MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

High frequency beam oscillation keyhole dynamics in laser melting revealed by in-situ x-ray imaging

The metal additive manufacturing industry is actively developing instruments and strategies to enable higher productivity, optimal build quality, and controllable as-built microstructure. A beam controlling technique, laser oscillation has shown potential in all these aspects in laser welding; however, few attempts have been made to understand the underlying physics of the oscillating keyholes/melt pools which are the prerequisites for these strategies to become a useful tool for laser-based additive manufacturing processes. Here, to address this gap, we utilized a synchrotron-based X-ray operando technique to image the dynamic keyhole oscillation in Ti-6Al-4V using a miniature powder bed fusion setup. We found good agreement between the experimental observations and simulations performed with a validated Lattice Boltzmann multiphysics model. The study revealed the continuous and periodic fluctuations in the characteristic keyhole parameters that are unique to the oscillating laser beam processing and responsible for the chevron pattern formation at solidification. In particular, despite the intrinsic longer-range fluctuation, the oscillating technique displayed potential for reducing keyhole instability, mitigating porosity formation, and altering surface topology. These insights on the oscillating keyhole dynamics can be useful for the future development and application of this technique.

36 MATERIALS SCIENCE↗

Microfluidic In-Situ Spectrophotometric Approaches to Tackle Actinides Analysis in Multiple Oxidation States

The study and development of present and future processes for the treatment/recycling of spent nuclear fuels require many steps, from design in the laboratory to setting up on an industrial scale. In all of these steps, analysis and instrumentation are key points. For scientific reasons (small-scale studies, control of phenomena, etc.) but also with regard to minimizing costs, risks, and waste, such developments are increasingly carried out on milli- or microfluidic devices. The logic is the same for the chemical analyses associated with their follow-up and interpretation. Due to this, over the last few years, opto–microfluidic analysis devices adapted to the monitoring of different processes (dissolution, liquid–liquid extraction, precipitation, etc.) have been increasingly designed and developed. In this work, we prove that photonic lab-on-a-chip (PhLoC) technology is fully suitable for all actinides concentration monitoring along the plutonium uranium refining extraction (plutonium, uranium, reduction, extraction, or Purex) process. Several PhLoC microfluidic platforms were specifically designed and used in different nuclear research and development (R&D) laboratories, to tackle actinides analysis in multiple oxidation states even in mixtures. The detection limits reached (tens of µmol·L −1 ) are fully compliant with on-line process monitoring, whereas a range of analyzable concentrations of three orders of magnitude can be covered with less than 150 µL of analyte. Finally, this work confirms the possibility and the potential of coupling Raman and ultraviolet–visible (UV–Vis) spectroscopies at the microfluidic scale, opening the perspective of measuring very complex mixtures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

Flow Sensor Test Article (F-STAr) (Design and Fabrication Status Report)

The Flow Sensor Test Article (F-STAr) is a test article currently under construction for the Mechanisms Engineering Test Loop (METL). F-STAr was designed to provide high sodium flowrate capabilities for sensor calibration, component testing, and fluid studies. Figure 1 shows two solid model views of the new test article. F-STAr includes a high-capacity pump that can provide a nominal flowrate of 120 GPM; a test section support structure that can accommodate a wide array of sub-test articles and their instrumentation; and finally, a heating and cooling system to aid in controlling the testing environment. Initially, F-STAr will be configured to test liquid metal flow sensors, specifically field shift sensors like the Eddy Current Flow Sensors (ECFS) based on the RDT C4-7T standard. To test these sensors, two test sections were designed that attempt to model Sodium Fast Reactor (SFR) outlet conditions. Figure 2 shows models of the “Full-Scaled Test Section” (FSTS) that represents a generic SFR fuel handling socket and a “Pseudo-Scaled Test Section” (PSTS) that represents a generic array of scaled fuel handling sockets. While F-STAr will be configured to test ECFS’s, it can also be outfitted to meet other experimental needs. For example, F-STAr could be setup with a test section that includes a fluidic diode or a component test investigating the performance of hydrodynamic bearings. Other test sections include studies of sodium thermal hydraulics like thermal striping. Overall, F-STAr is a flexible test article designed to accommodate many needs. This report will provide a status update on the design and construction of F-STAr. Manufacturing of all components has commenced, and several components have already been completed. These components include the pump and test section assembly stand. Other components, such as the heater, have been completed but were rejected due to the vendor not meeting the requirements of the purchase order. Lastly, the submersible flowmeter and main flange components are under construction, and their status will be reviewed in this report. Overall, most of the F-STAr components and parts will be completed by the end of September 2022.

