Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS REDUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Megawatt solar power systems for lunar surface operations

Lunar surface operations require habitation, transportation, life support, scientific, and manufacturing systems, all of which require some form of power. As an alternative to nuclear power, the development of a modular one megawatt solar power system is studied, examining both photovoltaic and dynamic cycle conversion methods, along with energy storage, heat rejection, and power backup subsystems. For photovoltaic power conversion, two systems are examined. First, a substantial increase in photovoltaic conversion efficiency is realized with the use of new GaAs/GaSb tandem photovoltaic cells, offering an impressive overall array efficiency of 23.5 percent. Since these new cells are still in the experimental phase of development, a currently available GaAs cell providing 18 percent efficiency is examined as an alternate to the experimental cells. Both Brayton and Stirling cycles, powered by linear parabolic solar concentrators, are examined for dynamic cycle power conversion. The Brayton cycle is studied in depth since it is already well developed and can provide high power levels fairly efficiently in a compact, low mass system. The dynamic conversion system requires large scale waste heat rejection capability. To provide this heat rejection, a comparison is made between a heat pipe/radiative fin system using advanced composites, and a potentially less massive liquid droplet radiator system. To supply power through the lunar night, both a low temperature alkaline fuel cell system and an experimental high temperature monolithic solid-oxide fuel cell system are considered. The reactants for the fuel cells are stored cryogenically in order to avoid the high tankage mass required by conventional gaseous storage. In addition, it is proposed that the propellant tanks from a spent, prototype lunar excursion vehicle be used for this purpose, therefore resulting in a significant overall reduction in effective storage system mass.

Adams, Brian↗

Model reduction in the physical coordinate system

In the dynamics modeling of a flexible structure, finite element analysis employs reduction techniques, such as Guyan's reduction, to remove some of the insignificant physical coordinates, thus producing a dynamics model that has smaller mass and stiffness matrices. But this reduction is limited in the sense that it removes certain degrees of freedom at a node points themselves in the model. From the standpoint of linear control design, the resultant model is still too large despite the reduction. Thus, some form of the model reduction is frequently used in control design by approximating a large dynamical system with a fewer number of state variables. However, a problem arises from the placement of sensors and actuators in the reduced model, because a model usually undergoes, before being reduced, some form of coordinate transformations that do not preserve the physical meanings of the states. To correct such a problem, a method is developed that expresses a reduced model in terms of a subset of the original states. The proposed method starts with a dynamic model that is originated and reduced in finite element analysis. Then the model is converted to the state space form, and reduced again by the internal balancing method. At this point, being in the balanced coordinate system, the states in the reduced model have no apparent resemblance to those of the original model. Through another coordinate transformation that is developed, however, this reduced model is expressed by a subset of the original states.

Yae, K. Harold↗

The influence of space flight on erythrokinetics in man. Space Life Sciences Missions 1 and 2. Experiment E261

The purpose of this contract was to design and conduct experiments that would increase our understanding of the influence of space flight on erythrokinetics and the rapid change that occurs in the red blood cell mass during spaceflight. The experiment designated E261, was flown on Space Life Science missions SLS-1 and SLS-2 (STS 40 and STS 58). Unique features of this experiment included radionuclide tracer studies during flight and frequent in-flight blood samples specifically for the first three or four days of the mission. Plasma volume measurements were made early and late in the missions. Radioactive iron kinetics studies were initiated after one or three days in microgravity since the magnitude of the red blood cell mass decrease dictated that bone marrow production must be decreased very early in the flight. The schedule was designed to study the time course of the changes that occur during spaceflight and to possibly define a mechanism for the rapid reduction in red blood cell mass.

