Upper wide-angle viewing system for ITER

The Upper Wide Angle Viewing System (UWAVS) will be installed on five upper ports of ITER. Here, this paper shows major requirements, gives an overview of the preliminary design with reasons for some design choices, examines self-emitted IR light from UWAVS optics and its effect on accuracy, and shows calculations of signal-to-noise ratios for the two-color temperature output as a function of integration time and divertor temperature. Accurate temperature output requires correction for vacuum window absorption vs. wavelength and for self-emitted IR, which requires good measurement of the temperature of the optical components. The anticipated signal-to-noise ratio using presently available IR cameras is adequate for the required 500 Hz frame rate.

47 OTHER INSTRUMENTATION↗

The soft x ray telescope for Solar-A

The Solar-A satellite being prepared by the Institute for Sapce and Astronautical Sciences (ISAS) in Japan is dedicated to high energy observations of solar flares. The Soft X Ray Telescope (SXT) is being prepared to provide filtered images in the 2 to 60 A interval. The flight model is now undergoing tests in the 1000 foot tunnel at MSFC. Launch will be in September 1991. Earlier resolution and efficiency tests on the grazing incidence mirror have established its performance in soft x rays. The one-piece, two mirror grazing incidence telescope is supported in a strain free mount separated from the focal plane assembly by a carbon-epoxy metering tube whose windings and filler are chosen to minimize thermal and hygroscopic effects. The CCD detector images both the x ray and the concentric visible light aspect telescope. Optical filters provide images at 4308 and 4700 A. The SXT will be capable of producing over 8000 of the smallest partial frame images per day, or fewer but larger images, up to 1024 x 1024 pixel images. Image sequence with two or more of the five x ray analysis filters, with automatic exposure compensation to optimize the charge collection by the CCD detector, will be used to provide plasma diagnostics. Calculations using a differential emission measure code were used to optimize filter selection over the range of emission measure variations and to avoid redundancy, but the filters were chosen primarily to give ratios that are monotonic in plasma temperature.

Brown, W. A.↗

Raman spectroscopic studies of Nd{sub 0.75}Sm{sub 0.25}GaO{sub 3} single crystals

Single crystals of Nd{sub 1-x}Sm{sub x}GaO{sub 3} (x= 0 and 0.25) were grown by a four mirror IR image furnace using floating zone technique. The crystals are characterized by X-ray diffraction and Raman spectroscopic measurements. NGO adopts orthorhombic structure with Pbnm symmetry and samarium substituted compound also exhibited the same structure as that of the pristine compound without secondary phases. Polarized Raman spectra are measured at ambient temperature in a back scattering geometry. Spectra exhibit low intensity first-order Raman bands. In addition, several high intensity second-order Raman bands have been observed in the frequency range 2000 to 4000 cm{sup −1}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase-Retrieval Uncertainty Estimation and Algorithm Comparison for the JWST-ISIM Test Campaign

Phase retrieval, the process of determining the exitpupil wavefront of an optical instrument from image-plane intensity measurements, is the baseline methodology for characterizing the wavefront for the suite of science instruments (SIs) in the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST). JWST is a large, infrared space telescope with a 6.5-meter diameter primary mirror. JWST is currently NASA's flagship mission and will be the premier space observatory of the next decade. ISIM contains four optical benches with nine unique instruments, including redundancies. ISIM was characterized at the Goddard Space Flight Center (GSFC) in Greenbelt, MD in a series of cryogenic vacuum tests using a telescope simulator. During these tests, phase-retrieval algorithms were used to characterize the instruments. The objective of this paper is to describe the Monte-Carlo simulations that were used to establish uncertainties (i.e., error bars) for the wavefronts of the various instruments in ISIM. Multiple retrieval algorithms were used in the analysis of ISIM phase-retrieval focus-sweep data, including an iterativetransform algorithm and a nonlinear optimization algorithm. These algorithms emphasize the recovery of numerous optical parameters, including low-order wavefront composition described by Zernike polynomial terms and high-order wavefront described by a point-by-point map, location of instrument best focus, focal ratio, exit-pupil amplitude, the morphology of any extended object, and optical jitter. The secondary objective of this paper is to report on the relative accuracies of these algorithms for the ISIM instrument tests, and a comparison of their computational complexity and their performance on central and graphical processing unit clusters. From a phase-retrieval perspective, the ISIM test campaign includes a variety of source illumination bandwidths, various image-plane sampling criteria above and below the Nyquist- Shannon critical sampling value, various extended object sizes, and several other impactful effects.

