Launch Load Resistant Spacecraft Mechanism Bearings Made From NiTi Superelastic Intermetallic Materials

Compared to conventional bearing materials (tool steel and ceramics), emerging Superelastic Intermetallic Materials (SIMs), such as 60NiTi, have significantly lower elastic modulus and enhanced strain capability. They are also immune to atmospheric corrosion (rusting). This offers the potential for increased resilience and superior ability to withstand static indentation load without damage. In this paper, the static load capacity of hardened 60NiTi 50mm bore ball-bearing races are measured to correlate existing flat-plate indentation load capacity data to an actual bearing geometry through the Hertz stress relations. The results confirmed the validity of using the Hertz stress relations to model 60NiTi contacts; 60NiTi exhibits a static stress capability (3.1GPa) between that of 440C (2.4GPa) and REX20 (3.8GPa) tool steel. When the reduced modulus and extended strain capability are taken into account, 60NiTi is shown to withstand higher loads than other bearing materials. To quantify this effect, a notional space mechanism, a 5kg mass reaction wheel, was modeled with respect to launch load capability when supported on 440C, 60NiTi and REX20 tool steel bearings. For this application, the use of REX20 bearings increased the static load capability of the mechanism by a factor of three while the use of 60NiTi bearings resulted in an order of magnitude improvement compared to the baseline 440C stainless steel bearings.

metals↗

Influence of Mixed Mode I-Mode II Loading on Fatigue Delamination Growth Characteristics of a Graphite Epoxy Tape Laminate

Mixed mode I-mode II interlaminar tests were conducted on IM7/8552 tape laminates using the mixed-mode bending test. Three mixed mode ratios, G(sub II)/G(sub T) = 0.2, 0.5, and 0.8, were considered. Tests were performed at all three mixed-mode ratios under quasi-static and cyclic loading conditions, where the former static tests were used to determine initial loading levels for the latter fatigue tests. Fatigue tests at each mixed-mode ratio were performed at four loading levels, Gmax, equal to 0.5G(sub c), 0.4G(sub c), 0.3G(sub c), and 0.2G(sub c), where G(sub c) is the interlaminar fracture toughness of the corresponding mixed-mode ratio at which a test was performed. All fatigue tests were performed using constant-amplitude load control and delamination growth was automatically documented using compliance solutions obtained from the corresponding quasi-static tests. Static fracture toughness data yielded a mixed-mode delamination criterion that exhibited monotonic increase in Gc with mixed-mode ratio, G(sub II)/G(sub T). Fatigue delamination onset parameters varied monotonically with G(sub II)/G(sub T), which was expected based on the fracture toughness data. Analysis of non-normalized data yielded a monotonic change in Paris law exponent with mode ratio. This was not the case when normalized data were analyzed. Fatigue data normalized by the static R-curve were most affected in specimens tested at G(sub II)/G(sub T)=0.2 (this process has little influence on the other data). In this case, the normalized data yielded a higher delamination growth rate compared to the raw data for a given loading level. Overall, fiber bridging appeared to be the dominant mechanism, affecting delamination growth rates in specimens tested at different load levels and differing mixed-mode ratios.

Ratcliffe, James G.↗

Launch Load Resistant Spacecraft Mechanism Bearings Made From NiTi Superelastic Intermetallic Materials

Compared to conventional bearing materials (tool steel and ceramics), emerging Superelastic Intermetallic Materials (SIMs), such as 60NiTi, have significantly lower elastic modulus and enhanced strain capability. They are also immune to atmospheric corrosion (rusting). This offers the potential for increased resilience and superior ability to withstand static indentation load without damage. In this paper, the static load capacity of hardened 60NiTi 50mm bore ball-bearing races are measured to correlate existing flat-plate indentation load capacity data to an actual bearing geometry through the Hertz stress relations. The results confirmed the validity of using the Hertz stress relations to model 60NiTi contacts; 60NiTi exhibits a static stress capability (3.1GPa) between that of 440C (2.4GPa) and REX20 (3.8GPa) tool steel. When the reduced modulus and extended strain capability are taken into account, 60NiTi is shown to withstand higher loads than other bearing materials. To quantify this effect, a notional space mechanism, a 5kg mass reaction wheel, was modeled with respect to launch load capability when supported on 440C, 60NiTi and REX20 tool steel bearings. For this application, the use of REX20 bearings increased the static load capability of the mechanism by a factor of three while the use of 60NiTi bearings resulted in an order of magnitude improvement compared to the baseline 440C stainless steel bearings.

