Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The Importance of Slag Structure to Boron Removal from Silicon during the Refining Process: Insights from Raman and Nuclear Magnetic Resonance Spectroscopy Study

Slag structure plays an important role in determining the relative ease of boron removal from silicon. Correlation between slag structure and boron removal thermodynamics was experimentally studied by Raman and nuclear magnetic resonance (NMR) spectroscopy using CaO-SiO{sub 2}-Na{sub 2}O slags with different optical basicities (0.6 to 0.71). Optimization of slag depolymerization leads to efficient removal of boron. The extent of nonbridged oxygen content (NBO/T) and boron removal gradually increased with an increase in optical basicity from 0.6 to 0.66: B{sub 2}O{sub 3} derived from boron oxidation captured nonbridging oxygens of Q{sup 0}(Si), Q{sup 1}(Si), and Q{sup 2}(Si), and was incorporated into the silicate network in the form of Q{sup 3}(Si and B). When optical basicity increased to 0.71, NBO/T rapidly increased and boron removal decreased considerably. Quick depolymerization of Q{sup 3}(Si and B) deteriorated the stability of boron. Various structural forms of boron in the silicate network were successfully detected: the BO{sub 3} trihedrons {sup [3]}B-3Si, {sup [3]}B-2Si-1NBO, and BO{sub 3} (nonring), and the BO{sub 4} tetrahedrons BO{sub 4} (1B, 3Si) and BO{sub 4} (0B, 4Si). BO{sub 4} (1B, 3Si) was the main structure contributing to the increase of boron capacity; BO{sub 3} (nonring), detected under higher optical basicity conditions, may cause deterioration of boron removal by suppressing its oxidation.

36 MATERIALS SCIENCE↗

Magnetic resonance imaging of the calcaneus: preliminary assessment of trabecular bone-dependent regional variations in marrow relaxation time compared with dual X-ray absorptiometry

RATIONALE AND OBJECTIVES: Marrow transverse relaxation time (T2*) in magnetic resonance (MR) imaging may be related to the density and structure of the surrounding trabecular network. We investigated regional variations of T2* in the human calcaneus and compared the findings with bone mineral density (BMD), as measured by dual X-ray absorpiometry (DXA). Short- and long-term precisions were evaluated first to determine whether MR imaging would be useful for the clinical assessment of disease status and progression in osteoporosis. METHODS: Gradient-recalled echo MR images of the calcaneus were acquired at 1.5 T from six volunteers. Measurements of T2* were compared with BMD and (for one volunteer) conventional radiography. RESULTS: T2* values showed significant regional variation; they typically were shortest in the superior region of the calcaneus. There was a linear correlation between MR and DXA measurements (r = .66 for 1/T2* versus BMD). Differences in T2* attributable to variations in analysis region-of-interest placement were not significant for five of the six volunteers. Sagittal MR images had short- and long-term precision errors of 4.2% and 3.3%, respectively. For DXA, the precision was 1.3% (coefficient of variation). CONCLUSION: MR imaging may be useful for trabecular bone assessment in the calcaneus. However, given the large regional variations in bone density and structure, the choice of an ROI is likely to play a major role in the accuracy, precision, and overall clinical efficacy of T2* measurements.

Non-NASA Center↗

A Comparison of Lumpectomy Cavity Delineations Between Use of Magnetic Resonance Imaging and Computed Tomography Acquired With Patient in Prone Position for Radiation Therapy Planning of Breast Cancer