Design Analysis↗

Characterizing Deformable Mirrors for the MagAO-X Instrument

The MagAO-X instrument is a new extreme adaptive optics system for high-contrast imaging at visibleand near-infrared wavelengths on the Magellan Clay Telescope. A central component of this system is a 2040-actuatormicroelectromechanical deformable mirror (DM) from Boston Micromachines Corp. that operates at 3.63 kHz forhigh-order wavefront control (the tweeter). Two additional DMs from ALPAO perform the low-order (the woofer)and non-common-path science-arm wavefront correction (the NCPC DM). Prior to integration with the instrument, wecharacterized these devices using a Zygo Verifire Interferometer to measure each DM surface. We present the resultsof the characterization effort here, demonstrating the ability to drive tweeter to a flat of 6.9 nm RMS surface (and 0.56nm RMS surface within its control bandwidth), the woofer to 2.2 nm root mean square (RMS) surface, and the NCPCDM to 2.1 nm RMS surface over the MagAO-X beam footprint on each device. Using focus-diversity phase retrievalon the MagAO-X science cameras to estimate the internal instrument wavefront error (WFE), we further show that theintegrated DMs correct the instrument WFE to 18.7 nm RMS, which, combined with a 11.7% pupil amplitude RMS,produces a Strehl ratio of 0.94 at H↵

Kyle Van Gorkom↗

Measurements of Ionizing Radiation Doses Induced by High Irradiance Laser on Targets in LCLS MEC Instrument - Paper 75

High-power laser interaction with targets in vacuum at high laser irradiance levels can generate plasma and, consequently, create ionizing radiation hazards. The theory for ionizing radiation generation from laser-plasma interaction is complicated. The basics of theory and phenomenology are available qualitatively. However, the ionizing radiation yields associated with laser-plasma interaction have not been well quantified. Based on the theoretical analysis and review of the published reports and measurement data, SLAC National Accelerator Laboratory (SLAC) developed an analytic model to estimate conservatively the electron temperature and photon radiation yield (Sv/J) of a laser pulse hitting a solid target at 1 m as a function of laser irradiance between 10{sup 15} and 10{sup 21} W/cm{sup 2}. Ionizing radiation measurements from high-intensity laser-induced plasma interactions on solid targets inside the Al-walled vacuum chamber of the LCLS MEC instrument at SLAC were conducted using passive and active detectors at irradiance between 3x10{sup 16} and 6x10{sup 17} W/cm{sup 2}. Each run of the more than 20 runs had a unique set of laser, optic and target conditions with laser pulses rastering over the target surface mainly perpendicularly at a fixed irradiance. Significant effort was made in characterizing the laser irradiance values for each configuration of laser, focusing mirror, and target; four irradiances with targets of Au foils and copper plate were found to produce good measurement results. Electron doses inside the target chamber were highly anisotropic and peaked at backward direction by several orders of magnitude. Photon doses outside the target chamber were nearly isotropic (a factor of ∼2 higher in backward direction). When considering the large uncertainties of the irradiance (a factor of 2-3) and the potential shielding effects from detectors and target chamber, the measured photon dose rates at 1 m (150 mJ and 10 Hz) outside the target chamber (when averaged over different types of detectors) were in good agreement (a factor of ∼3) with the calculated values of the SLAC model, except at 3.0x10{sup 16} W/cm{sup 2}, which has an electron temperature of only 14 keV. At 6x10{sup 17} W/cm{sup 2}, a low level of ∼0.1 mrem/h from fast neutrons was measured (at 1 m, 150 mJ and 10 Hz) with a neutron-to-photon dose ratio of 0.2%. This is equivalent to a neutron dose yield of 2.8x10{sup -8} mSv/J (to be compared to the LULI measurements of 1x10{sup -4} mSv/J at 3x10{sup 19} W/cm{sup 2}). Both active and passive types of detectors performed well and the dose results were consistent, which is the same as the dose measurements in the Titan laser facility. Active detectors were not affected by the electromagnetic pulses associated with the MEC laser system; this was different from the Titan radiation measurements, in which all active detectors failed to respond, likely due to the high EMP in the Titan's high laser intensity fields. (authors)

