Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC GUIDE FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

SU-G-JeP2-11: Polymer Gels as 3D QA Devices in Magnetic Resonance-Guided Radiation Therapy

Purpose: To demonstrate the potential of polymer gels to serve as 3D QA devices in MR-guided radiotherapy. Methods: Custom-designed polymer gel dosimeters (MGS Research, Madison, CT) were centered on the penumbras of a radiation field, parallel to the magnetic field lines inside a 1.5 T MR scanner integrated with a 7 MV linac (MR-Linac). 15 Gy were delivered perpendicular to the magnetic field. Coronal MR images were acquired with a 2D balanced-Fast Field Echo (b-FFE) sequence in real-time during irradiation and with a 2D spin echo sequence at different times after irradiation. Signal intensities (SI) were measured inside and outside the radiation field on b-FFE images obtained during irradiation. Spin-spin relaxation rate (R2) maps were calculated from images after irradiation and penumbra widths were calculated from these maps. Results: A difference in SI between areas of the dosimeter inside and outside of the radiation field could be measured immediately after the beam was turned on. The difference in SI increased throughout the duration of the exposure. R2 values from immediately after irradiation were 83% of those measured 24h post-irradiation. At 1h after irradiation, the R2 values were 87% of those at 24h indicating that polymerization of the gel was still ongoing. At 24h postirradiation the width of the 80/20 penumbra on the left field edge measured 6.5 mm and on the right 5.6 mm. Conclusion: The MR-Linac allows for MR imaging during treatment and measurements of 3D dose distributions with steep dose gradients without having to transfer dosimeters for read-out. The results showed promise for polymer gels as relative 3D QA devices to verify radiation treatment plans delivered by an MR-Linac. To our knowledge, this was the first time that polymer gels were used for real-time image acquisition. Further investigations into the application of polymer gel dosimetry on MR-Linac are ongoing.

60 APPLIED LIFE SCIENCES↗

Magnetic anisotropy in two-orbital models

Motivated by the recent first-principle discovery of giant perpendicular magnetic anisotropy (PMA) in Fe/III–V nitride thin films, we theoretically study magnetic crystalline anisotropy(MCA) in a series of lattices with trigonal symmetry. Due to the trigonal crystal field, MCA in these lattices is dominated by first-order perturbation of the spin–orbit coupling (SOC) in the atomic limit, instead of second-order in conventional transition metal materials. In particular, the proportionality between MCA and SOC is robust in Kagome and pyrochlore lattices due to the flat bands therein. While in triangle lattice the second-order relation is restored under the bandwidth effect. Furthermore, these findings give rise to a new understanding of magnetic anisotropy and provide a guide for the future hunting of high PMA materials.

36 MATERIALS SCIENCE↗

Effects of High Magnetic Fields on Phase Transformations in Amorphous Nd2Fe14B

We briefly summarize the results from a set of experiments designed to demonstrate the effects of high magnetic fields applied during thermal annealing of amorphous Nd2Fe14B produced through melt-spinning. A custom-built differential scanning calorimeter was used to determine the crystallization temperatures in zero-field and in applied fields of 20 kOe and 90 kOe, which guided subsequent heat treatments to evaluate phase evolution. X-ray diffraction was used for phase identification and transmission electron microscopy was employed for observation of the crystallite size and morphology. Magnetization measurements were also used to evaluate the resulting magnetic phases after thermomagnetic processing. While the applied magnetic fields do not appear to affect the crystallization temperature, significant effects on the kinetics of phase evolution are observed and correlated strongly to the magnetic behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent progress in tailoring trap-based positron beams

Recent progress is described to implement two approaches to specially tailor trap-based positron beams. Experiments and simulations are presented to understand the limits on the energy spread and pulse duration of positron beams extracted from a Penning-Malmberg (PM) trap after the particles have been buffer-gas cooled (or heated) in the range of temperatures 1000 {>=} T {>=} 300 K. These simulations are also used to predict beam performance for cryogenically cooled positrons. Experiments and simulations are also presented to understand the properties of beams formed when plasmas are tailored in a PM trap in a 5 tesla magnetic field, then non-adiabatically extracted from the field using a specially designed high-permeability grid to create a new class of electrostatically guided beams.

