Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Time resolved photo-luminescent decay characterization of mercury cadmium telluride focal plane arrays

The minority carrier lifetime is a measurable material property that is an indication of infrared detector device performance. To study the utility of measuring the carrier lifetime, an experiment has been constructed that can time resolve the photo-luminescent decay of a detector or wafer sample housed inside a liquid nitrogen cooled Dewar. Motorized stages allow the measurement to be scanned over the sample surface, and spatial resolutions as low as 50µm have been demonstrated. A carrier recombination simulation was developed to analyze the experimental data. Results from measurements performed on 4 mercury cadmium telluride focal plane arrays show strong correlation between spatial maps of the lifetime, dark current, and relative response.

36 MATERIALS SCIENCE↗

DEVELOPMENT OF METHODOLOGY AND FIELD DEPLOYABLE SAMPLING TOOLS FOR SPENT NUCLEAR FUEL INTERROGATION IN LIQUID STORAGE

This project developed methodology and field deployable tools (test kits) to analyze the chemical and microbiological condition of the fuel storage medium and determine the oxide thickness on the spent fuel basin materials. The overall objective of this project was to determine the amount of time fuel has spent in a storage basin to determine if the operation of the reactor and storage basin is consistent with safeguard declarations or expectations. This project developed and validated forensic tools that can be used to predict the age and condition of spent nuclear fuels stored in liquid basins based on key physical, chemical and microbiological basin characteristics. Key parameters were identified based on a literature review, the parameters were used to design test cells for corrosion analyses, tools were purchased to analyze the key parameters, and these were used to characterize an active spent fuel basin, the Savannah River Site (SRS) L-Area basin. The key parameters identified in the literature review included chloride concentration, conductivity, and total organic carbon level. Focus was also placed on aluminum based cladding because of their application to weapons production. The literature review was helpful in identifying important parameters, but relationships between these parameters and corrosion rates were not available. Bench scale test systems were designed, operated, harvested, and analyzed to determine corrosion relationships between water parameters and water conditions, chemistry and microbiological conditions. The data from the bench scale system indicated that corrosion rates were dependent on total organic carbon levels and chloride concentrations. The highest corrosion rates were observed in test cells amended with sediment, a large microbial inoculum and an organic carbon source. A complete characterization test kit was field tested to characterize the SRS L-Area spent fuel basin. The sampling kit consisted of a TOC analyzer, a YSI multiprobe, and a thickness probe. The tools were field tested to determine their ease of use, reliability, and determine the quality of data that each tool could provide. Characterization was done over a two day period in June 2011, and confirmed that the L Area basin is a well operated facility with low corrosion potential.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cryogenic immersion microscope

A cryogenic immersion microscope whose objective lens is at least partially in contact with a liquid reservoir of a cryogenic liquid, in which reservoir a sample of interest is immersed is disclosed. When the cryogenic liquid has an index of refraction that reduces refraction at interfaces between the lens and the sample, overall resolution and image quality are improved. A combination of an immersion microscope and x-ray microscope, suitable for imaging at cryogenic temperatures is also disclosed.

Le Gros, Mark↗

Automated position control of a surface array relative to a liquid microjunction surface sampler

A system and method utilizes an image analysis approach for controlling the probe-to-surface distance of a liquid junction-based surface sampling system for use with mass spectrometric detection. Such an approach enables a hands-free formation of the liquid microjunction used to sample solution composition from the surface and for re-optimization, as necessary, of the microjunction thickness during a surface scan to achieve a fully automated surface sampling system.

Van Berkel, Gary J↗

Identifying structural changes with unsupervised machine learning methods

In this work, unsupervised machine learning methods are used to identify structural changes using the melting point transition in classical molecular dynamics simulations as an example application of the approach. Dimensionality reduction and clustering methods are applied to instantaneous radial distributions of atomic configurations from classical molecular dynamics simulations of metallic systems over a large temperature range. Principal component analysis is used to dramatically reduce the dimensionality of the feature space across the samples using an orthogonal linear transformation that preserves the statistical variance of the data under the condition that the new feature space is linearly independent. From there, k-means clustering is used to partition the samples into solid and liquid phases through a criterion motivated by the geometry of the reduced feature space of the samples, allowing for an estimation of the melting point transition. This pattern criterion is conceptually similar to how humans interpret the data but with far greater throughput, as the shapes of the radial distributions are different for each phase and easily distinguishable by humans. The transition temperature estimates derived from this machine learning approach produce comparable results to other methods on similarly small system sizes. These results show that machine learning approaches can be applied to structural changes in physical systems.