43 PARTICLE ACCELERATORS↗

High-resolution broadband spectroscopy using externally dispersed interferometry at the Hale telescope: Part 2, photon noise theory

High-resolution broadband spectroscopy at near-infrared (NIR) wavelengths (950 to 2450 nm) has been performed using externally dispersed interferometry (EDI) at the Hale telescope at Mt. Palomar, with the TEDI interferometer mounted within the central hole of the 200-in. primary mirror in series with the comounted TripleSpec NIR echelle spectrograph. These are the first multidelay EDI demonstrations on starlight. We demonstrated very high (10×) resolution boost and dramatic (20× or more) robustness to point spread function wavelength drifts in the native spectrograph. Data analysis, results, and instrument noise are described in a companion paper (part 1). This part 2 describes theoretical photon limited and readout noise limited behaviors, using simulated spectra and instrument model with noise added at the detector. We show that a single interferometer delay can be used to reduce the high frequency noise at the original resolution (1× boost case), and that except for delays much smaller than the native response peak half width, the fringing and nonfringing noises act uncorrelated and add in quadrature. This is due to the frequency shifting of the noise due to the heterodyning effect. We find a sum rule for the noise variance for multiple delays. The multiple delay EDI using a Gaussian distribution of exposure times has noise-to-signal ratio for photon-limited noise similar to a classical spectrograph with reduced slitwidth and reduced flux, proportional to the square root of resolution boost achieved, but without the focal spot limitation and pixel spacing Nyquist limitations. At low boost (~1×) EDI has ~1.4× smaller noise than conventional, and at >10× boost, EDI has ~1.4× larger noise than conventional. Readout noise is minimized by the use of three or four steps instead of 10 of TEDI. Net noise grows as step phases change from symmetrical arrangement with wavenumber across the band. As a result, for three (or four) steps, we calculate a multiplicative bandwidth of 1.8:1 (2.3:1), sufficient to handle the visible band (400 to 700 nm, 1.8:1) and most of TripleSpec (2.6:1).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Facile synthesis of the nitrogen-doped graphene quantum dots at low temperature for cellular labeling

Highlights: • The N-GQDs are prepared via a facile stirring method on a magnetic stirrer at low temperature. • The N-GQDs exhibit outstanding biocompatibility in the live HeLa cells for biological applications. • The live cells keep a 100% survival rate in the high N-GQDs concentration of 200 μg mL{sup −1} for 48 h. - Abstract: A facile one-step approach is developed for the large-scale synthesis of nitrogen doped graphene quantum dot (N-GQDs) at low temperature by using citric acid (CA) as the precursor. The emission wavelength of the N-GQDs is nearly excitation-dependent, which may mirror the effects from particles of different sizes and distribution of different emissive sites on nanoparticles. Moreover, the products are then tested with live Hela cells for the extraordinary biocompatibility. The cellular viability is remained to be 100% even after a 48 h exposure with the high N-GQDs concentration of 200 μg mL{sup −1} and this survival rate is really much higher than that have been reported previously. The as-prepared N-GQDs with negligible inherent toxicity exhibit excellent biological applications such as bio-imaging and cell tracking.