Alfrey, Clarence P.↗

Three dimensional numerical investigation of gravitational and solutal effects in a cylindrical cell

Three-dimensional numerical computations of natural convection in a cylindrical ampoule (L/R = 4) are presented for a Ga-doped Ge melt. The ampoule is maintained at isothermal end conditions, and the g vector is oriented at an angle gamma with the cylinder axis. Detailed velocity, temperature, and concentration field distributions are presented for different gravity levels and a range of inclination angles (gamma between 0 and 180 deg). For terrestrial conditions, complex, multicellular flow is found to occur for gamma between 0 and 180 deg. The strong convection results in significant isotherm distortions and enhanced heat transfer. As the gravity level is reduced to 0.001 g(0), the overall convection strength decays but the 3D multicellular flow persists, causing appreciable mass transfer. For a further reduction in the gravity level to 0.00001 g(0), the system thermo/solutal characteristics are close to a purely diffusive behavior. Flow and thermal and solutal distributions are presented in the principal, orthogonal, and cross sectional planes, and the average system heat and mass transfer are calculated.

Ramachandran, N.↗

NASA'S Standard Measures During Bed Rest: Adaptations in the Cardiovascular System

Bed rest is a well-accepted analog of space flight that has been used extensively to investigate physiological adaptations in a larger number of subjects in a shorter amount of time than can be studied with space flight and without the confounding effects associated with normal mission operations. However, comparison across studies of different bed rest durations, between sexes, and between various countermeasure protocols have been hampered by dissimilarities in bed rest conditions, measurement protocols, and testing schedules. To address these concerns, NASA instituted standard bed rest conditions and standard measures for all physiological disciplines participating in studies conducted at the Flight Analogs Research Unit (FARU) at the University of Texas-Medical Branch. Investigators for individual studies employed their own targeted study protocols to address specific hypothesis-driven questions, but standard measures tests were conducted within these studies on a non-interference basis to maximize data availability while reducing the need to implement multiple bed rest studies to understand the effects of a specific countermeasure. When possible, bed rest standard measures protocols were similar to tests nominally used for medically-required measures or research protocols conducted before and after Space Shuttle and International Space Station missions. Specifically, bed rest standard measures for the cardiovascular system implemented before, during, and after bed rest at the FARU included plasma volume (carbon monoxide rebreathing), cardiac mass and function (2D, 3D and Doppler echocardiography), and orthostatic tolerance testing (15- or 30-minutes of 80 degree head-up tilt). Results to-date indicate that when countermeasures are not employed, plasma volume decreases and the incidence of presyncope during head-up tilt is more frequent even after short-duration bed rest while reductions in cardiac function and mass are progressive as bed rest duration increases. Additionally, while plasma volume loss can be corrected and cardiac mass can be prevented with properly applied countermeasures, orthostatic tolerance is more difficult to protect when supine exercise is the only countermeasure. Similar results have been observed after space flight. Plasma volume, cardiac chamber volume, and orthostatic tolerance recover relatively quickly with resumption of ambulation and normal activity levels after bed rest but restoration of cardiac mass is prolonged.

Lee, Stuart M. C.↗

Development of an Additively Manufactured Turbine Blade Tuned Mass Absorber

An innovative concept using a tuned mass absorber for resonant response reduction of turbine blades that is integrally fabricated into the blades using additive manufactured has been developed. Avoiding high resonant response and resulting high cycle fatigue failure is a major concern of the $100B worldwide turbine industry, which encompasses power generation, jet engines and rocket engine turbomachinery. Blade failure is potentially catastrophic, and although preventative measures using dampers do exist, these solutions are extremely expensive to develop and are not always effective. In addition, many of the existing techniques do not work for newer integrally bladed disks (or blisks), where there is no inherent damping in the assembly. The proposed concept, in which a tuned mass absorber re-arranges the structural dynamics and moves energy from the blade to the absorber, is designed specifically for blisks, and is intentionally linear, enabling accurate response prediction during design. Single blade prototypes have been analyzed, fabricated, and tested, and different absorber concepts have shown a reduction in response of up to 60%. After an extensive commercialization and prior art search, MSFC determined the innovation merited the generation and submission of a patent application in August ’21. Funding is now being sought to fabricate a 20-bladed blisk which would be spun at operational speeds with substantially higher and more realistic pressure loads in a special spin facility. Successful completion of this program would raise the TRL from 3/4 to 6/7, significantly improving the viability for adoption of the concept not only in rocket engines but other industrial applications as well.