Purpose: To compare lumpectomy cavity (LC) and planning target volume (PTV) delineated with the use of magnetic resonance imaging (MRI) and computed tomography (CT) and to examine the possibility of replacing CT with MRI for radiation therapy (RT) planning for breast cancer. Methods and Materials: MRI and CT data were acquired for 15 patients with early-stage breast cancer undergoing lumpectomy during RT simulation in prone positions, the same as their RT treatment positions. The LCs were delineated manually on both CT (LC-CT) and MRI acquired with 4 sequences: T1, T2, STIR, and DCE. Various PTVs were created by expanding a 15-mm margin from the corresponding LCs and from the union of the LCs for the 4 MRI sequences (PTV-MRI). Differences were measured in terms of cavity visualization score (CVS) and dice coefficient (DC). Results: The mean CVSs for T1, T2, STIR, DCE, and CT defined LCs were 3.47, 3.47, 3.87, 3.50. and 2.60, respectively, implying that the LC is mostly visible with a STIR sequence. The mean reductions of LCs from those for CT were 22%, 43%, 36%, and 17% for T1, T2, STIR, and DCE, respectively. In 14 of 15 cases, MRI (union of T1, T2, STIR, and DCE) defined LC included extra regions that would not be visible from CT. The DCs between CT and MRI (union of T1, T2, STIR, and DCE) defined volumes were 0.65 ± 0.20 for LCs and 0.85 ± 0.06 for PTVs. There was no obvious difference between the volumes of PTV-MRI and PTV-CT, and the average PTV-STIR/PTV-CT volume ratio was 0.83 ± 0.23. Conclusions: The use of MRI improves the visibility of LC in comparison with CT. The volumes of LC and PTV generated based on a MRI sequence are substantially smaller than those based on CT, and the PTV-MRI volumes, defined by the union of T1, T2, STIR, and DCE, were comparable with those of PTV-CT for most of the cases studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-Body Magnetic Resonance Angiography with Additional Steady-State Acquisition of the Infragenicular Arteries in Patients with Peripheral Arterial Disease

The purpose of this investigation was to determine if addition of infragenicular steady-state (SS) magnetic resonance angiography (MRA) to first-pass imaging improves diagnostic performance compared with first-pass imaging alone in patients with peripheral arterial disease (PAD) undergoing whole-body (WB) MRA. Twenty consecutive patients with PAD referred to digital-subtraction angiography (DSA) underwent WB-MRA. Using a bolus-chase technique, first-pass WB-MRA was performed from the supra-aortic vessels to the ankles. The blood-pool contrast agent gadofosveset trisodium was used at a dose of 0.03 mmol/kg body weight. Ten minutes after injection of the contrast agent, high-resolution (0.7-mm isotropic voxels) SS-MRA of the infragenicular arteries was performed. Using DSA as the 'gold standard,' sensitivities and specificities for detecting significant arterial stenoses ({>=}50% luminal narrowing) with first-pass WB-MRA, SS-MRA, and combined first-pass and SS-MRA were calculated. Kappa statistics were used to determine intermodality agreement between MRA and DSA. Overall sensitivity and specificity for detecting significant arterial stenoses with first-pass WB-MRA was 0.70 (95% confidence interval 0.61 to 0.78) and 0.97 (0.94 to 0.99), respectively. In first-pass WB-MRA, the lowest sensitivity was in the infragenicular region, with a value of 0.42 (0.23 to 0.63). Combined analysis of first-pass WB-MRA and SS-MRA increased sensitivity to 0.81 (0.60 to 0.93) in the infragenicular region, with specificity of 0.94 (0.88 to 0.97). Sensitivity and specificity for detecting significant arterial stenoses with isolated infragenicular SS-MRA was 0.47 (0.27 to 0.69) and 0.86 (0.78 to 0.91), respectively. Intermodality agreement between MRA and DSA in the infragenicular region was moderate for first-pass WB-MRA ({kappa} = 0.49), fair for SS-MRA ({kappa} = 0.31), and good for combined first-pass/SS-MRA ({kappa} = 0.71). Addition of infragenicular SS-MRA to first-pass WB MRA improves diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Observation of Ion Exchange in Mechanically Activated LiH+MgB2 System Using Ultra-High Field Nuclear Magnetic Resonance Spectroscopy

The LiBH4 + MgH2 system has great potential for hydrogen vehicle applications. In this study, the reported solid-state hydrogenation system made of LiH + 1/2MgB2 has been investigated using ultra-high field nuclear magnetic resonance spectroscopy. It is found that Mg-Li ion exchange occurs within MgB2 during ball milling to form a compound of (Mg1-xLi2x)B2 which facilitates the formation of LiBH4 in the subsequent hydriding reaction. This discovery offers a scientific foundation for investigating the detailed mechanisms of solid-state hydrogenation and dehdrogenation of the LiBH4 +MgH2 system in the future.

