Search NASA⌕ Search

SEARCH · Search NASA

Results for “Maintainability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Temperature-Control Apparatus For Hydrogen Maser

Thermal-control apparatus maintains hydrogen maser at nearly constant temperature during long-term operational test. Designed to maintain, in small cylindrical vacuum tank containing maser, nearly isothermal condition when test conducted in air. Provides approximation of more nearly isothermal condition expected to be maintained in intended application, in which maser operated in vacuum environment and losses of heat reduced further by multilayer reflective insulation.

Vessot, R. F. C.↗

Exercise countermeasures for bed-rest deconditioning

The purpose for this 30-day bed rest study was to investigate the effects of short-term, high intensity isotonic and isokinetic exercise training on maintenance of working capacity (peak oxygen uptake), muscular strength and endurance, and on orthostatic tolerance, posture and gait. Other data were collected on muscle atrophy, bone mineralization and density, endocrine analyses concerning vasoactivity and fluid-electrolyte balance, muscle intermediary metabolism, and on performance and mood of the subjects. It was concluded that: The subjects maintained a relatively stable mood, high morale, and high esprit de corps throughout the study. Performance improved in nearly all tests in almost all the subjects. Isotonic training, as opposed to isokinetic exercise training, was associated more with decreasing levels of psychological tension, concentration, and motivation; and improvement in the quality of sleep. Working capacity (peak oxygen uptake) was maintained during bed rest with isotonic exercise training; it was not maintained with isokinetic or no exercise training. In general, there was no significant decrease in strength or endurance of arm or leg muscles during bed rest, in spite of some reduction in muscle size (atrophy) of some leg muscles. There was no effect of isotonic exercise training on orthostasis, since tilt-table tolerance was reduced similarly in all three groups following bed rest. Bed rest resulted in significant decreases of postural stability and self-selected step length, stride length, and walking velocity, which were not influenced by either exercise training regimen. Most pre-bed rest responses were restored by the fourth day of recovery.

Greenleaf, John↗

Time maintenance system for the BMDO MSX spacecraft

The Johns Hopkins University Applied Physics Laboratory (APL) is responsible for designing and implementing a clock maintenance system for the Ballistic Missile Defense Organizations (BMDO) Midcourse Space Experiment (MSX) spacecraft. The MSX spacecraft has an on-board clock that will be used to control execution of time-dependent commands and to time tag all science and housekeeping data received from the spacecraft. MSX mission objectives have dictated that this spacecraft time, UTC(MSX), maintain a required accuracy with respect to UTC(USNO) of +/- 10 ms with a +/- 1 ms desired accuracy. APL's atomic time standards and the downlinked spacecraft time were used to develop a time maintenance system that will estimate the current MSX clock time offset during an APL pass and make estimates of the clock's drift and aging using the offset estimates from many passes. Using this information, the clock's accuracy will be maintained by uplinking periodic clock correction commands. The resulting time maintenance system is a combination of offset measurement, command/telemetry, and mission planning hardware and computing assets. All assets provide necessary inputs for deciding when corrections to the MSX spacecraft clock must be made to maintain its required accuracy without inhibiting other mission objectives. The MSX time maintenance system is described as a whole and the clock offset measurement subsystem, a unique combination of precision time maintenance and measurement hardware controlled by a Macintosh computer, is detailed. Simulations show that the system estimates the MSX clock offset to less than+/- 33 microseconds.

Hermes, Martin J.↗

A novel potential/viscous flow coupling technique for computing helicopter flow fields

The primary objective of this work was to demonstrate the feasibility of a new potential/viscous flow coupling procedure for reducing computational effort while maintaining solution accuracy. This closed-loop, overlapped velocity-coupling concept has been developed in a new two-dimensional code, ZAP2D (Zonal Aerodynamics Program - 2D), a three-dimensional code for wing analysis, ZAP3D (Zonal Aerodynamics Program - 3D), and a three-dimensional code for isolated helicopter rotors in hover, ZAPR3D (Zonal Aerodynamics Program for Rotors - 3D). Comparisons with large domain ARC3D solutions and with experimental data for a NACA 0012 airfoil have shown that the required domain size can be reduced to a few tenths of a percent chord for the low Mach and low angle of attack cases and to less than 2-5 chords for the high Mach and high angle of attack cases while maintaining solution accuracies to within a few percent. This represents CPU time reductions by a factor of 2-4 compared with ARC2D. The current ZAP3D calculation for a rectangular plan-form wing of aspect ratio 5 with an outer domain radius of about 1.2 chords represents a speed-up in CPU time over the ARC3D large domain calculation by about a factor of 2.5 while maintaining solution accuracies to within a few percent. A ZAPR3D simulation for a two-bladed rotor in hover with a reduced grid domain of about two chord lengths was able to capture the wake effects and compared accurately with the experimental pressure data. Further development is required in order to substantiate the promise of computational improvements due to the ZAPR3D coupling concept.

