Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Final Technical Report Under SC0018278

Work supported by the grant "Stability and Control of Burning Tokamak Plasmas with Resistive Walls" in the period Aug 2017 to Aug 2018 can be cast in three general categories: (1) linear tearing regimes and the effects on the response to error fields and resistive walls: (2) nonlinear tearing modes in the presence of error fields, with locking; and (3) energetic particle effects. In the first category, we have completed a study of tearing mode regimes with extended MHD effects, including parallel dynamics and toroidal effects, notably favorable average curvature. This work has been presented at the 2018 Sherwood Conference in Ref.[1]. This work has been published in the ArXiv in Ref.[2] and is being prepared for publication in Physics of Plasmas. A systematic study of shaping in a tokamak plasma with resistive tearing layers and a resistive wall has been presented in the Ph D dissertation[3] by Dov Rhodes, a student of Andrew Cole at Columbia University. John Finn was on Rhodes's Ph D committee, and was a co-author of a paper published in Physics of Plasmas on that work. A detailed study of nonlinear tearing modes in the presence of finite beta, favorable average curvature, and an error field has been nearly completed. In this study it was found that the response to an error field with real frequency a tearing layer agreed with analytic results, and that tearing mode saturation by flattening of the current profile as well as destabilization due to flattening of the pressure profile were important factors in the locking process. This work was presented at the 2017 APS/DPP Conference and at the 2018 Sherwood Conference. The effects of energetic ions on tearing modes was presented at the 2017 APS/DPP Conference and in the Ph D dissertation of Michael Halfmoon. John Finn served as a committee member on Halfmoon's Ph D committee. Extensions to this work including two-fluid effects were performed and presented at the APS/DPP Conference in 2017.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability and Control of Burning Tokamak Plasmas with Resistive Walls (Final Report)

Work supported by the grant, "Stability and Control of Burning Tokamak Plasmas with Resistive Walls" in the period Aug 2017 to 2023 can be cast in three general categories: (1) linear tearing regimes and the effects on the response to error fields and resistive walls: (2) nonlinear tearing modes in the presence of error fields, with locking; and (3) energetic particle effects. In the first category, we have completed a study of tearing mode regimes with extended MHD effects, including parallel dynamics and toroidal effects, notably favorable average curvature. This work has been presented at the 2018 Sherwood Conference. This work has been published in the ArXiv and is being prepared for publication in Physics of Plasmas. A systematic study of shaping in a tokamak plasma with resistive tearing layers and a resistive wall has been presented in the PhD dissertation by Dov Rhodes, a student of Andrew Cole at Columbia University. John Finn was on Rhodes's PhD committee, and was a co-author of a paper published in Physics of Plasmas on that work. A detailed study of nonlinear tearing modes in the presence of finite beta, favorable average curvature, and an error field has been nearly completed. In this study it was found that the response to an error field with real frequency a tearing layer agreed with analytic results, and that tearing mode saturation by flattening of the current profile as well as destabilization due to flattening of the pressure profile were important factors in the locking process. This work was presented at the 2017 APS/DPP Conference and at the 2018 Sherwood Conference. The effects of energetic ions on tearing modes was presented at the 2017 APS/DPP Conference and in the PhD dissertation of Michael Halfmoon. John Finn served as a committee member on Halfmoon's PhD committee. Extensions to this work including two fluid effects were performed and presented at the APS/DPP Conference in 2017.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

spammpack, Version 2013-06-18

This library is an implementation of the Sparse Approximate Matrix Multiplication (SpAMM) algorithm introduced. It provides a matrix data type, and an approximate matrix product, which exhibits linear scaling computational complexity for matrices with decay. The product error and the performance of the multiply can be tuned by choosing an appropriate tolerance. The library can be compiled for serial execution or parallel execution on shared memory systems with an OpenMP capable compiler

Source record↗

SU-F-T-383: Robustness for Patient Setup Error in Total Body Irradiation Using Volumetric Modulated Arc Therapy (VMAT)

