Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Applicable Experiment Selection

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-IP calculations performed to select applicable experiments for validation of 11 MPC-32 DPCs. The companion paper discusses the TSUNAMI-3D calculations used to generate sensitivity data to support the experiment selections discussed here. Experiment selection is based on the sensitivity/uncertainty (S/U) methods used to validate criticality safety calculations of as-loaded DPCs containing pressurized water reactor (PWR) spent nuclear fuel (SNF). This process has been demonstrated and is summarized in this paper. The approach is similar to that used in NUREG/CR-7109, which provides an approach for validation of PWR burnup credit (BUC), including major and minor actinides and major fission products. The premise of S/U-based validation is that applicable experiments—those having a similar bias to a given application system—will have similar sensitivities for each isotope and reaction in the two systems. It is assumed that cross sections with larger uncertainties are more likely to contain data errors which contribute to the bias. The integral index c k thus propagates the system sensitivities with the nuclear covariance data to calculate a correlation coefficient representing the similarity of the two systems. In this work, a c k value of 0.8 or higher is interpreted as identifying an experiment with sufficient similarity for use in validation. This paper presents a brief summary of the characteristics of the 11 MPC-32 DPCs used in the proof of-principle analysis for as-loaded criticality safety calculation validation and an overview of the critical experiment suite with which each of these DPC models was compared. A summary and discussion of c k results is also presented, followed by conclusions and a discussion of future work to be performed for validation of UNF ST&DARDS as-loaded criticality safety calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Evaluation of the SAVY-4000 1 Quart Container at High Heat Loads

The SAVY-4000 Safety Analysis Report (SAR) was published in 2013 which established the design life of the container series through physical testing that meets applicable requirements from DOE M 441.1-1, Nuclear Material Packaging Manual. One critical requirement in DOE M 441.1-1 is to set a maximum heat load for the entire series to ensure that throughout the lifetime of the container, each of the components still performs within manufacture specifications. The original maximum decay heat limit has been defined within the SAVY-4000 SAR, which was accomplished by completing a series of tests that heat loaded the SAVY-4000 series and measured the steady state temperature and graded it against manufacture specifications. The container series is comprised of a corrosion resistant 316L stainless steel containment boundary, ceramic composite filter for the prevention of radiological particulate release and a chemically stable O-ring made of Viton ® . Currently, the SAVY 4000 maximum decay heat load is set at 25 Watts and the heat load expected during normal handling and storage is considered sufficient that the SAVY 4000 container requirements will not be the limiting factor for storage of most common material in use at TA-55, e.g. weapons grade oxide, americium, Pu-238 oxide and encapsulated heat sources. The SAVY 4000 lifetime was originally set as 5 years within the SAVY-4000 SAR, but in July 2019 the lifetime was extended to 15 years through a technical basis justification approved by the Department of Energy (DOE) Los Alamos Field Office. The 25 Watt limit applies to all SAVY 4000 container sizes; 1-quart, 2-quart, 3-quart, 5-quart, 8-quart, 12-quart, 5-gallon, and 10-gallon.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

OC6 Phase Ia Definition Document: Validation of Nonlinear Hydrodynamic Loading on the DeepCwind Semisubmersible