Summa, J. Michael↗

Vibration Isolation Technology (VIT) ATD Project

A fundamental advantage for performing material processing and fluid physics experiments in an orbital environment is the reduction in gravity driven phenomena. However, experience with manned spacecraft such as the Space Transportation System (STS) has demonstrated a dynamic acceleration environment far from being characterized as a 'microgravity' platform. Vibrations and transient disturbances from crew motions, thruster firings, rotating machinery etc. can have detrimental effects on many proposed microgravity science experiments. These same disturbances are also to be expected on the future space station. The Microgravity Science and Applications Division (MSAD) of the Office of Life and Microgravity Sciences and Applications (OLMSA), NASA Headquarters recognized the need for addressing this fundamental issue. As a result an Advanced Technology Development (ATD) project was initiated in the area of Vibration Isolation Technology (VIT) to develop methodologies for meeting future microgravity science needs. The objective of the Vibration Isolation Technology ATD project was to provide technology for the isolation of microgravity science experiments by developing methods to maintain a predictable, well defined, well characterized, and reproducible low-gravity environment, consistent with the needs of the microgravity science community. Included implicitly in this objective was the goal of advising the science community and hardware developers of the fundamental need to address the importance of maintaining, and how to maintain, a microgravity environment. This document will summarize the accomplishments of the VIT ATD which is now completed. There were three specific thrusts involved in the ATD effort. An analytical effort was performed at the Marshall Space Flight Center to define the sensitivity of selected experiments to residual and dynamic accelerations. This effort was redirected about half way through the ATD focusing specifically on the sensitivity of protein crystals to a realistic orbital environment. The other two thrusts of the ATD were performed at the Lewis Research Center. The first was to develop technology in the area of reactionless mechanisms and robotics to support the eventual development of robotics for servicing microgravity science experiments. This activity was completed in 1990. The second was to develop vibration isolation and damping technology providing protection for sensitive science experiments. In conjunction with the this activity, two workshops were held. The results of these were summarized and are included in this report.

Lubomski, Joseph F.↗

Electric-optic resonant phase modulator

An electro-optic resonant cavity is used to achieve phase modulation with lower driving voltages. Laser damage thresholds are inherently higher than with previously used integrated optics due to the utilization of bulk optics. Phase modulation is achieved at higher speeds with lower driving voltages than previously obtained with non-resonant electro-optic phase modulators. The instant scheme uses a data locking dither approach as opposed to the conventional sinusoidal locking schemes. In accordance with a disclosed embodiment, a resonant cavity modulator has been designed to operate at a data rate in excess of 100 Mbps. By carefully choosing the cavity finesse and its dimension, it is possible to control the pulse switching time to within 4 ns and to limit the required switching voltage to within 10 V. Experimentally, the resonant cavity can be maintained on resonance with respect to the input laser signal by monitoring the fluctuation of output intensity as the cavity is switched. This cavity locking scheme can be applied by using only the random data sequence, and without the need of additional dithering of the cavity. Compared to waveguide modulators, the resonant cavity has a comparable modulating voltage requirement. Because of its bulk geometry, resonant cavity modulator has the potential of accommodating higher throughput power. Furthermore, mode matching into a bulk device is easier and typically can be achieved with higher efficiency. On the other hand, unlike waveguide modulators which are essentially traveling wave devices, the resonant cavity modulator requires that the cavity be maintained in resonance with respect to the incoming laser signal. An additional control loop is incorporated into the modulator to maintain the cavity on resonance.

Chen, Chien-Chung↗

A survey of program slicing for software engineering

This research concerns program slicing which is used as a tool for program maintainence of software systems. Program slicing decreases the level of effort required to understand and maintain complex software systems. It was first designed as a debugging aid, but it has since been generalized into various tools and extended to include program comprehension, module cohesion estimation, requirements verification, dead code elimination, and maintainence of several software systems, including reverse engineering, parallelization, portability, and reuse component generation. This paper seeks to address and define terminology, theoretical concepts, program representation, different program graphs, developments in static slicing, dynamic slicing, and semantics and mathematical models. Applications for conventional slicing are presented, along with a prognosis of future work in this field.