Turbine Blades↗

Impact of thermal energy storage properties on solar dynamic space power conversion system mass

A 16 parameter solar concentrator/heat receiver mass model is used in conjunction with Stirling and Brayton Power Conversion System (PCS) performance and mass computer codes to determine the effect of thermal energy storage (TES) material property changes on overall PCS mass as a function of steady state electrical power output. Included in the PCS mass model are component masses as a function of thermal power for: concentrator, heat receiver, heat exchangers (source unless integral with heat receiver, heat sink, regenerator), heat engine units with optional parallel redundancy, power conditioning and control (PC and C), PC and C radiator, main radiator, and structure. Critical TES properties are: melting temperature, heat of fusion, density of the liquid phase, and the ratio of solid-to-liquid density. Preliminary results indicate that even though overalll system efficiency increases with TES melting temperature up to 1400 K for concentrator surface accuracies of 1 mrad or better, reductions in the overall system mass beyond that achievable with lithium fluoride (LiF) can be accomplished only if the heat of fusion is at least 800 kJ/kg and the liquid density is comparable to that of LiF (1880 kg/cu m.

Juhasz, Albert J.↗

Impact of thermal energy storage properties on solar dynamic space power conversion system mass

A 16 parameter solar concentrator/heat receiver mass model is used in conjunction with Stirling and Brayton Power Conversion System (PCS) performance and mass computer codes to determine the effect of thermal energy storage (TES) material property changes on overall PCS mass as a function of steady state electrical power output. Included in the PCS mass model are component masses as a function of thermal power for: concentrator, heat receiver, heat exchangers (source unless integral with heat receiver, heat sink, regenerator), heat engine units with optional parallel redundancy, power conditioning and control (PC and C), PC and C radiator, main radiator, and structure. Critical TES properties are: melting temperature, heat of fusion, density of the liquid phase, and the ratio of solid-to-liquid density. Preliminary results indicate that even though overall system efficiency increases with TES melting temperature up to 1400 K for concentrator surface accuracies of 1 mrad or better, reductions in the overall system mass beyond that achievable with lithium fluoride (LiF) can be accomplished only if the heat of fusion is at least 800 kJ/kg and the liquid density is comparable to that of LiF (1800 kg/cu m).

Juhasz, Albert J.↗

Lightweight Ablative and Ceramic Thermal Protection System Materials for NASA Exploration Systems Vehicles

As a collaborative effort among NASA Centers, the "Lightweight Nonmetallic Thermal Protection Materials Technology" Project was set up to assist mission/vehicle design trade studies, to support risk reduction in thermal protection system (TPS) material selections, to facilitate vehicle mass optimization, and to aid development of human-rated TPS qualification and certification plans. Missions performing aerocapture, aerobraking, or direct aeroentry rely on advanced heatshields that allow reductions in spacecraft mass by minimizing propellant requirements. Information will be presented on candidate materials for such reentry approaches and on screening tests conducted (material property and space environmental effects tests) to evaluate viable candidates. Seventeen materials, in three classes (ablatives, tiles, and ceramic matrix composites), were studied. In additional to physical, mechanical, and thermal property tests, high heat flux laser tests and simulated-reentry oxidation tests were performed. Space environmental effects testing, which included exposures to electrons, atomic oxygen, and hypervelocity impacts, was also conducted.