60 APPLIED LIFE SCIENCES↗

A Distant Mirror: Solar Oscillations Observed on Neptune by the Kepler K2 Mission

Starting in 2014 December, Kepler (K2) observed Neptune continuously for 49 days at a 1-minute cadence. The goals consisted of studying its atmospheric dynamics, detecting its global acoustic oscillations, and those of the Sun, which we report on here. We present the first indirect detection of solar oscillations in intensity measurements. Beyond the remarkable technical performance, it indicates how Kepler would see a star like the Sun. The result from the global asteroseismic approach, which consists of measuring the oscillation frequency at maximum amplitude max velocity and the mean frequency separation between mode overtones delta velocity, is surprising as the max velocity measured from Neptune photometry is larger than the accepted value. Compared to the usual reference max velocity of the sun equal to 3100 microhertz, the asteroseismic scaling relations therefore make the solar mass and radius appear larger by 13.8 plus or minus 5.8 percent and 4.3 plus or minus 1.9 percent, respectively. The higher max velocity is caused by a combination of the value of max velocity of the sun, being larger at the time of observations than the usual reference from SOHO/VIRGO/SPM (Variability of solar IRradiance and Gravity Oscillations / on board SOHO (Solar and Heliospheric Observatory) / Sun PhotoMeters) data (3160 plus or minus 10 microhertz), and the noise level of the K2 time series, being 10 times larger than VIRGO's. The peak-bagging method provides more consistent results: despite a low signal-to-noise ratio (S/N), we model 10 overtones for degrees iota equal 0, 1, 2. We compare the K2 data with simultaneous SOHO/VIRGO/SPM photometry and Bison (Birmingham Solar-Oscillations Network) velocity measurements. The individual frequencies, widths, and amplitudes mostly match those from VIRGO and BiSON within 1 sigma, except for the few peaks with the lowest S/N.

planets and satellites: individual (Neptune) – s↗

Properties of AlN films deposited by reactive ion-plasma sputtering

The properties of SiO{sub 2}, Al{sub 2}O{sub 3}, and AlN dielectric coatings deposited by reactive ion-plasma sputtering are studied. The refractive indices of the dielectric coatings are determined by optical ellipsometry. It is shown that aluminum nitride is the optimal material for achieving maximum illumination of the output mirror of a semiconductor laser. A crystalline phase with a hexagonal atomic lattice and oxygen content of up to 10 at % is found by transmission electron microscopy in the aluminum-nitride films. It is found that a decrease in the concentration of residual oxygen in the chamber of the reactive ion-plasma sputtering installation makes it possible to eliminate the appearance of vertical pores in the bulk of the aluminum-nitride film.

36 MATERIALS SCIENCE↗

Thermal Challenge for Sun-Viewing Instruments on Solar Probe 3 R(sub s) from Sun

The Solar Probe science team at NASA GSFC is considering enhance science observations by adding the nadir viewing Plasma Spectrometer instrument and using heat shields to protect the Plasma Wave antennas to permit full extension at 3 R. The electrostatic mirror of the Plasma Spectrometer is thermally protected from the Sun by a miniature sunshield that consists of two carbon-carbon composite layers, and a much smaller carbon-carbon heat shield. The sun-viewing surface of the miniature sunshield has an Al2O3 thin film coating. The slope of the sunshield is minimized to the smallest possible extent so that it can still accommodate the elliptical electrostatic mirror. Two small MLI flaps minimize the heat radiation from the Plasma Spectrometer to the spacecraft bus. This design meets the thermal requirements. Each of the four Plasma Wave wire antennas is 5 m long, and thermally protected from the Sun by a sunshield. The sunshield consists of two carbon-carbon composite sheets. One sheet views the Sun, and one does not. The slope of most of the sun-viewing sheet is 23deg with the nadir axis. For mechanical reason, it gradually increases to 37.5deg at the tip. The exterior of the sun viewing surfaces has a thin film of Al2O3. The exterior of the shaded sheets has a thin film of vapor deposited rhodium. It minimizes the heat radiation to the spacecraft bus. A high temperature MLI blanket between the carbon-carbon sheets radiatively isolates them. The thermal design meets the temperature requirements, but exceeds the 20 W limit of heat radiation to the spacecraft bus by 20 W. Thermal options to reduce the heat radiation include reducing the alpha to epsilon ratio of the Al2O3 thin film and reducing the number of antennas to three. Testing in 2006 includes thermal model validation and materials testing. High temperature ovens and a high light intensity Vortex Lamp will be used.