42 ENGINEERING↗

Fiber Optic Temperature Sensor System Using Air-Filled Fabry–Pérot Cavity with Variable Pressure

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

47 OTHER INSTRUMENTATION↗

Plutonium Basket Counter Measurement Control Q3-Q4 2023

The Plutonium Basket Counter (PBC) is a spent fuel nuclear safeguards instrument that was developed to measure spent-fuel elements from MAGNOX-type research reactors and determine their plutonium content. The instrument is designed to measure fuel elements in spent fuel cooling pools through underwater operation, but it is also able to measure radiation sources in air. The PBC determines fuel plutonium content by detecting neutrons with an array of Helium-3 detectors. The electronics make use of a JSR-15 shift register for data collection and IAEA Neutron Coincidence Counting (INCC) software for data analysis. The PBC is used to determine the 240 Pu content in spent MAGNOX fuel elements grouped into basket-like bundles, thus the instrument’s name. Reactor burnup calculations can be used in conjunction with the data from the PBC to estimate the total plutonium content in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stomata in-sight: Integrating live confocal microscopy with leaf gas exchange and environmental control

Stomatal anatomy (aperture area, length, and width) influences leaf-level physiology traits including conductance to water vapor. Stomatal anatomy can be visualized in situ by microscopy, but the difficulty of regulating the atmospheric environment of a microscope stage means that the conditions under which imaging is done are rarely physiologically relevant. Alternatively, leaf gas exchange instruments that measure gas fluxes reflect stomatal anatomical characteristics in aggregate, but the relative strengths of anatomical traits to control water use (e.g. size vs density) cannot be firmly established. To reconcile the microscopic stomatal characteristics with leaf-level gas exchange, we describe a tool that combines laser scanning confocal microscopy, gas exchange instruments, and machine-learning image analysis to simultaneously observe anatomical characteristics of many (>40) stomata alongside leaf-level traits like photosynthesis, transpiration, and stomatal conductance. We demonstrate how the tool has the resolution capable of quantifying aperture sizes and variability in maize (Zea mays) leaves under 5 steady-state light/pCO 2 treatments while tightly controlling other environmental variables like relative humidity and temperature. A model used to calculate stomatal conductance from measured apertures and stomatal density accurately matched stomatal conductance measured by gas exchange. This technical advancement will provide insight on how stomatal anatomy and function trade off to influence stomatal conductance and leaf-level water use efficiency.

59 BASIC BIOLOGICAL SCIENCES↗

Poster for intern poster presentation

Inside the hot cells of HFEF (Hot Fuel Examination Facility) and FCF (Fuel Conditioning Facility) reside several large, purpose built 6500-pound cranes. Each crane holds several DC motors that must all be actuated without error for years on end. However, when a component becomes inoperable inside one of these crane carriages, it must be taken out of cell, fixed, and reevaluated. In order to test these cranes and EMMs, two test boxes were built. However, the test cabinets were designed with few engineering controls, zero released documentation, and they were both at some level of disrepair. This poster goes over some of the particulars that go into a control box redesign, mostly focusing on the drawing and DCR process.