The objective of OC6 Phase I is to investigate the persistent under-prediction (about 20% on average) of the structural loads in the OC5-DeepCwind floating semisubmersible wind system, as observed within the previous OC5 Phase II project. The OC5 results indicate that much of this under-prediction originates from the low-frequency response of the system at the surge/pitch natural frequencies, resulting from nonlinear hydrodynamic loading and/or overprediction of hydrodynamic damping. This work package therefore focuses on better understanding this low-frequency response behavior, the applicability of computational-fluid-dynamics (CFD) models and engineering-level hydrodynamic models for predicting the nonlinear hydrodynamic loading, and the level of uncertainty in the measured response characteristics. To address these objectives, two experimental campaigns were developed and performed in 2017 and 2018 by a sub-group of the OC5 project: Floating test campaign: A simplified OC5-DeepCwind semisubmersible model (no turbine, rigid tower) was moored to three taut-spring lines and subjected to motion decay and wave tests (regular and irregular waves), during which motion amplitudes of the model were measured (see Figure 1a). The purpose of this test campaign was to examine the repeatability of the low-frequency response of the system to wave excitation and determine the level of uncertainty in the response behavior.Constrained test campaign: The same model, but without the tower present, was fixed to a carriage and subjected to towing, forced oscillation and wave tests (regular and irregular waves), during which forces exerted upon the model were measured (see Figure 1b). The purpose of this test campaign was to examine the hydrodynamic loading contributions by separating the wave excitation and radiation forces. Both model test campaigns were performed in the concept basin of the Maritime Research Institute Netherlands (MARIN) in Wageningen, the Netherlands and the first test was within the framework of the MARINET2 project. Both experimental campaigns were examined within Phase Ia of the OC6 project. The purpose of this report is to supply the needed information to participants of the OC6 project to build and simulate the experimental campaigns.

17 WIND ENERGY↗

Load Following Analysis of the Holos-Quad 10MWe Micro-Reactor with Plant Dynamics Code

This report presents the load following analysis of the “Holos-Quad” 10MWe micro-reactor design developed by HolosGen LLC. This analysis is focused on the Holos-Quad micro-reactor ability to match the changing grid demand at 10%/min rate. The control mechanisms for the plant are identified, simulated, and compared. Based on the comparison results, control strategy for load following of the Holos-Quad micro-reactor is developed. The control strategy and load following capabilities are demonstrated in a full-range down-and-up reactor power transient from 100% to 0% and back to 100% load at 10%/min rate. All calculations are carried out with Argonne’s Plant Dynamics Code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Guidelines for Determining the Load Resistance of Thin-Glass Triple-Pane Insulating Glass Unit Configurations

This guideline is intended to provide information relevant to the specification of triple- pane insulating glass (IG) units where the thickness of lite number 2 (center lite) is less than or equal to the thickness of lite numbers 1 and 3. Procedures and charts are presented to determine the load resistance (LR) of common soda-lime glass thicknesses from 0.7 mm (3/128 in.) to 1.8 mm (9/128 in.) exposed to a uniform lateral load of short or long duration, for a 0.008 probability of breakage. Deflection under load, horizontal self-weight deflection, and natural frequency procedures and charts are also included to aide in the selection of glass thickness to meet manufacturing and/or loading criteria determined by the user.

42 ENGINEERING↗

UNF-ST&DARDS Enhancements for RCCA Data in As-loaded Dual Purpose Cask Models

This report summarizes the work performed to enable detailed modeling of rod cluster control assembly (RCCAs) in dual purpose canisters (DPCs) in as-loaded configurations using the Used Nuclear Fuel – Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). The goal of this project was to evaluate the reactivity impact that RCCAs have on k eff of DPCs with pressurized water reactor (PWR) fuel to potentially use the additional margin in future post-closure criticality safety analysis. This preliminary evaluation determined the number of DPCs that currently require compensatory actions prior to emplacement in a repository because of their high reactivity under post-closure criticality scenarios, which could be made acceptable by including the as-loaded RCCAs as specified in the Unified Database (UDB). This report briefly describes the modeling methods currently used within UNF-ST&DARDS and the modifications made to automate inclusion of the as-loaded RCCAs in the DPCs for post-closure criticality calculations for the loss of neutron absorber (NA) scenarios, or NA models. For the Zion site, the loss of basket scenarios, or degraded basket (DB) models, are also included. Discussion is also provided regarding the UDB data compared to available site-specific loading map data for the sites, which are specifically evaluated herein. This report compares the modifications to a similar evaluation for the Zion by site conducted by Walker as an initial validation. After the partial validation, all existing PWR sites with applicable NA models within the UDB were evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling Workloads of a Linear Electromagnetic Code for Load Balancing Matrix Assembly

This report presents our work to model the workloads of a linear electromagnetic application based on the method of moments in the frequency domain to effectively load balance the matrix assembly. This application is particularly challenging to load balance due to its lack of persistent iterative behavior, its operation under tight memory constraint (where the matrix may fill 80% of memory on each node), and the algorithmic complexity of the computational method. This report describes the first step in our work to apply an inspector-executor approach for load balancing workloads where key parameters are exposed during the inspector phase and a pre-trained model is applied to predict relative task weights for the load balancer.