Choi, Michael K.↗

Polarized fusion and potential in situ tests of fuel polarization survival in a tokamak plasma

Abstract The use of spin-polarized fusion fuels would provide a significant boost towards the ignition of a burning plasma. The cross section for D + T → α + n, would be increased by 1.5 if the fuels were injected with parallel polarization. Furthermore, our simulations demonstrate additional non-linear power gains in large-scale machines such as ITER, due to increased alpha heating. Such benefits require the survival of spin polarizations for periods comparable to the particle confinement time. During the 1980s, calculations predicted that polarizations could survive a plasma environment, although concerns persisted regarding the cumulative impacts of wall recycling. In that era, technical challenges prevented direct tests and left the large scale fueling of a power reactor beyond reach. Over the last decades, this situation has changed dramatically. Detailed simulations of ITER have predicted negligible wall recycling in a high-power reactor, and recent advances in laser-driven sources project the capability of producing large quantities of ∼100% polarized D and T. The remaining crucial step is an in-situ demonstration of polarization survival in a plasma. For this, we outline a measurement strategy using the isospin-mirror reaction, D + 3 He → α + p. Polarized 3 He avoids the complexities of handling tritium, while encompassing the same spin-physics. We evaluate two methods of delivering deuterium, using dynamically polarized Lithium-Deuteride (with vector polarization P V D of 70%) or frozen-spin Hydrogen-Deuteride (with P V D of 40%), together with a method of injecting optically-pumped 3 He (with 65% polarization). Pellets of these materials all have long polarization decay times (∼6 min for LiD at 2 K, ∼2 months for HD at 2 K, and ∼3 d for 3 He at 77 K), all far greater than a plasma shot in a research tokamak such as DIII-D (∼20 s). Both species can be propelled from a single cryogenic injection gun. We review plasma requirements and strategies for detecting polarization survival. Polarization alters both fusion yields and the angular distribution of fusion products, and each of these provides a potential signal. In this paper we simulate a selection of shots with similar characteristics in a future high-T ion H plasma, and find ratios of yields from shots with fuel spins parallel and antiparallel reaching 1.3 (HD + 3 He) to 1.6 (LiD + 3 He) over a wide range of poloidal angles. (A companion paper finds sensitivity to fusion product angular distributions as reflected in the pitch angles of protons and alphas reaching the plasma facing wall.)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

COSMOLOGICAL EVOLUTION OF SUPERMASSIVE BLACK HOLES. II. EVIDENCE FOR DOWNSIZING OF SPIN EVOLUTION

The spin is an important but poorly constrained parameter for describing supermassive black holes (SMBHs). Using the continuity equation of SMBH number density, we explicitly obtain the mass-dependent cosmological evolution of the radiative efficiency for accretion, which serves as a proxy for SMBH spin. Our calculations make use of the SMBH mass function of active and inactive galaxies (derived in the first paper of this series), the bolometric luminosity function of active galactic nuclei (AGNs), corrected for the contribution from Compton-thick sources, and the observed Eddington ratio distribution. We find that the radiative efficiency generally increases with increasing black hole mass at high redshifts (z {approx}> 1), roughly as {eta}{proportional_to}M{sup 0.5}{sub .}, while the trend reverses at lower redshifts, such that the highest efficiencies are attained by the lowest mass black holes. Black holes with M{sub .} {approx}> 10{sup 8.5} M{sub Sun} maintain radiative efficiencies as high as {eta} Almost-Equal-To 0.3-0.4 at high redshifts, near the maximum for rapidly spinning systems, but their efficiencies drop dramatically (by an order of magnitude) by z Almost-Equal-To 0. The pattern for lower mass holes is somewhat more complicated but qualitatively similar. Assuming that the standard accretion disk model applies, we suggest that the accretion history of SMBHs and their accompanying spins evolves in two distinct regimes: an early phase of prolonged accretion, plausibly driven by major mergers, during which the black hole spins up, then switching to a period of random, episodic accretion, governed by minor mergers and internal secular processes, during which the hole spins down. The transition epoch depends on mass, mirroring other evidence for 'cosmic downsizing' in the AGN population; it occurs at z Almost-Equal-To 2 for high-mass black holes and somewhat later, at z Almost-Equal-To 1, for lower mass systems.

