Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Interactive handling of TV and range data for remotely controlled systems

The sensory subsystem of the JPL robotics project is described. The first sensory instrument is a pair of TV cameras, which provides a stereo view of the area of interest. The second is a laser range finder, which can be aimed in a requested direction and measure distance to a surface point that reflects the beam back. Both instruments are controlled by and are interfaced to computer. The calibration process and basic applications to obtain measurements of the external environment are described.

Yakimovsky, Y.↗

Flow unsteadiness effects on boundary layers

The development of boundary layers at high subsonic speeds in the presence of either mass flux fluctuations or acoustic disturbances (the two most important parameters in the unsteadiness environment affecting the aerodynamics of a flight vehicle) was investigated. A high quality database for generating detailed information concerning free-stream flow unsteadiness effects on boundary layer growth and transition in high subsonic and transonic speeds is described. The database will be generated with a two-pronged approach: (1) from a detailed review of existing literature on research and wind tunnel calibration database, and (2) from detailed tests in the Boundary Layer Apparatus for Subsonic and Transonic flow Affected by Noise Environment (BLASTANE). Special instrumentation, including hot wire anemometry, the buried wire gage technique, and laser velocimetry were used to obtain skin friction and turbulent shear stress data along the entire boundary layer for various free stream noise levels, turbulence content, and pressure gradients. This database will be useful for improving the correction methodology of applying wind tunnel test data to flight predictions and will be helpful for making improvements in turbulence modeling laws.

Murthy, Sreedhara V.↗

Ultra-High-Spectral-Resolution X-Ray/EUV Monochromator

Ultra-high-spectral-resolution X-Ray/EUV monochromator depends on Bragg reflection from multilayer coats and diffraction by mutlilayer-coated grating to select narrow wavelength band from input beam. Its monochromatic output beam of accurately known wavelength very useful in testing and calibration of x-ray telescopes, x-ray microscopes, photographic films, and photodetectors; in research in biological and biomedical disciplines, x-ray crystallography, properties and processing of materials, and x-ray lasers; and in x-ray lithography.

Hoover, Richard B.↗

Precision orbit determination of altimetric satellites

The ability to determine accurate global sea level variations is important to both detection and understanding of changes in climate patterns. Sea level variability occurs over a wide spectrum of temporal and spatial scales, and precise global measurements are only recently possible with the advent of spaceborne satellite radar altimetry missions. One of the inherent requirements for accurate determination of absolute sea surface topography is that the altimetric satellite orbits be computed with sub-decimeter accuracy within a well defined terrestrial reference frame. SLR tracking in support of precision orbit determination of altimetric satellites is significant. Recent examples are the use of SLR as the primary tracking systems for TOPEX/Poseidon and for ERS-1 precision orbit determination. The current radial orbit accuracy for TOPEX/Poseidon is estimated to be around 3-4 cm, with geographically correlated orbit errors around 2 cm. The significance of the SLR tracking system is its ability to allow altimetric satellites to obtain absolute sea level measurements and thereby provide a link to other altimetry measurement systems for long-term sea level studies. SLR tracking allows the production of precise orbits which are well centered in an accurate terrestrial reference frame. With proper calibration of the radar altimeter, these precise orbits, along with the altimeter measurements, provide long term absolute sea level measurements. The U.S. Navy's Geosat mission is equipped with only Doppler beacons and lacks laser retroreflectors. However, its orbits, and even the Geosat orbits computed using the available full 40-station Tranet tracking network, yield orbits with significant north-south shifts with respect to the IERS terrestrial reference frame. The resulting Geosat sea surface topography will be tilted accordingly, making interpretation of long-term sea level variability studies difficult.

