Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Shifting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Effect of K loadings on nitrate formation/decomposition and on NOx storage performance of K-based NOx storage-reduction catalysts

We have investigated nitrate formation and decomposition processes, and measured NOx storage performance on Pt-K2O/Al2O3 catalysts as a function of potassium loading. After NO2 adsorption at room temperature, ionic and bidentate nitrates were observed by fourier transform infra-red (FTIR) spectroscopy. The ratio of the former to the latter species increased with increasing potassium loading up to 10 wt%, and then stayed almost constant with additional K, demonstrating a clear dependence of loading on the morphology of the K species. Although both K2O(10)/Al2O3 and K2O(20)/Al2O3 samples have similar nitrate species after NO2 adsorption, the latter has more thermally stable nitrate species as evidenced by FTIR and NO2 temperature programmed desorption (TPD) results. With regard to NOx storage performance, the temperature of maximum NOx uptake (Tmax) is 573 K up to a potassium loading of 10 wt%. As the potassium loading increases from 10 wt% to 20 wt%, Tmax shifted from 573 K to 723 K. Moreover, the amount of NO uptake (38 cm3 NOx/g catal) at Tmax increased more than three times, indicating that efficiency of K in storing NOx is enhanced significantly at higher temperature, in good agreement with the NO2 TPD and FTIR results. Thus, a combination of characterization and NOx storage performance results demonstrates an unexpected effect of potassium loading on nitrate formation and decomposition processes; results important for developing Pt-K2O/Al2O3 for potential applications as high temperature NOx storage-reduction catalysts.

Environmental Molecular Sciences Laboratory↗

Microstructure Clones

Background: A material’s microstructure drives its material performance. Contemporary crystal plasticity experiments compare full-field strain measurements of polycrystal specimens to models. Because each specimen is unique, it is impossible to know which features of the observed deformation are deterministic vs statistical; thus, differences between model and experiment may or may not be significant. Objective: This paper introduces the invention of microstructure clones. Microstructure clones are 2D oligocrystal specimens that have nearly identical microstructures to remedy the aforementioned experimental limitations. Having specimens with nearly identical microstructures will allow for multiple destructive tests of a microstructure (either as repeats or intentionally different experiments), an ability to “see the future” by providing insight into how a specimen will deform, variability quantification, and experimental investigations of response to small microstructural changes. Methods: This work introduces microstructure clones. Repeatability of these clones is demonstrated in tensile bars of pure nickel. Local strain measurements from digital image correlation are compared between clone specimens and compared to results from a crystal plasticity finite element model. Results: Two sets of microstructure clones were tested in this study and displayed very consistent deformation responses within each clone set. Small observed differences in deformation invite investigation into microstructure stochasticity and the effect of small microstructural and loading differences. Conclusions: Microstructure clones represent a significant shift in understanding structure–property relationships. This work reshapes experimental crystal plasticity to allow for experiments that control for specific variables, quantification of microstructural stochasticity (and other sources of stochasticity), and opportunities for replicating experiments.

Crystal Plasticity↗

Predicting the counter-intuitive stress relaxation behavior of glass forming materials

The ability to relax a macroscopically applied stress is often associated with molecular mobility, or the possibility for a molecule to move outside the confines of its current position, within the material of which the stress is applied. In this paper, a viscoelastic constitutive analysis is used to investigate the counter-intuitive experimental observation of “mobility decrease with increased deformation through yield” for a glass forming polymer during stress relaxation while under compressive and tensile loading conditions. The behavior of an epoxy thermoset is examined using an extensively validated, thermorheologically simple, material “clock” model, the Simplified Potential Energy Clock (SPEC) model. This methodology allows for a comparison between the linear viscoelastic (LVE) limit and the true non-linear viscoelastic (NLVE) representation and enables exploration of a wide range of conditions that are not practical to investigate experimentally. The model predicts the behavior previously described as “mobility decrease with increased deformation” in the LVE limit and at low strain rates for NLVE. Only when loading rates are sufficient to decrease the material shift factor by multiple orders of magnitude is the anticipated deformation induced mobility or “mobility increase with increased deformation” observed. While the model has not been “trained” for these behaviors, it also predicts that the normalized stress relaxation response is indistinguishable amongst strain levels in the “post-yield” region, as has been experimentally reported. At long time, which has not been examined experimentally, the model predicts that even the normalized relaxation curves that exhibit “mobility increase with increased deformation” “cross back over” and return to the LVE ordering. Finally, these findings demonstrate the ability of rheologically simple models to represent the counter-intuitive experimentally measured material response and present predictions at long time scales that could be tested experimentally.

