Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A Baseline Load Schedule for the Manual Calibration of a Force Balance

A baseline load schedule for the manual calibration of a force balance was developed that takes current capabilities at the NASA Ames Balance Calibration Laboratory into account. The load schedule consists of 18 load series with a total of 194 data points. It was designed to satisfy six requirements: (i) positive and negative loadings should be applied for each load component; (ii) at least three loadings should be applied between 0 % and 100 % load capacity; (iii) normal and side force loadings should be applied at the forward gage location, the aft gage location, and the balance moment center; (iv) the balance should be used in UP and DOWN orientation to get axial force loadings; (v) the constant normal and side force approaches should be used to get the rolling moment loadings; (vi) rolling moment loadings should be obtained for 0, 90, 180, and 270 degrees balance orientation. Three different approaches are also reviewed that may be used to independently estimate the natural zeros of the balance. These three approaches provide gage output differences that may be used to estimate the weight of both the metric and non-metric part of the balance. Manual calibration data of NASA s MK29A balance and machine calibration data of NASA s MC60D balance are used to illustrate and evaluate different aspects of the proposed baseline load schedule design.

Ulbrich, N.↗

Long Term Displacement Data of Woven Fabric Webbings Under Constant Load for Inflatable Structures

Inflatable modules for space applications offer weight and launch volume savings relative to current metallic modules. Limited data exist on the creep behavior of the restraint layer of inflatable modules. Long-term displacement and strain data of two high strength woven fabric webbings, Kevlar and Vectran, under constant load is presented. The creep behavior of webbings is required by designers to help determine service life parameters of inflatable modules. Four groups of different webbings with different loads were defined for this study. Group 1 consisted of 4K Kevlar webbings loaded to 33% ultimate tensile strength and 6K Vectran webbings loaded to 27% ultimate tensile strength, group 2 consisted of 6K Kevlar webbings loaded to 40% and 43% ultimate tensile strength, and 6K Vectran webbings loaded to 50% ultimate tensile strength, group 3 consisted of 6K Kevlar webbings loaded to 52% ultimate tensile strength and 6K Vectran webbings loaded to 60% ultimate tensile strength, and group 4 consisted of 12.5K Kevlar webbings loaded to 22% ultimate tensile strength, and 12.5K Vectran webbings loaded to 22% ultimate tensile strength. The uniquely designed test facility, hardware, displacement measuring devices, and test data are presented. Test data indicate that immediately after loading all webbings stretch an inch or more, however as time increases displacement values significantly decrease to fall within a range of several hundredth of an inch over the remainder of test period. Webbings in group 1 exhibit near constant displacements and strains over a 17-month period. Data acquisition was suspended after the 17th month, however webbings continue to sustain load without any local webbing damage as of the 21st month of testing. Webbings in group 2 exhibit a combination of initial constant displacement and subsequent increases in displacement rates over a 16-month period. Webbings in group 3 exhibit steady increases in displacement rates leading to webbing failure over a 3-month period. Five of six webbings experienced local damage and subsequent failure in group 3. Data from group 4 indicates increasing webbing displacements over a 7-month period. All webbings in groups 1, 2, and 4 remain suspended without any local damage as of the writing of this paper. Variations in facility temperatures over test period seem to have had limited effect on long-term webbing displacement data.

Kenner, Winfred S.↗

Process Control Approach to Implement High Waste Loading Glass Formulations for Hanford Low Activity Waste Vitrification - 18435