Shum, C. K.↗

Performance of the Center-Of-Curvature Optical Assembly During Cryogenic Testing of the James Webb Space Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 meters in diameter and consists of 18 hexagonal segments, each 1.5 meters point-to-point. Each segment has a 6 degree-of-freedom hexapod actuation system and a radius-of-curvature (ROC) actuation system. The full telescope was tested at its cryogenic operating temperature at Johnson Space Center (JSC) in 2017. This testing included center-of-curvature measurements of the PM wavefront error using the Center-of-Curvature Optical Assembly (COCOA), along with the Absolute Distance Meter Assembly (ADMA). The COCOA included an interferometer, a reflective null, an interferometer-null calibration system, coarse and fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer was used to enable alignment and phasing of the PM segments. By combining measurements at two laser wavelengths, synthetic wavelengths up to 15 millimeters could be achieved, allowing mirror segments with millimeter-level piston errors to be phased to the nanometer level. The ADMA was used to measure and set the spacing between the PM and the focus of the COCOA null (i.e., the PM center-of-curvature) for determination of the ROC. This paper describes the COCOA, the PM test setup, the testing performed, the test results, and the performance of the COCOA in aligning & phasing the PM segments and measuring the final PM wavefront error.

JWST↗

Temperature dependent electronic quenching of OH(A 2 Sigma +, v-prime = 0) between 230 and 310 K

The present study is concerned with the electronic quenching of OH(A 2 Sigma +, v-prime = 0) at and below room temperature, taking into account the use of laser-induced fluorescence (LIF) in a low pressure flow cell for H2, CO2, O2, and N2 colliders. The reasons for the selection of the temperature range and the collision partners are related to the quantitative calibration of OH detection techniques in the troposphere, and to considerations of electronic quenching dynamics. Attention is given to production and rotational distribution, temperature measurements, and temperature dependent quenching rate constants.

Copeland, R. A.↗

An X-Band Radar Terrain Feature Detection Method for Low-Altitude SVS Operations and Calibration Using LiDAR

To enable safe use of Synthetic Vision Systems at low altitudes, real-time range-to-terrain measurements may be required to ensure the integrity of terrain models stored in the system. This paper reviews and extends previous work describing the application of x-band radar to terrain model integrity monitoring. A method of terrain feature extraction and a transformation of the features to a common reference domain are proposed. Expected error distributions for the extracted features are required to establish appropriate thresholds whereby a consistency-checking function can trigger an alert. A calibration-based approach is presented that can be used to obtain these distributions. To verify the approach, NASA's DC-8 airborne science platform was used to collect data from two mapping sensors. An Airborne Laser Terrain Mapping (ALTM) sensor was installed in the cargo bay of the DC-8. After processing, the ALTM produced a reference terrain model with a vertical accuracy of less than one meter. Also installed was a commercial-off-the-shelf x-band radar in the nose radome of the DC-8. Although primarily designed to measure precipitation, the radar also provides estimates of terrain reflectivity at low altitudes. Using the ALTM data as the reference, errors in features extracted from the radar are estimated. A method to estimate errors in features extracted from the terrain model is also presented.

Young, Steve↗

Argus: a new instrument for the measurement of the stratospheric dynamical tracers, N2O and CH4

We describe here a new instrument for the simultaneous, in situ measurement of the stratospheric tracer molecules, nitrous oxide (N2O) and methane (CH4). Argus is unique in its small size making it well suited for limited payload atmospheric research platforms. Argus employs second harmonic spectroscopy using tunable lead-salt diode lasers emitting in the mid-infrared. We first explain the Argus design philosophy followed by detailed descriptions of the instrument's optical, mechanical, and thermal sub-systems. Argus employs an in-flight calibration system providing real time calibrations and tightly constrained uncertainty estimates of the returned data. Data analysis is carried out using non-linear least-squares model fits to the acquired second harmonic spectra. A sampling of Argus data acquired on a recent stratospheric research campaign in the Arctic winter is presented.

Methane/analysis↗

(abstract) A Miniature, High-Sensitivity, Electron-Tunneling Accelerometer

A prototype low-noise accelerometer has been fabricated with an electron-tunneling transducer. By measuring the tunneling current between an electrode on the proof mass and a feedback-controlled monitor electrode, very small accelerations can be detected with high responsivity. This particular prototype (10x10x1.5 mm) was designed for underwater acoustic measurement from a few hertz to 1 kHz. The measured responsivity below the fundamental device resonance at 100 Hz is roughly 1500 volts per m/s(sup 2) with a measured noise spectral density of 10(sup -6) m/s(sup 2) per root hertz or less between 30 and 300 Hz. The noise floor is controlled primarily by 1/f noise in the tunneling current although the noise floor reaches the theoretical molecular-agitation limit at 100 hertz. The responsivity and directivity of the device were measured in a standard gradient-hydrophone calibrator; the noise floor was determined in a vacuum-ionization chamber assembled from commercial off-the-shelf components; and the detailed dynamics of the proof-mass motion were examined using a heterodyne laser interferometer that was scanned across the surface and synchronously detected with respect to the excitation.