08 HYDROGEN↗

The role of edge resonant magnetic perturbations in edge-localized-mode suppression and density pump-out in low-collisionality DIII-D plasmas

Two-fluid nonlinear MHD simulations using the TM1 code demonstrate that the formation of magnetic islands at the top and bottom of the H-mode pedestal, together with the strong screening of resonant fields in the gradient region of the pedestal, can account for ELM suppression and density pump-out by n = 2 resonant magnetic perturbations (RMPs) in low-collisionality DIII-D ITER similar shape (ISS) plasmas. Using experimentally relevant transport coefficients, neoclassical resistivity, electron collisionality, and RMP amplitudes, nonlinear MHD simulations reproduce the observed level of density reduction (density pump-out) in DIII-D due to the formation of narrow magnetic islands in the resistive foot of pedestal. For large amplitude RMPs ( B r / B t > 1 × 10 -4 ) simulations predict resonant field penetration and resulting in pressure reduction at the top of the pedestal, consistent with experimental observations at the onset of ELM suppression. The predicted reduction in the height and width of the pedestal by magnetic island enhanced collisional transport provides a quantitative mechanism for the stabilization of the peeling-ballooning mode (PBM). Importantly, these simulations predict strong screening of resonant fields in the steep gradient region of the pedestal due to strong E × B rotation and diamagnetic flows. Yet, if the plasma resistivity is made artificially larger (~ 10X) than neoclassical, the simulations predict magnetic stochasticity throughout the plasma edge and the collapse of the pedestal due to the reduction in the penetration threshold with increasing resistivity. A scaling relation for resonant field penetration at the pedestal top, using several hundred nonlinear simulations, reproduces the density and E × B rotation dependence of the ELM suppression threshold observed in DIII-D. Simulations using ITER model equilibria indicate that the penetration threshold at the top of the ITER pedestal will be lower than in DIII-D due to the anticipated lower perpendicular flow velocities in ITER, resulting in the weaker screening of resonant fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

{sup 1}H nuclear magnetic resonance study of hydrated water dynamics in perfluorosulfonic acid ionomer Nafion

We have studied the dynamics of hydrated water molecules in the proton exchange membrane of Nafion by means of high-resolution {sup 1}H nuclear magnetic resonance (NMR) measurements. “Bound” and “free” states of hydrated water clusters as well as the exchange protons were identified from the NMR chemical shift measurements, and their activation energies were obtained from the temperature-dependent laboratory- and rotating-frame spin-lattice relaxation measurements. Besides, a peculiar motional transition in the ultralow frequency region was observed at 373 K for the “free” hydrated water from the rotating-frame NMR spin-lattice relaxation time measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four dimensional magnetic resonance imaging with retrospective k-space reordering: A feasibility study

Purpose: Current four dimensional magnetic resonance imaging (4D-MRI) techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of a new strategy for 4D-MRI which is based on retrospective k-space reordering. Methods: We simulated a k-space reordered 4D-MRI on a 4D digital extended cardiac-torso (XCAT) human phantom. A 2D echo planar imaging MRI sequence [frame rate (F) = 0.448 Hz; image resolution (R) = 256 × 256; number of k-space segments (N{sub KS}) = 4] with sequential image acquisition mode was assumed for the simulation. Image quality of the simulated “4D-MRI” acquired from the XCAT phantom was qualitatively evaluated, and tumor motion trajectories were compared to input signals. In particular, mean absolute amplitude differences (D) and cross correlation coefficients (CC) were calculated. Furthermore, to evaluate the data sufficient condition for the new 4D-MRI technique, a comprehensive simulation study was performed using 30 cancer patients’ respiratory profiles to study the relationships between data completeness (C{sub p}) and a number of impacting factors: the number of repeated scans (N{sub R}), number of slices (N{sub S}), number of respiratory phase bins (N{sub P}), N{sub KS}, F, R, and initial respiratory phase at image acquisition (P{sub 0}). As a proof-of-concept, we implemented the proposed k-space reordering 4D-MRI technique on a T2-weighted fast spin echo MR sequence and tested it on a healthy volunteer. Results: The simulated 4D-MRI acquired from the XCAT phantom matched closely to the original XCAT images. Tumor motion trajectories measured from the simulated 4D-MRI matched well with input signals (D = 0.83 and 0.83 mm, and CC = 0.998 and 0.992 in superior–inferior and anterior–posterior directions, respectively). The relationship between C{sub p} and N{sub R} was found best represented by an exponential function (C{sub P}=100(1−e{sup −0.18N{sub R}}), when N{sub S} = 30, N{sub P} = 6). At a C{sub P} value of 95%, the relative error in tumor volume was 0.66%, indicating that N{sub R} at a C{sub P} value of 95% (N{sub R,95%}) is sufficient. It was found that N{sub R,95%} is approximately linearly proportional to N{sub P} (r = 0.99), and nearly independent of all other factors. The 4D-MRI images of the healthy volunteer clearly demonstrated respiratory motion in the diaphragm region with minimal motion induced noise or aliasing. Conclusions: It is feasible to generate respiratory correlated 4D-MRI by retrospectively reordering k-space based on respiratory phase. This new technology may lead to the next generation 4D-MRI with high spatiotemporal resolution and optimal tumor contrast, holding great promises to improve the motion management in radiotherapy of mobile cancers.