Acceptable glass formulations for vitrification of Hanford low activity waste (LAW) at The Hanford Tank Waste Treatment and Immobilization Plant (WTP) must meet a variety of product quality, processability, and waste loading requirements. The glass formulation development work underpinning the WTP baseline LAW glasses was captured in a vitrification process control approach developed by the Vitreous State Laboratory (VSL) and Atkins Energy Federal EPC, Inc. that permits the calculation of the glass formulation required for each particular batch of LAW delivered to the LAW vitrification facility. Since that time, we have developed a wide range of glass formulations that achieve considerably higher waste loadings and which therefore are more economically attractive in terms of reduced amounts of glass produced and decreased time for treatment. That work was done in support of the Department of Energy's Office of River Protection program that is examining options to optimize the LAW facility and LAW glass waste form. Implementation of these high waste loading formulations at the WTP requires the development of a new LAW vitrification process control algorithm, which is the subject of this paper. Waste loadings in LAW glasses are typically limited by either the alkali loading for LAW with low sulfate content or the SO{sub 3} loading for LAW with high sulfate content. In the former case, waste loadings are limited by refractory corrosion and glass corrosion on the vapor hydration test (VHT) and product consistency test (PCT), all of which tend to increase with higher alkali concentrations. In the latter case, waste loadings are limited by the formation of a molten sulfate phase in the melter, which has deleterious effects. The LAW vitrification process control strategy must mitigate these effects while optimizing waste loadings. Given the composition of any LAW stream, the new LAW vitrification process control algorithm permits the calculation of a suitable high waste loading glass composition and the required glass forming additives such that all processing, waste loading, and product quality requirements are met. This algorithm was developed from data for a large number of glasses that were formulated, and characterized with respect to a variety of properties affecting processability and product quality; many of these formulations were also subjected to melter testing to verify acceptable processing characteristics, processing rates, and the absence of secondary sulfate phase formation. This paper describes the development of the present algorithm, comparisons to the present lower waste loading baseline WTP process control approach, and plans for further development and testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Differential Peptide Loading on Tandem Mass Tag-Based Proteomic and Phosphoproteomic Data Quality

Global and phosphoproteome profiling has demonstrated great utility for the analysis of clinical specimens. One major barrier to the broad clinical application of proteomic profiling is the large amount of biological material required, particularly for phosphoproteomics—currently on the order of 25 mg wet tissue weight, depending on tissue type. For hematopoietic cancers such as acute myeloid leukemia (AML), the sample requirement is in excess of 10 million (1E7) peripheral blood mononuclear cells (PBMCs). Throughout the course of a prospective study, this requirement will certainly exceed what is obtainable from many of the individual patients/timepoints. For this reason, we were interested in examining the impact of differential peptide loading across multiplex channels on proteomic data quality. Methods: To achieve this, we tested a range of channel loading amounts (20, 40, 100, 200, and 400 µg of tryptic peptides, or approximately the material obtainable from 5E5, 1E6, 2.5E6, 5E6, and 1E7 AML patient cells) to assess proteome coverage, quantification reproducibility and accuracy in experiments utilizing isobaric tandem mass tag (TMT) labeling. As expected, we found that fewer missing values are observed in TMT channels with higher peptide loading amounts compared to those with lower loading. Moreover, channels with lower loading amounts have greater quantitative variability than channels with higher loading amounts. Statistical analysis of the differences in means among the five loading groups showed that the 20 µg loading group was significantly different from the 400 µg loading group. However, no significant differences were detected among the 40, 100, 200 and 400 µg loading groups. Conclusions: These assessment data demonstrate the practical limits of loading differential quantities of peptides across channels in TMT multiplexes, and provide a basis for designing the optimal clinical proteomics study when specimen quantities are limited.

59 BASIC BIOLOGICAL SCIENCES↗

Data-Driven Distribution System Load Modeling for Quasi-Static Time-Series Simulation