Valentine, Peter G.↗

Carbothermal Reduction Demonstration (CaRD)

Introduction: Lunar regolith is approximately 45% oxygen by mass. The majority of the oxygen is bound in silicate minerals. The carbothermal reduction process has been proven to be effective at removing oxygen from lunar regolith simulants. The Carbothermal Reduction Demonstration (CaRD) project aims to increase the Technology Readiness Level (TRL) of a combined solar concentrator and carbothermal reduction systemin order to demonstrate this technology on the lunar surface. The CaRD project is divided into two design cycles, a brass board and prototype. The status of both design cycles will be discussed, as well as concepts for how this technology can be applied to the Artemis program in the future. Brassboard Vacuum Test: For the brassboard demonstration, a 2 kW Nd-YAG laser was used to heat lunar regolith simulant within a carbothermal reactor developed by Sierra Space. The reactor was placed inside of a 15 ft thermal vacuum chamber at the Johnson Space Center. The resulting reaction products were analyzed using both a gas chromotograph and mass spectrometer provided by Kennedy Space Center. Thermal data was also collected. Prototype Design: For the prototype, the CaRD team will perform another thermal vacuum test at JSC using the same interfaces and assets developed for the brassboard but will test a new carbothermal reactor design that Sierra Space is developing through the Carbothermal Oxygen Production Reactor (COPR) Tipping Point project that will include a means to autonomously move regolith in and out of the reactor. In addition, a deployable solar concentrator is being developed by Glenn Research Center using mirrors produced by Carbon Mirror Applications. The solar concentrator will be used to deliver solar energy into a carbothermal reactor to melt regolith and extract oxygen. Avionics and software for the concentrator are being developed by Kennedy Space Center. Future Concepts: An ongoing task within the CaRD project is to update models that can be used to determine the mass, power, and size of In-Situ Resource Utilization concepts at various scales. These models can now be used to analyze alternatives for future applications based on the latest available data.

Aaron Paz↗

Metabolic responses to head-down suspension in hypophysectomized rats

Rats exposed to head-down suspension (HDS) exhibit reductions in maximal O2 consumption (VO2max) and atrophy of select hindlimb muscles. This study tested the hypothesis that an endocrine-deficient rat exposed to HDS would not exhibit reductions in VO2max or hindlimb muscle mass. Hypophysectomized (HYPX) and sham-operated (SHAM) rats were tested for VO2max before and after 28 days of HDS or cage control (CC) conditions. No significant reductions in VO2max were observed in HYPX rats. In contrast, SHAM-HDS rats exhibited a significant reduction in absolute (-16%) and relative (-29%) measures of aerobic capacity. Time course experiments revealed a reduction in VO2max in SHAM-HDS rats within 7 days, suggesting that cardiovascular adjustments to HDS occurred in the 1st wk. HDS was associated with atrophy of the soleus (-42%) in SHAM rats, whereas HYPX rats exhibited atrophy of the soleus (-36%) and plantaris (-13%). SHAM-HDS rats had significantly lower (-38%) soleus citrate synthase activities per gram muscle mass than SHAM-CC, but no significant differences existed between HYPX-HDS and -CC rats. HDS rats had an impaired ability to thermoregulate, as indicated by significantly greater temperature increases per unit run time, compared with their CC counterparts. Pretreatment plasma epinephrine levels were significantly lower in HYPX than in SHAM rats. Norepinephrine concentration was similar for all groups except HYPX-HDS, in which it was significantly higher. HDS had no significant effect on thyroxine or triiodothyronine. SHAM-HDS rats had significantly lower concentrations of testosterone and growth hormone.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Number 14-10↗

