Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Precision Measurement of the Microwave Dielectric Loss of Sapphire in the Quantum Regime with Parts-per-Billion Sensitivity

Dielectric loss is known to limit state-of-the-art superconducting qubit lifetimes. Recent experiments imply upper bounds on bulk dielectric loss tangents on the order of 100 parts per billion but because these inferences are drawn from fully fabricated devices with many loss channels, these experiments do not definitely implicate or exonerate the dielectric. To resolve this ambiguity, we devise a measurement method capable of separating and resolving bulk dielectric loss with a sensitivity at the level of 5 ×10 –9 . The method, which we call the dielectric dipper, involves the in situ insertion of a dielectric sample into a high-quality microwave cavity mode. Smoothly varying the participation of the sample in the cavity mode enables a differential measurement of the dielectric loss tangent of the sample. The dielectric dipper can probe the low-power behavior of dielectrics at cryogenic temperatures and does so without the need for any lithographic process, enabling controlled comparisons of substrate materials and processing techniques. We demonstrate the method with measurements of sapphire grown by edge-defined film-fed growth (EFG) in comparison to high-grade sapphire grown by the heat-exchanger method (HEMEX). For EFG sapphire, we infer a bulk loss tangent of 63⁢(8) ×10 –9 and a substrate-air interface loss tangent of 15⁢(3) ×10 –4 (assuming a sample surface thickness of 3 nm). For a typical transmon, this bulk loss tangent would limit device quality factors to Q ≲20 ×10 6 , suggesting that bulk loss is likely the dominant loss mechanism in the longest-lived transmons on sapphire. We also demonstrate this method on HEMEX sapphire and bound its bulk loss tangent to be less than 19⁢(6) ×10 –9 . As this bound is about 3 times smaller than the bulk loss tangent of EFG sapphire, the use of HEMEX sapphire as a substrate would lift the bulk dielectric coherence limit of a typical transmon qubit to several milliseconds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Pressure Sensitive Paint Method: An Overview

Pressure sensitive paint (PSP) is a relatively new aerodynamic measurement method with the unique capability of providing a field measurement of pressure over a test surface. This presentation provides an introductory description of this technology based on a review of the open literature. It confines itself to the application of the method to aircraft development wind tunnel testing, at present the primary application area and thus research focus of the method. Described are PSP fundamentals, the various technology elements comprising PSP technology, and current limitations and considerations in applying the technology. Experimental results are presented to illustrate the present capability of the method.

McLachlan, B. G.↗

Three optical methods for remotely measuring aerosol size distributions.

Three optical probing methods for remotely measuring atmospheric aerosol size distributions are discussed and contrasted. The particular detection methods which are considered make use of monostatic lidar (laser radar), bistatic lidar, and solar radiometer sensing techniques. The theory of each of these measurement techniques is discussed briefly, and the necessary constraints which must be applied to obtain aerosol size distribution information from such measurements are pointed out. Theoretical and/or experimental results are also presented which demonstrate the utility of the three proposed probing methods.

Reagan, J. A.↗

Method and Apparatus for Measuring Fluid Flow

Method and apparatus for making measurements on fluids related to their complex permeability are disclosed. A microwave probe is provided for exposure to the fluids. The probe can be non-intrusive or can also be positioned at the location where measurements are to be made. The impedance of the probe is determined. in part. by the complex dielectric constant of the fluids at the probe. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids. Multiple probes may be selectively positioned to monitor the behavior of the fluids including their flow rate. Fluids may be identified as between two or more different fluids as well as multiple phases of the same fluid based on differences between their complex permittivities.

Arndt, G. Dickey↗

Absolute gain measurement by the image method under mismatched condition

Purcell's image method for measuring the absolute gain of an antenna is particularly attractive for small test antennas. The method is simple to use and utilizes only one antenna with a reflecting plane to provide an image for the receiving antenna. However, the method provides accurate results only if the antenna is matched to its waveguide. In this paper, a waveguide junction analysis is developed to determine the gain of an antenna under mismatched condition. Absolute gain measurements for two standard gain horn antennas have been carried out. Experimental results agree closely with published data.