This paper presents a data-driven distribution system load modeling methodology targeting quasi-static time-series (QSTS) simulation. The proposed methodology is appropriate for modeling down to the level of the customer transformer, and it has three main features: 1) both load pattern diversity and intra-second load variability are considered, 2) the load profiles can be populated for multiple nodes on a circuit in such a way that the diversity factor of the feeder can be defined and tuned, and 3) the load aggregation method can be used to populate the profiles for different nodes at various load aggregation levels. Furthermore, as the foundation of the modeling methodology, variability and diversity libraries have been established based on high-resolution load data collected on customer transformers from real utility feeders. The proposed modeling methodology has been used to build load data sets for both the IEEE 123-bus feeder model and a realistic utility feeder model. The QSTS simulation results on the two evaluation feeders have demonstrated that the load data sets established from the proposed modeling methodology can effectively capture the load impact on feeder operations. For the realistic utility feeder, the effectiveness of the proposed methodology has also been validated by comparing the voltage characteristics of the feeder with modeled loads and the voltage characteristics of realistic voltage data from the same feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enriching Load Data Using Micro-PMUs and Smart Meters

In modern distribution systems, load uncertainty can be fully captured by micro-PMUs, which can record high-resolution data; however, in practice, micro-PMUs are installed at limited locations in distribution networks due to budgetary constraints. In contrast, smart meters are widely deployed but can only measure relatively low-resolution energy consumption, which cannot sufficiently reflect the actual instantaneous load volatility within each sampling interval. In this paper, we have proposed a novel approach for enriching load data for service transformers that only have low-resolution smart meters. The key to our approach is to statistically recover the high-resolution load data, which is masked by the low-resolution data, using trained probabilistic models of service transformers that have both high- and low-resolution data sources, i.e., micro-PMUs and smart meters. The overall framework consists of two steps: first, for the transformers with micro-PMUs, a Gaussian Process is leveraged to capture the relationship between the maximum/minimum load and average load within each low-resolution sampling interval of smart meters; a Markov chain model is employed to characterize the transition probability of known high-resolution load. Next, the trained models are used as teachers for the transformers with only smart meters to decompose known low-resolution load data into targeted high-resolution load data. The enriched data can recover instantaneous load uncertainty and significantly enhance distribution system observability and situational awareness. Here, we have verified the proposed approach using real high- and low-resolution load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Procedures for Calculating Residential Dehumidification Loads

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

47 OTHER INSTRUMENTATION↗

Spinning Reserve From Hotel Load Response: Initial Progress

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VOLTTRON-Based System for Providing Ancillary Services with Residential Building Loads

Ancillary services entail controlled modulation of building equipment to maintain a stable balance of generation and load in the power system. Ancillary services include frequency regulation and contingency reserves, whose acting time ranges from several seconds to several minutes. Many pilot studies have been implemented to use industrial loads to provide ancillary services, and some have explored services from commercial building loads or electric vehicle charging loads. Residential loads, such as space conditioning and water heating, represent a largely untapped resource for providing ancillary services. The residential building sector accounts for a significant fraction of the total electricity use in the United States. Many loads in residential buildings are flexible and could potentially be curtailed or shifted at the request of the grid. However, there are many barriers that prevent residential loads being widely used for ancillary services. One of the major technical barriers is the lack of communication capabilities between end-use devices and the grid. End-use devices need to be able to receive the automatic generation control (AGC) signal from the grid operator and supply certain types of telemetry to verify response. With the advance of consumer electronics, communication-enabled, or 'connected,' residential equipment has emerged to overcome the communication barrier. However, these end-use devices have introduced a new interoperability challenge due to the existence of numerous standards and communication protocols among different end devices. In this paper, we present a VOLTTRON-based system that overcomes these technical challenges and provides ancillary services with residential loads. VOLTTRON is an open-source control and sensing platform for building energy management, facilitating interoperability solutions for end devices. We have developed drivers to communicate and control different types of end devices through standard-based interfaces, manufacturer-provided application programming interfaces, and proprietary communication interfaces. We document the ability to manage nine appliances, using four different standards or proprietary communication methods. A hardware-in-the-loop test was performed in a laboratory environment where the loads of a laboratory home and a large number of simulated homes are controlled by an aggregator. Upon receipt of an AGC signal, the VOLTTRON home energy management system (HEMS) of the laboratory home adjusts the end-device controls based on the comfort criteria set by the end users and sends telemetry to the aggregator to verify response. The aggregator then sends the AGC signal to other simulated homes in attempts to match the utility request as closely as possible. Frequency regulation is generally considered a higher value service than other ancillary services but it is also more challenging due to the constraint of short response time. A frequency regulation use case has been implemented with the regulation signals sent every 10 seconds. Experimental results indicate that the VOLTTRON-controlled residential loads are able to be controlled with sufficient fidelity to enable an aggregator to meet frequency regulation requirements. Future work is warranted, such as understanding the impact of this type of control on equipment life, and market requirements needed to open up residential loads to ancillary service aggregators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Wind Loading on CSP Collectors Caused by Turbulent Wind Fluctuations: Insights from a 2-Year Field Campaign