bearings↗

Launch Load Resistant Spacecraft Mechanism Bearings Made From NiTi Superelastic Intermetallic Materials

Compared to conventional bearing materials (tool steel and ceramics), emerging Superelastic Intermetallic Materials (SIMs), such as 60NiTi, have significantly lower elastic modulus and enhanced strain capability. They are also immune to atmospheric corrosion (rusting). This offers the potential for increased resilience and superior ability to withstand static indentation load without damage. In this paper, the static load capacity of hardened 60NiTi 50-mm-bore ball bearing races are measured to correlate existing flat-plate indentation load capacity data to an actual bearing geometry through the Hertz stress relations. The results confirmed the validity of using the Hertz stress relations to model 60NiTi contacts; 60NiTi exhibits a static stress capability (approximately 3.1 GPa) between that of 440C (2.4 GPa) and REX20 (3.8 GPa) tool steel. When the reduced modulus and extended strain capability are taken into account, 60NiTi is shown to withstand higher loads than other bearing materials. To quantify this effect, a notional space mechanism, a 5-kg mass reaction wheel, was modeled with respect to launch load capability when supported on standard (catalogue geometry) design 440C; 60NiTi and REX20 tool steel bearings. For this application, the use of REX20 bearings increased the static load capability of the mechanism by a factor of three while the use of 60NiTi bearings resulted in an order of magnitude improvement compared to the baseline 440C stainless steel bearings

DellaCorte, Christopher↗

Moving Aerospace Structural Design Practice to a Load and Resistance Factor Approach

Aerospace structures are traditionally designed using the factor of safety (FOS) approach. The limit load on the structure is determined and the structure is then designed for FOS times the limit load - the ultimate load. Probabilistic approaches utilize distributions for loads and strengths. Failures are predicted to occur in the region of intersection of the two distributions. The load and resistance factor design (LRFD) approach judiciously combines these two approaches by intensive calibration studies on loads and strength to result in structures that are efficient and reliable. This paper discusses these three approaches.

Larsen, Curtis E.↗

Detection of Damage During Quasi-Static Loading of a Single Stringer Panel Using Passive Thermography and Acoustic Emission

The purpose of this paper is to describe the methodology of measuring damage onset and growth in a composite structure during quasi-static loading using passive thermography and acoustic emission. The early detection and measurement of damage progression is important to understand failure modes. A single stringer panel was subjected to quasi-static loading to induce deformation which resulted in the formation of damage between the stiffener flange and skin. The loading was stopped when damage growth was detected. Passive thermography and acoustic emission were used to detect damage in real-time as a function of the applied load. Of particular interest are the small transient thermographic signals resulting from damage formation which can be challenging to detect, as compared to the persistent passive thermography indications of cyclic fatigue loading. We describe a custom developed thermal inspection system for detection of composite damage during quasi-static loading. The thermal results are compared to a two-dimensional multi-layered thermal simulation based on the quadrupole method. Acoustic emission is used to further characterize the damage by comparing the acoustic emission events with the thermal imagery. Results are compared to ultrasonic measurements to document the damage through-the-thickness.