Lee, Richard Q.↗

Open Circuit Potential Method for Thermodynamic Hydricity Measurements of Metal Hydrides

Metal hydrides are prevalent in many catalytic reactions, and thermodynamic hydricity has emerged as a useful parameter for understanding and predicting key hydride transfer steps with these intermediates. An open circuit potentiometry method for determining the hydricity of metal hydrides with a single thermodynamic parameter is reported. The open circuit potential (OCP) of a solution containing a metal hydride and its conjugate hydride acceptor, along with a conjugate acid/base pair, is coupled with known values for the acid pK a and H + /H – reduction potential to determine the hydricity. Here, the reliability of the method was established by using potentiometry to obtain the hydricity of three hydride complexes with varying supporting ligands and transition metal elements in acetonitrile solvent, all within error of previously reported values. Advantages and drawbacks of this method are discussed, and a recommended workflow for practitioners is introduced.

Anions↗

Non-destructive evaluation method employing dielectric electrostatic ultrasonic transducers

An acoustic nonlinearity parameter (.beta.) measurement method and system for Non-Destructive Evaluation (NDE) of materials and structural members novelly employs a loosely mounted dielectric electrostatic ultrasonic transducer (DEUT) to receive and convert ultrasonic energy into an electrical signal which can be analyzed to determine the .beta. of the test material. The dielectric material is ferroelectric with a high dielectric constant .di-elect cons.. A computer-controlled measurement system coupled to the DEUT contains an excitation signal generator section and a measurement and analysis section. As a result, the DEUT measures the absolute particle displacement amplitudes in test material, leading to derivation of the nonlinearity parameter (.beta.) without the costly, low field reliability methods of the prior art.

Yost, William T.↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of cell electrophoresis as a means of purifying growth hormone secreting cells

Growth hormone secreting cells of the rat anterior pituitary are heavily laden with granules of growth hormone and can be partialy purified on the basis of their resulting high density. Two methods of preparative cell electrophoresis were investigated as methods of enhancing the purification of growth hormone producing cells: density gradient electrophoresis and continuous flow electrophoresis. Both methods provided a two- to four-fold enrichment in growth hormone production per cell relative to that achieved by previous methods. Measurements of electrophoretic mobilities by two analytical methods, microscopic electrophoresis and laser-tracking electrophoresis, revealed very little distinction between unpurified anterior pituitary cell suspensions and somatotroph-enriched cell suspensions. Predictions calculated on the basis of analytical electrophoretic data are consistent with the hypothesis that sedimentation plays a significant role in both types of preparative electrophoresis and the electrophoretic mobility of the growth hormone secreting subpopulation of cells remains unknown.

Plank, Lindsay D.↗

High-speed laser anemometry based on spectrally resolved Rayleigh scattering

Laser anemometry in unseeded flows based on the measurement of the spectrum of Rayleigh scattered laser light is reviewed. The use of molecular scattering avoids the well known problems (particle lag, biasing effects, seed generation, seed injection) of seeded flows. The fundamental limits on velocity measurement accuracy are determined using maximum likelihood methods. Measurement of the Rayleigh spectrum with scanning Fabry-Perot interferometers is analyzed and accuracy limits are established for both single pass and multipass configurations. Multipass configurations have much higher selectivity and are needed for measurements where there is a large amount of excess noise caused by stray laser light. It is shown that Rayleigh scattering is particularly useful for supersonic and hypersonic flows. The results of the analysis are compared with measurements obtained with a Rayleigh scattering diagnostic developed for study of the exhaust plume of a small hydrogen-oxygen rocket, where the velocities are in the range of 1000 to 5000 m/sec.

Seasholtz, Richard G.↗

Further wind tunnel investigation of the SM701 airfoil with aileron and turbulators

Wind tunnel tests were performed on a two-dimensional model of the SM701 airfoil designed for use on the World Class gliders. The test covered a range of Reynolds numbers from 500,000 to 1.7 million. Aerodynamic forces and moments were measured with an external balance. Momentum loss method measurements of the section drag coefficient were also made. Flow visualization techniques provided information on transition from laminar to turbulent flow. Lift, drag, and pitching moment were analyzed and comparisons were made with predicted and previously obtained experimental data. The effects of V-tape turbulators for use in turbulent drag reduction were studied. The performance of a 25 percent chord aileron deflected through plus or minus 20 degrees was researched. The model was designed, constructed, and tested by students at Texas A&M University.