43 PARTICLE ACCELERATORS↗

Calculation of Last Closed Drift Shells for the 2013 GEM Radiation Belt Challenge Events

Radiation belt behavior is often analyzed in terms of adiabatic invariants, of which the third roughly characterizes the radial distance of particle drift shells. The outermost, or last closed drift shell, can be an important boundary for numerical modeling, especially for drift-averaged treatments such as three-dimensional diffusion codes. In this work, we discuss calculation of the last closed drift shell, using the widely used International Radiation Belt Environment Modeling (IRBEM) Library, the LanlGeoMag code, and a guiding center code named AFRL-Shell, in conjunction with a variety of current magnetic field models. Furthermore, we present results for the four events in 2013, comprising the radiation belt challenge organized by the Quantitative Assessment of Radiation Belt Modeling focus group of the Geospace Environment Modeling (GEM) program.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional stability of current sheets supported by electron pressure anisotropy

The stability of electron current sheets embedded within the reconnection exhaust is studied with a 3D fully kinetic particle-in-cell simulation. The electron current layers studied here form self-consistently in a reconnection regime with a moderate guide field, are supported by electron pressure anisotropy with the pressure component parallel to the magnetic field direction larger than the perpendicular components, and extend well beyond electron kinetic scales. In 3D, in addition to drift instabilities common to nearly all reconnection exhausts, the regime considered also exhibits an electromagnetic instability driven by the electron pressure anisotropy. While the fluctuations modulate the current density on small scales, they do not break apart the general structure of the extended electron current layers. Here, the elongated current sheets should therefore persist long enough to be observed both in space observations and in laboratory experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spontaneous onset of magnetic reconnection in toroidal plasma caused by breaking of 2D symmetry

Magnetic reconnection is studied in the collisionless limit at the Versatile Toroidal Facility (VTF) at MIT. Two distinct magnetic configurations are applied in the experiments; an open magnetic cusp and a closed cusp. In the open cusp configurations, the field lines intersect the the vacuum vessel walls and here axisymmetric oscillatory reconnection is observed. Meanwhile, in the closed cusp configuration, where the field lines are confined inside the experiment, the coupling between global modes and a current sheet leads to powerful bursts of 3D spontaneous reconnection. These spontaneous events start at one toroidal location, and then propagate around the toroidal direction at the Alfven speed (calculated with the strength of the dominant guide field). The three dimensional measurements include the detailed time evolution of the plasma density, current density, the magnetic flux function, the electrostatic potential, and the reconnection rate. The vastly different plasma behavior in the two configurations can be described using a simple theoretical framework, linking together the interdependencies of the reconnection rate, the in-plane electrostatic potential, and the parallel electron currents. We find that it is the breaking of toroidal symmetry by the global mode that allows for a localized disruption of the x-line current and hereby facilitates the onset of spontaneous reconnection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermoablation of Malignant Kidney Tumors Using Magnetic Nanoparticles: An In Vivo Feasibility Study in a Rabbit Model

The objective of this study was to assess the technical feasibility of CT-guided magnetic thermoablation for the treatment of malignant kidney tumors in a VX2 tumor rabbit model. VX2 tumors were implanted into the kidneys of five rabbits and allowed to grow for 2 weeks. After preinterventional CT perfusion imaging, CT-guided injection of superparamagnetic iron oxide particles (300 {mu}l) was performed, followed by exposure of the animals to an alternating electromagnetic field for 15 min ({approx}0.32 kA/m). Then animals underwent CT perfusion imaging again. Afterward, animals were sacrificed and kidneys were dissected for macroscopic and histological evaluation. Changes in perfusion before and after exposure to the alternating magnetic field were analyzed. In one animal no tumor growth could be detected so the animal was used for optimization of the ablation procedure including injection technique and peri-interventional cross-sectional imaging (CT, MRI). After image-guided intratumoral injection of ferrofluids, the depiction of nanoparticle distribution by CT correlated well with macroscopic evaluation of the dissected kidneys. MRI was limited due to severe susceptibility artefacts. Postinterventional CT perfusion imaging revealed a perfusion deficiency around the ferrofluid deposits. Histological workup showed different zones of thermal damage adjacent to the ferrofluid deposits. In conclusion, CT-guided magnetic thermoablation of malignant kidney tumors is technically feasible in an animal model and results in a perfusion deficiency indicating tumor necrosis as depicted by CT perfusion imaging and shown in histological evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficiency enhancement in free-electron laser amplifier with one dimensional helical wiggler and ion-channel guiding