42 ENGINEERING↗

Additional Analysis of the 2H-Evaporator Wall Scale Sample HTF-17-57

Savannah River National Laboratory previously analyzed scale samples from both the wall and cone sections of the 242-16H Evaporator prior to chemical cleaning. The samples were analyzed for uranium and plutonium isotopes required for a Nuclear Criticality Safety Assessment of the scale removal process. The analysis of the scale samples found the material to contain crystalline nitrated cancrinite and clarkeite and significant amounts of mercury. Savannah River Remediation subsequently requested additional analyses on the samples. Inspection of the sample bottles revealed that no sample remained of the cone scale (HTF-17-56) while approximately 4 g of the wall scale sample (HTF-17-57) remained. The wall sample was subsequently ground with a mortar and pestle, at which time it was discovered that the sample contained a significant amount of liquid, metallic mercury. The portion of the sample that was not mercury was approximately 3 g. This portion of the sample was analyzed to determine the concentrations of selected radionuclides. The following radionuclide concentrations were measured: <9.6E+02 dpm/g H-3, 2.9E+02 dpm/g C-14, 5.6E+03 dpm/g Tc-99, and 1.6E+02 dpm/g I-129. Blank samples were also analyzed to evaluate sample contamination from the Shielded Cells environment. All blank sample results were below detectable limits. Due to the limited sample size and the anticipated low levels of the target radionuclides, no replicate sample analysis was conducted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of LIBS Acquisition Parameters for Chemical Analysis on HLW Liquid Solution - 18291

Research programs are currently underway in the Joint CEA-AREVA Vitrification Laboratory (LCV) to develop and optimize Laser Induced Breakdown Spectroscopy (LIBS) for nuclear waste streams analyses. The laboratory has full scale prototypes with the advantage of working on simulated inactive solutions of fission products. LIBS is an elemental chemical analysis technology that uses a short laser pulse to create a micro-plasma on the sample surface. This analytical technique offers many advantages compared to other techniques. It includes a sample preparation-free measurement and an extremely fast measurement time, from a few seconds to a few minutes. This paper presents the LIBS technique available in the laboratory. The first LIBS analyzes results of liquid samples from the off-gas treatment unit integrated on the full scale vitrification process are also presented and discussed. These complex solutions contain suspended particles and up to 30 chemical elements. A vision of an online LIBS analysis cell is also proposed with the development and associated research steps. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inactivation of Fluorescent Lipid Bilayers by Irradiation With 300 keV Electrons Using Liquid Cell Transmission Electron Microscopy

Liquid cell transmission electron microscopy allows for imaging of samples in a fully hydrated state at high resolution and has the potential for visualizing static or dynamic biological structures. However, the ionizing nature of the electron beam makes it difficult to discern real physiological dynamics from radiation induced artifacts within liquid cell samples. Electron flux thresholds for achieving high resolution structures from biological samples frozen in ice have been described extensively by the cryo-electron microscopy field, while electron flux thresholds which do not result in a functional change for biological samples within the hydrated environment of a transmission electron microscope liquid cell is less clear. Establishing these functional thresholds for biologically relevant samples is important for accurate interpretation of results from liquid cell experiments. Here we demonstrate the electron damage threshold of fluorescently tagged lipid bilayers by quantifying the change in fluorescence before and after electron exposure. We observe the reduction of fluorescent signal in bilayers by 25% after only 0.0005 e − /Å 2 and a reduction of over 90% after 0.01 e − /Å 2 . These results indicate that the loss of function occurs at irradiation thresholds far below a typical single high resolution (scanning) transmission electron microscopy image and orders of magnitude below fluxes used for preserving structural features with cryo-electron microscopy.

Moser, Trevor↗

NIR Dataset and Models (Near-Infrared Spectroscopy Calibration Dataset for Butanediol Fermentation and Multivariate Calibration Models) [SWR-22-60]