Concentrating Solar Power (CSP) is a promising solar technology for electricity generation with thermal energy storage and with the additional benefit of industrial heat production. Wind loading on CSP collector structures, such as parabolic troughs or heliostats, is one of the primary drivers of their structural design costs. In particular, dynamic wind loading is a major source of uncertainty in the collector design process, which heavily relies on wind tunnel testing. In the field, the turbulent nature of the incoming wind creates fluctuating loads (support structure loads and resulting mirror deflections) on the collectors, with impacts on fatigue lifetime and optical performance. As is well known, wind tunnel tests cannot entirely reproduce the complex turbulent wind conditions typically observed at full-scale plants. To shed light on this topic, NREL initiated a field campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs. We use the published 2-year dataset of high-resolution combined wind and structural loads measurements [1] to characterize the dynamic structural wind response. For quantifying dynamic wind loading, we apply the concept of admittance functions, which are spectral transfer functions that couple the turbulent wind to resulting structural loads (aerodynamic admittance), and to the structural response (mechanical admittance). In practice, aerodynamic admittance describes which turbulent eddy sizes are effective in creating structural loads. The mechanical admittance describes in which frequency ranges these loads are reinforced or dampened by the structure. While these functions are an established concept in civil engineering, their recent application to a single full-scale heliostat [2] proved their broader applicability to CSP collectors. Here, we present a characterization of admittance functions for full-scale parabolic trough collectors and show how wind characteristics (mean wind speed and direction, turbulent kinetic energy, turbulent length scales), the sun-tracking trough angle, and row position alter the admittance functions. Further, we study to which extent the admittance functions are universal for a specific trough geometry and how our findings compare to reported heliostat results. References [1] https://data.openei.org/submissions/5938. [2] Blume, K., Roger, M., and Pitz-Paal, R. 2023b. "Simplified analytical model to describe wind loads and wind-induced tracking deviations of heliostats." Solar Energy, 256, 96-109. https://doi.org/10.1016/j.solener.2023.03.055.

admittance functions↗

Impact of Pt loading methods over mesoporous-assembled TiO{sub 2}–ZrO{sub 2} mixed oxide nanocrystal on photocatalytic dye-sensitized H{sub 2} production activity

