Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

Toward full simulations for a liquid metal blanket: part 2. Computations of MHD flows with volumetric heating for a PbLi blanket prototype at Ha ~10 4 and Gr ~10 12

On the pathway toward full simulations for a liquid metal (LM) blanket, this part 2 extends a previous study of purely magnetohydrodynamic (MHD) flows in a DCLL blanket in reference Chen et al (2020 Nucl. Fusion 60 076003) to more general conditions when the MHD flow is coupled with heat transfer. The simulated prototypic blanket module includes all components of a real LM blanket system, such as supply ducts, inlet and outlet manifolds, multiple poloidal ducts and a U-turn zone. Volumetric heating generated by fusion neutrons is added to simulate thermal effects in the flowing lead–lithium (PbLi) breeder. The MHD flow equations and the energy equation are solved with a DNS-type finite-volume code ‘MHD-UCAS’ on a very fine mesh of 470 × 10 6 cells. The applied magnetic field is 5 T (Hartmann number Ha ~ 10 4 ), the PbLi velocity in the poloidal ducts is 10 cm s –1 (Reynolds number Re ~10 5 ), whereas the maximum volumetric heating is 30 MW m –3 (Grashof number Gr ~ 10 12 ). Four cases have been simulated, including forced- and mixed-convection flows, and either an electrically conducting or insulating blanket structure. Various comparisons are made between the four computed cases and also against the purely MHD flows computed earlier in reference Chen et al (2020 Nucl. Fusion 60 076003) with regards to the (1) MHD pressure drop, (2) flow balancing, (3) temperature field, (4) flows in particular blanket components, and (5) 3D and turbulent flow effects. The strongest buoyancy effects were found in the poloidal ducts. In the electrically non-conducting blanket, the buoyancy forces lead to significant modifications of the flow structure, such as formation of reverse flows, whereas their effect on the MHD pressure drop is relatively small. In the electrically conducting blanket case, the buoyancy effects on the flow and MHD pressure drop are almost negligible.

Physics↗

Magnetohydrodynamics in free surface liquid metal flow relevant to plasma-facing components

Abstract While flowing Liquid Metal (LM) Plasma-Facing Components (PFCs) represent a potentially transformative technology to enable long-pulse operation with high-power exhaust for fusion reactors, Magnetohydrodynamic (MHD) drag in the conducting LM will reduce the flow speed. Experiments have been completed in the linear open-channel LMX-U device [Hvasta et al 2018 Nucl. Fusion 58 01602] for validation of MHD drag calculations with either insulating or conducting walls, with codes similar to those used to design flowing LM PFCs for a Fusion Nuclear Science Facility [Kessel et al 2019 Fusion Sci. Technol . 75 886]. We observe that the average channel flow speed decreased with the use of conducting walls and the strength of the applied transverse magnetic field. The MHD drag from the retarding Lorentz force resulted in an increase of the LM depth in the channel that ‘piled up’ near the inlet, but not the outlet. As reproduced by OpenFOAM and ANSYS CFX calculations, the magnitude and characteristics of the pileup in the flow direction increased with the applied traverse magnetic field by up to 120%, as compared to the case without an applied magnetic field, corresponding to an average velocity reduction of ∼45%. Particle tracking measurements confirmed a predicted shear in the flow speed, with the surface velocity increasing by 300%, despite the 45% drop in the average bulk speed. The MHD effect makes the bulk flow laminarized but keeps surface waves aligned along the magnetic field lines due to the anisotropy of MHD drag. The 3D fringe field and high surface velocity generate ripples around the outlet region. It was also confirmed that the MHD drag strongly depends on the conductivity of the channel walls, magnetic field, and volumetric flow rate, in agreement with the simulations and a developed analytical model. These validated models are now available to begin to determine the conditions under which the ideal LM channel design of a constant flow speed and fluid depth could be attained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis and design of fast flow liquid Li divertor for fusion nuclear science facility (FNSF) using coupled plasma boundary and LM MHD/heat transfer codes *