97 MATHEMATICS AND COMPUTING↗

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities

Electricity demand from large load customers such as data centers is projected to grow significantly in the near term. While data centers play an important role in advancing technology innovation and economic growth in the United States, data center energy needs present challenges and opportunities for electricity supply and infrastructure. This technical brief serves as a foundation for the discussion of issues and sharing of perspectives among utilities, regulators, large load customers, and other stakeholders. As utilities and regulators explore rate structures to address growing data center electricity demand, several issues have emerged: -Fair allocation of electricity system costs to large-load customers without unfair shifting of costs to other customers -Appropriate mitigation of the financial risks associated with stranded assets from underutilized utility system investments -Mitigation of operational and resource adequacy risks if electricity demand exceeds supply -Appropriate risk-sharing in commercializing newer electricity technologies such as advanced geothermal, small modular reactors, and long duration energy storage -Accommodating the diverse needs of large-load customers, such as having the option to match electricity consumption with output from carbon-free resources or using onsite generation to provide system capacity The technical brief also identifies key design elements that aim to address these issues and uses leading examples from pending and approved rate structures, agreements, and special contracts to ground the elements in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large Load Impacts to Distribution System Hosting Capacity

This work examined the impact of large loads on utility distribution system models using the Sandia-developed open-source software DREAMS. It was shown that hosting capacity varies with location and changes after any asset is added to, or removed from, a system. Despite the tested models having similar rated voltages and other characteristics, their thermal and voltage constrained hosting capacity varied over 2 MW. The addition of a 3-phase balanced constant power large load with power factor of 1.0 exhibited non-linear reductions to all voltage constrained hosting capacities. The reductions to thermal constrained hosting capacity from a load with similar characteristics was more linear, related to the size of the added load, and did not impact all model buses. Co-located capacitors were shown to accommodate demand that was beyond the baseline voltage constrained hosting capacity limits, however, the costs and benefits from this approach were found to not be 1:1 and required additional available thermal capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OC6 Phase III: Validation of Wind Turbine Aerodynamic Loading During Surge/Pitch Motion

The objective of Phase III of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project was to validate the accuracy of aerodynamic load predictions by offshore wind modeling tools for a floating offshore wind turbine as it experiences large surge-translational and pitch-rotational motion, as would occur during normal operation. The test data considered were generated at Politecnico di Milano – a wind tunnel with a robotic excitation system to emulate wave loading on the wind turbine. Testing was performed using a scaled version of the DTU 10-MW reference model, and motion was prescribed as harmonic oscillations in the surge and pitch directions, independently. A variety of models were examined in the project, performing a three-way validation between engineering-level tools, higher-fidelity tools, and measurement data from two wind tunnel experimental campaigns. The Load Cases (LC) considered in this testing are as follows: LC 1.X - Steady Wind LC 2.X - Unsteady Wind - Surge Motion LC 3.X - Unsteady Wind - Pitch Motion Details on the results of the OC6 Phase III campaign can be found in the following reference: Bergua R., et al. OC6 project Phase III: validation of the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure, Wind Energ. Sci., 8, 465–485, https://doi.org/10.5194/wes-8-465-2023, 2023.