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be used in a variety of chemical feedstocks, liquid fuels, and biosynthetic building blocks. While 2,3-BDO can be efficiently produced by fermentation, the fermentation requires continuous monitoring and control to maximize 2,3-BDO yields and minimize inhibitory coproducts. Because of the time required for sampling and at-line measurement of fermentation samples with high pressure liquid chromatography (HPLC), the ability for operators to perform real-time modification to fermentation conditions is limited. To overcome this challenge, researchers from the National Renewable Energy Laboratory (NREL) have developed a calibration model which can predict the concentration of several analytes in real-time using near-infrared (NIR) spectra of the filtered fermentation broth. While significantly reducing the need for off-line sampling, NREL expects this technology to play a critical role in maximizing 2,3-BDO production. 2,3-butanediol (2,3-BDO) is a useful chemical platform that can be used to create a variety of products. For instance, 2,3-BDO can be (1) dehydrated and converted into methyl ethyl ketone, a liquid fuel additive or (2) deoxydehydrated into 1,3-butadiene for synthetic rubber, which can also be oligomerized in high yields to gasoline, diesel, and jet fuel. In order to maximize 2,3-BDO production, frequent measurement of fermentation samples is needed, as small changes in oxygen concentration can drive the fermentation to undesired products. For example, oxygen-deficient conditions result in glycerol production, while excess oxygen concentrations result in acetoin production. This results in the need for measuring dissolved oxygen, glucose, and xylose concentrations in order to optimize the aeration rate of the fermentation. Traditional monitoring methods occurs off-line and can take up to 30 minutes per sample. With multiple fermenters and high-pressure liquid chromatography (HPLC) injectors, resulting in the need for multiple samples, the sampling process can take hours to complete. NREL’s calibration model can predict the glucose, xylose, 2,3-BDO, acetoin, and glycerol concentrations from NIR spectra of filtered fermentation liquor samples. Using a partial least-squares (PLS) calibration model, NREL’s model can monitor the concentration of these analytes during subsequent fermentations at bench- and pilot-scale, demonstrating the utility of NIR spectroscopy combined with chemometrics for real-time, at-line monitoring of 2,3-BDO fermentations.

Wolfrum, Edward↗

Preparation and Analysis of Biomass Lignins

Lignin, comprised primarily of three randomly polymerized phenylpropenyl monomers, is, arguably, the second most common organic molecule on earth. In current biorefinery applications, lignin is burned, usually in concentrated pulping or hydrolysis liquor, as a source of process steam and both internal and exported electricity. The aromatic content of lignin makes it a potentially attractive feedstock for highly-valued aromatic chemicals, polymers, and carbon products (graphite, activated carbon, and carbon fiber). Revenue from production of lignin-based chemicals could play a major role in biorefinery profitability if cost-effective methods for lignin separation and purification can be developed. This article presents descriptions of methods for assessing and purifying biorefinery lignins so that they can be evaluated for use as feedstocks for production of chemical products. Areas covered are: 1) initial evaluations of as-received lignin samples (visual, microscopic, separable organics), 2) analysis of common contaminants (bulk and filterable ash and particulate contaminants in liquid and dry lignin samples), 3) preparation of lignins for experimental use as chemical feedstocks (prefiltration, filtration using bench-scale chemical apparatus and larger scale bag filters, one-step lignin precipitation, two-step carbohydrate and lignin precipitation, desalting of dry powdered or precipitated lignin, and lyophilization). These methods have been used successfully at bench-scale to produce the 1 50 kg amounts of wood and grass lignins typically required for bench-scale assessment as chemical feedstocks

09 BIOMASS FUELS↗

Modular automated bottom-up proteomic sample preparation for high-throughput applications

Manual proteomic sample preparation methods limit sample throughput and often lead to poor data quality when thousands of samples must be analyzed. Automated liquid handler systems are increasingly used to overcome these issues for many of the sample preparation steps. Here, we detail a step-by-step protocol to prepare samples for bottom-up proteomic analysis for Gram-negative bacterial and fungal cells. The full modular protocol consists of three optimized protocols to: (A) lyse Gram-negative bacteria and fungal cells; (B) quantify the amount of protein extracted; and (C) normalize the amount of protein and set up tryptic digestion. These protocols have been developed to facilitate rapid, low variance sample preparation of hundreds of samples, be easily implemented on widely-available Beckman-Coulter Biomek automated liquid handlers, and allow flexibility for future protocol development. By using this workflow 50 micrograms of protein from 96 samples can be prepared for tryptic digestion in under an hour. We validate these protocols by analyzing 47 Pseudomonas putida and Rhodosporidium toruloides samples and show that this modular workflow provides robust, reproducible proteomic samples for high-throughput applications. The expected results from these protocols are 94 peptide samples from Gram-negative bacterial and fungal cells prepared for bottom-up quantitative proteomic analysis without the need for desalting column cleanup and with protein relative quantity variance (CV%) below 15%.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet

A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IR-Live: fabrication of a low-cost plastic microfluidic device for infrared spectromicroscopy of living cells

Water is a strong mid-infrared absorber, which has hindered the full exploitation of label-free and non-invasive infrared (IR) spectromicroscopy techniques for the study of living biological samples. To overcome this barrier, many researchers have built sophisticated fluidic chambers or microfluidic chips wherein the depth of the liquid medium in the sample compartment is limited to 10 μm or less. We report an innovative and simple way to fabricate plastic devices with infrared transparent view-ports enabling infrared spectromicroscopy of living biological samples; therefore the device is named “IR-Live”. Advantages of this approach include lower production costs, a minimal need to access a micro-fabrication facility, and unlimited mass or waste exchange for the living samples surrounding the view-port area. We demonstrate that the low-cost IR-Live in combination with microfluidic perfusion techniques enables long term (>60 h) cell culture, which broadens the capability of IR spectromicroscopy for studying living biological samples. To illustrate this, we first applied the device to study protein and lipid polarity in migrating REF52 fibroblasts by collecting 2-dimensional spectral chemical maps at a micrometer spatial resolution. Then, we demonstrated the suitability of our approach to study dynamic cellular events by collecting a time series of spectral maps of U937 monocytes during the early stage of cell attachment to a bio-compatible surface.