Zalameda, Joseph N.↗

Adaptive Load Control of Flexible Aircraft Wings Using Fiber Optic Sensing

Over the past century aircraft wing design has transformed from the morphing wing used on the Wright Flyer to rigid wings with little to no shape-tailoring abilities. Modern day wings are designed to fly at a single trim condition and optimized to have a maximum aerodynamic efficiency at only this condition. Shape morphing wings on the other hand have the potential to undergo geometric changes allowing them to adapt to their mission profiles. Several flight demonstrations have been conducted over the decades using morphing-wing technologies. Active wing-twist control was demonstrated on the X-53 Active Aeroelastic Wing (AAW) research project by utilizing multiple leading- and trailing-edge control surfaces. Passive morphing technology has been demonstrated on the Rockwell RPRV-870 Highly Maneuverable Aircraft Technology (HiMAT) aircraft. In the current study, the wings of a small unmanned aerial system (sUAS) were modified to have segmented control surfaces (SCS). The modifications include segmenting the original wing control surfaces (one flap and one aileron per wing) into 44 individual sections, each section having its own independent servo control motor. The wings were also instrumented with a network of over 1800 fiber-optic strain sensors (on four sensing fibers distributed over the top and bottom surfaces of the wing) monitoring the strain response of the wing to aerodynamic loading. The SCS positions were manipulated in real time to modify the spanwise lift distribution of the wings on the sUAS. The change in the structural response of the wings caused by load redistribution was quantified by measuring the bending strains on the upper and lower wing surfaces using an on-board compact fiber-optic strain sensing (cFOSS) system. A feedback controller was developed to control the SCS positions using strain-based shape estimations from the Displacement Transfer Function (DTF). Post-processing of the strain data allowed for the transverse displacement distributions and load distributions to be compared for the conventional and segmented control surface cases using displacements and loads algorithms developed by Richards and Ko at AFRC (refs. 5-10). While the current study focused on the shifting of the spanwise aerodynamic loads as quantified by displacements, future applications for loads or displacement control might include active gust alleviation and flutter suppression.

Pena, Francisco↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

Kenneth J Pederson↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

K. J. Pederson↗

Load Schedule Design Improvements for the Calibration of NASA's Semi-span Balances

Improvements of the load schedule design for the calibration of NASA's semi-span balances are discussed. These improvements became possible after a minor hardware change was made to Calspan's Large Load Rig. This change moves normal and axial force load points 12 inches closer to the balance moment center. Resulting data quality improvements are significant because Calspan's Large Load Rig cannot currently apply forces at the balance moment center of a semi-span balance. Now, the supported set of rolling and yawing moment arms is 28, 38, and 48 inches. Consequently, the new load schedule design better supports expected normal and axial force locations on semi-span models that are tested in the NASA Ames 11-ft Transonic Wind Tunnel. In addition, estimates of the primary sensitivities of the normal force, axial force, rolling moment, and yawing moment have become more accurate as the applied normal and axial forces have moved closer to the balance moment center. Fundamental moment arm range requirements and Calspan's hardware updates are discussed. In addition, calibration and check load analysis results of NASA's ARC30K semi-span balance are presented to illustrate benefits of the hardware changes.

wind tunnel test↗

Statistically Consistent Dispersions of Line Loads to Uncertain Integrated Forces and Moments

This work presents a method to generate line loads that are consistent with integrated force and moment constraints, while also following the statistical distribution underlying known line load data. The motivation for this method is to address a particular problem that can arise during the pre-flight analysis of an ascent vehicle. That problem is constructing separate databases, for line loads and integrated aerodynamic coefficients, that contain different data and thus different amounts of quantified uncertainty. A dispersed line load method is described and applied to a data set generated by 29 computational fluid dynamics simulations at various angles of attack and sideslip. The statistical similarity of the generated line loads to the known data is confirmed by using the Maximum Mean Discrepancy 2-sample test. The promising results from this novel method are compared against results from applying an existing line load adjustment procedure to the same data set. Finally, potential future avenues of research are briefly discussed.