17 WIND ENERGY↗

FOCAL Campaign II/III: Applying Active Hull Controls Using Tuned-mass Dampers/Hull Flexibility and Internal Loads

Campaign II and III of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aimed to generate a dataset enabling the validation of the performance and loads of a scaled hull, with and without structural hull control. The floating platform was subjected to a variety of wave environments and controlled using tuned-mass dampers (TMDs) tuned to two of the systems natural frequencies (Platform Pitch and Tower-bending). The floating platform is fully instrumented to record a variety of parameters in real time such as platform dynamics, accelerations, and loads at different points in the structure. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. This testing was focused only on validation of wave loading, and wind conditions were not considered. As such the platform does not support a working turbine, and instead supports a structure designed to have the same mass properties as the 1:70 IEA 15MW Reference turbine. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Platform Static Offset (TMD off); LC 2.X - Platform Free-decays (TMD off); LC 3.X - Wave Cases (Regular Wave, Irregular Wave, Pink Noise Wave) with and without TMDs active. Detailed properties on the model system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaigns 2 and 3: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine and the VolturnUS-S Hull. UMaine ASCC Report Number 23-56-1183.

17 WIND ENERGY↗

Gaussian Process Regression for Aggregate Baseline Load Forecasting

Demand response (DR) is one of the most effective ways to maintain the reliability and improve the flexibility of power systems. Accurate forecasts of baseline loads are essential for DR programs. In the era of big data, machine learning-based approaches present a unique opportunity for baseline load forecasting. Thus, this paper presents a machine learning-based approach using a relatively less explored algorithm, Gaussian process regression (GPR), to forecast aggregate baseline loads. As such, a dataset was generated using a set of EnergyPlus simulations. Using the generated dataset, a GPR-based forecasting model was developed. In addition, support vector regression (SVR)-, artificial neural network (ANN)-, and averaging-based models were developed as baseline models for comparison. These models were compared in terms of accuracy, simplicity, and integrity. The prediction performance of the models showed that the GPR-based model is more accurate and reliable than the others. Such high performance shows the potential of the GPR in baseline load forecasting. GPR, therefore, can be used for DR applications.

Amasyali, Kadir↗

Geometrically Necessary Dislocation Analysis of Deformation Mechanism for Magnesium under Fatigue Loading at 0 °C

This study focused on the analysis of geometrically necessary dislocation (GND) densities for five selected fine-grained magnesium samples. Among the samples, three were tested under different fatigue-loading conditions at 0 °C, one experienced quasi-static tensile loading at 0 °C, and one represented the as-rolled state. The fatigue-tested samples were chosen according to the relationship between the maximum loading stress of a test and the material’s yield strength. This study provides new insights on the deformation mechanism of fine-grained magnesium at 0 °C. It is observed that the average GND densities were increased by 95~111% for the tested samples when compared with the as-rolled sample. It is especially interesting that there is a significant increase in the average GND density for the sample that experienced the fatigue loading with a low-maximum applied stress, and the maximum applied stress was lower than the material’s yield strength. This observation implies that the grain boundary mediated the dislocation-emission mechanism.

Li, Qizhen↗

An Overview of Electric Vehicle Load Modeling Strategies for Grid Integration Studies

The adoption of electric vehicles (EVs) has emerged as a solution to reduce greenhouse gas emissions in the transportation sector, which has motivated the implementation of public policies to promote their use in several countries. However, the high adoption of EVs poses challenges for the electricity sector, as it would imply an increase in energy demand and possible impacts on the power quality (PQ) of the power grid. Therefore, it is important to conduct EV integration studies in the power grid to determine the amount that can be incorporated without causing problems and identify the areas of the power sector that will require reinforcements. Accurate EV load patterns are required for this type of study that, through mathematical modeling, reflect both the dynamic behavior and the factors that influence the decision to recharge EVs. This article aims to present an overview of EVs, examine the different factors considered in the literature for modeling EV load patterns, and review modeling methods. EV load modeling methods are classified into deterministic, statistical, and machine learning. The article shows that each modeling method has its advantages, disadvantages, and data requirements, ranging from simple load modeling to more accurate models requiring large datasets.