Purpose: Total body irradiation (TBI) and total marrow irradiation (TMI) using Tomotherapy have been reported. A gantry-based linear accelerator uses one isocenter during one rotational irradiation. Thus, 3–5 isocenter points should be used for a whole plan of TBI-VMAT during smoothing out the junctional dose distribution. IGRT provides accurate and precise patient setup for the multiple junctions, however it is evident that some setup errors should occur and affect accuracy of dose distribution in the area. In this study, we evaluated the robustness for patient’s setup error in VMAT-TBI. Methods: VMAT-TBI Planning was performed in an adult whole-body human phantom using Eclipse. Eight full arcs with four isocenter points using 6MV-X were used to cover the entire whole body. Dose distribution was optimized using two structures of patient’s body as PTV and lung. The two arcs were shared with one isocenter and the two arcs were 5 cm-overlapped with the other two arcs. Point absolute dose using ionization-chamber and planer relative dose distribution using film in the junctional regions were performed using water-equivalent slab phantom. In the measurements, several setup errors of (+5∼−5mm) were added. Results: The result of the chamber measurement shows the deviations were within ±3% when the setup errors were within ±3 mm. In the planer evaluation, the pass ratio of gamma evaluation (3%/2mm) shows more than 90% if the errors within ±3 mm. However, there were hot/cold areas in the edge of the junction even with acceptable gamma pass ratio. 5 mm setup error caused larger hot and cold areas and the dosimetric acceptable areas were decreased in the overlapped areas. Conclusion: It can be clinically acceptable for VMAT-TBI when patient setup error is within ±3mm. Averaging effects from patient random error would be helpful to blur the hot/cold area in the junction.

60 APPLIED LIFE SCIENCES↗

A performance model for GPUs with caches

To exploit the abundant computational power of the world's fastest supercomputers, an even workload distribution to the typically heterogeneous compute devices is necessary. While relatively accurate performance models exist for conventional CPUs, accurate performance estimation models for modern GPUs do not exist. This paper presents two accurate models for modern GPUs: a sampling-based linear model, and a model based on machine-learning (ML) techniques which improves the accuracy of the linear model and is applicable to modern GPUs with and without caches. We first construct the sampling-based linear model to predict the runtime of an arbitrary OpenCL kernel. Based on an analysis of NVIDIA GPUs' scheduling policies we determine the earliest sampling points that allow an accurate estimation. The linear model cannot capture well the significant effects that memory coalescing or caching as implemented in modern GPUs have on performance. We therefore propose a model based on ML techniques that takes several compiler-generated statistics about the kernel as well as the GPU's hardware performance counters as additional inputs to obtain a more accurate runtime performance estimation for modern GPUs. We demonstrate the effectiveness and broad applicability of the model by applying it to three different NVIDIA GPU architectures and one AMD GPU architecture. On an extensive set of OpenCL benchmarks, on average, the proposed model estimates the runtime performance with less than 7 percent error for a second-generation GTX 280 with no on-chip caches and less than 5 percent for the Fermi-based GTX 580 with hardware caches. On the Kepler-based GTX 680, the linear model has an error of less than 10 percent. On an AMD GPU architecture, Radeon HD 6970, the model estimates with 8 percent of error rates. As a result, the proposed technique outperforms existing models by a factor of 5 to 6 in terms of accuracy.

97 MATHEMATICS AND COMPUTING↗

Automated Dynamic Demand Response Implementation on a Micro-grid

In this paper, we describe a system for real-time automated Dynamic and Sustainable Demand Response with sparse data consumption prediction implemented on the University of Southern California campus microgrid. Supply side approaches to resolving energy supply-load imbalance do not work at high levels of renewable energy penetration. Dynamic Demand Response (D 2 R) is a widely used demand-side technique to dynamically adjust electricity consumption during peak load periods. Our D 2 R system consists of accurate machine learning based energy consumption forecasting models that work with sparse data coupled with fast and sustainable load curtailment optimization algorithms that provide the ability to dynamically adapt to changing supply-load imbalances in near real-time. Our Sustainable DR (SDR) algorithms attempt to distribute customer curtailment evenly across sub-intervals during a DR event and avoid expensive demand peaks during a few sub-intervals. It also ensures that each customer is penalized fairly in order to achieve the targeted curtailment. We develop near linear-time constant-factor approximation algorithms along with Polynomial Time Approximation Schemes (PTAS) for SDR curtailment that minimizes the curtailment error defined as the difference between the target and achieved curtailment values. Our SDR curtailment problem is formulated as an Integer Linear Program that optimally matches customers to curtailment strategies during a DR event while also explicitly accounting for customer strategy switching overhead as a constraint. We demonstrate the results of our D 2 R system using real data from experiments performed on the USC smartgrid and show that 1) our prediction algorithms can very accurately predict energy consumption even with noisy or missing data and 2) our curtailment algorithms deliver DR with extremely low curtailment errors in the 0.01-0.05 kWh range.