47 OTHER INSTRUMENTATION↗

Letter Report for Analytical Results for Two Soil Samples Associated with the Westinghouse Hematite Decommisioning Project in Hematite Missouri

Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, received two soil samples on September 26, 2013 from the Westinghouse Hetnatite Decomminsioning project in Hematite, Missouri. The samples were analyzed for thorium-232, radium-226, uranium-235, and uranium-238 by gamma spectrometry and technetium-99 by liquid scintillation analysis. The samples were received in good condition. The sample collection data and identification numbers are tabulated. Also presented are the gamma spectrometry and technetium-99 data, respectively. The pertinent procedure references are included with the data tables.

54 ENVIRONMENTAL SCIENCES↗

Results from the Second MCU Flush DSSHT Sample

The Modular Caustic-Side Solvent Extraction Unit (MCU) stopped operations on May 22, 2019. As part of a plan to de-inventory the remainder of the liquids in the system, samples are sent to the Savannah River National Laboratory (SRNL) for analysis. A recent set of samples was pulled from the Decontaminated Salt Solution (DSS) Hold Tank (DSSHT) on 6/25/21, and arrived on the same day. The current DSSHT contents includes heel from the first flush of DSSHT (reference SRNL-L3100-2021-00019), deionized water (DIW) backflush of the DSS Coalescer, DIW flushes of the DSS Hydraulic Accumulator (DSSHA), DIW flush of the Contactor Drain Tank (CDT), and DSS Decanter drain material. The DIW flushes from the coalescer, DSSHA, and CDT were pumped through the DSS Decanter to allow for flushing of the DSS Decanter.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microfluidic electrochemical device and process for chemical imaging and electrochemical analysis at the electrode-liquid interface in-situ

A microfluidic electrochemical device and process are detailed that provide chemical imaging and electrochemical analysis under vacuum at the surface of the electrode-sample or electrode-liquid interface in-situ. The electrochemical device allows investigation of various surface layers including diffuse layers at selected depths populated with, e.g., adsorbed molecules in which chemical transformation in electrolyte solutions occurs.

36 MATERIALS SCIENCE↗

Microfluidic electrochemical device and process for chemical imaging and electrochemical analysis at the electrode-liquid interface in-situ

A microfluidic electrochemical device and process are detailed that provide chemical imaging and electrochemical analysis under vacuum at the surface of the electrode-sample or electrode-liquid interface in-situ. The electrochemical device allows investigation of various surface layers including diffuse layers at selected depths populated with, e.g., adsorbed molecules in which chemical transformation in electrolyte solutions occurs.

42 ENGINEERING↗

Single-Grain Bulk YBa{sub 2}Cu{sub 3}O{sub y} Superconductors Grown by Infiltration Growth Process Utilizing the YbBa{sub 2}Cu{sub 3}O{sub y} + Liquid Phase as a Liquid Source

The top-seeded infiltration growth (IG) processed YBa{sub 2}Cu{sub 3}O{sub y} (Y-123) has several advantages compared to the same material produced by other melt process techniques. There is usually no shrinkage, a limited number of pores, and an uniform secondary phase particle dispersion in the Y-123 matrix. These characteristics of the IG process are very attractive for several industrial applications. In this paper, we produced a large single-grain Y-123 by IG and top seeded melt-growth process. Utilizing commercial YbBa{sub 2}Cu{sub 3}O{sub y} (Yb-123) and a homemade Y{sub 2}BaCuO{sub 5} (Y-211), we produced bulk YBa{sub 2}Cu{sub 3}O{sub y} samples using Yb-123 + liquid (1:1) as a liquid source. Four facet lines on the top surfaces of the as-grown samples indicated a uniform growth from the seed up to sample edges. Magnetization measurements by SQUID magnetometer showed a sharp superconducting transition with T{sub c},{sub onset} at 92.1 K. The critical current density at 77 K and self-field was 39,000 A/cm{sup 2}. Trapped field results confirmed that single grain Y-123 samples were produced utilizing the above process. Our results prove that Yb-123 + liquid (1:1) as a liquid source is effective in producing single grain Y-123 material by IG process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