Graphical abstract: The Pt loading on the synthesized mesoporous-assembled 0.95TiO{sub 2}–0.05ZrO{sub 2} mixed oxide nanocrystal photocatalyst was comparatively investigated by two methods: single-step sol–gel (SSSG) and photochemical deposition (PCD). The Pt loading by the PCD method was found to be superior to that by the SSSG method in enhancing photocatalytic sensitized hydrogen production under visible light irradiation. The Pt loading amount and PCD conditions, i.e. light irradiation time and light intensity, also had a strong effect on the photocatalytic hydrogen production activity. Highlights: ► Pt-loaded mesoporous-assembled 0.95TiO{sub 2}–0.05ZrO{sub 2} nanocrystals were synthesized. ► Pt loading was performed by single-step sol–gel and photochemical deposition. ► Pt loading by photochemical deposition more enhanced photocatalytic H{sub 2} production. ► Pt loading amount and photochemical deposition conditions were optimized. -- Abstract: In this work, the photocatalytic water splitting under visible light irradiation for hydrogen production was investigated by using Eosin Y-sensitized Pt-loaded mesoporous-assembled TiO{sub 2}–ZrO{sub 2} mixed oxide nanocrystal photocatalysts. The mesoporous-assembled TiO{sub 2}–ZrO{sub 2} mixed oxide with the TiO{sub 2}-to-ZrO{sub 2} molar ratio of 95:5 (i.e. 0.95TiO{sub 2}–0.05ZrO{sub 2}) was synthesized by using a sol–gel process with the aid of a structure-directing surfactant. The Pt loading was comparatively performed via two different effective methods: single-step sol–gel (SSSG) and photochemical deposition (PCD). The synthesized photocatalysts were methodically characterized by N{sub 2} adsorption–desorption, XRD, UV–visible spectroscopy, SEM–EDX, TEM–EDX, TPR, and H{sub 2} chemisorption analyses. The results revealed that the Pt loading by the PCD method greatly enhanced the photocatalytic hydrogen production activity of the synthesized mesoporous-assembled 0.95TiO{sub 2}–0.05ZrO{sub 2} mixed oxide photocatalyst more than that by the SSSG method. The optimum Pt loading by the PCD method was experimentally observed at 0.5 wt.%, which was well associated with the maximum Pt dispersion. In addition, the PCD conditions, i.e. UV light irradiation time and UV light intensity, were investigated and optimized to be 2 h and 44 W, respectively.

36 MATERIALS SCIENCE↗

Modular high temperature gas reactor core modeling with RELAP5-3D/PHISICS – Optimization schemes for load following

The objective of this study is to develop a 3D/NK model to study the load following operation of a Modular High-Temperature Gas-Cooled Reactor (MHTGR). The selected design is the 350 MW prismatic, graphite moderated, helium cooled thermal reactor based on the MHTGR-350 transient benchmark led by the High-Temperature Gas-Cooled Reactor (HTGR) Methods Core Simulation Group at Idaho National Laboratory (INL) in the framework of the Organization for Economic Cooperation and Development Nuclear Energy Agency (OECD/NEA). This kind of reactor usually reacts very slowly to the perturbation of the core parameters due to the large amount of graphite in the core. This kind of behavior promotes the reactor stability but on the other hand limits the reactor load-following operability. Recently advances in gas reactor designs have made load-following in gas reactors a feasible and achievable goal. Modern nuclear reactors (such as the MHTGR-350) are designed to withstand the structural stresses associated with load-following. Operating the reactor in load-following mode will inevitably reduce the load factor. Although a higher load factor means more revenue and the best usage of the fuel, following the variable energy demand will increase the maximum achievable fraction of generated nuclear power, being no more limited to the base load power generation. In general, if low impact on material aging and the safe operability are demonstrated the plant economics will be minimally affected. In order to ensure that the system can be safely operated in a load-following mode an extensively study has been carried out. Some tests with linear coolant mass flow rate change demonstrated that the reactor behavior is suitable for operation in load following mode. This assumption has been confirmed by a 4 days load following transient test in which the reactor supplied the requested power with a negligible error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of particle loading and phase coupling on gas–solid flow dynamics: A case study of a two-phase, gas–solid flow in an annular pipe