Kuppannagari, Sanmukh R.↗

Multipole approximation of special nonlinear magnets for the IOTA ring

All existing focusing optics for accelerators are built to be "linear", i.e. the transverse focusing force is proportional to the particle displacement from the closed orbit. Such approach is used in order to make trajectories stable in the entire area of phase space, because the potential describing linear focusing is integrable and does not produce chaotic motion. Technically, the needed field is achieved with the help of dipole and quadrupole magnets. But the linear motion is unstable to perturbations in the focusing fields and excludes any betatron tune spread over particle's energy, which is beneficial for the beam stability. Moreover, the focusing strength depends on the particle's energy deviation from the designed one. These undesired effects are usually suppressed by the addition of non- linear elements, such as sextupoles and octupoles. Unfortunately, these additions make focusing potential nonintegrabe, leading to the limitation of stable phase space area. Recent research showed, that there exist non-linear potentials that, nevertheless, are fully integrable [1, 2]. Thus, there is an opportunity to create stable non-linear focusing optics that provides high betatron tune spread and mitigate magnetic field errors. This approach is to be implemented in electron storage ring called Integrable Optics Test Accelerator (IOTA) at Fermilab [3]. The main goal is to show the possibility to implement the nonlinear integrable system in a realistic accelerator design. Development of a magnet, which creates exact non-linear potential, is a technically complicated task, that takes much time and efforts. However, it is possible to expand the non- linear potential into superposition of multipoles of even orders (i.e quadrupole, octupole, etc.). Though this series is not convergent in the entire space, a few low order terms can be used to model the true potential in some limited area. In turn, each of the multipole potentials can be generated by speci ed electrical current in PCB coiled on the surface of storage ring's vacuum tube. Such approach is much cheaper than the creation of a magnet of solid iron with high current coil and faster than the development of \exact" non-linear magnet, but it can help identify some features of non-linear integrable optics application. The goal of this research work is to find analytically the angular distribution of electrical current on the surface of the vacuum tube, which creates inside it multipole potential with given parameters. Hereafter, there is the task to develop a model of flexible printed circuit board (PCB), which could be coiled around the vacuum tube in order to provide the desired current distribution.

Vorobev, Viktor↗

SU-D-18C-04: The Feasibility of Quantifying MRI Contrast Agent in Pulsatile Flowing Blood Using DCE-MRI

Purpose: To assess the feasibility of accurately quantifying the concentration of MRI contrast agent (CA) in pulsatile flowing blood by measuring its T{sub 1}, as is common for the purposes of obtaining a patientspecific arterial input function (AIF). Dynamic contrast enhanced (DCE) - MRI and pharmacokinetic (PK) modelling is widely used to produce measures of vascular function but accurate measurement of the AIF undermines their accuracy. A proposed solution is to measure the T{sub 1} of blood in a large vessel using the Fram double flip angle method during the passage of a bolus of CA. This work expands on previous work by assessing pulsatile flow and the changes in T{sub 1} seen with a CA bolus. Methods: A phantom was developed which used a physiological pump to pass fluid of a known T{sub 1} (812ms) through the centre of a head coil of a clinical 1.5T MRI scanner. Measurements were made using high temporal resolution sequences suitable for DCE-MRI and were used to validate a virtual phantom that simulated the expected errors due to pulsatile flow and bolus of CA concentration changes typically found in patients. Results: : Measured and virtual results showed similar trends, although there were differences that may be attributed to the virtual phantom not accurately simulating the spin history of the fluid before entering the imaging volume. The relationship between T{sub 1} measurement and flow speed was non-linear. T{sub 1} measurement is compromised by new spins flowing into the imaging volume, not being subject to enough excitations to have reached steady-state. The virtual phantom demonstrated a range of recorded T{sub 1} for various simulated T{sub 1} / flow rates. Conclusion: T{sub 1} measurement of flowing blood using standard DCE-MRI sequences is very challenging. Measurement error is non-linear with relation to instantaneous flow speed. Optimising sequence parameters and lowering baseline T{sub 1} of blood should be considered.