36 MATERIALS SCIENCE↗

MOSFIRE and LDSS3 spectroscopy for an [O II] Blob at z = 1.18: gas outflow and energy source

We report our Keck/MOSFIRE and Magellan/Low-Dispersion Survey Spectrograph spectroscopy for an [O II] Blob, O II B 10, that is a high-z galaxy with spatially extended [O II] λλ3726, 3729 emission over 30 kpc recently identified by a Subaru large-area narrowband survey. The systemic redshift of O II B 10 is z = 1.18 securely determined with [O III] λλ4959, 5007 and Hβ emission lines. We identify Fe II λ2587 and Mg II λλ2796, 2804 absorption lines blueshifted from the systemic redshift by 80 ± 50 and 260 ± 40 km s{sup –1}, respectively, which indicates gas outflow from O II B 10 with the velocity of ∼80-260 km s{sup –1}. This outflow velocity is comparable with the escape velocity, 250 ± 140 km s{sup –1}, estimated under the assumption of a singular isothermal halo potential profile. Some fraction of the outflowing gas could escape from the halo of O II B 10, suppressing O II B 10's star-formation (SF) activity. We estimate a mass loading factor, η, that is a ratio of mass outflow rate to SF rate, and obtain η > 0.8 ± 0.1, which is relatively high compared with low-z starbursts including U/LIRGs and active galactic nuclei (AGNs). The major energy source of the outflow is unclear with the available data. Although no signature of AGNs is found in the X-ray data, O II B 10 falls in the AGN/star-forming composite region in the line diagnostic diagrams. It is possible that the outflow is powered by SF and a type-2 AGN with narrow FWHM emission line widths of 70-130 km s{sup –1}. This is the first detailed spectroscopic study of oxygen-line blobs that includes analyses of the escape velocity, the mass loading factor, and the presence of an AGN, and is a significant step to understanding the nature of oxygen-line blobs and the relation between gas outflow and SF quenching at high redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

FAINT CO LINE WINGS IN FOUR STAR-FORMING (ULTRA)LUMINOUS INFRARED GALAXIES

We report the results of a search for large velocity width, low-intensity line wings—a commonly used signature of molecular outflows—in four low redshift (ultra)luminous infrared galaxies that appear to be dominated by star formation. The targets were drawn from a sample of fourteen targets presented in Chung et al., who showed the stacked CO spectrum of the sample to exhibit 1000 km s{sup −1}-wide line wings. We obtained sensitive, wide bandwidth imaging of our targets using the IRAM Plateau de Bure Interferometer. We detect each target at very high significance but do not find the claimed line wings in these four targets. Instead, we constrain the flux in the line wings to be only a few percent. Casting our results as mass outflow rates following Cicone et al. we show them to be consistent with a picture in which very high mass loading factors preferentially occur in systems with high active galactic nucleus contributions to their bolometric luminosity. We identify one of our targets, IRAS 05083 (VII Zw 31), as a candidate molecular outflow.

79 ASTRONOMY AND ASTROPHYSICS↗

Reliability of Aging Polymer Components

A viscoelastic constitutive analysis is used to investigate the counter-intuitive observation of “mobility decrease with increased deformation through yield” in a glass forming polymer under compressive and tensile loading conditions. Current Sandia National Laboratory polymer models are built on the assumption that deformation enhances the mobility of the material. If this assumption is not true at small strain rates (e.g., thermal fluctuations in stockpile storage) then models will not be able to accurately predict stress evolution and potential failure of components during stockpile storage. The behavior of an epoxy thermoset is explored using an extensively validated material “clock” model, the Simplified Potential Energy Clock (SPEC) model. This methodology allows for a comparison between the linear viscoelastic (LVE) limit and the true non-linear viscoelastic (NLVE) representation and enables exploration of a wide range of conditions that are not practical to explore experimentally. The model predicts the behavior described as “mobility decrease with increased deformation” in the LVE limit and at low strain rates for NLVE. Only when loading rates are sufficient to decrease the material shift factor by multiple orders of magnitude is the anticipated deformation induced mobility or “mobility increase with increased deformation” observed. While the model has not been “trained” for these behaviors, it also predicts that the normalized stress relaxation response is indistinguishable amongst strain levels in the “post-yield” region as has been experimentally reported. At long time, which has not been examined experimentally, the model predicts the normalized relaxation curves “crossover” and return to the LVE ordering. These findings further demonstrate the ability of rheologically simple models to represent experimentally measured material response and present predictions at long time scales that could be tested experimentally.