60 APPLIED LIFE SCIENCES↗

An improved nuclear magnetic resonance spectrometer

Cylindrical sample container provides a high degree of nuclear stabilization to a nuclear magnetic resonance /nmr/ spectrometer. It is placed coaxially about the nmr insert and contains reference sample that gives a signal suitable for locking the field and frequency of an nmr spectrometer with a simple audio modulation system.

Elleman, D. D.↗

A versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy.

A digital pulse programmer producing the standard pulse sequences required for pulsed nuclear magnetic resonance spectroscopy is described. In addition, a 'saturation burst' sequence, useful in the measurement of long relaxation times in solids, is provided. Both positive and negative 4 V trigger pulses are produced that are fully synchronous with a crystal-controlled time base, and the pulse programmer may be phase-locked with a maximum pulse jitter of 3 ns to the oscillator of a coherent pulse spectrometer. Medium speed TTL integrated circuits are used throughout.

Tarr, C. E.↗

Analysis of the transient response of nuclear spins in GaAs with/without nuclear magnetic resonance

As an alternative to studying the steady-state responses of nuclear spins in solid state systems, working within a transient-state framework can reveal interesting phenomena. The response of nuclear spins in GaAs to a changing magnetic field was analyzed based on the time evolution of nuclear spin temperature. Simulation results well reproduced our experimental results for the transient oblique Hanle signals observed in an all-electrical spin injection device. The analysis showed that the so called dynamic nuclear polarization can be treated as a cooling tool for the nuclear spins: It works as a provider to exchange spin angular momentum between polarized electron spins and nuclear spins through the hyperfine interaction, leading to an increase in the nuclear polarization. In addition, a time-delay of the nuclear spin temperature with a fast sweep of the external magnetic field produces a possible transient state for the nuclear spin polarization. On the other hand, the nuclear magnetic resonance acts as a heating tool for a nuclear spin system. This causes the nuclear spin temperature to jump to infinity: i.e., the average nuclear spins along with the nuclear field vanish at resonant fields of {sup 75}As, {sup 69}Ga and {sup 71}Ga, showing an interesting step-dip structure in the oblique Hanle signals. These analyses provide a quantitative understanding of nuclear spin dynamics in semiconductors for application in future computation processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural characterization of ion-vapor deposited hydrogenated amorphous carbon coatings by solid state {sup 13}C nuclear magnetic resonance

In the present study, unique structural heterogeneity was observed in ion-vapor deposited a-C:H coatings by performing {sup 13}C MAS and {sup 1}H-{sup 13}C CPMAS experiments on solid state nuclear magnetic resonance devices. Two distinct types of sp{sup 2} C clusters were discovered: one of them denoted as sp{sup 2} C′ in content of 3–12 at. % was non-protonated specifically localized in hydrogen-absent regions, while the other dominant one denoted as sp{sup 2} C″ was hydrogenated or at least proximate to proton spins. On basis of the notably analogous variation of sp{sup 2} C′ content and Raman parameters as function of substrate bias voltage in the whole range of 0.5 kV–3.5 kV, a model of nano-clustering configuration was proposed that the sp{sup 2} C′ clusters were embedded between sp{sup 2} C″ clusters and amorphous sp{sup 3} C matrix as trapped interfaces or boundaries where the sp{sup 2} carbon bonds were highly distorted. Continuous increase of bias voltage would promote the nano-clustering and re-ordering of dominant sp{sup 2} C″ clusters, thus results in a marked decrease of interspace and a change of the content of sp{sup 2} C′ clusters. Further investigation on the {sup 13}C magnetization recovery showed typical stretched-exponential approximation due to the prominent presence of paramagnetic centers, and the stretched power α varied within 0.6–0.9 from distinct types of sp{sup 2} C clusters. Differently, the magnetization recovery of {sup 1}H showed better bi-exponential approximation with long and short T{sub 1}(H) fluctuated within 40–60 ms and 0.1–0.3 ms approximately in content of 80% ± 5% and 20% ± 5%, respectively, varying with various bias voltages. Meanwhile, the interrupted {sup 13}C saturation recovery with an interval of short T{sub 1}(H) showed that most of quick-relaxing protons were localized in sp{sup 2} C″ clusters. Such a short T{sub 1}(H) was only possibly resulted from a relaxation mechanism associated with electron-nuclear dipolar interaction or spinning diffusion, and its partial distribution in sp{sup 2} C″ clusters may imply more complex configurations of unpaired electrons in studied a-C:H coatings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Review of cardiovascular imaging in the Journal of Nuclear Cardiology 2018. Part 1 of 2: Positron emission tomography, computed tomography, and magnetic resonance