79 ASTRONOMY AND ASTROPHYSICS↗

PHASE QUANTIZATION STUDY OF SPATIAL LIGHT MODULATOR FOR EXTREME HIGH-CONTRAST IMAGING

Direct imaging of exoplanets by reflected starlight is extremely challenging due to the large luminosity ratio to the primary star. Wave-front control is a critical technique to attenuate the speckle noise in order to achieve an extremely high contrast. We present a phase quantization study of a spatial light modulator (SLM) for wave-front control to meet the contrast requirement of detection of a terrestrial planet in the habitable zone of a solar-type star. We perform the numerical simulation by employing the SLM with different phase accuracy and actuator numbers, which are related to the achievable contrast. We use an optimization algorithm to solve the quantization problems that is matched to the controllable phase step of the SLM. Two optical configurations are discussed with the SLM located before and after the coronagraph focal plane mask. The simulation result has constrained the specification for SLM phase accuracy in the above two optical configurations, which gives us a phase accuracy of 0.4/1000 and 1/1000 waves to achieve a contrast of 10{sup -10}. Finally, we have demonstrated that an SLM with more actuators can deliver a competitive contrast performance on the order of 10{sup -10} in comparison to that by using a deformable mirror.

79 ASTRONOMY AND ASTROPHYSICS↗

Mode properties of low-frequency waves: Kinetic theory versus Hall-MHD

In fluid theory, the ordering of low-frequency modes in a homogeneous plasma is based on the phase velocity, since modes do not intersect each other in dispersion diagrams as a function of wavenumber or other parameters. In linear kinetic theory, modes cross each other. Thus a consistent and useful classification should be based on the physical properties of the modes instead. This paper attempts such a classification by documeting the dispersion and general mode properties of the low-frequency waves (omega much less than (OMEGA(sub ci) OMEGA(sub ce) (exp 1/2)), where OMEGA(sub ci), OMEGA(sub ce) are the cyclotron frequencies of the ions and electrons, respectively) in kinetic theory, and by comparing them to the results of two-fluid theory. Kinetic theory gives a seperate Alfven/ion-cyclotron (A/IC) wave with phase speed Omega/k approximately = v(sub A) cos theta for omega much less than OMEGA(sub ci), where v(sub A) is the Alfven velocity and theta the angle of propagation between wave vector k and background magnetic field B(sub o). For a given wavenumber, the magnetosonic mode is a double-valued solution with a singular point in theta, beta parameter space, where beta is the ratio of thermal pressure to magnetic pressure. It is shown that a branch cut starting at the singular point theta approximately 30 deg, beta approximately 3 and leading to larger beta gives a practical and consitent seperation of this double-valued magnetosonic solution. Selection of this branch cut results in a moderately damped fast/magnetos onic and a heavily damped slow/sound wave. A comprehensive review of the polarization, compressibility and other mode properties is given and shown to be consistent with the selected branch cut. At small wavenumbers, the kinetic mode properties typically start to deviate significantly from their fluid counterparts at beta approximately 0.5. At larger beta, there is no longer a consistent correspondence between the fluid and kinetic modes. Kinetic theory also dictates the use of different mode properties to distinguish between them in observational data. For example, the phase between the density and magnetic field perturbation may become useless at high beta, whereas the direction of the magnetic field perturbations with respect to k and B(sub o) remains a useful characteristic. Two quantities based on this characteristic are suggested and are shown to be useful also to distinguish between the mirror mode and A/IC waves in a plasma with temperature anisotropy.