The SOLPS-ITER code is utilized to analyze the boundary plasma associated with a fast-flow lithium (Li) divertor configuration in the fusion nuclear science facility (FNSF) tokamak and identify operational regimes with acceptable divertor and core conditions. Plasma transport from the SOLPS-ITER code has been coupled with a liquid metal (LM) MHD/heat transfer code to model a Li open-surface divertor design and assess its impact on the scrape-off-layer (SOL) and core plasma performance. Simulations with only Neon (Ne) impurity seeding have been conducted to evaluate its impact on meeting FNSF design demands for the divertor and upstream plasma parameters. Simulation results indicate that Ne seeding significantly mitigates divertor heat flux but potentially reduces both upstream electron and main ion density due to fuel dilution. The combined application of Ne seeding and deuterium (D 2 ) puffing is required to satisfy the FNSF design requirements on upstream density ($n^{OMP}_{e,sep}$~1× 10 20 m -3 ) and divertor energy flux ($q^{Odiv}_{\bot,max}$<10 MW m -2 ). D 2 puffing plays a role in counteracting upstream density drops and augmenting energy and momentum losses through atomic and molecular processes. The inlet Li flow velocity is systematically varied across a wide range to identify acceptable flows and corresponding LM surface temperatures. This comprehensive analysis identifies the acceptable Li flow parameters, LM surface temperature, and emitted Li fluxes necessary to meet the major design constraints. The emitted Li fluxes exhibit minimal impact on the main plasma at surface temperatures up to approximately ~525 °C, corresponding emitted Li fluxes of up to φ Li ~2X10 23 atoms s -1 . Uncertainties in the Li emission processes from the surface are also investigated, primarily influencing Li loss in the lower surface temperature range (<525 °C), with simulation results indicating a minor impact on the divertor and upstream plasma. Conversely, evaporation predominantly drives the Li loss processes at higher surface temperature ranges (>525 °C), contaminating both the divertor and upstream plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of the LCLS-II Cryogenic Distribution System

The LINAC Coherent Light Source II (LCLS-II) located at SLAC National Accelerator Laboratory (SLAC) in Menlo Park, CA, is a U.S. Department of Energy project tasked to design and build a world-class x-ray free-electron laser facility for scientific research. The Linac has superconducting radio frequency cryomodules that are connected to the cryogenic plant by the Cryogenic Distribution System (CDS), which consists of distribution boxes with heat exchangers and reliefs, feed caps, end caps, and surface, vertical, and bypass transfer lines. The CDS components were designed and built to specification by industry. The components have been delivered and their installation at SLAC will be discussed. The as-built relief system design will be presented, showing minimization of relief inlet pressure drops while meeting capacity requirements. The relieving flow pressure drops along the lengths of the CDS to centrally located reliefs at the distribution box were analysed to satisfy Pressure Vessel and Process Piping Code criteria to ensure relief performance. The sub-atmospheric 2 K circuit relieving approach will be discussed, which includes a three-way diverter isolation valve suitable for sub-atmospheric service. The component anchoring load design approach and installation into concrete floor will be discussed. This addresses loading, including seismic loading, along the component’s load path to floor anchoring system.

43 PARTICLE ACCELERATORS↗

Effect of mass flow rate on gas propagation after vacuum break in a liquid helium cooled tube

Vacuum break in particle accelerators is a major concern due to risks associated with personnel and extensive equipment damage. Continuing research in our lab focuses on the sudden loss of vacuum in the liquid helium cooled beam-line tubes of superconducting particle accelerators. In our previous research, we studied nitrogen gas propagation in a uniform tube system immersed in both normal helium (He I) and superfluid helium (He II). It was observed that He II has a stronger effect in slowing down the gas propagation compared to He I, but this effect was largely due to the variation of the point where condensation and deposition of the nitrogen gas on the tube inner wall. Here, we discuss our modifications to the tube system that now allow us to accurately control the starting location of gas condensation in both the He I and He II experiments. Systematic studies of gas propagation were conducted using this new tube system by varying the nitrogen mass flow rate at the tube inlet.