Space Exploration Applications for Development of High Capacity Cryocoolers

Long term storage of cryogens is necessary to enable NASAs long duration crewed missions to both the lunar and Martian surfaces. Such missions require in-space transport systems such as Nuclear Thermal Propulsion (NTP), and descent/ascent vehicles for transportation to and from the lunar and Martian surfaces. NTP systems and Lunar/Martian landers utilize cryogenic fluids to minimize architectural volume and mass. To further enhance the capability of these cryogenic systems, the Agency is putting emphasis on reusability, which requires the NTP and ascent/descent elements be replenished on-orbit via tankers or propellant depots, or on the lunar or Martian surface using liquefied in-situ produced propellants. NTP is one of the leading propulsion option for human Mars missions and requires liquid hydrogen to be stored on-orbit for over four years. For such a long duration mission, near “Zero Boil-Off” (ZBO) must be achieved which requires an optimized suite of passive Cryogenic Fluid Management technologies and active cooling (cryocoolers). Tens of Watts of 20K cooling is required to achieve ZBO conditions for NTP, however two-stage cooling using both 20K and 90K systems can lead to a significant reduction in both active cooling mass and power. The use of in-situ resources for lunar and Martian missions will require 150 Watts of 90K cooling for oxygen liquefaction and 300 Watts of 20K cooling for hydrogen liquefaction (lunar only). Descent/Ascent vehicles, propellant depots, and tankers will also require the use of cryocoolers to achieve ZBO conditions. To support these programs, NASA is developing high capacity 20K and 90K reverse turbo-Brayton cycle cryocoolers which offer a scalable, high efficiency, low vibration solution.

cryocooler↗

Jet Noise Reduction by Microjets - A Parametric Study

The effect of injecting tiny secondary jets (microjets ) on the radiated noise from a subsonic primary jet is studied experimentally. The microjets are injected on to the primary jet near the nozzle exit with variable port geometry, working fluid and driving pressure. A clear noise reduction is observed that improves with increasing jet pressure. It is found that smaller diameter ports with higher driving pressure, but involving less thrust and mass fraction, can produce better noise reduction. A collection of data from the present as well as past experiments is examined in an attempt to correlate the noise reduction with the operating parameters. The results indicate that turbulent mixing noise reduction, as monitored by OASPL at a shallow angle, correlates with the ratio of jet to primary jet driving pressures normalized by the ratio of corresponding diameters (p d /pjD). With gaseous injection, the spectral amplitudes decrease at lower frequencies while an increase is noted at higher frequencies. It is apparent that this amplitude crossover is at least partly due to shock-associated noise from the underexpanded jets themselves. Such crossover is not seen with water injection since the flow in that case is incompressible and there is no shock-associated noise. Centerline velocity data show that larger noise reduction is accompanied by faster jet decay as well as significant reduction in turbulence intensities. While a physical understanding of the dependence of noise reduction on p d /pjD remains unclear, given this correlation, an analysis explains the observed dependence of the effect on various other parameters.

Zaman, K. B. M. Q.↗

Modular, thermal bus-to-radiator integral heat exchanger design for Space Station Freedom

The baseline concept is introduced for the 'integral heat exchanger' (IHX) which is the interface of the two-phase thermal bus with the heat-rejecting radiator panels. A direct bus-to-radiator heat-pipe integral connection replaces the present interface hardware to reduce the weight and complexity of the heat-exchange mechanism. The IHX is presented in detail and compared to the baseline system assuming certain values for heat rejection, mass per unit width, condenser capacity, contact conductance, and assembly mass. The spreadsheet comparison can be used to examine a variety of parameters such as radiator length and configuration. The IHX is shown to permit the reduction of panel size and system mass in response to better conductance and packaging efficiency. The IHX is found to be a suitable heat-rejection system for the Space Station Freedom because it uses present technology and eliminates the interface mechanisms.

Chambliss, Joe↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Prediction of Turbulent Jet Mixing Noise Reduction by Water Injection

A one-dimensional control volume formulation is developed for the determination of jet mixing noise reduction due to water injection. The analysis starts from the conservation of mass, momentum and energy for the confrol volume, and introduces the concept of effective jet parameters (jet temperature, jet velocity and jet Mach number). It is shown that the water to jet mass flow rate ratio is an important parameter characterizing the jet noise reduction on account of gas-to-droplet momentum and heat transfer. Two independent dimensionless invariant groups are postulated, and provide the necessary relations for the droplet size and droplet Reynolds number. Results are presented illustrating the effect of mass flow rate ratio on the jet mixing noise reduction for a range of jet Mach number and jet Reynolds number. Predictions from the model show satisfactory comparison with available test data on perfectly expanded hot supersonic jets. The results suggest that significant noise reductions can be achieved at increased flow rate ratios.

Kandula, Max↗