Steen, Gregory↗

High-speed laser anemometry based on spectrally resolved Rayleigh scattering

Laser anemometry in unseeded flows based on the measurement of the spectrum of Rayleigh scattered laser light is reviewed. The use of molecular scattering avoids the well-known problems (particle lag, biasing effects, seed generation, seed injection) of seeded flows. The fundamental limits on velocity measurement accuracy are determined using maximum likelihood methods. Measurement of the Rayleigh spectrum with scanning Fabry-Perot interferometers is analyzed and accuracy limits are established for both single pass and multi-pass configurations. Multi-pass configurations have much higher selectivity and are needed for measurements where there is a large amount of excess noise caused by stray laser light. It is shown that Rayleigh scattering is particularly useful for supersonic and hypersonic flows. The results of the analysis are compared with measurements obtained with a Rayleigh scattering diagnostic developed for study of the exhaust plume of a small hydrogen-oxygen rocket, where the velocities are in the range 1000 to 5000 m/sec.

Seasholtz, R. G.↗

NASA's program in lidar remote sensing

Several major NASA research efforts in lidar remote sensing are reviewed, with attention given to hardware and key sensor issues along with results and expectations. The discussion covers temperature and pressure measurements, measurements methods and instrumentation, pressure data, wind field measurements, atmospheric backscatter measurement, aerosol and cloud measurements, and water vapor measurement. Consideration is also given to the applicability of lidar measurements to problems of operational weather analysis and forecasting, climate studies, mesoscale and severe storm analysis and forecastig, and studies of atmosphere/surface interface.

Theon, John S.↗

Precision of FLEET Velocimetry Using High-Speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 microseconds, precisions of 0.5 meters per second in air and 0.2 meters per second in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision HighSpeed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.↗

Precision of FLEET Velocimetry Using High-speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 micro sec, precisions of 0.5 m/s in air and 0.2 m/s in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision High Speed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.↗

Improved sampling of compressed gases for condensable hydrocarbon content

Sampling process was developed which uses commercially available high pressure filters and provides measurements in fraction of time required by older methods. Measurements show no significant difference in results between low pressure and high pressure samples. Filter method is slightly more accurate than scrubber technique.

Peterson, M. H.↗

Quantitative Phenotypic Analysis of Arabidopsis Thaliana Grown in Microgravity Using Soap, an Applied Artificial Intelligence

Phenotypic analysis is an essential step in studying the gravitropic responses and gravitational stress experienced by plants grown in microgravity. Many of the phenotypic traits analyzed in gravitropism studies, such as root length, leaf area, secondary root count, and number of root hairs, currently rely upon manual measurement methods for quantification. However, new advances in data analysis technology using artificial intelligence offer an opportunity for more efficient phenotypic analysis and a reduction of time spent in the data collection phase. In this project, the ability of a new artificially intelligent data collection software, SOAP (Simple Object Access Protocol), to collect and quantify phenotypic traits of Arabidopsis thaliana will be assessed. This project will test the measurements taken by an initial draft of the software. SOAP will take measurements of shoot length, a key phenotype used to assess A. thaliana stress response when grown in microgravity conditions. Shoot length measurements made by SOAP will be compared against a series of manual shoot length measurements. The comparison between the two methods of data measurement will provide valuable insight into the relative accuracy of SOAP and the margin of human error when conducting lab measurements.

Arabidopsis↗

Temperature retrievals from satellite radiance measurements - An empirical method

This paper presents a method for using satellite measurements to interpolate vertical temperature soundings between radiosonde stations. The calculations presented show that especially in the 1000-800 mb layer, where linear methods of temperature retrieval usually contain large errors, the proposed method reduces the errors substantially. The method finds a set of coefficients, which when multiplied by corresponding measured radiance quantities, yield zero temperature error at a radiosonde station. This derived set of coefficients is then applied to satellite radiance measurements at places between the radiosonde stations. The computations show, for example, that the average absolute error in the layer 1000-800 mb is only 0.3 K when the corresponding 'minimum-information' method error was 2.9 K. The method may be most applicable to measurements from geostationary satellites, but should also be applicable to measurements from polar orbiting satellites under certain conditions.

Fritz, S.↗