43 PARTICLE ACCELERATORS↗

Wettability and capillary effects: Dynamics of pinch-off in unconstricted straight capillary tubes

We study the interfacial evolution of immiscible two-phase flow within a capillary tube in the partial wetting regime using direct numerical simulation. We investigate the flow patterns resulting from the displacement of a more viscous fluid by a less viscous one under a wide range of wettability conditions. We find that beyond a wettability dependent critical capillary number, a uniform displacement by a less viscous fluid can transition into a growing finger that eventually breaks up into discrete blobs by a series of pinch-off events for both wetting and non-wetting contact angles. This study validates previous experimental observations of pinch-off for wetting contact angles and extends those to non-wetting contact angles. We find that the blob length increases with the capillary number. We observe that the time between consecutive pinch-off events decreases with the capillary number and is greater for more wetting conditions in the displaced phase. Here, we further show that the blob separation distance as a function of the difference between the inlet velocity and the contact line speed collapses into two monotonically decreasing curves for wetting and non-wetting contact angles. For the phase separation in the form of pinch-off, this work provides a quantitative study of the emerging length and time scales and their dependence on the wettability conditions, capillary effects, and viscous forces.

42 ENGINEERING↗

A New Proposal Generalized Predictive Control Algorithm With Polynomial Reference Tracking Applied for Sodium Fast Reactors

This paper proposes a generalized predictive control (GPC) with constraints and orthonormal Laguerre functions using the simplified model of the primary system (reactor core and intermediate heat exchanger (IHX)) of a prototypical sodium fast reactor (SFR). This paper develops a multiple-input multiple-output (MIMO) GPC with input constraints able to track polynomial references of any degree applied in coolant temperature difference across the core and fractional power. The manipulated variables of the GPC-SFR are the reactivity and the sodium flow rate of the primary and secondary pipes. Moreover, orthonormal Laguerre functions and step down condition number techniques were also applied to avoid the numerical ill-conditioning issue in quadratic programming of large systems. Thus, a GPC type-2 was designed to control fractional power, coolant temperature difference across the core and sodium tank temperature of the SFR primary system when temperature references change according to a linear ramp after reaching their steady-state operation, sustaining 100% power operation on the reactor. In order to analyze the load tracking capability of the GPC-SFR type-2, the load following from 100% fractional power (FP) to 60% FP at 0.8% FP/min rate is simulated. Constraints on the rate of coolant temperature difference across the core and reactivity were applied for the design safety. For comparison criteria, this paper compares the GPC-SFR type-2 with the GPC-SFR type-1, i.e., standard model predictive control (MPC), to verify the viability and superior performance of the proposal regarding: (a) ramp-tracking capability of temperature and load; (b) the rejections of a reactivity disturbance of -1 cent and a secondary sodium inlet temperature disturbance of +10°F; and (c) a simulation with uncertainty in reactor design. The simulations show that the GPC-SFR type-2 overcome the GPC-SFR type-1 robustness and performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangement of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective.

CFD↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

SiC Microchannel Heat Sinks for High Heat Flux Dissipation of 1 kW/cm 2

Thermal management has become a major barrier in the development of high-power micro-devices. Microchannel heat sinks (MCHS) are a promising method to dissipate high heat fluxes from high power density devices. Reducing the thermal resistance will reduce the temperature increase of the electronic device, allowing for higher powers to be achieved while maintaining a safe operating temperature. This paper reports on the use of silicon carbide (Sic) microchannels to dissipate high heat fluxes up to 1 kW/cm 2 over a footprint of 0.25 cm 2 . The use of high aspect ratio and decreased hydraulic diameter channels has allowed for very low thermal resistances to be achieved at higher heat duties compared to previous studies. The experiments performed resulted in heater temperatures of less than 60 °C and thermal resistances as low as 0.024 cm 2 . ° $C$/W between the heater surface and fluid inlet temperature. In conclusion, the demonstrated thermal performance of the SiC MCHS is an encouraging means for dissipating heat from high power density microelectronic devices.