42 - ENGINEERING↗

FOCAL Campaign I: Advanced Wind Turbine Control Strategies

Campaign I of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aims to generate a dataset enabling the validation of aerodynamic performance of a scaled turbine mounted on a rigid tower in a fixed condition. The turbine considered in the FOCAL testing campaigns is the IEA-Wind 15MW Reference Wind Turbine. This scaled model is capable of simulating advanced blade-pitch control strategies in a high-quality wind field. The turbine is fully instrumented to record a variety of parameters in real time such as structural loads and dynamics. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Constant wind and blade-pitch with varying rotor speeds LC 2.X - Constant wind and rotor speed with varying blade-pitch LC 3.X - Varying wind with active closed-loop control Detailed properties on the modeled system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaign I: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine. UMaine ASCC Report Number 23-40-1183. Details on the results of the verification and validation are found in the following reference: Mendoza, Nicole et al., "Verification and Validation of Model-Scale Turbine Performance and Control for the IEA Wind 15 MW Reference Wind Turbine," Energies, vol. 15, no. 20, 2022, https://doi.org/10.3390/en15207649.

17 WIND ENERGY↗

Architecture of the personnel protection systems for Spallation Neutron Source Second Target Station

The Oak Ridge National Laboratory (ORNL) is implementing a major upgrade to the Spallation Neutron Source (SNS) facility, encompassing the addition of the Second Target Station (STS). Preliminary design reviews have been conducted on several STS Personnel Protection Systems (PPS). The reviews focused primarily on the integration with the existing SNS PPS, the new proton transport tunnel, and the target areas. Development of the PPS is ongoing, to ensure a coherent safety system with the mission of protecting users and workers from prompt radiation hazards while providing high beam availability to operations. The STS PPS element in the Integrated Control System (ICS) is a facility-wide system composed of multiple safety subsystems, including the Ring to Second Target (RTST) beam transport tunnel, Target, Bunker and Instruments. Personnel working in all these geographic areas are protected by modular reliable PPS solutions. The safety system enforces access controls, radiation monitoring, beam destination control, and application of critical device inhibit upon detection of abnormal condition. It uses well-documented processes, Common Industrial Protocol (CIP) safety, pulsed test, and redundancy to achieve the desired Safety Integrity Level (SIL). This paper gives an architectural overview of the STS PPS and a detailed safety plan for the SNS facility, addressing safety solutions and human factors.

Michaelides, Tommy [ORNL] (ORCID:0000000190499869)↗

Shining a Light on Some Fundamental Research Opportunities in Semiconductor Photoelectrochemistry

Decades of research in semiconductor photoelectrochemistry have yielded a deep understanding of charge transfer, energetics, and stability at solid−liquid interfaces. Theoretical frameworks developed by Gerischer and contemporaries, together with extensive experimental validation, have clarified the key principles affecting the interfacial kinetics and energetics of semiconductor photoelectrodes. Nevertheless, significant opportunities remain for advances in fundamental understanding of semiconductor photoelectrochemistry. Exciting opportunities include exploiting advances in theory, synthesis, and instrumentation to determine the chemical identity and reactivity of surface states; exerting control of band-edge energetics through molecular-level surface modification processes; and systematically improving emerging photoelectrode protection strategies to enable long-term photoelectrode operation under both oxidative and reductive conditions. Advanced morphologies, such as nanowire and microwire arrays, present new pathways to combine efficient light absorption with effective charge collection and catalyst integration. Unique light−matter interactions during photoelectrochemical deposition of p-type semiconductors readily allow preparation at scale of complex 3D morphologies that are difficult, if not impossible, to access by other methods. Continued exploration of these avenues will expand the fundamental understanding of semiconductor−liquid interfaces and could additionally advance the realization of efficient, stable, and scalable systems for solar fuel generation and other emerging photoelectrochemical applications.