accelerometer electron tunneling acoustic measurem↗

Non-Contact Stiffness Measurement of a Suspended Single Walled Carbon Nanotube Device

A new nanoscale electric field sensor was developed for studying triboelectric charging in terrestrial and Martian dust devils. This sensor is capable to measure the large electric fields for large dust devils without saturation. However, to quantify the electric charges and the field strength it is critical to calibrate the mechanical stiffness of the sensor devices. We performed a technical feasibility study of the Nano E-field Sensor stiffness by a non-contact stiffness measurement method. The measurement is based on laser Doppler vibrometer measurement of the thermal noise due to energy flunctuations in the devices. The experiment method provides a novel approach to acquire data that is essential in analyzing the quantitative performance of the E-field Nano Sensor. To carry out the non-contact stiffness measurement, we fabricated a new Single-Walled Carbon Nanotube (SWCNT) E-field sensor with different SWCNTs suspension conditions. The power spectra of the thermal induced displacement in the nano E-field sensor were measured at the accuracy of picometer. The power spectra were then used to derive the mechanical stiffness of the sensors. Effect of suspension conditions on stiffness and sensor sensitivty was discussed. After combined deformation and resistivity measurement, we can compare with our laboratory testing and field testing results. This new non-contact measurement technology can also help to explore to other nano and MEMS devices in the future.

Zheng, Yun↗

Quantitative Thermochemical Measurements in High-Pressure Gaseous Combustion

We present our strategic experiment and thermochemical analyses on combustion flow using a subframe burst gating (SBG) Raman spectroscopy. This unconventional laser diagnostic technique has promising ability to enhance accuracy of the quantitative scalar measurements in a point-wise single-shot fashion. In the presentation, we briefly describe an experimental methodology that generates transferable calibration standard for the routine implementation of the diagnostics in hydrocarbon flames. The diagnostic technology was applied to simultaneous measurements of temperature and chemical species in a swirl-stabilized turbulent flame with gaseous methane fuel at elevated pressure (17 atm). Statistical analyses of the space-/time-resolved thermochemical data provide insights into the nature of the mixing process and it impact on the subsequent combustion process in the model combustor.

Kojima, Jun J.↗

A comparison of dustsonde and LIDAR measurements of stratospheric aerosols

This paper describes the results and analysis of an experiment to compare the stratospheric aerosol profiles as measured by a balloon-borne in situ particle counter and by the backscattered light from a ground-based laser radar (LIDAR) operating at a wavelength of 6943 A. The profile comparison agrees within the experimental errors for particles with radii greater than 0.25 micrometer and for altitudes between 15 and 28 kilometers. Following the calibration tests, the LIDAR was used to monitor the stratospheric aerosols at Hampton, Virginia. Enhanced backscatter appeared sporadically in November and December of 1974 over Hampton; scattering ratios averaged over altitude increments of 450 meters range from 1.10 at 20 kilometers in early November to 3.3 at 17 kilometers on December 18. The source of this enhanced backscattering is attributed to the aerosols associated with the eruption of the Fuego volcano in Guatemala in mid-October.

Remsberg, E. E.↗

N2 pressure - broadened O3 line widths and strengths near 1129.4 cm-1

A Beer's Law experiment was performed with a tunable diode laser to find the N2 pressure broadening characteristics of a single 03 absorption line at 1129.426 cm for N2 pressures from 10 to 100 torr (O3 pressure = 3.16 torr). SO2 line positions were used for wavelength calibration. Line shapes were interatively fitted to a Lorentz function. Results were delta (HWHM in MHz) = 47.44 (+ or - 5.34) MHz + 1.730 (+ or - 0.088) MHz/torr *p(torr) with sigma = 0.9897. This intercept compares well with the Doppler O3 - O3 broadened (at 3.16 torr) width of 44.52 Hz. This result in a HWHM line width of 0.44 cm atm at 760 torr and 285 K. The line strengths integrated over delta nu = 0.55 cm were found to be N2 pressure dependent.