60 APPLIED LIFE SCIENCES↗

cabbi-bio/ESM-R-script

This script is intended to provide a starting point for users to implement the equivalent soil mass (ESM) approach for calculating soil organic carbon (SOC) stocks and SOC mass percentages (commonly called “SOC concentration”). The user should read this readme file and understand how the script works before using it. The script contains some basic error checking algorithms, but it cannot catch all data entry mistakes. It is possible to misuse the script and produce invalid results. The script was designed to work on individual soil cores that have been divided into three or more contiguous segments, as the cubic spline function contains four coefficients. The script has not been tested on soil cores containing fewer than three contiguous segments. If only one segment is present, interpolation will necessarily be linear rather than cubic, which is expected to result in higher predictive error (Wendt & Hauser, 2013). Considering the wide range of potential applications, the script should not be expected to function correctly in all situations. The user is encouraged to modify or rewrite the script to meet their specific needs.

von Haden, Adam↗

OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. III. MEASURES BELOW THE DIFFRACTION LIMIT OF THE WIYN TELESCOPE

In this paper, we study the ability of CCD- and electron-multiplying-CCD-based speckle imaging to obtain reliable astrometry and photometry of binary stars below the diffraction limit of the WIYN 3.5 m Telescope. We present a total of 120 measures of binary stars, 75 of which are below the diffraction limit. The measures are divided into two groups that have different measurement accuracy and precision. The first group is composed of standard speckle observations, that is, a sequence of speckle images taken in a single filter, while the second group consists of paired observations where the two observations are taken on the same observing run and in different filters. The more recent paired observations were taken simultaneously with the Differential Speckle Survey Instrument, which is a two-channel speckle imaging system. In comparing our results to the ephemeris positions of binaries with known orbits, we find that paired observations provide the opportunity to identify cases of systematic error in separation below the diffraction limit and after removing these from consideration, we obtain a linear measurement uncertainty of 3-4 mas. However, if observations are unpaired or if two observations taken in the same filter are paired, it becomes harder to identify cases of systematic error, presumably because the largest source of this error is residual atmospheric dispersion, which is color dependent. When observations are unpaired, we find that it is unwise to report separations below approximately 20 mas, as these are most susceptible to this effect. Using the final results obtained, we are able to update two older orbits in the literature and present preliminary orbits for three systems that were discovered by Hipparcos.

79 ASTRONOMY AND ASTROPHYSICS↗

Model reduction of dynamical systems on nonlinear manifolds using deep convolutional autoencoders

Nearly all model-reduction techniques project the governing equations onto a linear subspace of the original state space. Such subspaces are typically computed using methods such as balanced truncation, rational interpolation, the reduced-basis method, and (balanced) proper orthogonal decomposition (POD). Unfortunately, restricting the state to evolve in a linear subspace imposes a fundamental limitation to the accuracy of the resulting reduced-order model (ROM). In particular, linear-subspace ROMs can be expected to produce low-dimensional models with high accuracy only if the problem admits a fast decaying Kolmogorov n -width (e.g., diffusion-dominated problems). Unfortunately, many problems of interest exhibit a slowly decaying Kolmogorov n-width (e.g., advection-dominated problems). To address this, we propose a novel framework for projecting dynamical systems onto nonlinear manifolds using minimum-residual formulations at the time-continuous and time-discrete levels; the former leads to manifold Galerkin projection, while the latter leads to manifold least-squares Petrov–Galerkin (LSPG) projection. We perform analyses that provide insight into the relationship between these proposed approaches and classical linear-subspace reduced-order models; we also derive a posteriori discrete-time error bounds for the proposed approaches. In addition, we propose a computationally practical approach for computing the nonlinear manifold, which is based on convolutional autoencoders from deep learning. Lastly, we demonstrate the ability of the method to significantly outperform even the optimal linear-subspace ROM on benchmark advection-dominated problems, thereby demonstrating the method's ability to overcome the intrinsic n -width limitations of linear subspaces.

97 MATHEMATICS AND COMPUTING↗

WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of {sup 18}F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of {sup 18}F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in {sup 18}F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. {sup 18}F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of limited cardiac irradiation show evidence of a persistent global inflammatory response that can be detected using {sup 18}F-FDG PET imaging. This work was supported through the Translational Breast Cancer Studentship award, funded in part by the Breast Cancer Society of Canada. Additional financial support is provided by the London Regional Cancer Program Catalyst Grant and the Thames Valley Veterinary Services.

