Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Changes in boron fiber strength due to surface removal by chemical etching

The effects of chemical etching on the tensile strength of commercial boron/tungsten fibers were investigated. Fibers with as-received diameters of 203, 143, and 100 micrometers were etched to diameters as small as 43 micrometers. The etching generally resulted in increasing fiber tensile strength with decreasing fiber diameter. And for the 203 micrometer fibers there was an accompanying significant decrease in the coefficient of variation of the tensile strength for diameters down to 89 micrometers. Heat treating these fibers above 1,173 K in a vacuum caused a marked decrease in the average tensile strength of at least 80 percent. But after the fibers were etched, their strengths exceeded the as-received strengths. The tensile strength behavior is explained in terms of etching effects on surface flaws and the residual stress pattern of the as-received fibers.

Smith, R. J.↗

Radioactivities in returned lunar materials

Results from a carbon-14 study in size fractions of lunar soil are reported. The 10 to 30 micrometers and 74 to 124 micrometers size fraction results were supplemented by 30 to 37 micrometers results that are given in this report. The gases from the less than 10 micrometers fraction were extracted and purified and carbon-14 counting is now in progress. Meteorites were also studied using carbon-14, with emphasis directed to those recently discovered in the Antarctic.

Fireman, E. L.↗

Spectrophotometry of OH 26.5+0.6 from 2 to 40 microns

Airborne and ground-based observations show that OH 26.5+0.6 has strong 10 micrometers and weak 18 micrometers silicate absorptions superposed on an overall energy distribution much like a blackbody. The flux level, color temperature, and depth of the 10 micrometers absorption have varied during two years of observations. A model of the source as a late-type variable star that has ejected an optically thick dust shell is suggested; the mass-loss rate implied is greater than about 0.00001 solar masses per year. The fact that significant flux from the source is observed between 4 and 7 micrometers is evidence that oxygen-rich dust has significant opacity in that wavelength range.

Forrest, W. J.↗

Optimum thermal infrared bands for mapping general rock type and temperature from space

A study was carried out to determine quantitatively the number and locations of spectral bands required to perform general rock-type discrimination from spaceborne imaging sensors using only thermal infrared measurements. Beginning with laboratory spectra collected under idealized conditions from relatively well characterized, homogeneous samples, a radiative transfer model was employed to transform ground exitance values into the corresponding spectral radiance at the top of the atmosphere. Taking sensor noise into account analysis of these data revealed that three 1 micrometer wide spectral bands would permit independent estimators of rock-type and sample temperature from a satellite infrared multispectral scanner. This study, indicates that the location of three spectral bands at 8.1-9.1 micrometers, 9.5-10.5 micrometers and 11.0-12.0 micrometers, and the employment of appropriate preprocessing to minimize atmospheric effects makes it possible to predict general rock-type and temperature for a variety of atmospheric states and temperatures.

Holmes, Q. A.↗

Development of lead salt semiconductor lasers for the 9-17 micron spectral region

Improved diode lasers of Pb sub 1-x Sn sub x Se operating in the 9-17 micrometers spectral region were developed. The performance characteristics of the best lasers exceeded the contract goals of 500 microW/mode at T 30K in the 9-12 micrometers region and 200 microW/mode at T 18K in the 16-17 micrometers region. Increased reliability and device yields resulted from processing improvements which evolved from a series of diagnostic studies. By means of Auger electron spectroscopy, laser shelf storage degradation was shown to be characterized by the presence of In metal on the semiconductor crystal surfaces. Studies of various metal barrier layers between the crystals and the In metal led to the development of an improved metallurgical contacting technology which has resulted in devices with performance stability values exceeding the contract goal of a one year shelf life. Lasers cycled over 500 times between 300K and 77K were also shown to be stable. Studies on improved methods of fabricating striped geometry lasers indicated that good spectral mode characteristics resulted from lasers which stripe widths of 12 and 25 micrometers.

