of AC grids and DC grids inside a hybrid AC/DC grid, the voltage-sourced-converter (VSC) has been demonstrated to be vulnerable to false data injection (FDI) cyber-attacks. As a result, the cyber-attack-induced AC grid frequency deviations and DC grid voltage deviations threaten the secure operation. Here, to enhance cybersecurity in a not only feasible but also cost-effective manner, this paper proposes a cost-benefit-based cyber-defense strategy for a hybrid AC/DC grid. First, this paper establishes a spatial-temporal dual cyber-attack evaluation model, in which the cyber-attack-induced frequency and voltage deviations are modelled in both a spatially and temporally dual manner. Then, the proposed cost-benefit-based cyber-defense strategy is modelled as a VSC commitment problem to achieve the trade-off between maximizing the cyber-defense benefits and minimizing the cyber-defense costs. The VSC commitment problem is then mathematically convexified into a mixed-integer second-order cone programming (MISOCP) problem, which could be efficiently solved in an event-triggered manner against unfolding cyber-attack events. Simulation results on a test hybrid AC/DC grid verified the feasibility and the cost-effectiveness of the proposed cyber-defense strategy.

cost-benefit analysis↗

Assessing the technical aspects of ocean-alkalinity-enhancement approaches

Ocean alkalinity enhancement (OAE) is an emerging strategy that aims to mitigate climate change by increasing the alkalinity of seawater. This approach involves increasing the alkalinity of the ocean to enhance its capacity to absorb and store carbon dioxide (CO 2 ) from the atmosphere. This chapter presents an overview of the technical aspects associated with the full range of OAE methods being pursued and discusses implications for undertaking research on these approaches. Various methods have been developed to implement OAE, including the direct injection of alkaline liquid into the surface ocean; dispersal of alkaline particles from ships, platforms, or pipes; the addition of minerals to coastal environments; and the electrochemical removal of acid from seawater. Each method has its advantages and challenges, such as scalability, cost effectiveness, and potential environmental impacts. The choice of technique may depend on factors such as regional oceanographic conditions, alkalinity source availability, and engineering feasibility. This chapter considers electrochemical methods, the accelerated weathering of limestone, ocean liming, the creation of hydrated carbonates, and the addition of minerals to coastal environments. In each case, the technical aspects of the technologies are considered, and implications for best-practice research are drawn. The environmental and social impacts of OAE will likely depend on the specific technology and the local context in which it is deployed. Therefore, it is essential that the technical feasibility of OAE is undertaken in parallel with, and informed by, wider impact assessments. While OAE shows promise as a potential climate change mitigation strategy, it is essential to acknowledge its limitations and uncertainties. Further research and development are needed to understand the long-term effects, optimize techniques, and address potential unintended consequences. OAE should be viewed as complementary to extensive emission reductions, and its feasibility may be improved if it is operated using energy and supply chains with minimal CO 2 emissions.

54 ENVIRONMENTAL SCIENCES↗

Understanding the Mechanism of Light and Elevated Temperature Induced Degradation of p-type Silicon Solar Cells (Final Report)

Light- and elevated-temperature-induced degradation (LeTID) was first discovered in multicrystalline Si (mc-Si) solar cells and was initially attributed to metal impurities. Later, LeTID was reported in Czochralski (Cz) and float-zone (FZ) Si, and is considered as an important efficiency loss mechanism in p-type passivated emitter rear contact (p-PERC) Cz Si solar cells. LeTID causes ~10% relative and permeant efficiency losses in these cells in warmer climate regions where the module temperature is > 50 °C. Unlike light-induced degradation (LID), which is also observed in p-PERC cells, LeTID is slower and takes weeks to months in the field to saturate. Another difference compared to LID is that regeneration in LeTID proceeds very slowly, and field regeneration could take > 25 years — essentially the life of the module. Unlike B-O defects that are responsible for LID, neither B nor O impurities are directly involved in LeTID. LeTID appears to be unique to p-type Si, and is also observed in Ga-doped Si. Currently, most experimental evidence relates LeTID to the injection of hydrogen present in the dielectric surface passivation layers, such as SiN x and Al 2 O 3 , into the monocrystalline Si (c-Si) bulk during the fast-firing step. The involvement of hydrogen is further strengthened by controlled studies that show that increasing the amount of hydrogen in the dielectric during fast-firing increases the degree of LeTID. Similar to LID, a regeneration process has been discovered for LeTID. Regeneration of LeTID defects occurs when samples are exposed to 2–4 Suns illumination at elevated temperatures of 140–220 °C for 2–15 hr. Given the slower kinetics of LeTID and sample regeneration compared to LID, this poses a challenge for the manufacturing and field reliability of p-PERC cells, which will be the leading photovoltaic technologies over the next decade. Therefore, there is a need to understand LeTID and develop strategies to mitigate this effect. The defect responsible for LeTID has been extensively studied with over 100 publications, but direct spectroscopic evidence of this defect’s structure is lacking. Without an atomistic understanding of the LeTID defect, it is difficult to assess the long-term efficacy of the current industrial mitigation strategies. This, in turn, has implications on energy production for tens of gigawatts of these cells that will be deployed yearly worldwide. Using electron paramagnetic resonance, we identified a defect associated with LeTID with a g-value of 2.006, which we attribute to an Si dangling bond in an extended defect such as a vacancy agglomerate with H possibly within or in close vicinity. These vacancy agglomerates are likely created during the firing process, during which time H atoms are also injected into the bulk from the hydrogenated SiN x dielectric layer. Our atomistic-level insight shows that the LeTID defect can be mitigated by targeted intrinsic defect engineering of the c-Si material through a slower pull rate of the Cz ingot or 1000 °C oxygen ambient processing of the Si wafer to reduce the vacancy concentration. This project was a collaborative effort between the Colorado School of Mines and the National Renewable Energy Laboratory.