Computer Science↗

Design, Detection, and Countermeasure of Frequency Spectrum Attack and Its Impact on Long Short-Term Memory Load Forecasting and Microgrid Energy Management

This paper introduces a frequency-domain false data injection attack called Frequency Spectrum Attack (FSA) and explores its effects on load forecasting and the energy management system (EMS) in a microgrid. The FSA analyzes time-series signals in the frequency domain to identify patterns in their frequency spectrum. It learns the distribution of dominant frequencies in a dataset of healthy signals. Subsequently, it manipulates the amplitudes of dominant frequencies within this healthy distribution, ensuring a stealthy attack against statistical analysis of the signal spectrum. We evaluated the performance of FSA on LSTM, a state-of-the-art network for load forecasting. The results show that FSA can triple the Mean Absolute Error (MAE) of predictions compared to the normal case and increase it by 70% compared to noise injection attacks. Furthermore, FSA indirectly enhances battery utilization in the EMS by 45%. We then proposed a detection method that combines statistical analysis and machine-learning-based classification techniques with features. The model effectively distinguishes FSA from healthy and noisy signals, achieving an accuracy of 98.7% and an F1-score of 98.1% on a load dataset, covering healthy, FSA, and noisy load data. Finally, a countermeasure was introduced based on the statistical analysis of the frequency spectrum of healthy signals to mitigate the impact of FSA. This countermeasure successfully reduces the MAE of the attacked model from 0.135 to 0.053, validating its effectiveness in mitigating FSA.

Nazeri, Amirhossein↗

Empirical Study of the Effect of Thermal Loading on the Heating Efficiency of Variable-Speed Air Source Heat Pumps

Heating buildings with air source heat pumps (ASHPs) has the potential to save energy compared to utilizing conventional heat sources. Accurate understanding of the efficiency of ASHPs is important to maximize the energy savings. While it is well understood that, in general, ASHP efficiency decreases with decreasing outdoor temperature, it is not well understood how the ASHP efficiency changes with different levels of thermal loading, even though it is an important consideration for sizing and controlling ASHPs. The goal of this study was to create an empirical model of the ASHP efficiency as a function of two independent variables–outside temperature and level of thermal loading. Four ductless mini-split ASHPs were evaluated in a cold chamber where the temperature (representing the outdoor temperature) was varied over a wide range. For each temperature, the ASHP performance data were collected at several levels of thermal loading. The data for all four ASHPs were combined and approximated with an analytical function that can be used as a general model for the ASHP steady-state efficiency as a function of the outside temperature and level of thermal loading. To the knowledge of the authors, no such empirical model that is solely based on third-party test data has been published before. While limitations exist, the model can be used to help guide future selection and operation of ASHPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Positron Beam Loading and Acceleration in the Blowout Regime of a Plasma Wakefield Accelerator

Plasma wakefield acceleration in the nonlinear blowout regime has achieved marked milestones in electron beam acceleration, demonstrating high acceleration gradients and energy efficiency while preserving excellent beam quality. However, this regime is deemed unsuitable for achieving positron acceleration of comparable results, which is vital for future compact electron–positron colliders. In this article, we find that an intense positron beam loaded at the back of beam-driven blowout cavity can self-consistently induce the focusing field and flatten the longitudinal wakefield, leading to stable, high-efficiency, and high-quality positron acceleration. This is achieved through the formation of an on-axis electron filament induced by positron beam load, which shapes the plasma wakefield in a distinct way compared to electron beam load in the blowout regime. Via a nonlinear analytic model and numerical simulations, we explain the novel beam loading effects of the interaction between the on-axis filament and the blowout cavity. High-fidelity simulations show that a high-charge positron beam can be accelerated with >20% energy transfer efficiency, ~1% energy spread, and ~1 mm·mrad normalized emittance, while considerably depleting the energy of the drive beam. The concept can also be extended to simultaneous acceleration of electron and positron beams and high transformer ratio positron acceleration as well. This development offers a new route for the application of plasma wakefield acceleration into particle physics.