60 APPLIED LIFE SCIENCES↗

Effect of Body Mass Index on Magnitude of Setup Errors in Patients Treated With Adjuvant Radiotherapy for Endometrial Cancer With Daily Image Guidance

Purpose: To determine the impact of body mass index (BMI) on daily setup variations and frequency of imaging necessary for patients with endometrial cancer treated with adjuvant intensity-modulated radiotherapy (IMRT) with daily image guidance. Methods and Materials: The daily shifts from a total of 782 orthogonal kilovoltage images from 30 patients who received pelvic IMRT between July 2008 and August 2010 were analyzed. The BMI, mean daily shifts, and random and systematic errors in each translational and rotational direction were calculated for each patient. Margin recipes were generated based on BMI. Linear regression and spearman rank correlation analysis were performed. To simulate a less-than-daily IGRT protocol, the average shift of the first five fractions was applied to subsequent setups without IGRT for assessing the impact on setup error and margin requirements. Results: Median BMI was 32.9 (range, 23-62). Of the 30 patients, 16.7% (n = 5) were normal weight (BMI <25); 23.3% (n = 7) were overweight (BMI {>=}25 to <30); 26.7% (n = 8) were mildly obese (BMI {>=}30 to <35); and 33.3% (n = 10) were moderately to severely obese (BMI {>=} 35). On linear regression, mean absolute vertical, longitudinal, and lateral shifts positively correlated with BMI (p = 0.0127, p = 0.0037, and p < 0.0001, respectively). Systematic errors in the longitudinal and vertical direction were found to be positively correlated with BMI category (p < 0.0001 for both). IGRT for the first five fractions, followed by correction of the mean error for all subsequent fractions, led to a substantial reduction in setup error and resultant margin requirement overall compared with no IGRT. Conclusions: Daily shifts, systematic errors, and margin requirements were greatest in obese patients. For women who are normal or overweight, a planning target margin margin of 7 to 10 mm may be sufficient without IGRT, but for patients who are moderately or severely obese, this is insufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microgrid Optimal Scheduling With Chance-Constrained Islanding Capability

To facilitate the integration of variable renewable generation and improve the resilience of electricity sup-ply in a microgrid, this paper proposes an optimal scheduling strategy for microgrid operation considering constraints of islanding capability. A new concept, probability of successful islanding (PSI), indicating the probability that a microgrid maintains enough spinning reserve (both up and down) to meet local demand and accommodate local renewable generation after instantaneously islanding from the main grid, is developed. The PSI is formulated as mixed-integer linear program using multi-interval approximation taking into account the probability distributions of forecast errors of wind, PV and load. With the goal of minimizing the total operating cost while preserving user specified PSI, a chance-constrained optimization problem is formulated for the optimal scheduling of mirogrids and solved by mixed integer linear programming (MILP). Numerical simulations on a microgrid consisting of a wind turbine, a PV panel, a fuel cell, a micro-turbine, a diesel generator and a battery demonstrate the effectiveness of the proposed scheduling strategy. Lastly, we verify the relationship between PSI and various factors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using an external surrogate for predictor model training in real-time motion management of lung tumors

Purpose: Precise prediction of respiratory motion is a prerequisite for real-time motion compensation techniques such as beam, dynamic couch, or dynamic multileaf collimator tracking. Collection of tumor motion data to train the prediction model is required for most algorithms. To avoid exposure of patients to additional dose from imaging during this procedure, the feasibility of training a linear respiratory motion prediction model with an external surrogate signal is investigated and its performance benchmarked against training the model with tumor positions directly. Methods: The authors implement a lung tumor motion prediction algorithm based on linear ridge regression that is suitable to overcome system latencies up to about 300 ms. Its performance is investigated on a data set of 91 patient breathing trajectories recorded from fiducial marker tracking during radiotherapy delivery to the lung of ten patients. The expected 3D geometric error is quantified as a function of predictor lookahead time, signal sampling frequency and history vector length. Additionally, adaptive model retraining is evaluated, i.e., repeatedly updating the prediction model after initial training. Training length for this is gradually increased with incoming (internal) data availability. To assess practical feasibility model calculation times as well as various minimum data lengths for retraining are evaluated. Relative performance of model training with external surrogate motion data versus tumor motion data is evaluated. However, an internal–external motion correlation model is not utilized, i.e., prediction is solely driven by internal motion in both cases. Results: Similar prediction performance was achieved for training the model with external surrogate data versus internal (tumor motion) data. Adaptive model retraining can substantially boost performance in the case of external surrogate training while it has little impact for training with internal motion data. A minimum adaptive retraining data length of 8 s and history vector length of 3 s achieve maximal performance. Sampling frequency appears to have little impact on performance confirming previously published work. By using the linear predictor, a relative geometric 3D error reduction of about 50% was achieved (using adaptive retraining, a history vector length of 3 s and with results averaged over all investigated lookahead times and signal sampling frequencies). The absolute mean error could be reduced from (2.0 ± 1.6) mm when using no prediction at all to (0.9 ± 0.8) mm and (1.0 ± 0.9) mm when using the predictor trained with internal tumor motion training data and external surrogate motion training data, respectively (for a typical lookahead time of 250 ms and sampling frequency of 15 Hz). Conclusions: A linear prediction model can reduce latency induced tracking errors by an average of about 50% in real-time image guided radiotherapy systems with system latencies of up to 300 ms. Training a linear model for lung tumor motion prediction with an external surrogate signal alone is feasible and results in similar performance as training with (internal) tumor motion. Particularly for scenarios where motion data are extracted from fluoroscopic imaging with ionizing radiation, this may alleviate the need for additional imaging dose during the collection of model training data.