A method for efficiency enhancement in free-electron laser is studied which uses both tapered wiggler magnetic field and ion-channel density. Derivation of a set of nonlinear and coupled differential equations leads to the self-consistent description of the evolution of both an ensemble of electrons and the electromagnetic radiation. Numerical solution of these equations reveals considerable enhancements of the interaction efficiency. In order to obtain a better insight into physical basis of the problem, a modified pendulum equation for the interaction is derived and a small signal theory of the efficiency enhancement is developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle energization in 3D magnetic reconnection of relativistic pair plasmas

We present large scale 3D particle-in-cell simulations to examine particle energization in magnetic reconnection of relativistic electron-positron (pair) plasmas. The initial configuration is set up as a relativistic Harris equilibrium without a guide field. These simulations are large enough to accommodate a sufficient number of tearing and kink modes. Contrary to the non-relativistic limit, the linear tearing instability is faster than the linear kink instability, at least in our specific parameters. We find that the magnetic energy dissipation is first facilitated by the tearing instability and followed by the secondary kink instability. Particles are mostly energized inside the magnetic islands during the tearing stage due to the spatially varying electric fields produced by the outflows from reconnection. Secondary kink instability leads to additional particle acceleration. Accelerated particles are, however, observed to be thermalized quickly. The large amplitude of the vertical magnetic field resulting from the tearing modes by the secondary kink modes further help thermalizing the non-thermal particles generated from the secondary kink instability. Implications of these results for astrophysics are briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compressible Hall magnetohydrodynamics in a strong magnetic field

Plasma dynamics becomes anisotropic in the presence of a strong background magnetic field, a feature that may be exploited to yield reduced fluid models. The reduced Hall-magnetohydrodynamics model derived in a recent work by Gomez et al. [Phys. Plasmas 15, 102303 (2008)], reflecting two-fluid effects such as the Hall current and the electron pressure, is extended to account for a crucial aspect of the role of the plasma compressibility, i.e., the compression of the guide field. This reduced model constitutes therefore a description of the two-fluid plasma dynamics in a strong external magnetic field, which can be used also for values of the plasma pressure parameter {beta} of the order of unity or smaller.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic nanoparticles for applications in oscillating magnetic field

Enzymatic and thermochemical catalysis are both important industrial processes. However, the thermal requirements for each process often render them mutually exclusive: thermochemical catalysis requires high temperature that denatures enzymes. One of the long-term goals of this project is to design a thermocatalytic system that could be used with enzymatic systems in situ to catalyze reaction sequences in one pot; this system would be useful for numerous applications e.g. conversion of biomass to biofuel and other commodity products. The desired thermocatalytic system would need to supply enough thermal energy to catalyze thermochemical reactions, while keeping the enzymes from high temperature denaturation. Magnetic nanoparticles are known to generate heat in an oscillating magnetic field through mechanisms including hysteresis and relaxational losses. We envisioned using these magnetic nanoparticles as the local heat source embedded in sub-micron size mesoporous support to spatially separate the particles from the enzymes. In this study, we set out to find the magnetic materials and instrumental conditions that are sufficient for this purpose. Magnetite was chosen as the first model magnetic material in this study because of its high magnetization values, synthetic control over particle size, shape, functionalization and proven biocompatibility. Our experimental designs were guided by a series of theoretical calculations, which provided clues to the effects of particle size, size distribution, magnetic field, frequency and reaction medium. Materials of theoretically optimal size were synthesized, functionalized, and their effects in the oscillating magnetic field were subsequently investigated. Under our conditions, the materials that clustered e.g. silica-coated and PNIPAM-coated iron oxides exhibited the highest heat generation, while iron oxides embedded in MSNs and mesoporous iron oxides exhibited the least bulk heating. It is worth noting that the specific loss power of PNIPAM-coated Fe 3 O 4 was peculiarly high, and the heat loss mechanism of this material remains to be elucidated. Since thermocatalysis is a long-term goal of this project, we also investigated the effects of the oscillating magnetic field system for the synthesis of 7-hydroxycoumarin-3-carboxylic acid. Application of an oscillating magnetic field in the presence of magnetic particles with high thermal response was found to effectively increase the reaction rate of the uncatalyzed synthesis of the coumarin derivative compared to the room temperature control.