42 ENGINEERING↗

Operation of Natural Gas Pipeline Networks With Storage Under Transient Flow Conditions

Here, we formulate a nonlinear optimal control problem for intraday operation of a natural gas pipeline network that includes storage reservoirs. The dynamics of compressible gas flow through pipes, compressors, reservoirs, and wells are considered. In particular, a reservoir is modeled as a rigid, hollow container that stores gas under isothermal conditions and uniform density, and a well is modeled as a vertical pipe. For each pipe, flow dynamics are described by a coupled partial differential equation (PDE) system in density and mass flux variables, with momentum dissipation modeled using the Darcy–Wiesbach friction approximation. Compressors are modeled as scaling up the pressure of gas between the inlet and outlet. The governing equations for all network components are spatially discretized and assembled into a nonlinear differential-algebraic equation (DAE) system, which synthesizes above-ground pipeline and subsurface reservoir dynamics into a single reduced-order model. We seek to maximize an objective function that quantifies economic profit and network efficiency subject to the flow equations and inequalities that represent operating limitations. The problem is solved using a primal–dual interior point solver, and the solutions are validated in computational experiments and simulations on several pipeline test networks to demonstrate the effectiveness of the proposed methodology.

03 NATURAL GAS↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Medium-Voltage Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules, for grid-connected applications. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of a forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangements of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective. A fully resolved model of the arrangement that yields optimal results is developed to accurately predict the temperature profile of the essential components in the submodules.

computational fluid dynamics↗

Single-Phase Dielectric Fluid Thermal Management for Power-Dense Automotive Power Electronics

This paper describes the design and performance of a dielectric fluid cooling concept for automotive power electronics. The concept combines a low-thermal-resistance package (which eliminates metalized ceramic substrates) with a high-performance convective cooling strategy (slot jets impinging on finned surfaces). Modeling was first used to design the cooling system to maximize thermal performance and minimize pumping power. Additionally, a prototype was then fabricated, and experiments were conducted to validate the model predictions using three fluids at various fluid flow rates (16.7 cm 3 /s [1 L/min] to 68.3 cm 3 /s [4.1 L/min]) and inlet temperatures (30C and 70C). The final design was compact (120-cm 3 total volume, including heat exchanger and conceptual power modules) and cooled 12 devices (e.g., silicon carbide). The validated model was then used to predict the junction-to-fluid thermal resistance and pumping power for various conditions, including 40C fluid temperature. The results predict thermal resistance values as low as 19 mm 2 K/W are possible using the dielectric fluid cooling approach. The dielectric fluid cooling system is predicted to provide thermal resistance and pumping power values that are approximately 56% and 90% lower, respectively, compared to an automotive power electronics cooling system.

30 DIRECT ENERGY CONVERSION↗

Direct Numerical Simulation of the Flow through a Randomly Packed Pebble Bed

The proposition for molten salt and high-temperature gas-cooled reactors has increased the focus on the dynamics and physics in randomly packed pebble beds. Research is being conducted on the validity of these designs as a possible contestant for the fourth-generation nuclear power systems. A detailed understanding of the coolant flow behavior is required in order to ensure proper cooling of the reactor core during normal and accident conditions. In order to increase the understanding of the flow through these complex geometries and enhance the accuracy of lower-fidelity modeling, high-fidelity approaches such as direct numerical simulation (DNS) can be utilized. Nek5000, a spectral-element computational fluid dynamics (CFD) code, was used to develop DNS fluid flow data. The flow domain consisted of 147 pebbles enclosed by a bounding wall. In the work presented, the Reynolds numbers ranged from 430 to 1050 based on the pebble diameter and inlet velocity. Characteristics of the flow domain such as volume averaged porosity, axial porosity, and radial porosity were studied and compared with correlations available in the literature. Friction factors from the DNS results for all Reynolds numbers were compared with correlations in the literature. The first- and second-order statistics show good agreement with the available experimental data. Turbulence length scales were analyzed in the flow. Reynolds stress anisotropy was characterized by utilizing invariant analysis. Overall, the results of the analysis in this study provide deeper understanding of the flow behavior and the effect of the wall in packed beds.

