Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The long term stability of VLBI earth orientation measurements

Tectonic motions will, in general, change the orientation as well as the length of baselines used in Very Long Baseline Interferometry (VLBI), and will thus cause slow divergences between earth orientation results obtained with different VLBI networks, as well as between VLBI results and those obtained by satellite laser ranging and lunar laser ranging. Such drifts (on the order of a milliarcsecond/year) are inherently interesting as well as being significant in combinations of orientation results from different sources. The geodetic study of tectonic motions is also closely connected to research into the nature and causes of systematic errors in data from the modern techniques of space geodesy. Both a special coordinate system found to be of use in the analysis of VLBI data and tectonic motion estimates for a VLBI baseline stretching from California to Australia are described.

Eubanks, T. M.↗

GPS inferred geocentric reference frame for satellite positioning and navigation

Accurate geocentric three-dimensional positioning is of great importance for various geodetic and oceanographic applications. While relative positioning accuracy of a few centimeters has become a reality using Very Long Baseline Interferometry (VLBI), the uncertainty in the offset of the adopted coordinate system origin from the geocenter is still believed to be of the order of one meter. Satellite Laser Ranging (SLR) is capable of determining this offset to better than 10 cm, though, because of the limited number of satellites, this requires a long arc of data. The Global Positioning System (GPS) measurements provide a powerful alternative for an accurate determination of this origin offset in relatively short period of time. Two strategies are discussed, the first utilizes the precise relative positions predetermined by VLBI, whereas the second establishes a reference frame by holding only one of the tracking sites longitude fixed. Covariance analysis studies indicate that geocentric positioning to an accuracy of a few centimeters can be achieved with just one day of precise GPS pseudorange and carrier phase data.

Malla, Rajendra P.↗

Optical metrology for Starlight Separated Spacecraft Stellar Interferometry Mission

We describe a high-precision inter-spacecraft metrology system designed for NASA 's StarLight mission, a space-based separated-spacecraft stellar interferometer. It consists of dual-target linear metrology, based on a heterodyne interferometer with carrier phase modulation, and angular metrology designed to sense the pointing of the laser beam and provides bearing information. The dual-target operation enables one metrology beam to sense displacement of two targets independently. We present the current design, breadboard implementation of the Metrology Subsystem in a stellar interferometer testbed and the present state of development of flight qualifiable subsystem components.

metrology stellar interferometry formation flying↗

Optical nanofiber testbeds for benchmarking membrane-waveguide photonic integrated circuit platforms toward on-chip quantum inertial sensing

Recent advances in cold atom interferometry with optical and magnetic atom guides have set the stage for quantum inertial sensors capable of operating in dynamic environments. In this work, we present three key innovations—evanescent-field (EF) atom guides, optical nanofiber testbeds, and membrane-waveguide photonic integrated circuit (PIC) platforms—to advance EF-guided atom interferometry. First, we demonstrate EF atom guides on optical nanofiber testbeds, which serve as performance benchmarks for our membrane-waveguide PIC platforms. Second, we achieve low-power (⁠ ~ 5 mW) guiding of freely moving, laser-cooled 133 Cs atoms in two-color, traveling-wave EF optical dipole traps at the novel, heat-efficient magic wavelengths of 793 and 937 nm (i.e., “793/937-nm EF atom guides”). Concurrently, we design and fabricate membrane-waveguide PIC platforms for these EF atom guides; in our prior work, we showed that these structures safely accommodate 4–6 times the required optical trap power under vacuum and enable dense cold atom generation via magneto-optical trapping in the vicinity of the optical wavguide for efficient loading. Third, we verify preserved atomic coherence via microwave fields and EF-coupled Doppler-free Raman beams; to our knowledge, this is the first report of coherence fringes driven by co-propagating EF-coupled Raman beams with only 150 nW of total optical power. By providing a direct comparison between optical nanofiber testbeds and membrane-waveguide PIC platforms, our results lay critical groundwork for the on-chip realization of EF-guided atom interferometry and the development of fully integrated, compact, lightweight, and low-power quantum accelerometers and gyroscopes.