Linden, K. J.↗

The galactic center - 16-30 micron observations and the 18 micron extinction

Within the galactic center, ionized gas, stars, and heated dust are in close proximity to each other. Observations of the galactic center were made during two flight series on NASA aircraft flying at altitudes of more than 12 km. In both series the instrument used was a 10-channel liquid helium cooled grating spectrometer. Three 16-30 micrometers continuum spectra are presented along with two-color scans of the galactic center. No 18.71 micrometers line emission has been detected from Sgr A West. This is consistent with large dust extinction and normal S III/H II abundances. All three 16-30 micrometers continuum spectra show a broad depression centered at about 18 micrometers. This observation is attributed to absorption by cold silicate dust grains. The characteristics of a silicate model are discussed.

Mccarthy, J. F.↗

Fiber optic transmission line stabilization apparatus and method

A reference signal of RF frequency modulates a 0.85 micrometer wavelength optical transmitter. The output of which passes through a first optical filter and a voltage-controller phase shifter. The output of the phase shifter is provided to the fiber optic transmission line. At the receiving end of the transmission line, the signal is demodulated and used to modulate a 1.06 micrometer optical transmitter. The signal from the transmitter is provided to the fiber optic transmission line and passes through the voltage-controlled phase shifter to a phase error detector. The phase of the modulation of the 1.06 micrometer wavelength signal is compared to the phase of the reference signal by the phase error detector. A phase control signal related to the phase difference is provided to the voltage controlled phase shifter which alters the phase of both optical signals until a predetermined phase relationship between modulation on the 1.06 micrometer signal and the reference signal is obtained.

Lutes, G. F., Jr.↗

Studies of single-mode injection lasers and of quaternary materials. Volume 2: Measurement of electro-optic effects in InGaAsP junction waveguides

Both the linear electro-optic (Pockel's) effect and electroabsorption (Franz-Keldysh effect) in waveguiding junctions of InGaAsP were measured. The electro-optic coefficient is found to be 0.1-0.14x10 to the -12 power m/V at lambda = 1.54 - 1.65 micrometers. Possibly this is the first reported measurement of the electro-optic coefficient for InGaAsP. The value found for the electroabsorption is on the order of 7x10 to the -4 power cm to the -1 power/(V/cm) or approximately 100 cm/1 for fields of 200,000 V/cm at lambda 1.3 micrometers. All measurements were made on a quaternary film with a bandgap wavelength of 1.23 micrometers. Because of the rapid commercial introduction of quaternary lasers, LEDs, and detectors to take advantage of large optical fiber bandwidths and low losses in the 1.2- to 1.7- micrometer region, these measurements are significant in providing some of the basic physical constants needed to design modulators and switches capable of operating at microwave frequencies in this wavelength region.

Hammer, J. M.↗

The strength and ductility of polycrystalline NiAl in tension

Experiments at temperatures from 20 C to 400 C at two strain rates (.0001/s and .000005/s) establish that: (1) at room temperatures, binary and microalloyed ( 1000 ppm La, Y, Mo, Ti) NiAl shows negligible ductility, independent of grain size over the range 5 to 140 micrometers; (2) at 295 C the tensile elongation of binary 51 Ni/49 Al increases from 1% to about 5% upon decreasing the grain size to below approximately 10 micrometers; (3) similarly, at 400 C the ductility increases from about 2% to 15% upon decreasing the grain size to below 15 micrometers; (4) the ductility of fine grained (7 micrometer) binary aggregates deformed at 295 C increases from approximately 5% to 12% upon decreasing the strain rate from .0001/s to .000005/s; (5) partial recrystallization (10% to 20%) of warm extruded binary and microalloyed material imparts 1% to 2% ductility at room temperature where fully recrystallized material is brittle; (6) the yield strength obeys a Hall-Petch relationship; and (7) when ductility is not observed, fracture coincides with yielding. The mechanisms underlying the flow and fracture of NiAl are discussed in terms of the nucleation and growth of microcracks. The concept of a critical grain size is considered in the light of the results.