Yildiz, Mustafa Alper↗

Measurements of Density and Sound Speed in Mixtures Relevant to Supercritical CO2 Cycles

Abstract The objective of this research is to validate properties of mixtures relevant to supercritical carbon dioxide (sCO2) power cycles. Direct-fired sCO2 cycles are a promising technology for the future power generation systems. The working fluid of sCO2 cycles will be near and above critical point of CO2. One of the challenges is that the simulation of mixtures should consider real gas behavior. Expected operating conditions of Allam cycles reach up to 300 bar and 1000 °C. Characterizing the mixtures at the extreme conditions is an important issue in current researches and industrial applications. Thermophysical properties of mixtures may be beyond the valid range of the widely used database such as NIST REFPROP. Experimental data of mixture properties in the literature are limited which is necessary to develop high-fidelity design tools for sCO2 power cycles. We measured the density and sound speed of several multi-component mixtures. A temperature-controlled high-pressure test cell was used for the density measurements. Sound speed was measured by resonant frequency detection using an external speaker and a piezoelectric pressure sensor. Mixtures studied in this work include carbon dioxide, methane, oxygen, and water vapor. Properties of pure CO2 were measured to show the validity of our technique. Compositions were selected to be close to frozen mixtures at the inlet, mid-progress, and exhaust conditions of a model sCO2 combustor in the previous numerical simulation work. Corresponding reaction progress variables (RPV) were RPV = 0, 0.5, and 1. Temperature and pressure conditions of experiments are 310–450 K and 0–150 bar. In our study, density and sound speed from the NIST REFPROP database agree with experimental measurements within the range of our measurement uncertainties.

Energy & Fuels↗

Evaluating the Effects of Transient Purge Flow on Stator-Rotor Seal Performance

Abstract As modern engine designs target higher efficiencies through increased turbine inlet temperatures, critical turbine components are at increased risk of damage from conditions exceeding material melting temperatures. In particular, improperly designed underplatform hardware components are susceptible to damage when hot main gas path flow is ingested into the stator-rotor cavity. While all turbines inherently experience transients during operation, a majority of publicly available turbine studies have been executed using steady operating conditions or inherently transient “blowdown” rigs. For this reason, routine transient events are not well understood. To address this need, the present study utilized a combined experimental and computational approach. The test article is a continuous-duration, one-stage test turbine operating with true-scale engine hardware and seal geometries at engine-representative flow conditions. The nature of the continuous-duration facility uniquely supports the direct assessment of transient events through its ability to transition between steady-state operating conditions. The effects of a transient purge flow were investigated in this study to identify general trends for transient events in a full-scale engine. Results from multiple measurement techniques in the wheelspace region show an interdependence of transient purge flow with a thermal lag of the underplatform hardware. Through experiments conducted at different coolant-to-main gas path temperature ratios, the use of pressure measurements as an indicator of fully purged behavior was introduced, and a thermally driven influence on rim seal performance was quantified. The computational results show good agreement with experimental pressure measurements and provide insight into the physical mechanisms that drive the relationship between pressure and sealing effectiveness measurements observed for the tested geometry.

Engineering↗

The Effect of Pressure on NO x Entitlement and Reaction Timescales in a Premixed Axial Jet-In-Crossflow

This paper investigates the pressure dependency of a lean premixed jet injected into a lean vitiated crossflow with an experimentally verified detailed chemistry computational fluid dynamics (CFD) model and 53 species considered. Experimental data were taken in an axially staged combustor with an optically accessible test section, allowing the use of particle image velocimetry (PIV) and CH* chemiluminescence techniques as well as point measurement of species concentration, temperature, and pressure. The experimental data cases at one, three, and five atmospheres were selected to describe the flame stabilization dependency on pressure and gain the required knowledge for an extrapolation to engine condition. Simulated exit nitrogen oxide levels were validated with experimental emission data, and a global emission trend for the NO reduction at elevated pressure and constant turbine inlet temperature level was defined. The nitrogen oxide benefit at elevated operating pressure was justified with the significantly smaller flame surface area: the analysis of the simulated spanwise and top-view profiles showed a relatively short receded core flame with nitrogen oxide production in the center at high pressure relative to a longer and larger shear layer flame at atmospheric condition that produced NO toward the inner and outer side of the flame. Furthermore, decomposition of the Damköhler number revealed the strong influence of the reaction timescales with higher reaction rates at elevated pressure, along with a moderate influence of the turbulent timescales, showing higher turbulence intensity in the lee-side recirculation zone at lower pressure.

03 NATURAL GAS↗