Aaron C. Burkhead↗

Loads and Structural Dynamics Requirements for Spaceflight Hardware

The NASA Exploration Systems Development Mission Directorate requires Crewed Space Systems (CSS) to meet the intent of a set of Engineering Technical Authority (TA) documents called out in HEOMD-003, Crewed Deep Space Systems Human Rating Certification Requirements and Standards for NASA Missions. For the Loads and Dynamics technical discipline, the document invoked by the HEOMD-003 is JSC 65829, Loads and Structural Dynamics Requirements for Spaceflight Hardware. JSC 65829 was originally developed for the NASA Commercial Crew Program as an implementation of NASA STD-5002, Load Analyses of Spacecraft and Payloads, for that Program. Since that time, tailored alternatives to JSC 65829 have been produced for the Gateway, Human Landing System, and Extravehicular Activity and Human Surface Mobility Programs. Experience with those Programs has shown that the reduced set of less-prescriptive requirements in those tailored documents offers an advantage over the set of requirements in JSC 65829 Rev A and is a better fit for the paradigm of NASA procurement of commercially developed systems for crewed spaceflight. Revision B of JSC 65829 has been constructed to align with those tailored documents. The reduction in the number and specificity of requirements is balanced by a new requirement for hardware developers to create and provide a Loads Control Plan which describes how the approaches used to generate design-to loads and dynamic environments and substantiate dynamic model validity satisfy the requirements herein. The Plan will establish an agreement between the hardware developer and the TA for the loads and dynamics discipline and offer an opportunity for reengagement if the Plan changes during development.

Kenneth Schultz↗

Effects of Zoledronate and Mechanical Loading during Simulated Weightlessness on Bone Structure and Mechanical Properties

Space flight modulates bone remodeling to favor bone resorption. Current countermeasures include an anti-resorptive drug class, bisphosphonates (BP), and high-force loading regimens. Does the combination of anti-resorptives and high-force exercise during weightlessness have negative effects on the mechanical and structural properties of bone? In this study, we implemented an integrated model to mimic mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hindlimb unloading (HU). Our working hypothesis is that CL combined with ZOL in the HU model induces additive structural and mechanical changes. Thirty-two C57BL6 mice (male,16 weeks old, n8group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45gkg), or saline vehicle, prior to experiment. The right tibia was axially loaded in vivo, 60xday to 9N in compression, repeated 3xweek during HU. During the application of compression, secant stiffness (SEC), a linear estimate of slope of the force displacement curve from rest (0.5N) to max load (9.0N), was calculated for each cycle once per week. Ex vivo CT was conducted on all subjects. For ex vivo mechanical properties, non-CL left femurs underwent 3-point bending. In the proximal tibial metaphysis, HU decreased, CL increased, and ZOL increased the cancellous bone volume to total volume ratio by -26, +21, and +33, respectively. Similar trends held for trabecular thickness and number. Ex vivo left femur mechanical properties revealed HU decreased stiffness (-37),and ZOL mitigated the HU stiffness losses (+78). Data on the ex vivo Ultimate Force followed similar trends. After 3 weeks, HU decreased in vivo SEC (-16). The combination of CL+HU appeared additive in bone structure and mechanical properties. However, when HU + CL + ZOL were combined, ZOL had no additional effect (p0.05) on in vivo SEC. Structural data followed this trend with ZOL not modulating trabecular thickness in CL + NAHU mice. In summary, our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. Based on these results, we conclude that, at the structural and stiffness level, zoledronate treatment during simulated spaceflight does not impede the skeletal response to axial compression. In contrast to our hypothesis, our data show that zoledronate confers no additional mechanical or structural benefit beyond those gained from cyclical loading.

Mechanical Loading↗

A Universal Threshold for the Assessment of Load and Output Residuals of Strain-Gage Balance Data

A new universal residual threshold for the detection of load and gage output residual outliers of wind tunnel strain{gage balance data was developed. The threshold works with both the Iterative and Non{Iterative Methods that are used in the aerospace testing community to analyze and process balance data. It also supports all known load and gage output formats that are traditionally used to describe balance data. The threshold's definition is based on an empirical electrical constant. First, the constant is used to construct a threshold for the assessment of gage output residuals. Then, the related threshold for the assessment of load residuals is obtained by multiplying the empirical electrical constant with the sum of the absolute values of all first partial derivatives of a given load component. The empirical constant equals 2.5 microV/V for the assessment of balance calibration or check load data residuals. A value of 0.5 microV/V is recommended for the evaluation of repeat point residuals because, by design, the calculation of these residuals removes errors that are associated with the regression analysis of the data itself. Data from a calibration of a six-component force balance is used to illustrate the application of the new threshold definitions to real{world balance calibration data.