Schulson, E. M.↗

Extension of laboratory-measured soil spectra to field conditions

Spectral responses of two glaciated soils, Chalmers silty clay loam and Fincastle silt loam, formed under prairie grass and forest vegetation, respectively, were measured in the laboratory under controlled moisture equilibria using an Exotech Model 20C spectroradiometer to obtain spectral data in the laboratory under artificial illumination. The same spectroradiometer was used outdoors under solar illumination to obtain spectral response from dry and moistened field plots with and without corn residue cover, representing the two different soils. Results indicate that laboratory-measured spectra of moist soil are directly proportional to the spectral response of that same field-measured moist bare soil over the 0.52 micrometer to 1.75 micrometer wavelength range. The magnitudes of difference in spectral response between identically treated Chalmers and Fincastle soils are greatest in the 0.6 micrometers to 0.8 micrometer transition region between the visible and near infrared, regardless of field condition or laboratory preparation studied.

Stoner, E. R.↗

Middle infrared remote sensing for geology

The middle infrared portion of the spectrum available for geologic remote sensing extends from approximately 3 to 25 micrometers. The source of energy is thermal radiation from surface materials and ambient terrestrial temperatures. The spectral range of usefulness is limited by both the amount of energy available and by transmission of energy through the atmosphere. The best atmospheric window lies between about 8 and 14 micrometers. Remote sensing of the Earth in the infrared is just on the threshold of becoming a valuable geologic tool. Topics which need study include: (1) the used and limitations of the 8 to 14 micrometer region for distinguishing between silicates and nonsilicates; (2) theoretical and experimental understanding of laboratory spectra of rocks and minerals and their relationship to remotely sensed emission spectra; and (3) the possible use of the 3 to 5 and 17 to 25 micrometer portions of the spectrum for remote sensing.

Kahle, A. B.↗

In-flight absolute radiometric calibration of the thematic mapper

In order to determine temporal changes of the absolute radiometric calibration of the entire TM system in flight spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM image collections over the White Sands, New Mexico area. By entering the measured values in an atmospheric radiative transfer program, the radiance levels in four of the spectral bands of the TM were determined, band 1:0.45 to 0.52 micrometers, band 2:0.53 to 0.61 micrometers band 3:0.62 to 0.70 micrometers and 4:0.78 to 0.91 micrometers. These levels were compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors.

Castle, K. R.↗

In-flight absolute radiometric calibration of the Thematic Mapper

In order to determine temporal changes of the absolute radiometric calibration of the entire TM system in flight spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM image collections over the White Sands, NM area. By entering the measured values in an atmospheric radiative transfer program, the radiance levels in four of the spectral bands of the TM were determined, band 1: 0.45 to 0.52 micrometers, band 2: 0.53 to 0.61 micrometers, band 3: 0.62 to 0.70 micrometers, and 4: 0.78 to 0.91 micrometers. These levels were compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors. Previously announced in STAR as N84-15633

Castle, K. R.↗

Measurements of H2O in Jupiter's Atmosphere from 5 Microns Airborne Observations

Measurement of the abundance and vertical distribution of H2O in Jupiter's atmosphere is discussed. Water was first detected using the Kuiper airborne observatory (KAO) and has also been observed at 5 micrometers by the Voyager infrared spectrometer, IRIS. Studies of H2O in the atmospheres of other planets require special high altitude facilities to reduce the interference of telluric H2O. Jovian H2O absorption lines are overwhelmed by terrestrial H2O at ground-based observatories but they are readily apparent in airborne spectra. Typical column abundances of H2O above ground-based telescopes are about 3000 precipitable micrometers versus only 10 pr micrometers above the KAO at the 12.5 km level. For comparison, there is about 150 pr micrometers H2O above the 3 bar level on Jupiter. Airborne observations also take advantage of cryogenic detectors which have not been used thus far on deep space probes.