Beck, Jon↗

Hypervolemia in men from drinking hyperhydration fluids at rest and during exercise

To test the hypothesis that drink composition is more important than drink osmolality (Osm) for maintaining and increasing plasma volume (PV) at rest and during exercise, six men (22-39 yr, 76.84 +/- 16.19 kg, 2.99 +/- 0.45 L/min VO2 peak) each underwent six treatments while sitting for 90 min (VO2 = 0.39 L/min) and then performed upright ergometer exercise for 70 min (VO2 = 2.08 +/- 0.33 1/min, 70% +/- 7% VO2 peak). Drink formulations (10 ml/kg body weight, X = 768 ml) for the sitting period were: P1 (55 mEq Na(+), 365 mOsm/kg H2O), P2 (97.1 mEq Na(+), 791 mOsm/kg), P2G (113 mEqNa(+), 80 ml glycerol, 1,382 mOsm/kg, HyperAde (HA) (164 mEq Na(+), 253 mOsm/kg), and 01 and 02 (no drinking). The exercise drink (10 ml/kg, 768 ml) was P1 for all treatments except 02. Plasma volume at rest increased (p less than 0.05) by 4.7% with P1 and by 7.9% with HA. Percent change in PV during exercise was +1% to +3%0(NS) with HA; -6% to 0% (NS) with P1, P2, P2G, and 01; and -8% to -5% (p less than 0.05) with 02. HyperAde, with the lowest osmolality (253 mOsm/kg), maintained PV at rest and during exercise, whereas the other drinks with lower Na(+) and higher osmolality (365 to 1,382 mOsm/kg) did not. But Performance 1 also increased PV at rest. Thus, drink composition may be more important than drink osmolality for increasing plasma volume at rest and for maintaining it during exercise.

Greenleaf, J. E.↗

Actively controlled shaft seals for aerospace applications

This study experimentally investigates an actively controlled mechanical seal for aerospace applications. The seal of interest is a gas seal, which is considerably more compact than previous actively controlled mechanical seals that were developed for industrial use. In a mechanical seal, the radial convergence of the seal interface has a primary effect on the film thickness. Active control of the film thickness is established by controlling the radial convergence of the seal interface with piezoelectric actuator. An actively controlled mechanical seal was initially designed and evaluated using a mathematical model. Based on these results, a seal was fabricated and tested under laboratory conditions. The seal was tested with both helium and air, at rotational speeds up to 3770 rad/sec, and at sealed pressures as high as 1.48 x 10(exp 6) Pa. The seal was operated with both manual control and with a closed-loop control system that used either the leakage rate or face temperature as the feedback. The output of the controller was the voltage applied to the piezoelectric actuator. The seal operated successfully for both short term tests (less than one hour) and for longer term tests (four hours) with a closed-loop control system. The leakage rates were typically 5-15 slm (standard liters per minute), and the face temperatures were generally maintained below 100 C. When leakage rate was used as the feedback signal, the setpoint leakage rate was typically maintained within 1 slm. However, larger deviations occurred during sudden changes in sealed pressure. When face temperature was used as the feedback signal, the setpoint face temperature was generally maintained within 3 C, with larger deviations occurring when the sealed pressure changed suddenly.

Salant, Richard F.↗

Actively Controlled Shaft Seals for Aerospace Applications

This study experimentally investigates an actively controlled mechanical seal for aerospace applications. The seal of interest is a gas seal, which is considerably more compact than previous actively controlled mechanical seals that were developed for industrial use. In a mechanical seal, the radial convergence of the seal interface has a primary effect on the film thickness. Active control of the film thickness is established by controlling the radial convergence of the seal interface with a piezoelectric actuator. An actively controlled mechanical seal was initially designed and evaluated using a mathematical model. Based on these results, a seal was fabricated and tested under laboratory conditions. The seal was tested with both helium and air, at rotational speeds up to 3770 rad/sec, and at sealed pressures as high as 1.48 x 10(exp 6) Pa. The seal was operated with both manual control and with a closed-loop control system that used either the leakage rate or face temperature as the feedback. The output of the controller was the voltage applied to the piezoelectric actuator. The seal operated successfully for both short term tests (less than one hour) and for longer term tests (four hours) with a closed-loop control system. The leakage rates were typically 5-15 slm (standard liters per minute), and the face temperatures were generally maintained below 100C. When leakage rate was used as the feedback signal, the setpoint leakage rate was typically maintained within 1 slm. However, larger deviations occurred during sudden changes in sealed pressure. When face temperature was used as the feedback signal, the setpoint face temperature was generally maintained within 3 C, with larger deviations occurring when the sealed pressure changes suddenly. the experimental results were compared to the predictions from the mathematical model. The model was successful in predicting the trends in leakage rate that occurred as the balance ratio and sealed pressure changed, although the leakage rates were not quantitatively predicted with a high degree of accuracy. This model could be useful in providing valuable design information for future actively controlled mechanical seals.