09 BIOMASS FUELS↗

NUMERICAL SIMULATIONS OF IMBALANCED STRONG MAGNETOHYDRODYNAMIC TURBULENCE

Magnetohydrodynamics (MHD) is invoked to address turbulent fluctuations in a variety of astrophysical systems. MHD turbulence in nature is often anisotropic and imbalanced, in that Alfvenic fluctuations moving in opposite directions along the background magnetic field carry unequal energies. This work formulates specific requirements for effective numerical simulations of strong imbalanced MHD turbulence with a guide field B {sub 0}. High-resolution simulations are then performed and they suggest that the spectra of the counterpropagating Alfven modes do not differ from the balanced case, while their amplitudes and the corresponding rates of energy cascades are significantly affected by the imbalance. It is further proposed that the stronger the imbalance the larger the magnetic Reynolds number that is required in numerical simulations in order to correctly reproduce the turbulence spectrum. This may explain current discrepancies among numerical simulations and observations of imbalanced MHD turbulence.

79 ASTRONOMY AND ASTROPHYSICS↗

Guiding center equations for the magnetic dipole

Since the discovery of Van Allen radiation belts in the 1960s, observations of energetic ions trapped in the Earth's dipole magnetic field have illustrated the remarkable confinement properties of this configuration. As such, it has been used for confining a hot plasma for nuclear fusion studies, starting from the pioneering work of Bo Lehnert and Akira Hasegawa, in the Levitated Dipole Experiment (LDX) at MIT until 2011 and in the RT-1 experiment at the University of Tokyo. More recently, the dipole has been subject to a renewed interest for fusion studies by a couple of startups and for smaller applications as a cold plasma source. While the equilibrium and magneto-hydrodynamic stability of the dipole have been investigated quite in detail, neoclassical properties of the dipole are comparatively much less known: the dipole is more known in geophysics than in fusion science. For this reason, in this paper, we propose a set of Hamiltonian, guiding-center equations to describe the motion of electrons and ions in a magnetic dipole configuration. We also developed a code, and we show the main features of particle motion, benchmarking our results with the analytical solutions for the bounce and precession motion, which are well documented in the literature. We also draw some general conclusions for the neoclassical transport in usual toroidal confinement schemes, such as the tokamak and the stellarator, pointing out the unique advantages of the dipole in confining energetic particles.

Hamiltonian mechanics↗

Brightness enhancement method for a high-intensity positron beam produced by an electron accelerator

A method for enhancing the brightness of an intense slow positron beam produced by an electron linear accelerator (LINAC) in order to obtain an intense positron microbeam was developed. The developed brightness enhancement system is simple and consists only of a few beam optics and a transmission remoderator. The slow positron beam produced by the LINAC is magnetically guided from the positron source to an experimental room. The beam is extracted from the magnetic field and is focused by a lens on the remoderator to enhance its brightness. The brightness-enhanced beam is extracted from the remoderator and focused on a sample by a lens. The beam size at the sample was 90 {mu}m, which was two orders of magnitude smaller than that in the magnetic transport system that was about 10 mm. The efficiency of the transmission remoderator was about 5%. Adiabatic rules in the magnetic transport and the paraxial-ray equation were used to estimate the beam size that could be produced using this method.

43 PARTICLE ACCELERATORS↗

Magnetohydrodynamic actuation of droplets for millimetric planar fluidic systems

In this work, a magnetohydrodynamic method is proposed for the actuation of droplets in small-scale planar fluidic systems, providing an alternative to commonly used methods such as electrowetting-on-dielectric. Elementary droplet-based operations, including transport, merging, and mixing, are demonstrated. The forces acting on millimetric droplets are carefully investigated, with a primary focus on the magnetic actuation force and on the unbalanced capillary forces that arise due to hysteresis. A super-hydrophobic channel is 3D printed to guide the droplets, with thin wires installed as contact electrodes and permanent magnets providing a static magnetic field. It is shown that droplet motion is enhanced by increasing the droplet size and minimizing the electrode contact surface. The effects of channel geometry on threshold voltage and minimum moveable droplet volume are characterized. Finally, the presence of electrolysis is investigated and mitigating strategies are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highlights for DOE ASCR Applied Math Office [Slides]

An efficient Picard-based solver is proposed for a novel energy conserving particle integrator preserving all first-order guiding center drifts and correct gyroradius for large time steps in arbitrary (non-uniform) magnetic fields. This research enables the efficient deployment of the novel asymptotic preserving (AP) particle orbit integrator into modern energy-conserving, implicit particle-in-cell codes, delivering a truly multiscale simulation capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