60 APPLIED LIFE SCIENCES↗

POWER OF OBSERVATIONAL HUBBLE PARAMETER DATA: A FIGURE OF MERIT EXPLORATION

We use simulated Hubble parameter data in the redshift range 0 {<=} z {<=} 2 to explore the role and power of observational H(z) data in constraining cosmological parameters of the {Lambda}CDM model. The error model of the simulated data is empirically constructed from available measurements and scales linearly as z increases. By comparing the median figures of merit calculated from simulated data sets with that of current Type Ia supernova (SNIa) data, we find that as many as 64 further independent measurements of H(z) are needed to match the parameter constraining power of SNIa. If the error of H(z) could be lowered to 3%, the same number of future measurements would be needed, but then the redshift coverage would only be required to reach z = 1. We also show that accurate measurements of the Hubble constant H{sub 0} can be used as priors to increase the H(z) data's figure of merit.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of exposure estimation errors on estimated exposure-response relations for PM2.5

Highlights: • Recent literature has identified associations between concentrations of fine particulate matter (PM2.5) in ambient air and adverse health effects at estimated exposure concentrations below current air ambient quality standards. • The models and analyses used do not usually quantify uncertainty about exposure estimates. • Realistic errors in exposure estimates can be estimated from available air quality monitoring stations by predicting concentrations at each station from concentrations at neighboring stations. • Exposure estimation errors are large enough to obscure low-dose nonlinearities or thresholds in the true concentration-response (C-R) function, artificially making them appear to be linear at low doses. • Better estimates of C-R functions will require modeling exposure distributions and estimation errors, rather than just estimating average exposure concentrations. Associations between fine particulate matter (PM2.5) exposure concentrations and a wide variety of undesirable outcomes, from autism and auto theft to elderly mortality, suicide, and violent crime, have been widely reported. Influential articles have argued that reducing National Ambient Air Quality Standards for PM2.5 is desirable to reduce these outcomes. Yet, other studies have found that reducing black smoke and other particulate matter by as much as 70% and dozens of micrograms per cubic meter has not detectably affected all-cause mortality rates even after decades, despite strong, statistically significant positive exposure concentration-response (C-R) associations between them. This paper examines whether this disconnect between association and causation might be explained in part by ignored estimation errors in estimated exposure concentrations. We use EPA air quality monitor data from the Los Angeles area of California to examine the shapes of estimated C-R functions for PM2.5 when the true C-R functions are assumed to be step functions with well-defined response thresholds. The estimated C-R functions mistakenly show risk as smoothly increasing with concentrations even well below the response thresholds, thus incorrectly predicting substantial risk reductions from reductions in concentrations that do not affect health risks. We conclude that ignored estimation errors obscure the shapes of true C-R functions, including possible thresholds, possibly leading to unrealistic predictions of the changes in risk caused by changing exposures. Instead of estimating improvements in public health per unit reduction (e.g., per 10 µg/m{sup 3} decrease) in average PM2.5 concentrations, it may be essential to consider how interventions change the distributions of exposure concentrations.

54 ENVIRONMENTAL SCIENCES↗