Orozco, Adrian [Sandia National Laboratories (SNL-↗

Manipulation of Micro Scale Particles in an Optical Trap Using Interferometry

This research shows that micro particles can be manipulated via interferometric patterns superimposed on an optical tweezers beam. Interferometry allows the manipulation of intensity distributions, and thus, force distributions on a trapped particle. To demonstrate the feasibility of such manipulation, 458 nm light, from an argon-ion laser, was injected into a Mach Zender interferometer. One mirror in the interferometer was oscillated with a piezoelectric phase modulator. The light from the interferometer was then injected into a microscope to trap a 9.75 micron polystyrene sphere. By varying the phase modulation, the sphere was made to oscillate in a controlled fashion.

Seibel, Robin↗

NASA Tech Briefs, September 2004

Topics covered include: Brazing SiC/SiC Composites to Metals; Composite-Material Tanks with Chemically Resistant Liners; Thermally Conductive Metal-Tube/Carbon-Composite Joints; Improved BN Coatings on SiC Fibers in SiC Matrices; Iterative Demodulation and Decoding of Non-Square QAM; Measuring Radiation Patterns of Reconfigurable Patch Antennas on Wafers; Low-Cutoff, High-Pass Digital Filtering of Neural Signals; Further Improvement in 3DGRAPE; Ground Support Software for Spaceborne Instrumentation; MER SPICE Interface; Simulating Operation of a Planetary Rover; Analyzing Contents of a Computer Cache; Discrepancy Reporting Management System; Silicone-Rubber Microvalves Actuated by Paraffin; Hydraulic Apparatus for Mechanical Testing of Nuts; Heat Control via Torque Control in Friction Stir Welding; Manufacturing High-Quality Carbon Nanotubes at Lower Cost; Setup for Visual Observation of Carbon-Nanotube Arc Process; Solution Preserves Nucleic Acids in Body-Fluid Specimens; Oligodeoxynucleotide Probes for Detecting Intact Cells; Microwave-Spectral Signatures Would Reveal Concealed Objects; Digital Averaging Phasemeter for Heterodyne Interferometry; Optoelectronic Instrument Monitors pH in a Culture Medium; Imaging of gamma-Irradiated Regions of a Crystal; Photodiode-Based, Passive Ultraviolet Dosimeters; Discrete Wavelength-Locked External Cavity Laser; Flexible Shields for Protecting Spacecraft Against Debris; Part 2 of a Computational Study of a Drop-Laden Mixing Layer; Controllable Curved Mirrors Made from Single-Layer EAP Films; and Demonstration of a Pyrotechnic Bolt-Retractor System.

Source record↗

Probing Attosecond Bound Electron Dynamics Driven by Strong-Field Light Transients

The project aimed to drive strong-field excitation of bound electronic coherences in gas-phase atoms and molecules using a novel source of near-single-cycle optical field transients, based on industrial-grade Yb:solid-state laser technology. Key objectives included generating near-single cycle field transients and isolated attosecond pulses, reconstructing time-dependent wave packets in atoms and molecules, probing their decoherence using attosecond interferometry, and controlling the dynamic evolution of systems on attosecond to few-femtosecond timescales. A secondary goal of the project was to develop field-resolved measurement platforms as a novel approach for studying electron dynamics in atomic and molecular systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

A demonstration of centimeter-level monitoring of polar motion with the Global Positioning System

Daily estimates of the Earth's pole position were obtained with the Global Positioning System (GPS) by using measurements obtained during the GPS IERS (International Earth Rotation Service) and Geodynamics (GIG'91) experiment from 22 Jan. to 13 Feb. 1991. Data from a globally distributed network consisting of 21 Rogue GPS receivers were chosen for the analysis. A comparison of the GPS polar motion series with nine 24-hour very long baseline interferometry (VLBI) estimates yielded agreement in the day-to-day pole position of about 1.5 cm for both X and Y polar motion. A similar comparison of GPS and satellite laser ranging (SLR) data showed agreement to about 1.0 cm. These preliminary results indicate that polar motion can be determined by GPS independent of, and at a level comparable to, that which is obtained from either VLBI or SLR. Furthermore, GPS can provide these data with a daily frequency that neither alternative technique can readily achieve. Thus, GPS promises to be a powerful tool for determining high-frequency platform parameter variation, essential for the ultraprecise spacecraft-tracking requirements of the coming years.