Bjoraker, G. L.↗

Volcanic eruptions and the increases in the stratospheric aerosol content: Lidar measurements from 1982 to 1986

The results of the observation for stratospheric aerosols which were carried out since the autumn of 1982 by using the NIES large lidar are described. Specifications of the lidar system are shown. The lidar has two wavelenghts of 1.06 and 0.53 micrometers. The 0.53 micrometer is mainly used for the stratospheric aerosols, because the PMT for 0.53 micrometers has higher sensitivity that that for 1.06 micrometers and the total efficiency is higher in the former. A switching circuit is used to control the PMT gain for avoiding signal induced noise in PMT. For the last four years, the stratospheric aerosol layer which was significantly perturbed by the El Chichon volcanic eruption was observed. The scattering ratio profiles observed from 1982 through 1983 are given.

Hayashida, S.↗

Statistical analysis and use of VAS radiance data

Researchers goals are to describe the information content of Vertical Atmospheric Sounder (VAS) radiance data, especially the 6.7 micrometers water vapor channel, to better interpret the atmosphere's water vapor structure from 6.7 micrometers imagery, and to investigate new analysis and forecasting techniques utilizing retrieved VAS soundings. Researchers made major progress toward these goals during FY-85. They are investigating 6.7 micrometer imagery on 6 to 7 March 1982, a day when special mesoscale ground truth data were collected during the 1982 atmospheric variability experiment/vertical amospheric sounder (AVE/VAS) field experiment. A dark (dry) image streak having mesoscale details was located over the special data region, and it provides the major focus of the case study. Mesoscale radiosonde-derived humidity data are found to verify fine scale features of the image that are not evident from the standard National Weather Service network. Thus, VAS imagery is a reliable detector of mesoscale moisture structure during this case. To investigate causes for the image streak, researchers are calculating water vapor budgets. Subsidence is found to be a factor in the current case as well; however, patterns of descent are not related to the jet streak according to traditional conceptual models. Thus, it appears that more research into jet stream dynamics is needed in order to better interpret 6.7 micrometer imagery.

Fuelberg, H. E.↗

Atomic oxygen effects on candidate coatings for long-term spacecraft in low earth orbit

Candidate atomic oxygen protective coatings for long-term low Earth orbit (LEO) spacecraft were evaluated using the Los Alamos National Laboratory O-atom exposure facility. The coatings studied include Teflon, Al2O3, SiO2, and SWS-V-10, a silicon material. Preliminary results indicate that sputtered PTFE Teflon (0.1 micrometers) has a fluence lifetime of 10 to the 19th power O-atoms/cm (2), and sputtered silicon dioxide (0.1 micrometers), aluminum oxide (0.1 micrometers), and SWS-V-10, a silicone, (4 micrometers) have fluence lifetimes of 10 to the 20th power to 10 to the 21st power O-atoms/cm (2). There are large variations in fluence lifetime data for these coatings.

Lan, E. H.↗

IR-dust observations of Comet Tempel 2 with CRAF VIMS

Measurement strategies are now being planned for using the Visual and Infrared Mapping Spectrometer (VIMS) to observe the asteroid Hestia, and the nucleus, and the gas and dust in the coma of comet P/Tempel 2 as part of the Comet Rendezvous Asteroid Flyby (CRAF) mission. The spectral range of VIMS will cover wavelengths from 0.35 to 5.2 micrometers, with a spectral resolution of 11 nm from 0.35 to 2.4 micrometers and of 22 nm from 2.4 to 5.2 micrometers. The instantaneous field of view (IFOV) provided by the foreoptics is 0.5 milliradians, and the current design of the instrument provides for a scanning secondary mirror which will scan a swath of length 72 IFOVs. The CRAF high resolution scan platform motion will permit slewing VIMS in a direction perpendicular to the swath. This enables the building of a two dimensional image in any or all wavelength channels. Important measurements of the dust coma will include the onset of early coma activity, the mapping of gas and dust jets and correlations with active nucleus areas, observations of the dust coma from various scattering phase angles, coverage of the low wavelength portion of the thermal radiation, and the 3.4 micrometer hydrocarbon emission. A description of the VIMS instrument is presented.

Combi, Michael R.↗