Copeland, G. E.↗

Laser measurements of ozone absorption cross sections in the Chappuis band

A sensitive spectrometer has been developed that exploits several He-Ne laser transitions in the visible for precise, high resolution measurements of Chappuis band ozone absorption cross sections at room temperature. An overall uncertainty of better than one percent has been achieved through a combination of transducer calibrations and an experimental technique that unambiguously determines the impurity content of each ozone sample. Results compare favorably with those from most previous analyses in the visible range, though some are obviously lower than this consensus due probably to errors in ozone density measurements.

Anderson, Stuart M.↗

Ignition and combustion characteristics of metallized propellants, phase 2

Experimental and analytical investigations focusing on aluminum/hydrocarbon gel droplet secondary atomization and its effects on gel-fueled rocket engine performance are being conducted. A single laser sheet sizing/velocimetry diagnostic technique, which should eliminate sizing bias in the data collection process, has been designed and constructed to overcome limitations of the two-color forward-scatter technique used in previous work. Calibration of this system is in progress and the data acquisition/validation code is being written. Narrow-band measurements of radiant emission, discussed in previous reports, will be used to determine if aluminum ignition has occurred in a gel droplet. A one-dimensional model of a gel-fueled rocket combustion chamber, described in earlier reports, has been exercised in conjunction with a two-dimensional, two-phase nozzle code to predict the performance of an aluminum/hydrocarbon fueled engine. Estimated secondary atomization effects on propellant burnout distance, condensed particle radiation losses to the chamber walls, and nozzle two phase flow losses are also investigated. Calculations indicate that only modest secondary atomization is required to significantly reduce propellant burnout distances, aluminum oxide residual size, and radiation heat losses. Radiation losses equal to approximately 2-13 percent of the energy released during combustion were estimated, depending on secondary atomization intensity. A two-dimensional, two-phase nozzle code was employed to estimate radiation and nozzle two phase flow effects on overall engine performance. Radiation losses yielded a one percent decrease in engine Isp. Results also indicate that secondary atomization may have less effect on two-phase losses than it does on propellant burnout distance and no effect if oxide particle coagulation and shear induced droplet breakup govern oxide particle size. Engine Isp was found to decrease from 337.4 to 293.7 seconds as gel aluminum mass loading was varied from 0-70 wt percent. Engine Isp efficiencies, accounting for radiation and two phase flow effects, on the order of 0.946 were calculated for a 60 wt percent gel, assuming a fragmentation ratio of five.

Mueller, D. C.↗

On the Accuracy of In Situ Water Vapor Measurements in the Troposphere and Lower Stratosphere with the Harvard Lyman-Alpha Hygrometer

In an effort to better constrain atmospheric water vapor mixing ratios and to understand the discrepancies between different measurements of water vapor in the stratosphere and troposphere, we have carefully examined data from the Harvard Lyman-alpha photofragment fluorescence hygrometer, which has flown on the NASA ER-2 aircraft from 1992 through 1998. The instrument is calibrated in the laboratory before and after each deployment, and the calibration is checked by direct absorption measurements in the troposphere. On certain flights, the ER-2 flew level tracks during which water vapor varied by up to 80 ppmv, under nearly constant atmospheric conditions. These flights provide a stringent test of our calibration via direct absorption and indicate agreement to within 3%. During the 1997 Photochemistry of Ozone Loss in the Arctic Region In Summer (POLARIS) mission, our Lyman-alpha instrument was compared with a new diode laser hygrometer from the Jet Propulsion Laboratory. Overall agreement was 5% during the June/July deployment and 1% for potential temperatures of 490 to 540 K. The accuracy of our instrument is shown to be +/-5 %, with an additional offset of at most 0.1 ppmv. Data from this instrument, combined with simultaneous measurements of CH4, and H2, are therefore ideal for studies of the hydrogen budget of the lower stratosphere.