42 ENGINEERING↗

Computing Jet-Exhaust/Crossflow Interactions

JETPLT and JETBOD programs developed to predict velocity and pressure induced by subsonic jets exhausting into subsonic free stream. JETPLT predicts pressures induced on infinite flat plate by jet exhausting at angles to plate. JETBOD, in conjunction with panel code, predicts pressures induced on body of revolution by jet exhausting perpendicularly to surface. Programs used to investigate interactions between jet exhausts and crossflows in vertical/short-takeoff-andlanding aircraft shifting from hover to forward flight, where inducedpressure loading leads to reduction in lift. JETPLT/JETBOD written in FORTRAN 77.

Perkins, S. C., Jr.↗

Quantification of the memory imprint effect for a charged particle environment

The effects of total accumulated dose on the single-event vulnerability of NMOS resistive-load SRAMs are investigated. The bias-dependent shifts in device parameters can imprint the memory state present during exposure or erase the imprinted state. Analysis of these effects is presented along with an analytic model developed for the quantification of these effects. The results indicate that the imprint effect is dominated by the difference in the threshold voltage of the n-channel devices.

Bhuva, B. L.↗

Delivery-Risk-Aware Flexibility Scheduling and Dispatch for Aggregated Flexible Loads

Flexible loads like smart thermostats and water heaters can shift energy consumption and provide flexibility to the grid. However, this flexibility is dependent on occupant behavior and can lead to delivery risk, which causes utilities and grid operations to consider them as unreliable for purposes of grid operation. To date, they have not been well integrated into wholesale electricity markets or ancillary service offerings. With proper consideration of uncertainty and risk, these resources can be one of the most cost-effective sources of flexibility. This work uses stochastic optimization to quantify and bid flexibility from a fleet of flexible resources while considering their delivery risk.

DER↗

Stress dependence of ultrasonic velocity in unidirectional graphite/epoxy composites for longitudinal waves propagating along the direction of stress

Measurements of stress-induced velocity changes for propagation along the direction of applied stress in graphite/epoxy composites are presented. A linear relation between normalized velocity shift and stress is demonstrated for propagation and stress direction perpendicular to the fiber direction. The ratio of the SAC to the elastic compliance for this loading direction was assessed and found to have a value similar to that of numerous other materials which have very different linear elastic properties. Measurements with stress and propagation along the fibers yielded unusual behavior; the curves were very nonlinear and even shifted direction at higher loads.

Prosser, William H.↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Factors Influencing Dwell Fatigue Cracking in Notches of Powder Metallurgy Superalloys

The influences of heat treatment and cyclic dwells on the notch fatigue resistance of powder metallurgy disk superalloys were investigated for low solvus high refractory (LSHR) and ME3 disk alloys. Disks were processed to produce material conditions with varied microstructures and associated mechanical properties. Notched specimens were first subjected to baseline dwell fatigue cycles having a dwell at maximum load, as well as tensile, stress relaxation, creep rupture, and dwell fatigue crack growth tests at 704 C. Several material heat treatments displayed a bimodal distribution of fatigue life with the lives varying by two orders-of-magnitude, while others had more consistent fatigue lives. This response was compared to other mechanical properties, in search of correlations. The wide scatter in baseline dwell fatigue life was observed only for material conditions resistant to stress relaxation. For selected materials and conditions, additional tests were then performed with the dwells shifted in part or in total to minimum tensile load. The tests performed with dwells at minimum load exhibited lower fatigue lives than max dwell tests, and also exhibited early crack initiation and a substantial increase in the number of initiation sites. These results could be explained in part by modeling evolution of peak stresses in the notch with continued dwell fatigue cycling. Fatigue-environment interactions were determined to limit life for the fatigue cycles with dwells.

Gabb, T. P.↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

The effect of filler aspect ratio on the electromagnetic properties of carbon-nanofibers reinforced composites

The effect of filler aspect ratio on the electromagnetic properties of epoxy-amine resin reinforced with carbon nanofibers is here investigated. A heat treatment at 2500 °C of carbon nanofibers seems to increase their aspect ratio with respect to as-received ones most likely due to a lowering of structural defects and the improvement of the graphene layers within the dixie cup conformation. These morphological differences revealed by Raman's spectroscopy and scanning electron microscopy analyses may be responsible for the different electrical properties of the resulting composites. The DC characterization of the nanofilled material highlights an higher electrical conductivity and a lower electrical percolation threshold for the heat-treated carbon nanofibers based composites. In fact, the electrical conductivity is about 0.107 S/m and 1.36 × 10{sup −3} S/m for the nanocomposites reinforced with heat-treated and as received fibers, respectively, at 1 wt. % of nanofiller loading, while the electrical percolation threshold falls in the range [0.05–0.32]wt. % for the first nanocomposites and above 0.64 wt. % for the latter. Moreover, also a different frequency response is observed since the critical frequency, which is indicative of the transition from a resistive to a capacitive-type behaviour, shifts forward of about one decade at the same filler loading. The experimental results are supported by theoretical and simulation studies focused on the role of the filler aspect ratio on the electrical properties of the nanocomposites.