Bean, Paul J. L. [California Institute of Technolo↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Control of atomic Bose – Einstein condensate with interferometric feedback probing

We consider the problem of decoherence in a Bose – Einstein condensate (BEC) of noninteracting atoms during interferometric probing with a classical monochromatic external field. The condensate is located in one of the arms of the Mach – Zehnder interferometer, while part of the radiation from the interferometer output is fed back to the input, thereby closing the coherent feedback loop. A more general setting of the problem is also considered, in which the condensate is located in a system of interferometers ‘nested’ into each other, while part of the output radiation of each of them is also fed back to its input, closing the so-called multiloop feedback. The possibility of effective control of decoherence rates of various matrix elements is shown. The application of feedback of the proposed type to BEC in a double-well potential is investigated. It is found that this feedback allows efficient control of the distribution of atoms between the wells. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Draft Methodology for Cybersecurity Analysis for Adoption of Wireless Technology in Nuclear Power Plants

The report is delivered as DOE-NE Cybersecurity Program Milestone M2CT-22IN1104014-Industry cybersecurity guidance adoption status. The milestone is specifically to document the process and the status of the efforts towards developing guidance in support of industry’s adoption of wireless communication technologies. To transform the operation of nuclear power plants, including domestic light-water reactors, advanced reactors, microreactors, and fission battery, for grid and non-grid applications, secure and resilient wireless capabilities are required. In addition, to realize new operational concepts such as autonomous operation and remote monitoring, advanced sensor, and instrumentation, wireless technology is essential. However, industry implementation is low, and there is no technical basis for how to understand and address potential risks for wireless communications for critical plant functions. A methodology with a technical basis for implementing secure wireless communication is crucial. This wireless adoption methodology is intended to assist a licensee in identifying an appropriate technological approach for securing wireless communications in nuclear power plant. However, this methodology does not provide guidance for addressing wireless design criteria or for addressing all the cybersecurity commitments in licensees’ cybersecurity plans (CSPs) including addressing security impact analysis that a licensee must perform before an update to a Critical Digital Asset (CDA). This methodology guides a licensee through a process of evaluating a proposed wireless implementation and drafting a plant change notification for an example use case. The example is a generic/nonproprietary version of the first test case of the methodology, which, if successfully implemented, is part of the consideration for protecting other functions’ use of wireless in a cybersecure manner.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Real Time, In-line Monitoring of Hanford Tank Wastes - Year 1 Report

The team comprised of students, postdocs, early, mid and senior career scientists from Los Alamos National Laboratory, Savanah River National Laboratory, Georgia Tech and Florida International University, with the guidance of H2C, is developing a suite of in-line instruments for the Hanford high level waste (HLW) and low active waste (LAW) processes to provide near-real-time analysis of waste form physical properties and composition. The work builds on results from the recent DOE-ORP, EM Technology Development and other projects that demonstrated promise for the use of real-time in-line monitoring (RTIM) to measure chemical compositions of slurries of up to 20 weight % solids. The goal is for this instrument suite is to substantially reduce the need for sampling for process control. Sample waste, exposure associated with sample analysis, and the demand for an external laboratory facility would be greatly reduced. The throughput of waste treatment systems would be improved by elimination of the downtime caused by waiting for sample results. This translates into reduced process storage as process knowledge will be continuously updated in near-real-time. These breakthrough technologies would significantly reduce the life cycle cost and accelerate the schedule for the Hanford tank waste mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fact Sheet - Long-length Scintillating Fibers for Radiation Detection

As the world looks to underground geological repositories for storing nuclear waste, technologies to safeguard the material are needed. An example of a project that developed a new technology is Tripwire. Tripwire proposes a multi-sensor system approach for geological spent nuclear fuel repositories that relies of radiation, vibration, and electromagnetic detection. Tripwire was developed by the Applied Radiation Measurements and Systems (ARMS) group at INL and sponsored by the National Nuclear Security Administration (NNSA). The ARMS group performs research and development, testing and evaluation, operational support, and training focused on applied ionizing radiation detection and measurement. Application areas include nuclear engineering for advanced reactors and fuel cycle operations, nuclear nonproliferation, nuclear counterproliferation, nuclear forensics, and arms control and disarmament.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