Hintsa, Eric J.↗

Composites From in-Situ Consolidation Automated Fiber Placement of Thermoplastics for High-Rate Aircraft Manufacturing

The National Aeronautics and Space Administration (NASA) project Hi-Rate Composites Aircraft Manufacturing (HiCAM) aims to significantly increase commercial aircraft composite structures manufacturing rate. Thermoplastic composites offer attractive solutions to rapid manufacturing due to their ability to be formed and consolidated quickly. NASA has a particular interest in assessing composite structure manufacturing utilizing an in-situ consolidation automated fiber placement (AFP) of thermoplastics (ICAT) process employing current state-of-the-art laser heating systems. Three semi-crystalline polyaryletherketone (PAEK) thermoplastic tape materials were characterized to ascertain the ICAT process parameters. The required laser power settings were determined at Electroimpact, Inc., measuring material temperatures utilizing a forward looking infrared (FLIR) thermal imaging camera and thermocouples. The material temperature, tool temperature, and placement speed were varied for resulting consolidation quality assessment. The resulting temperature data were also utilized to calibrate thermal analysis models under development at NASA. The experimental temperature data confirmed analytical results. The quality of the resulting test panels was evaluated by both non-destructive evaluation as well as destructively by photo-microscopy. The effect on interlaminar strength was determined by short beam strength testing. Test results of carbon fiber laminates fabricated by ICAT using polyetheretherketone (PEEK), polyetherketoneketone (PEKK), and low-melt polyaryletherketone (LM-PAEK) at various placement temperatures and placement speeds are presented.

thermoplastic composites↗

Calibration and Sequence Development Status for the Sample Analysis at Mars Investigation on the Mars Science Laboratory

The measurement goals of the Sample Analysis at Mars (SAM) instrument suite on the "Curiosity" Rover of the Mars Science Laboratory (MSL) include chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples [1,2]. SAM directly supports the ambitious goals of the MSL mission to provide a quantitative assessment of habitability and preservation in Gale crater by means of a range of chemical and geological measurements [3]. The SAM FM combined calibration and environmental testing took place primarily in 2010 with a limited set of tests implemented after integration into the rover in January 2011. The scope of SAM FM testing was limited both to preserve SAM consumables such as life time of its electromechanical elements and to minimize the level of terrestrial contamination in the SAM instrument. A more comprehensive calibration of a SAM-like suite of instruments will be implemented in 2012 with calibration runs planned for the SAM testbed. The SAM Testbed is nearly identical to the SAM FM and operates in a ambient pressure chamber. The SAM Instrument Suite: SAM's instruments are a Quadrupole Mass Spectrometer (QMS), a 6-column Gas Chromatograph (GC), and a 2-channel Tunable Laser Spectrometer (TLS). Gas Chromatography Mass Spectrometry is designed for identification of even trace organic compounds. The TLS [5] secures the C, H, and O isotopic composition in carbon dioxide, water, and methane. Sieved materials are delivered from the MSL sample acquisition and processing system to one of68 cups of the Sample Manipulation System (SMS). 59 of these cups are fabricated from inert quartz. After sample delivery, a cup is inserted into one of 2 ovens for evolved gas analysis (EGA ambient to >9500C) by the QMS and TLS. A portion of the gas released can be trapped and subsequently analyzed by GCMS. Nine sealed cups contain liquid solvents and chemical derivatization or thermochemolysis agents to extract and transform polar molecules such as amino acids, nucleobases, and carboxylic acids into compounds that are sufficiently volatile to transmit through the GC columns. The remaining 6 cups contain calibrants. SAM FM Calibration Overview: The SAM FM calibration in the Mars chamber employed a variety of pure gases, gas mixtures, and solid materials. Isotope calibration runs for the TLS utilized 13C enriched C02 standards and 0 enriched CH4. A variety of fluorocarbon compounds that spanned the entire mass range of the QMS as well as C3-C6 hydrocarbons were utilized for calibration of the GCMS. Solid samples consisting of a mixture of calcite, melanterite, and inert silica glass either doped or not with fluorocarbons were introduced into the SAM FM cups through the SAM inlet funnel/tube system.

Mahaffy, Paul R.↗