36 MATERIALS SCIENCE↗

Changing character of rainfall in eastern China, 1951–2007

The topography and continental configuration of East Asia favor the year-round existence of storm tracks that extend thousands of kilometers from China into the northwestern Pacific Ocean, producing zonally elongated patterns of rainfall that we call “frontal rain events.” In spring and early summer (known as “Meiyu Season”), frontal rainfall intensifies and shifts northward during a series of stages collectively known as the East Asian summer monsoon. Using a technique called the Frontal Rain Event Detection Algorithm, we create a daily catalog of all frontal rain events in east China during 1951–2007, quantify their attributes, and classify all rainfall on each day as either frontal, resulting from large-scale convergence, or nonfrontal, produced by local buoyancy, topography, or typhoons. Our climatology shows that the East Asian summer monsoon consists of a series of coupled changes in frontal rain event frequency, latitude, and daily accumulation. Furthermore, decadal changes in the amount and distribution of rainfall in east China are overwhelmingly due to changes in frontal rainfall. We attribute the “South Flood–North Drought” pattern observed beginning in the 1980s to changes in the frequency of frontal rain events, while the years 1994–2007 witnessed an uptick in event daily accumulation relative to the rest of the study years. This particular signature may reflect the relative impacts of global warming, aerosol loading, and natural variability on regional rainfall, potentially via shifting the East Asian jet stream.

54 ENVIRONMENTAL SCIENCES↗

Constant Frequency ZVS PWM Converter

In this paper, a simple yet novel buck or boost adaptive zero-voltage switching (ZVS) converter topology is proposed for soft switching pulse-width modulation (PWM) dc / dc converters. The converter is designed for the high switching frequency that can achieve high efficiency by reducing switching losses for the entire load range at low and high power. Besides, the output at the load terminals is maintained by a PWM signal at a fixed switching frequency, a phase shift signal between converter ports (legs) controls the system circulating current in order to provide the ZVS condition in all load conditions. With the proposed controller, the converter, thus, is suitable for high switching frequency and high-power applications with the small volume. The proposed dc / dc converter operation is analyzed, designed, and confirmed by simulation results for 240 V input, 400 V / 5 A output, and 200 kHz operating frequency at full load.

Asa, Erdem↗

Development of ceria-supported metal-oxide (MO x /CeO 2 ) catalysts via a one-pot chemical vapor deposition (OP-CVD) technique: Structure and reverse water gas shift reaction study

Current synthesis techniques for metal oxide (MO x )-supported catalysts have certain limitations of undesired target loading, ineffective dispersion of active species over the surface, uncontrolled particle size of active species, and complicated synthesis steps. Here, we developed a one-pot chemical vapor deposition (OP-CVD) methodology; by using which a solid metal precursor forms a vapor in a controlled condition and gets supported over the surrounding matrix. The theoretical stability followed by experimental validation using TGA is crucial for selecting the metal precursors. Three simple steps viz. premixing, dispersion, and rapid fixation by calcination are involved in the catalyst development via the OP-CVD approach. This study solely focused on the synthesis of 3d transition MO x over ceria support. The physicochemical characterizations of the prepared catalysts were performed by XRD, ICP-OES, SEM-EDX, CO pulse chemisorption, XANES, and EXAFS analyses to understand the crystal structure of involved species, target metal loading, dispersion, and particle size and prove the feasibility and viability of OP-CVD. The prepared catalysts were further tested for reverse water gas shift (RWGS) reaction to link their structural information with activity. The RWGS reaction data showed that the CO activity and CO selectivity were metal - and metal precursor-dependent. Higher CO activity of > 0.1 mol/h g-cat was observed for Cu and Co-based catalysts, with CO selectivity of ~100 %. This study provides an opportunity to produce efficient supported catalysts in a convenient way, providing effective catalytic activity.

36 MATERIALS SCIENCE↗

Descriptive Linear modeling of steady-state visual evoked response

A study is being conducted to explore use of the steady state visual-evoke electrocortical response as an indicator of cognitive task loading. Application of linear descriptive modeling to steady state Visual Evoked Response (VER) data is summarized. Two aspects of linear modeling are reviewed: (1) unwrapping the phase-shift portion of the frequency response, and (2) parsimonious characterization of task-loading effects in terms of changes in model parameters. Model-based phase unwrapping appears to be most reliable in applications, such as manual control, where theoretical models are available. Linear descriptive modeling of the VER has not yet been shown to provide consistent and readily interpretable results.

Levison, W. H.↗