Lindqwister, U. J.↗

Effect of Injector Geometry on Atomization of a Liquid-Liquid Double Swirl Coaxial Injector Using Non-invasive Laser, Optical and X-ray Techniques

The spray characteristics of a liquid-liquid double swirl coaxial injector were studied using non-invasive optical, laser, and X-ray diagnostics. A parametric study of injector exit geometry demonstrated that spray breakup time, breakup type and sheet stability could be controlled with exit geometry. Phase Doppler interferometry was used to characterize droplet statistics and non-dimensional droplet parameters over a range of inlet conditions and for various fluids allowing for a study on the role of specific fluid properties in atomization. Further, X-ray radiography allowed for investigation of sheet thickness and breakup length to be quantified for different recess exit diameters and inlet pressures. Finally, computed tomography scans revealed that the spray cone was distinctively non-uniform and comprised of several pockets of increased mass flux.

Radke, C. R.↗

Optical interferometry in fluid dynamics research

Optical interferometry techniques were applied to the investigation of transonic airfoil flow fields in large wind tunnels. Holographic interferometry techniques were used to study 2 dimensional symmetric NACA 64A010 and Douglas Aircraft Co. DSMA671 supercritical airfoil performance in the NASA Ames 2 x 2 ft transonic wind tunnel. Quantitative data obtained from the interferograms were compared to the surface pressure data. The agreement obtained verified the accuracy of the flow visualization and demonstrated the potential for acquiring quantitative scalar results. Measurements of the inviscid flow speed and the boundary layer and wake velocity profiles were extracted from the interferograms and compared to laser Doppler velocimeter measurements. These results were also in good agreement. A method for acquiring real time interferometric data in large scale facilities was developed. This method, based on the point diffraction interferometer, was successfully tested in the 2 x 2 ft transonic wind tunnel. The holographic and real time interferometry methods were applied to the investigations of circulation control airfoils utilizing the Coanda effect. These results reveals the details of the jet interacting with the trailing edge boundary layer and the other parameters affecting the lift augmentation.

Bachalo, W. D.↗

Instantaneous Doppler Global Velocimetry Measurements of a Rotor Wake: Lessons Learned

A combined Doppler Global Velocimetry (DGV) and Projection Moir Interferometry (PMI) investigation of a helicopter rotor wake flow field and rotor blade deformation is presented. The three-component DGV system uses a single-frequency, frequency-doubled Nd:YAG laser to obtain instantaneous velocity measurements in the flow. The PMI system uses a pulsed laser-diode bar to obtain blade bending and twist measurements at the same instant that DGV measured the flow. The application of pulse lasers to DGV and PMI in large-scale wind tunnel applications represents a major step forward in the development of these technologies. As such, a great deal was learned about the difficulties of using these instruments to obtain instantaneous measurements in large facilities. Laser speckle and other image noise in the DGV data images were found to be traceable to the Nd:YAG laser. Although image processing techniques were used to virtually eliminate laser speckle noise, the source of low-frequency image noise is still under investigation. The PMI results agreed well with theoretical predictions of blade bending and twist.

Meyers, James↗

Polarization Considerations for the Laser Interferometer Space Antenna (LISA)

A polarization ray trace model of the Laser Interferometer Space Antenna's (LISA) optical path is being created. The model will be able to assess the effects of various polarizing elements and the optical coatings on the required picometer level interferometry. All of the computational steps are described in detail. This should eliminate any ambiguities associated with polarization ray trace modeling of interferometers and provide a basis for determining its limitations and serve as a clearly defined starting point for future improvements.