The present study is devoted to a two-phase, gas–solid flow in an annular pipe (hollow cylinder) at an elevated pressure of 15 bars and moderate Reynolds number of circa 6000. The influence of the particle loading, the interaction between the phases, and turbulence dispersion on the flow dynamics is systematically studied by means of computational fluid dynamics simulations, employing the Ansys FLUENT commercial package. The cases with a particle volumetric fraction of 1.2% are referred to as “high particle loading,” and those with 0.13% are denoted as “low particle loading.” The following cases are investigated: (1) pure gas flow; (2) low particle loading two-phase flow with one-way coupling and with turbulence dispersion; (3) low particle loading two-phase flow with two-way coupling but without turbulence dispersion; (4) low particle loading two-phase flow with two-way coupling and with turbulence dispersion; (5) high particle loading two-phase flow with one-way coupling and with turbulence dispersion; (6) high particle loading two-phase flow with two-way coupling but without turbulence dispersion; and (7) high particle loading two-phase flow with two-way coupling and with turbulence dispersion. Additionally, the boundary layer is found to grow without fluctuations of the turbulent kinetic energy (TKE) for cases 1, 2, and 5. For case 4, the TKE fluctuations have been identified, although they appear to be less substantial than those in cases 6 and 7. The authors attribute the semi-chaotic nature of the TKE fluctuations to the particle loading and two-way coupling. In addition, the onset and development of the flow instability have been observed at a random axial distance in cases 4, 6, and 7. Such instability is also attributed to the two-way coupling with turbulence dispersion in the flow. It is concluded that the particle loading, one-way, or two-way coupling between the phases, and the turbulence dispersion models significantly influence the development of the flow dynamics with the same inlet and boundary conditions. Consequently, it is not a trivial question, which result a user should trust. The present computational results inspire to perform verification as well as experimental validation of the simulations, so the simulation results can subsequently be used with confidence for design analysis.

42 ENGINEERING↗

Wind Energy Management System Integration Project Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation) and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. In order to improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively, by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. In this report, a new methodology to predict the uncertainty ranges for the required balancing capacity, ramping capability and ramp duration is presented. Uncertainties created by system load forecast errors, wind and solar forecast errors, generation forced outages are taken into account. The uncertainty ranges are evaluated for different confidence levels of having the actual generation requirements within the corresponding limits. The methodology helps to identify system balancing reserve requirement based on a desired system performance levels, identify system “breaking points”, where the generation system becomes unable to follow the generation requirement curve with the user-specified probability level, and determine the time remaining to these potential events. The approach includes three stages: statistical and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence intervals. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis incorporating all sources of uncertainty and parameters of a continuous (wind forecast and load forecast errors) and discrete (forced generator outages and failures to start up) nature. Preliminary simulations using California Independent System Operator (California ISO) real life data have shown the effectiveness of the proposed approach. A tool developed based on the new methodology described in this report will be integrated with the California ISO systems. Contractual work is currently in place to integrate the tool with the AREVA EMS system.

17 WIND ENERGY↗

Comparison of Machine Learning-Based Predictive Models of the Nutrient Loads Delivered from the Mississippi/Atchafalaya River Basin to the Gulf of Mexico

Predicting nutrient loads is essential to understanding and managing one of the environmental issues faced by the northern Gulf of Mexico hypoxic zone, which poses a severe threat to the Gulf’s healthy ecosystem and economy. The development of hypoxia in the Gulf of Mexico is strongly associated with the eutrophication process initiated by excessive nutrient loads. Due to the complexities in the excessive nutrient loads to the Gulf of Mexico, it is challenging to understand and predict the underlying temporal variation of nutrient loads. The study was aimed at identifying an optimal predictive machine learning model to capture and predict nonlinear behavior of the nutrient loads delivered from the Mississippi/Atchafalaya River Basin (MARB) to the Gulf of Mexico. For this purpose, monthly nutrient loads (N and P) in tons were collected from US Geological Survey (USGS) monitoring station 07373420 from 1980 to 2020. Machine learning models—including autoregressive integrated moving average (ARIMA), gaussian process regression (GPR), single-layer multilayer perceptron (MLP), and a long short-term memory (LSTM) with the single hidden layer—were developed to predict the monthly nutrient loads, and model performances were evaluated by standard assessment metrics—Root Mean Square Error (RMSE) and Correlation Coefficient (R). The residuals of predictive models were examined by the Durbin–Watson statistic. The results showed that MLP and LSTM persistently achieved better accuracy in predicting monthly TN and TP loads compared to GPR and ARIMA. In addition, GPR models achieved slightly better test RMSE score than ARIMA models while their correlation coefficients are much lower than ARIMA models. Moreover, MLP performed slightly better than LSTM in predicting monthly TP loads while LSTM slightly outperformed for TN loads. Furthermore, it was found that the optimizer and number of inputs didn’t show effects on the LSTM performance while they exhibited impacts on MLP outcomes. This study explores the capability of machine learning models to accurately predict nonlinearly fluctuating nutrient loads delivered to the Gulf of Mexico. Further efforts focus on improving the accuracy of forecasting using hybrid models which combine several machine learning models with superior predictive performance for nutrient fluxes throughout the MARB.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity analysis of numerical modeling input parameters on floating offshore wind turbine loads