Krauss-Varban, D.↗

Use of internal scintillator radioactivity to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

Purpose: Positron emission tomography (PET) detectors that use a dual-ended-scintillator readout to measure depth-of-interaction (DOI) must have an accurate DOI function to provide the relationship between DOI and signal ratios to be used for detector calibration and recalibration. In a previous study, the authors used a novel and simple method to accurately and quickly measure DOI function by irradiating the detector with an external uniform flood source; however, as a practical concern, implementing external uniform flood sources in an assembled PET system is technically challenging and expensive. In the current study, therefore, the authors investigated whether the same method could be used to acquire DOI function from scintillator-generated (i.e., internal) radiation. The authors also developed a method for calibrating the energy scale necessary to select the events within the desired energy window. Methods: The authors measured the DOI function of a PET detector with lutetium yttrium orthosilicate (LYSO) scintillators. Radiation events originating from the scintillators' internal Lu-176 beta decay were used to measure DOI functions which were then compared with those measured from both an external uniform flood source and an electronically collimated external point source. The authors conducted these studies with several scintillators of differing geometries (1.5 x 1.5 and 2.0 x 2.0 mm{sup 2} cross-section area and 20, 30, and 40 mm length) and various surface finishes (mirror-finishing, saw-cut rough, and other finishes in between), and in a prototype array. Results: All measured results using internal and external radiation sources showed excellent agreement in DOI function measurement. The mean difference among DOI values for all scintillators measured from internal and external radiation sources was less than 1.0 mm for different scintillator geometries and various surface finishes. Conclusions: The internal radioactivity of LYSO scintillators can be used to accurately measure DOI function in PET detectors, regardless of scintillator geometry or surface finish. Because an external radiation source is not needed, this method of DOI function measurement can be practically applied to individual PET detectors as well as assembled systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tailoring Thermal Radiative Properties with Doped-Silicon Nanowires

Aligned doped-silicon nanowire (D-SiNW) arrays form a hyperbolic metamaterial in the mid-infrared and have unique thermal radiative properties, such as broadband omnidirectional absorption, low-loss negative refraction, etc. A combined theoretical and experimental investigation will be performed to characterize D-SiNW arrays and other metamaterials for tailoring thermal radiative properties. Near-field thermal radiation between anisotropic materials with hyperbolic dispersions will also be predicted for potential application in energy harvesting. A new kind of anisotropic metamaterial with a hyperbolic dispersion in a broad infrared region has been proposed and demonstrated based on aligned doped-silicon nanowire (D-SiNW) arrays. D-SiNW-based metamaterials have unique thermal radiative properties, such as broadband omnidirectional absorption whose width and location can be tuned by varying the filling ratio and/or doping level. Furthermore, high figure of merit (FOM) can be achieved in a wide spectral region, suggesting that D-SiNW arrays may be used as a negative refraction material with much less loss than other structured materials, such as layered semiconductor materials. We have also shown that D-SiNWs and other nanostructures can significantly enhance near-field thermal radiation. The study of near-field radiative heat transfer between closely spaced objects and the electromagnetic wave interactions with micro/nanostructured materials has become an emerging multidisciplinary field due to its importance in advanced energy systems, manufacturing, local thermal management, and high spatial resolution thermal sensing and mapping. We have performed extensive study on the energy streamlines involving anisotropic metamaterials and the applicability of the effective medium theory for near-field thermal radiation. Graphene as a 2D material has attracted great attention in nanoelectronics, plasmonics, and energy harvesting. We have shown that graphene can be used to tailor the transmittance, reflectance, and absorptance of nanostructured materials. Furthermore, graphene can be used to enhance near-field coupling to increase the phonon tunneling probability. We have performed analysis of near-field thermophotovoltaic devices with backside reflecting mirror and with tungsten gratings. We have predicted a large enhancement of electroluminescent refrigeration at a separation distance down to 10 nm due to near-field thermal radiation effect. A heat flux measurement system is developed to measure the near-field radiation in vacuum. We have fabricated doped Si plates separated by sparsely distributed posts to create a 200-800 nm vacuum gap. Our measurement results demonstrate that 11 times enhancement of near-field thermal radiation between parallel doped-Si plates with a lateral dimension 1 cm by 1 cm.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