Waluschka, Eugene↗

LISA Pathfinder Instrument Data Analysis

LISA Pathfinder (LPF) is an ESA-launched demonstration mission of key technologies required for the joint NASA-ESA gravitational wave observatory in space, LISA. As part of the LPF interferometry investigations, analytic models of noise sources and corresponding noise subtraction techniques have been developed to correct for effects like the coupling of test mass jitter into displacement readout, and fluctuations of the laser frequency or optical pathlength difference. Ground testing of pre-flight hardware of the Optical Metrology subsystem is currently ongoing at the Albert Einstein Institute Hannover. In collaboration with NASA Goddard Space Flight Center, the LPF mission data analysis tool LTPDA is being used to analyze the data product of these tests. Furthermore, the noise subtraction techniques and in-flight experiment runs for noise characterization are being defined as part of the mission experiment master plan. We will present the data analysis outcome of preflight hardware ground tests and possible noise subtraction strategies for in-flight instrument operations.

Guzman, Felipe↗

Optical Diagnostics of Solution Crystal Growth

Non-contact optical techniques such as, optical heterodyne, ellipsometry and interferometry, for real time in-situ monitoring of solution crystal growth are demonstrated. Optical heterodyne technique has the capability of measuring the growth rate as small as 1A/sec. In a typical Michelson interferometer set up, the crystal is illuminated by a Zeeman laser with frequency omega(sub 1) and the reference beam with frequency omega(sub 2). As the crystal grows, the phase of the rf signal changes with respect to the reference beam and this phase change is related to the crystal growth rate. This technique is demonstrated with two examples: (1) by measuring the copper tip expansion/shrinkage rate and (2) by measuring the crystal growth rate of L-Arginine Phosphate (LAP). The first test shows that the expansion/shrinkage rate of copper tip was fast in the beginning, and gets slower as the expansion begins to stabilize with time. In crystal growth, the phase change due the crystal growth is measured using a phase meter and a strip chart recorder. Our experimental results indicate a varied growth rate from 69.4 to 92.6A per sec. The ellipsometer is used to study the crystal growth interface. From these measurements and a theoretical modeling of the interface, the various optical parameters can be deduced. Interferometry can also be used to measure the growth rate and concentration gradient in the vicinity of the crystal.

Kim, Yongkee↗

Optical interferometry in fluid dynamics research

Optical interferometry techniques have been applied to the investigation of transonic airfoil flow fields in large-scale wind tunnels. Holographic interferometry techniques were used in the study of two-dimensional symmetric NACA 64A010 and Douglas Aircraft Company DSMA671 supercritical airfoil performance in the NASA Ames 2 ft x 2 ft transonic wind tunnel. Quantitative data obtained from the interferograms were compared to the surface pressure data. The excellent agreement obtained verified the accuracy of the flow visualization and demonstrated the potential for acquiring quantitative scalar results. Measurements of the inviscid flow speed and the boundary layer and wake velocity profiles were extracted from the interferograms and compared to laser Doppler velocimeter measurements. These results were also in good agreement. A method for acquiring real-time interferometric data in large-scale facilities was developed. This method, based on the point diffraction interferometer, was successfully tested in the Ames 2 ft x 2 ft transonic wind tunnel. The holographic and real-time interferometry methods were applied to the investigations of circulation control airfoils utilizing the Coanda effect. These results revealed the details of the jet interaction with the trailing edge boundary layer and the other parameters affecting the lift augmentation.

Bachalo, W. D.↗

VLBI Validation Project

Two training and three operational Deep Space Network experiments conducted in support of the very long baseline interferometry (VLBI) validation project are reported. Vector measurements using common benchmark locations at continental distances (Goldstone, Haystack, and the McDonald Observatory) with an accuracy goal on the order of 5 cm. were obtained and compared with laser ranging systems data.

Ross, W. J.↗