Abstract. Floating wind turbines must withstand a unique and challenging set of loads from the wind and ocean environment. To de-risk development, accurate predictions of these loads are necessary. Uncertainty in modeling predictions leads to larger required safety factors, increasing project costs and the levelized cost of energy. Complex aero-hydro-elastic modeling tools use many input parameters to represent the wind, waves, current, aerodynamic loads, hydrodynamic loads, and structural properties. It is helpful to understand which of these parameters ultimately drives a design. In this work, an ultimate and fatigue-proxy load sensitivity analysis was performed with 35 different input parameters, using an elementary effects approach to identify the most influential parameters for a case study involving the National Renewable Energy Laboratory (NREL) 5 MW baseline wind turbine atop the OC4-DeepCwind semisubmersible during normal operation. The importance of each parameter was evaluated using 14 response quantities of interest across three operational wind speed conditions. The study concludes that turbulent wind velocity standard deviation is the parameter with the strongest sensitivity; this value is important not just for turbine loads, but also for the global system response. The system center of mass in the wind direction is found to have the highest impact on the system rotation and tower loads. The current velocity is found to be the most dominating parameter for the system global motion and consequently the mooring loads. All tested wind turbulence parameters in addition to the standard deviation are also found to be influential. Wave characteristics are influential for some fatigue-proxy loading but do not significantly impact the extreme ultimate loads in these operational load cases. The required number of random seeds for stochastic environmental conditions is considered to ensure that the sensitivities are due to the input parameters and not due to the seed. The required number of analysis points in the parameter space is identified so that the conclusions represent a global sensitivity. The results are specific to the platform, turbine, and choice of parameter ranges, but the demonstrated approach can be applied widely to guide focus in parameter uncertainty.

17 WIND ENERGY↗

Evaluation of a cost-effective loads approach

A shock spectra/impedance method for loads prediction is used to estimate member loads for the Viking Orbiter, a 7800-lb interplanetary spacecraft that has been designed using transient loads analysis techniques. The transient loads analysis approach leads to a lightweight structure but requires complex and costly analyses. To reduce complexity and cost a shock spectra/impedance method is currently being used to design the Mariner Jupiter Saturn spacecraft. This method has the advantage of using low-cost in-house loads analysis techniques and typically results in more conservative structural loads. The method is evaluated by comparing the increase in Viking member loads to the loads obtained by the transient loads analysis approach. An estimate of the weight penalty incurred by using this method is presented. The paper also compares the calculated flight loads from the transient loads analyses and the shock spectra/impedance method to measured flight data.

Garba, J. A.↗

Evaluation of a cost-effective loads approach

A shock spectra/impedance method for loads predictions is used to estimate member loads for the Viking Orbiter, a 7800-lb interplanetary spacecraft that has been designed using transient loads analysis techniques. The transient loads analysis approach leads to a lightweight structure but requires complex and costly analyses. To reduce complexity and cost, a shock spectra/impedance method is currently being used to design the Mariner Jupiter Saturn spacecraft. This method has the advantage of using low-cost in-house loads analysis techniques and typically results in more conservative structural loads. The method is evaluated by comparing the increase in Viking member loads to the loads obtained by the transient loads analysis approach. An estimate of the weight penalty incurred by using this method is presented. The paper also compares the calculated flight loads from the transient loads analyses and the shock spectra/impedance method to measured flight data.

Garba, J. A.↗