Salant, Richard F.↗

UFC advisor: An AI-based system for the automatic test environment

The Air Logistics Command within the Air Force is responsible for maintaining a wide variety of aircraft fleets and weapon systems. To maintain these fleets and systems requires specialized test equipment that provides data concerning the behavior of a particular device. The test equipment is used to 'poke and prod' the device to determine its functionality. The data represent voltages, pressures, torques, temperatures, etc. and are called testpoints. These testpoints can be defined numerically as being in or out of limits/tolerance. Some test equipment is termed 'automatic' because it is computer-controlled. Due to the fact that effective maintenance in the test arena requires a significant amount of expertise, it is an ideal area for the application of knowledge-based system technology. Such a system would take testpoint data, identify values out-of-limits, and determine potential underlying problems based on what is out-of-limits and how far. This paper discusses the application of this technology to a device called the Unified Fuel Control (UFC) which is maintained in this manner.

Lincoln, David T.↗

The use of high fidelity CAD models as the basis for training on complex systems

During the design phases of large and complex systems such as NASA's Space Station Freedom (SSF), there are few, if any physical prototypes built. This is often due to their expense and the realization that the design is likely to change. This poses a problem for training, maintainability, and operations groups who are tasked to lay the foundation of plans for using these systems. The Virtual Reality and Visualization Laboratory at the Boeing Advanced Computing Group's Huntsville facility is supporting the use of high fidelity, detailed design models that are generated during the initial design phases, for use in training, maintainability and operations exercises. This capability was used in its non-immersive form to great effect at the SSF Critical Design Review (CDR) during February, 1993. Allowing the user to move about within a CAD design supports many efforts, including training and scenario study. We will demonstrate via a video of the Maintainability SSF CDR how this type of approach can be used and why it is so effective in conveying large amounts of information quickly and concisely. We will also demonstrate why high fidelity models are so important for this type of training system and how it's immersive aspects may be exploited as well.

Miller, Kellie↗

Effects of Daily Administration of Prostaglandin E2 and Its Withdrawal on the Lumbar Vertebral Bodies in Male Rats

The effects of daily prostaglandin E2 (PGE2) treatment (on) and PGE2 treatment followed by withdrawal (on-off) on cancellous bone in lumbar vertebral bodies were studied in 7 month-old male Sprague-Dawley rats. The first groups of rats were given daily subcutaneous injections of 0, 1, 3, and 6 mg PGE2/kg/d for 60,120, and 180 days, and the second group of rats were given PGE2 for 60 days followed by withdrawal for 60 and 120 days. Histomorphometric analyses were performed on double-fluorescent labeled undecalcified sections of fourth lumbar vertebral bodies. Systemic PGE2 treatment elevated cancerous bone mass of lumbar vertebral bodies 26-60%, above control levels within 60 days and continued treatment maintained it for another 120 days, but the excess bone was lost after the treatment was witndrawn. PGE2 treatment for 60 days increased trabecular bone area, trabecular width, and bone formation parameters, and shortened remodeling periods in a dose-response manner. These changes were sustained at the levels achieved by 60-day treatment in the rats treated for 120 and 180 days. The eroded perimeter increased at day 60 and further at day 120 and then plateaued. In the on-off treated rats, the cancenous bone area, bone formation, and resorption parameters returned to near age-related controls by 60 days after withdrawal and were maintained there after 120 days of withdrawal. Therefore, we conclude that the continuous treatment is needed in order to maintain the PGE2-induced bone gain. When these findings were compared to those previously reported for the proximal tibial metaphyses, we found that the proximal tibial spongiosa was much more responsive to PGE2 treatment than the fourth lumbar vertebral body.