wind tunnel balance↗

In-Space Loads Analysis of SLS/Orion

The Space Launch System and Orion spacecraft experience unique load cases during upper stage flight since the Orion must deploy its solar arrays before the upper stage engine fires. The low frequency bending modes of the deployed arrays have the potential to interact with the slosh modes of the upper stage, and with the upper stage flight steady-state accelerations this can induce high loads in the array mechanisms. A time-domain transient response solution is used to evaluate the array mechanism loads, sensitivities are noted, and the final loads are determined to be within the capability of the mechanism. Section loads and accelerations are also recovered and assessed.

SLS↗

In-Space Loads Analysis of SLS/Orion

The Space Launch System and Orion spacecraft experience unique load cases during upper stage flight since the Orion must deploy its solar arrays before the upper stage engine fires. The low frequency bending modes of the deployed arrays have the potential to interact with the slosh modes of the upper stage. In combination with the upper stage flight steady-state accelerations this can induce high loads in the array mechanisms. A time-domain transient response solution is used to evaluate the array mechanism loads, sensitivities are noted, and the final loads are determined to be within the capability of the mechanism. Section loads and accelerations are also recovered and assessed.

SLS↗

The Effects of Off-Axis Loading on the Compression After Impact Strength of Quasi-Isotropic Face Sheet Honeycomb Core Sandwich Structure

This study presents experimental results of compression after impact (CAI) testing of aluminum honeycomb core sandwich structure with face sheets made of co-cured T1100/3960 quasi-isotropic carbon/epoxy when tested at +22.5⁰ and -22.5⁰ with respect to the 0⁰ fibers. In a previous study examining the CAI strengths of honeycomb sandwich structure, it was found that specimens had different CAI strengths, based on a [-45/90/+45/0]s layup, depending on whether they were tested in the 0⁰ direction (face sheet layup of [-45/90/+45/0]s) or 90⁰ direction (face sheet layup of [+45/0/-45/90]s). The CAI strength results showed that the specimens tested in the 90⁰ direction had a 19% drop in CAI strength compared to specimens tested in the 0⁰ direction. This was attributed to the 0⁰ load bearing plies in the 0⁰ direction specimens being “tucked in” at the center of the specimen thus providing more stability against microbuckling. This raised the question as to what CAI strength would specimens tested at +22.5⁰ (face sheet layup of [-22.5/- 67.5/+67.6/+22.5]s) and -22.5⁰ (face sheet layup of [-67.5/+67.5/+22.5/-22.5]s) have compared to specimens tested in the 0⁰ and 90⁰ direction. Results presented in this study show that the specimens loaded at +22.5⁰ and -22.5⁰ have a similar average CAI strength compared to the specimens loaded in the 0⁰ direction. The specimens loaded in the 90⁰ direction exhibit 16% lower average CAI strength. Additional specimens were tested in the +45⁰ direction to put the 0⁰ load bearing fibers on the outside of the specimen to see if this would decrease the strength as has been documented for undamaged strength. These specimens have average CAI strength values between the 0⁰ direction average CAI strength values and the 90⁰ direction average CAI strength values.

Sandwich structure↗

Space Launch System Day of Launch Loads for Artemis I

NASA’s Space Launch System (SLS) was successfully launched on November 16, 2022. During the years leading up to the first flight, Artemis I, a DOLILU (Day of Launch I-Load Update) process was developed to design, verify, and upload the first stage flight trajectory on day-of-launch to ensure a safe flight. The evaluation of integrated vehicle loads is a key component of the DOLILU process. The SLS Artemis I DOL loads project has involved methodology development, software development, software testing and certification, operator training, and simulation and launch support. The resulting DOL process successfully calculated loads for all launch opportunities within the window, with the robust nature of the process contributing to all opportunities being go for loads.