In this review, we summarize key articles that have been published in the Journal of Nuclear Cardiology in 2018 pertaining to nuclear cardiology with advanced multi-modality and hybrid imaging including positron emission tomography, cardiac-computed tomography, and magnetic resonance. In an upcoming review, we will summarize key articles that relate to the progress made in the field of single-photon emission computed tomography. We hope that these sister reviews will be useful to the reader to navigate the literature in our field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 1}H and {sup 31}P nuclear magnetic resonance study of proton-irradiated KH{sub 2}PO{sub 4}

We have studied the microscopic structure and dynamics in a proton-irradiated KH{sub 2}PO{sub 4} single crystal. Our {sup 1}H and {sup 31}P nuclear magnetic resonance measurements indicate that proton irradiation gives rise to a decrease in the local dipolar order of the rigid lattice protons and an increase in interstitial protons as well as structural distortion of the PO{sub 4} tetrahedra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Field-Deployable Magnetic Resonance Imaging Rhizotron for Modeling and Enhancing Root Growth and Biogeochemical Function

A collaborative team from Texas A&M AgriLife Research, ABQMR Inc., the Soil Health Institute, the Athinoula A. Martinos Center for Biomedical Imaging, and NIST developed low-field magnetic resonance imaging (LF-MRI) instrumentation capable of imaging intact soil-root systems. The system measured root biomass, architecture, 3D mass distribution, and growth rates, providing a non-destructive means to evaluate ideal plant characteristics based on root metrics. It also successfully generated three-dimensional images of soil water content, a key property influencing root growth and exploration. Operating much like an MRI used in a medical setting, the system functioned in field conditions without damaging plants, overcoming the limitations of traditional methods such as trenching, soil coring, and root excavation. Over the course of the project, the team designed and built three functional prototype systems. These prototypes provided new insights into root–water–soil interactions that drive processes such as nutrient uptake, water use, and carbon management. This information contributed to efforts to optimize plants for carbon sequestration without sacrificing economic yield. The project also supported the identification of desirable traits for energy sorghum, including high root growth rates, more vertical root angles, and enhanced drought resilience under water-limiting conditions.

09 BIOMASS FUELS↗

Single-spin microscope with sub-nanoscale resolution based on optically detected magnetic resonance

Invention of scanning tunneling microscope (STM) and atomic force microscope (AFM) initiated a new era of material science and technology characterized by 2-D imaging with atomic resolution and manipulation of individual atoms. However, for further progress in material science, and in particular in structural biology, 3-D imaging with sub-nanometer resolution is very desirable. Currently the most promising technique for 3-D imaging is magnetic resonance force microscopy (MRFM), which senses individual electron spins [1,2] with nanoscale resolution and can detect collective magnetization of about 100 nuclear spins [3]. The highest sensitivity demonstrated by MRFM is based on a time modulation technique called the oscillating cantilever-driven adiabatic reversals (OSCAAR) which requires a long phase relaxation time T 2 of measured spins, which usually corresponds to rather low temperature. For example, a temperature of 300 mK was used in the case of 3D imaging of the tobacco mosaic virus [3]. This limitation is incompatible with the room-temperature operation needed for the study of biological systems under physiological conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