Ke, Hua Zhu↗

Long Life Na/NiCl2 Cells

The premature capacity failure of Na/NiCl2 secondary cells due to agglomeration of nickel particles on the surface of the NiCl2 cathode is prevented by addition of a minor amount such as 10 percent by weight of a transition metal such as Co, Fe or Mn to the cathode. The chlorides of the transition metals have lower potentials than nickel chloride and chlorinate during charge. A uniform dispersion of the transition metals in the cathodes prevents agglomeration of nickel, maintains morphology of the electrode, maintains the electrochemical area of the electrode and thus maintains capacity of the electrode. The additives do not effect sintering. The addition of sulfur to the liquid catholyte is expected to further reduce agglomeration of nickel in the cathode.

Bugga, Ratnakumar V.↗

Vascular Responsiveness in Adrenalectomized Rats with Corticosterone Replacement

To determine under resting, unstressed conditions the circulating glucocorticoid concentrations that best maintain sensitivity of the vascular smooth muscle and baroreceptor responses to vasoactive agents, rats with vascular cannulas were sham-adrenalectomized (sham) or adrenalectomized (ADRX) and provided with four levels of corticosterone replacement (-100 mg fused pellets of corticosterone: cholesterol 0, 20, 40, and 80% implanted subcutaneously at the time of adrenal surgery). Changes in vascular and baroreflex responses were determined after intravenous injection of varying doses of phenylephrine and nitroglycerin with measurement of arterial blood pressure and heart rate in the conscious, chronically cannulated rats. Vascular sensitivity was decreased, and resting arterial blood pressure tended to be decreased in the adrenalectomized rats; both were restored to normal with levels of corticosterone (40%), which also maintained body weight gain, thymus weight, and plasma corticosteroid binding globulin concentrations at normal values. The baroreflex curve generated from the sham group was different from the curves generated from the ADRX+O, 20, and 40% groups, but not different from that of the ADRX+80% group, suggesting that the baroreflex is maintained by higher levels of corticosterone than are necessary for the maintenance of the other variables. These data demonstrate that physiological levels of corticosterone (40% pellet) restore vascular responsiveness, body weight, thymus weight, and transcortin levels to normal in ADRX rats, whereas higher levels (80% pellet) are necessary for restoration of the baroreflex.

Darlington, Daniel N.↗

Contamination control program for the Hubble Space Telescope second servicing mission

The integrity and outgassing certification of reflown hardware, maintained between servicing missions while accommodating configuration changes to the hardware, are discussed. The Hubble Space Telescope requires a periodically servicing mission to maintain its scientific capabilities. Servicing carriers are reflown for each servicing mission. The mission contamination control program is unique as it must maintain the current operational capability of the telescope while allowing manned servicing.

Hansen, Patricia A.↗

Development of a mirror pointing mechanism for an atmospheric gas measurement instrument

Development of the Open Path Tunable Infrared Monitor of the Atmosphere (OPTIMA) instrument involved designing a pair of motion systems that could maintain a precise alignment and spatial distance between two mirrors installed on the NASA DC-8 research laboratory aircraft. This is the first airborne optical instrument that allows direct measurement of the gases in the freestream airflow on the exterior of the aircraft. One mirror is mounted within a specially constructed open port cavity in the cabin of the aircraft and the second is mounted 6 meters away on top of the inboard port side (number 2) engine pylon. Three co-aligned laser beams are reflected between the two mirrors 64 times in a Herriott pattern. The resulting sample path length of 384 meters is used to perform a spectral absorption analysis of the airflow between the mirrors. To compensate for normal wing movement and engine oscillations both mirrors were designed as continuously driven mechanisms to maintain alignment within allowable limits. The motion systems of the two mirror assemblies provide five degrees of freedom and are designed to maintain a pointing accuracy within seven arc-sec with a response frequency in excess of 10 Hz. The pylon motion system incorporates controlled pitch and yaw movement. The fuselage motion system compensates for pitch variation as well as linear translation for focal length and vertical aiming of the laser beam via a controlled beam guidance mechanism.

Graham, Michael↗

Neural Network-Based Sensor Validation for Turboshaft Engines

Sensor failure detection, isolation, and accommodation using a neural network approach is described. An auto-associative neural network is configured to perform dimensionality reduction on the sensor measurement vector and provide estimated sensor values. The sensor validation scheme is applied in a simulation of the T700 turboshaft engine in closed loop operation. Performance is evaluated based on the ability to detect faults correctly and maintain stable and responsive engine operation. The set of sensor outputs used for engine control forms the network input vector. Analytical redundancy is verified by training networks of successively smaller bottleneck layer sizes. Training data generation and strategy are discussed. The engine maintained stable behavior in the presence of sensor hard failures. With proper selection of fault determination thresholds, stability was maintained in the presence of sensor soft failures.

Moller, James C.↗